Abstract:
:Modulation of the activity of the subthalamic nucleus (STN) using deep brain stimulation (DBS) in patients with advanced Parkinson's disease is the most common procedure performed today by functional neurosurgeons. The STN contours cannot be entirely identified on common 1.5 T images; in particular, the ventromedial border of the STN often blends with the substantia nigra. 3 T magnetic resonance imaging (MRI) provides better resolution and can improve the identification of the STN borders. In this work, we have directly identified the STN using 3 T MR imaging to validate the accuracy of a computer-aided atlas-based procedure for automatic STN identification. Coordinates of the STN were obtained from the Talairach and Tournoux atlas and transformed into the coordinates of the Montreal Neurological Institute (MNI) standard brain volume, creating a mask representation of the STN. 3 T volumetric T1 and T2 weighted (T1w and T2w, respectively) acquisitions were obtained for ten patients. The MNI standard brain volume was registered onto each patient MRI, using a new approach based on global affine, region-of-interest affine, and local nonrigid registrations. The estimated deformation field was then applied to the STN atlas-based mask, providing its location on the patient MRI. The entire procedure required on average about 20 min. Because STN is easily identifiable on 3 T T2w-MRIs, it was manually delineated; the coordinates of the center of mass of the manually and automatically identified structures were compared. Additionally, volumetric overlapping indices were calculated and the spatial relationship between the midcommissural point and the STN center of mass was investigated. All indices indicated, on average, good agreement between manually and automatically identified structures; displacement of the centers of mass of the manually and automatically identified structures was less than or equal to 2.35 mm, and more than 80% of the manually identified volume was covered by the automatic localization, on average. Bland-Altman analysis indicated that the automatic STN identification was within the limits of agreement with the manual localization on 3 T MRIs. Automatic atlas-based STN localization provides an accurate and user-friendly tool and can enhance target identification when 1.5 T scanners with limited capability to identify the STN boundaries are used.
journal_name
Med Physjournal_title
Medical physicsauthors
Stancanello J,Muacevic A,Sebastiano F,Modugno N,Cerveri P,Ferrigno G,Uggeri F,Romanelli Pdoi
10.1118/1.2936229subject
Has Abstractpub_date
2008-07-01 00:00:00pages
3069-77issue
7eissn
0094-2405issn
2473-4209journal_volume
35pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract:PURPOSE:To establish accurate experimental dosimetry techniques for reference dose measurements in nonstandard composite fields. METHODS:A cylindrical PMMA phantom filled with water was constructed, at the center of which reference absorbed dose to water for a head and neck IMRT delivery was measured. Based on the pro...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3392247
更新日期:2010-06-01 00:00:00
abstract::In prostate seed implants, radioactive seeds are implanted into the prostate through a guiding needle with the help of a template and real-time imaging. The ideal locations of the guiding needles and the relative positions of the seeds in each needle are determined before the implantation under the assumption that the...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598971
更新日期:2000-05-01 00:00:00
abstract::Anatomy-based positron emission tomography (PET) image enhancement techniques have been shown to have the potential for improving PET image quality. However, these techniques assume an accurate alignment between the anatomical and the functional images, which is not always valid when imaging the chest due to respirato...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2804721
更新日期:2007-12-01 00:00:00
abstract:PURPOSE:In cardiac ablation therapy, accurate anatomic guidance is necessary to create effective tissue lesions for elimination of left atrial fibrillation. While fluoroscopy, ultrasound, and electroanatomic maps are important guidance tools, they lack information regarding detailed patient anatomy which can be obtaine...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4861712
更新日期:2014-02-01 00:00:00
