:Techniques have been developed for reducing motion blurring artifacts by using respiratory gated computed tomography (CT) in sinogram space and quantitatively evaluating the artifact reduction. A synthetic sinogram was built from multiple scans intercepting a respiratory gating window. A gated CT image was then reconstructed using the filtered back-projection algorithm. Wedge phantoms, developed for quantifying the motion artifact reduction, were scanned while being moved using a computer-controlled linear stage. The resulting artifacts appeared between the high and low density regions as an apparent feature with a Hounsfield value that was the average of the two regions. A CT profile through these regions was fit using two error functions, each modeling the partial-volume averaging characteristics for the unmoving phantom. The motion artifact was quantified by determining the apparent distance between the two functions. The blurring artifact had a linear relationship with both the speed and the tangent of the wedge angles. When gating was employed, the blurring artifact was reduced systematically at the air-phantom interface. The gated image of phantoms moving at 20 mm/s showed similar blurring artifacts as the nongated image of phantoms moving at 10 mm/s. Nine patients were also scanned using the synchronized respiratory motion technique. Image artifacts were evaluated in the diaphragm, where high contrast interfaces intercepted the imaging plane. For patients, this respiratory gating technique reduced the blurring artifacts by 9%-41% at the lung-diaphragm interface.
journal_name
Med Physjournal_title
Medical physicsauthors
Lu W,Parikh PJ,Hubenschmidt JP,Politte DG,Whiting BR,Bradley JD,Mutic S,Low DAdoi
10.1118/1.2074187subject
Has Abstractpub_date
2005-11-01 00:00:00pages
3295-304issue
11eissn
0094-2405issn
2473-4209journal_volume
32pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract:PURPOSE:The objectives are: (i) assess the development of the impedance of some arteries during the first decades of life; (ii) determine the influence of pulse rate in arterial impedance; (iii) compare the structure of some arterial segments with optimized structures with respect to blood flow; and (iv) explain the el...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4876379
更新日期:2014-06-01 00:00:00
abstract::A study of the objective imaging characteristics of a new asymmetric screen-film system is presented herein. The system is characterized by high x-ray absorption asymmetric screens, and a low-noise, high-contrast asymmetric film having near-zero crossover. Comparisons are made with the imaging characteristics of two w...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597407
更新日期:1994-09-01 00:00:00
abstract:PURPOSE:To use machine-learning algorithms and blur measure (BM) operators to automatically detect motion blur in mammograms. Motion blur has been reported to reduce lesion detection performance and mask small abnormalities, resulting in failure to detect them until they reach more advanced stages. Automatic detection ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14069
更新日期:2020-04-01 00:00:00
abstract::The photon spectra in vacuum around four types of 192Ir HDR brachytherapy sources are calculated using the Monte Carlo code EGS4 and the most recent spectral information on 192Ir decay. The air-kerma strengths per unit activity are calculated based on the photon fluence around a bare 192Ir source and around each of fo...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598763
更新日期:1999-11-01 00:00:00
abstract:PURPOSE:To investigate the effect of energy (kVp) and filters (no filter, half Bowtie, and full Bowtie) on the dose response curves of the Gafchromic XRQA2 film and nanoDot optical stimulated luminescence dosimeters (OSLDs) in CBCT dose fields. To measure surface and internal doses received during x-ray volume imager (...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4803466
更新日期:2013-06-01 00:00:00
abstract::This article provides a quantitative evaluation of Varian Medical Systems' beam matching procedure. A one-dimensional y analysis is employed to investigate the level of agreement of matched beams. A customized concept of one-dimensional gamma evaluation was designed. Our algorithm first performs a "local" fit of the r...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2745239
更新日期:2007-07-01 00:00:00
abstract::It has recently been shown that longitudinal aliasing can be a significant and detrimental presence in reconstructed single-slice helical computed tomography (CT) volumes. This aliasing arises because the directly measured data in helical CT are generally undersampled by a factor of at least 2 in the longitudinal dire...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1350583
更新日期:2001-03-01 00:00:00
abstract::Scanning film densitometry routinely used for obtaining dosimetric information about therapy treatment beams is subject to several sources of inaccuracies. The most significant of these are described and appropriate methods of testing are presented. This establishes the need for adequate acceptance testing followed by...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595407
更新日期:1983-09-01 00:00:00
abstract:PURPOSE:To investigate how the setting of optimization parameters, fractional dose and tuning structure in tomotherapy treatment planning affects plan dosimetric quality and treatment efficiency. METHODS:A digital phantom to simulate head and neck radiotherapy was constructed for this study. Tumor was 10cm long C-shap...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735724
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:To develop a pencil beam dose calculation algorithm for scanned proton beams that improves modeling of scatter events. METHODS:Our pencil beam algorithm (PBA) was developed for calculating dose from monoenergetic, parallel proton beams in homogeneous media. Fermi-Eyges theory was implemented for pencil beam tr...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735624
更新日期:2012-06-01 00:00:00
abstract::A new radiographic patient positioning technique developed for radiosurgery has been analyzed to show the effect of computed tomography (CT) slice thickness on the precision of target localization during treatment. The positioning technique establishes the pose of the patient's anatomy during treatment by comparing tr...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598500
更新日期:1999-02-01 00:00:00
abstract::Intrafraction organ motion can limit the advantage of highly conformal dose techniques such as intensity modulated radiation therapy (IMRT) due to target position uncertainty. To ensure high accuracy in beam targeting, real-time knowledge of the target location is highly desired throughout the beam delivery process. T...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2905225
更新日期:2008-05-01 00:00:00
abstract:PURPOSE:Monte Carlo (MC) simulation can be used for accurate electron beam treatment planning and modeling. Measurement of large electron fields, with the applicator removed and secondary collimator wide open, has been shown to provide accurate simulation parameters, including asymmetry in the measured dose, for the fu...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3592640
