Abstract:
:Three Monte Carlo photon/electron transport codes (GEPTS, EGSnrc, and MCNP) are bench-marked against dose measurements in homogeneous (both low- and high-Z) media as well as at interfaces. A brief overview on physical models used by each code for photon and electron (positron) transport is given. Absolute calorimetric dose measurements for 0.5 and 1 MeV electron beams incident on homogeneous and multilayer media are compared with the predictions of the three codes. Comparison with dose measurements in two-layer media exposed to a 60Co gamma source is also performed. In addition, comparisons between the codes (including the EGS4 code) are done for (a) 0.05 to 10 MeV electron beams and positron point sources in lead, (b) high-energy photons (10 and 20 MeV) irradiating a multilayer phantom (water/steel/air), and (c) simulation of a 90Sr/90Y brachytherapy source. A good agreement is observed between the calorimetric electron dose measurements and predictions of GEPTS and EGSnrc in both homogeneous and multilayer media. MCNP outputs are found to be dependent on the energy-indexing method (Default/ITS style). This dependence is significant in homogeneous media as well as at interfaces. MCNP(ITS) fits more closely the experimental data than MCNP(DEF), except for the case of Be. At low energy (0.05 and 0.1 MeV), MCNP(ITS) dose distributions in lead show higher maximums in comparison with GEPTS and EGSnrc. EGS4 produces too penetrating electron-dose distributions in high-Z media, especially at low energy (<0.1 MeV). For positrons, differences between GEPTS and EGSnrc are observed in lead because GEPTS distinguishes positrons from electrons for both elastic multiple scattering and bremsstrahlung emission models. For the 60Co source, a quite good agreement between calculations and measurements is observed with regards to the experimental uncertainty. For the other cases (10 and 20 MeV photon sources and the 90Sr/90Y beta source), a good agreement is found between the three codes. In conclusion, differences between GEPTS and EGSnrc results are found to be very small for almost all media and energies studied. MCNP results depend significantly on the electron energy-indexing method.
journal_name
Med Physjournal_title
Medical physicsauthors
Chibani O,Li XAdoi
10.1118/1.1473134subject
Has Abstractpub_date
2002-05-01 00:00:00pages
835-47issue
5eissn
0094-2405issn
2473-4209journal_volume
29pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract:PURPOSE:To characterize a new air vented ionization chamber technology, suitable to build detector arrays with small pixel pitch and independence of sensitivity on dose per pulse. METHODS:The prototype under test is a linear array of air vented ionization chambers, consisting of 80 pixels with 3.5 mm pixel pitch dista...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4945414
更新日期:2016-05-01 00:00:00
abstract:PURPOSE:This work concerns computed tomography (CT)-based cardiac functional analysis (CFA) with a reduced radiation dose. As CT-CFA requires images over the entire heartbeat, the scans are often performed at 10-20% of the tube current settings that are typically used for coronary CT angiography. A large image noise th...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12425
更新日期:2017-09-01 00:00:00
abstract::A fully automatic radiophotoluminescent glass rod dosimeter (GRD) system has recently become commercially available. This article discusses the dosimetric properties of the GRD including uniformity and reproducibility of signal, dose linearity, and energy and directional dependence in high-energy photon beams. In addi...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1758351
更新日期:2004-07-01 00:00:00
abstract:PURPOSE:An improved method of image guidance for lung tumor biopsies could help reduce the high rate of false negatives. The aim of this work is to optimize the geometry of the scanning-beam digital tomography system (SBDX) for providing real-time 3D tomographic reconstructions for target verification. The unique geome...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4826159
更新日期:2013-11-01 00:00:00
abstract:PURPOSE:This article presents a computer-aided diagnosis technique for improving the accuracy of the early diagnosis of Alzheimer's disease (AD). Two hundred and ten 18F-FDG PET images from the ADNI initiative [52 normal controls (NC), 114 mild cognitive impairment (MCI), and 53 AD subjects] are studied. METHODS:The p...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3488894
更新日期:2010-11-01 00:00:00
abstract:PURPOSE:Calculations of deoxyribonucleic acid (DNA) damages involve many parameters in the computation process. As these parameters are often subject to uncertainties, it is of central importance to comprehensively quantify their impacts on DNA single-strand break (SSB) and double-strand break (DSB) yields. This has be...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14036
更新日期:2020-04-01 00:00:00