abstract:PURPOSE:The spatial and temporal tracking performance of a commercially available 3D optical surface imaging system is evaluated for its potential use in frameless stereotactic radiosurgery head tracking applications. METHODS:Both 3D surface and infrared (IR) marker tracking were performed simultaneously on a head pha...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4823757
更新日期:2013-11-01 00:00:00
abstract::In this paper, two new boundary tracing algorithms for segmentation of breast masses are presented. These new algorithms are based on the dynamic programming-based boundary tracing (DPBT) algorithm proposed in Timp and Karssemeijer, [S. Timp and N. Karssemeijer, Med. Phys. 31, 958-971 (2004)] The DPBT algorithm contai...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2791034
更新日期:2007-11-01 00:00:00
abstract:PURPOSE:Elastography using computer tomography (CT) is a promising methodology that can provide patient-specific regional distributions of lung biomechanical properties. The purpose of this paper is to investigate the feasibility of performing elastography using simulated lower dose CT scans. METHODS:A cohort of eight...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14112
更新日期:2020-08-01 00:00:00
abstract:PURPOSE:Ultrasound-induced mild hyperthermia has advantages for noninvasive, localized and controlled drug delivery. In this study, a tissue-mimicking agarose-based phantom with a thermally sensitive indicator was developed for studying the spatial drug delivery profile using ultrasound-induced mild hyperthermia. METH...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4813299
更新日期:2013-08-01 00:00:00
abstract::(Received 22 October 2001; accepted for publication 26 March 2002; published 22 May 2002) With advanced conformal radiotherapy using intensity modulated beams, it is important to have radiation dose verification measurements prior to treatment. Metal oxide semiconductor field effect transistors (MOSFET) have the advan...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1481520
更新日期:2002-06-01 00:00:00
abstract::Significant advances have been made in recent years to improve photon dose calculation. However, accurate prediction of dose perturbation effects near the interfaces of different media, where charged particle equilibrium is not established, remain unsolved. Furthermore, changes in atomic number, which affect the multi...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597611
更新日期:1995-07-01 00:00:00
abstract::Radiographic magnification is often employed in mammography to improve detection of small anatomical details of clinical interest, such as microcalcifications. The image size depends on the conventional magnification factor, on the focal spot size, and on the x-ray angulation. In this paper magnification effects are i...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597288
更新日期:1994-02-01 00:00:00
abstract:PURPOSE:The feasibility of magnetic resonance image (MRI)-based proton therapy is based, among several other factors, on the implementation of appropriate extensions on current dose calculation methods. This work aims to develop a pencil beam algorithm (PBA) for dose calculation of proton beams within magnetic field re...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12854
更新日期:2018-05-01 00:00:00
abstract:PURPOSE:To provide a cascaded-systems framework based on the noise-power spectrum (NPS), modulation transfer function (MTF), and noise-equivalent number of quanta (NEQ) for quantitative evaluation of differential phase-contrast imaging (Talbot interferometry) in relation to conventional absorption contrast under equal-...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4739195
更新日期:2012-09-01 00:00:00
abstract:PURPOSE:This paper presents the design of a micro-CT guided small animal robotic needle positioning system. In order to simplify the robotic design and maintain a small targeting error, a novel implementation of the remote center of motion is used in the system. The system has been developed with the objective of achie...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4771958
更新日期:2013-01-01 00:00:00
abstract:PURPOSE:Melanoma is the most lethal of the three primary skin cancers, including also basal cell carcinoma (BCC) and squamous cell carcinoma (SCC), which are less lethal. The accepted diagnosis process involves manually observing a suspicious lesion through a Dermascope (i.e., a magnifying glass), followed by a biopsy....