更新日期:2011-06-01 00:00:00
abstract::A new type of radiographic film, EDR (extended dose range) film, has been recently become available for film dosimetry. It is particularly attractive for composite isodose verification of intensity modulated radiation therapy because of its low sensitivity relative to the more common Kodak XV film. For XV film, the re...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1568979
更新日期:2003-05-01 00:00:00
abstract::Electronic portal imaging devices (EPIDs) are mainly used for patient setup verification during treatment but other geometric properties like block shape and leaf positions are also determined. Electronic portal dosimetry allows dosimetric treatment verification. By combining geometric and dosimetric information, the ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1640972
更新日期:2004-02-01 00:00:00
abstract:PURPOSE:To apply the dual ionization chamber method for mixed radiation fields to an accurate comparison of the secondary neutron dose arising from the use of a tungsten alloy multileaf collimator (MLC) as opposed to a brass collimator system for defining the shape of a therapeutic proton field. METHODS:Hydrogenous an...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3656025
更新日期:2011-11-01 00:00:00
abstract:PURPOSE:Automated segmentation could improve the efficiency of modeling-based pelvic organ prolapse (POP) evaluations. However, segmentation performance is limited by the blurry soft tissue boundaries. In this study, we aimed to present a hybrid solution for uterus, rectum, bladder, and levator ani muscle segmentation ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14377
更新日期:2020-09-01 00:00:00
abstract::An optimization analysis of digital fluoroscopy has been carried out using (signal/noise)2/dose as a figure of merit. Three signal detection tasks have been considered: (i) small iodine-containing blood vessels; (ii) regions of fat; and (iii) microcalcifications. The effects of x-ray beam filtration and kilovoltage on...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595130
更新日期:1982-09-01 00:00:00
abstract::We adapted a small sodium iodide scintillation detector for rapid, in vivo localization of a lost brachytherapy seed. Using the detector, we were able to locate and remove an Ir-192 seed that was not visible to the unaided eye. ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595528
更新日期:1984-07-01 00:00:00
abstract::Noise power spectrum (NPS) and detective quantum efficiency (DQE) for metal-plate/film portal detectors are reported for the Co-60 and Linac 10 MV spectra. The detectors consist of a double-emulsion portal film secured between plates of aluminum, copper, brass, or lead. The NPS was found to be independent of the detec...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598437
更新日期:1998-12-01 00:00:00
abstract::Determination of the relaxation times T1 and T2 which are important for tissue characterization generally requires the use of different pulse sequences in magnetic resonance imaging. In this study, a new pulse sequence which facilitates simultaneous determination of the T1 and T2 times is presented. Determination take...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595867
更新日期:1986-09-01 00:00:00
abstract:PURPOSE:This work introduces a rigid registration framework for patient positioning in radiotherapy, based on real-time surface acquisition by a time-of-flight (ToF) camera. Dynamic properties of the system are also investigated for future gating/tracking strategies. METHODS:A novel preregistration algorithm, based on...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3664006
更新日期:2012-01-01 00:00:00
abstract:PURPOSE:In cardiac ablation therapy, accurate anatomic guidance is necessary to create effective tissue lesions for elimination of left atrial fibrillation. While fluoroscopy, ultrasound, and electroanatomic maps are important guidance tools, they lack information regarding detailed patient anatomy which can be obtaine...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4861712
更新日期:2014-02-01 00:00:00
abstract:PURPOSE:Tomosynthesis is a promising modality for breast imaging. The appearance of the tomosynthesis reconstructed image is greatly affected by the choice of acquisition and reconstruction parameters. The purpose of this study was to investigate the limitations of tomosynthesis breast imaging due to scan parameters an...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3357288
更新日期:2010-04-01 00:00:00
abstract:PURPOSE:IAEA TRS-398 notes that cylindrical ionization chambers are preferred for reference proton dosimetry. If a cylindrical ionization chamber is used in a phantom to measure the dose as a function of depth, the effective point of measurement (EPOM) must be taken into account. IAEA TRS-398 recommends a displacement ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4921617
更新日期:2015-07-01 00:00:00
abstract::The purpose of this work is to investigate algorithms for the delivery of intensity-modulated fields using independent collimators (IC). Two heuristic algorithms are proposed to calculate jaw-setting sequences for arbitrary 2D intensity distributions. The first algorithm is based on searching the whole intensity matri...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598794
更新日期:1999-12-01 00:00:00
abstract::Computer-aided diagnosis (CAD) has been a major field of research for the past few decades. CAD uses machine learning methods to analyze imaging and/or nonimaging patient data and makes assessment of the patient's condition, which can then be used to assist clinicians in their decision-making process. The recent succe...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13764
更新日期:2020-06-01 00:00:00
abstract:PURPOSE:We present a simple, practical framework for truly 4D lung IMRT planning based on a weighted individual-phase optimization paradigm. This strategy is specifically developed for use in real-time tumor tracking delivery systems so as to utilize respiratory motion as an additional degree of freedom rather than a c...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735644
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:To generate hybrid VMAT-IMRT treatment plans by utilizing an IMRT beam-angle-optimality (BAO) search under a commercially available TPS without the aid of custom optimization software or high performance computing. METHODS:The high dose modulation provided by IMRT beams can be exploited to improve the quality ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735712
更新日期:2012-06-01 00:00:00
abstract::The measurement of output factors for small fields is challenging and can lead to large dose errors in patient treatments if corrections for detector size and scatter from high-Z material are not applied. Due to its high spatial resolution and near tissue equivalence, GAFCHROMIC® film potentially provides a correction...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4740095
更新日期:2012-07-01 00:00:00