abstract:PURPOSE:Upgrade and benchmarking of a research 4D treatment planning system (4DTPS) suitable for realistic patient treatment planning and treatment simulations taking into account specific requirements for scanned ion beam therapy, i.e., modeling of dose heterogeneities due to interplay effects and range changes caused...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4800802
更新日期:2013-05-01 00:00:00
abstract:PURPOSE:The purpose of this study was to provide updated radiation dose from diagnostic exams performed for pregnant patients suspected of pulmonary embolism (PE) using the recently developed BREP phantoms of pregnant woman and the fetus. Also to challenge the validity of current recommendations suggest that ventilatio...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12558
更新日期:2017-11-01 00:00:00
abstract:PURPOSE:To develop a new biological equivalent dose (BED) formulism that includes repair, repopulation and resensitization (redistribution and reoxygenation), and can be used to calculate prescribed dose for permanent implant with Cs-131. METHODS:Because of lack of sufficient clinical data, the prescribed dose with ne...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735551
更新日期:2012-06-01 00:00:00
abstract::Consensus has been developing over the past few decades on a number of measurements required for the laboratory assessment of medical imaging modalities. Nevertheless, understanding of the connection between these measurements and human observer performance in a broad range of tasks remains far from complete. Focusing...
journal_title:Medical physics
pub_type: 杂志文章,评审
doi:10.1118/1.597511
更新日期:1995-07-01 00:00:00
abstract:PURPOSE:There is evidence that computed tomography (CT) and positron emission tomography (PET) imaging metrics are prognostic and predictive in nonsmall cell lung cancer (NSCLC) treatment outcomes. However, few studies have explored the use of standardized uptake value (SUV)-based image features of nodal regions as pre...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4926755
更新日期:2015-08-01 00:00:00
abstract::The paper presents a theoretical derivation of the photon fluence simulation efficiency in photon beam treatment head simulations without and with bremsstrahlung splitting. The expressions obtained provide a rigorous explanation of the efficiency dependence on scoring zone size and splitting number and explain the lar...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1943808
更新日期:2005-07-01 00:00:00
abstract::Empirical functions that describe primary beam profiles for radiotherapy treatment planning systems generally account for finite source size only on beams unmodified by blocks, wedges, or compensating filters. To incorporate the effects of extended sources on such modified beams and to treat the effect of an extended ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596222
更新日期:1988-09-01 00:00:00
abstract::A new beam line for radiotherapy and radiosurgery with accelerated helium-ion beams has been set up at the Bevalac. The new treatment room has been equipped with a very precise patient positioner in order to utilize the superior dose localization properties of light-ion beams. The beam spreading and shaping system is ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596696
更新日期:1991-01-01 00:00:00
abstract::A small, lightweight, single-focusing magnetic spectrometer was designed, assembled, and tested for analysis of electron beams from radiotherapy electron linacs. The objective was to develop a low cost, simple device that could be easily replicated in other medical centers, and to demonstrate the practicality of indiv...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597271
更新日期:1994-11-01 00:00:00
abstract:PURPOSE:Four-dimensional volumetric modulated arc therapy (4D VMAT) and four-dimensional intensity-modulated radiotherapy (4D IMRT) are developing radiation therapy treatment strategies designed to maximize dose conformality, minimize normal tissue dose, and deliver the treatment as efficiently as possible. The patient...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12778
更新日期:2018-04-01 00:00:00
abstract:PURPOSE:To investigate the sensitivity of the plan-class specific correction factor to dose distributions in composite nonstandard field dosimetry. METHODS:A cylindrical water-filled PMMA phantom was constructed at the center of which reference absorbed dose could be measured. Ten different TomoTherapy(®)-based IMRT f...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3669487
更新日期:2012-01-01 00:00:00
abstract:PURPOSE:Couch and MLC tracking are two promising methods for real-time motion compensation during radiation therapy. So far, couch and MLC tracking experiments have mainly been performed by different research groups, and no direct comparison of couch and MLC tracking of volumetric modulated arc therapy (VMAT) plans has...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4946815
更新日期:2016-05-01 00:00:00