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14471
更新日期:2020-11-01 00:00:00
abstract::The aim of the work was to investigate in advance the dosimetric properties of a new multileaf collimator (MLC) concept with the help of Monte Carlo (MC) simulations prior to the production of a prototype. The geometrical design of the MLC was implemented in the MC code GEANT4. For the simulation of a 6 MV treatment b...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2181298
更新日期:2006-04-01 00:00:00
abstract::This article is the first in a series on the calculation of electron dose using multiple-scattering theory. In it we develop a unified theory, which we term Gaussian multiple-scattering theory, starting from a number of contributions already in the literature: the Fermi-Eyges multiple-scattering theory, the Yang path ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596166
更新日期:1988-03-01 00:00:00
abstract::The data from Meisberger et al. [Radiology 90, 953-957 (1968)] are often used as a basis for dose calculations in brachytherapy. In order to describe the absorbed dose in water around a brachytherapy point source, Meisberger provided a polynomial fit for different isotopes taking into account the effect of attenuation...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597583
更新日期:1995-05-01 00:00:00
abstract::During the past decade the use of undersampled acquisition and constrained reconstruction have led to significant increases in data acquisition speed, SNR, spatial resolution and temporal resolution in MR imaging. When a separately acquired constraining image is combined with an angiographic time series the traditiona...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735797
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:The authors previously introduced a methodology to generate a realistic three-dimensional (3D), high-resolution, computer-simulated breast phantom based on empirical data. One of the key components of such a phantom is that it provides a means to produce a realistic simulation of clinical breast compression. In...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3637500
更新日期:2011-10-01 00:00:00
abstract:PURPOSE:Texture analysis (TA) has proved to be useful to distinguish different tissues and disease states using magnetic resonance imaging (MRI). TA has been successfully applied clinically to improve identification of abnormalities in the brain, liver, and bone and, more recently, has been used to enhance the specific...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3622605
更新日期:2011-09-01 00:00:00
abstract::Proton NMR spectroscopy was applied to quantitate the measurement of total body water/fat distributions in vivo. A special MR protocol was developed to excite a thick slab of tissue and display the magnitude NMR spectrum of the collected response signal. Very short echo time TE (8 ms) and long repetition time TR (4000...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596935
更新日期:1992-01-01 00:00:00
abstract:PURPOSE:Two-dimensional antiscatter grids (2DASG) for cone beam computed tomography (CBCT) is a new area of research to reduce scatter intensity, and consequently improve CBCT image quality. One of the challenges in implementation of 2DASGs is their septa shadows that are impinged on the projections. If these artifacts...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13456
更新日期:2019-05-01 00:00:00
abstract::The attenuating properties of several types of lead (Pb)-based and non-Pb radiation shielding materials were studied and a correlation was made of radiation attenuation, materials properties, calculated spectra and ambient dose equivalent. Utilizing the well-characterized x-ray and gamma ray beams at the National Rese...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2426404
更新日期:2007-02-01 00:00:00
abstract:PURPOSE:Radiochromic film provides dose measurement at high spatial resolution, but often is not preferred for routine evaluation of patient-specific intensity modulated radiation therapy (IMRT) plans owing to ease-of-use factors. The authors have established an efficient protocol that combines calibration and measurem...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4754797
更新日期:2012-10-01 00:00:00
abstract:PURPOSE:Water equivalent diameter (WED) is the preferred surrogate for patient size in CT. It is better than geometric size surrogates and patient weight/height/BMI/age because it correlates the best with x-ray attenuation. The administration of oral/IV contrast agents increases a patient's attenuation and should there...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14721
更新日期:2021-01-13 00:00:00
abstract::Calibration of an imported strontium-90 ophthalmic applicator at the U.S. National Bureau of Standards (now the National Institute of Standards and Technology) has disclose a significant discrepancy in dose rate calibration (32%-35%) with that quoted by the manufacturer. The University of Wisconsin has investigated th...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596702
更新日期:1991-03-01 00:00:00
abstract:PURPOSE:Accurate deformable image registration is necessary for longitudinal studies. The error associated with commercial systems has been evaluated using computed tomography (CT). Several in-house algorithms have been evaluated for use with magnetic resonance imaging (MRI), but there is still relatively little inform...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12406
更新日期:2017-10-01 00:00:00
abstract:PURPOSE:To investigate the feasibility of implementing a novel approach for patient-specific QA of TomoDirect(TM) whole breast treatment. METHODS:The most currently used TomoTherapy DQA method, consisting in the verification of the 2D dose distribution in a coronal or sagittal plane of the Cheese Phantom by means of g...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4722967
更新日期:2012-07-01 00:00:00
abstract:PURPOSE:Positron emission tomography (PET) is an important tool for nuclear medical imaging. It has been widely used in clinical diagnosis, scientific research, and drug testing. PET is a kind of emission computed tomography. Its basic imaging principle is to use the positron annihilation radiation generated by radionu...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13804
更新日期:2019-11-01 00:00:00