abstract:PURPOSE:IAEA TRS-398 notes that cylindrical ionization chambers are preferred for reference proton dosimetry. If a cylindrical ionization chamber is used in a phantom to measure the dose as a function of depth, the effective point of measurement (EPOM) must be taken into account. IAEA TRS-398 recommends a displacement ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4921617
更新日期:2015-07-01 00:00:00
abstract:PURPOSE:With the increased commercial availability of intensity modulated arc therapy (IMAT) comes the need for comprehensive QA programs, covering the different aspects of this newly available technology. This manuscript proposes such a program for the RapidArc (RA) (Varian Medical Systems, Palo Alto) IMAT solution. ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3622672
更新日期:2011-09-01 00:00:00
abstract:PURPOSE:The quality of a treatment plan for stereotactic body radiotherapy (SBRT) depends on an experience of each treatment planner. Therefore, the treatment plans are subjectively determined by comparison of several treatment plans developed by time consuming iterative manners, while considering the benefit to a tumo...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735950
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:State of the art to access radiofrequency (RF) heating near implants is computer modeling of the devices and solving Maxwell's equations for the specific setup. For a set of input parameters, a fixed result is obtained. This work presents a theoretical approach in the alternating current (ac) limit, which can p...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3637495
更新日期:2011-10-01 00:00:00
abstract:PURPOSE:For almost four decades bead and wire ramps have been used in the evaluation of slice width as part of QA testing for CT scanners. While each of these approaches have been recognized and accepted as reliable, in this paper we investigate the differences, advantages and limitations of these tools. Moreover, we s...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4734753
更新日期:2012-06-01 00:00:00
abstract::Model-based deformable organ registration techniques using the finite element method (FEM) have recently been investigated intensively and applied to image-guided adaptive radiotherapy (IGART). These techniques assume that human organs are linearly elastic material, and their mechanical properties are predetermined. U...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2163838
更新日期:2006-02-01 00:00:00
abstract::A very important issue in contemporary inverse treatment radiotherapy planning is the specification of proper dose-volume constraints limiting the treatment planning algorithm from delivering high doses to the normal tissue surrounding the tumor. Recently we have proposed a method called reverse mapping of normal tiss...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2198307
更新日期:2006-09-01 00:00:00
abstract:PURPOSE:Variations during breast tissue development can influence later breast cancer risk. In particular, prolonged nulliparity increases risk. The authors used optical spectroscopy to compare breast tissue in 115 nulliparous women aged 31-40 (group 2) to 140 nulliparous women aged 18-21 (group 1), and also to 36 paro...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3276737
更新日期:2010-02-01 00:00:00
abstract:PURPOSE:RapidArc is routinely used for stereotactic radiotherapy for lung cancer. While treatment dose is optimized and calculated on a static CT image, the motion of the target in conjunction with the motion of the MLC may Result in a delivered dose deviating from the planed dose. In this study, we investigate the dos...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4734660
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:To determine the diagnostic efficacy of optical coherence tomography (OCT) to identify cervical intraepithelial neoplasia (CIN) grade 2 or higher by computer-aided diagnosis (CADx). METHODS:OCT has been investigated as a screening/diagnostic tool in the management of preinvasive and early invasive cancers of t...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3523098
更新日期:2011-01-01 00:00:00
abstract::This paper outlines a method for determining proper removal-diffusion parameters to be used in removal-diffusion theory calculations for the purpose of BNCT treatment planning. Additionally, this paper demonstrates that, given the proper choice of removal-diffusion parameters, removal-diffusion theory may provide an a...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1386424
更新日期:2001-09-01 00:00:00
abstract::We discuss a formalism for clinical proton beam dosimetry based on the use of ionization chamber absorbed dose-to-water calibration and beam quality correction factors. A quantity kQ, the beam quality correction factor, is defined which corrects the absorbed dose-to-water calibration factor ND,w in a reference beam of...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597768
更新日期:1996-01-01 00:00:00