Optical spectroscopy of the breast in premenopausal women reveals tissue variation with changes in age and parity.

Abstract:

PURPOSE:Variations during breast tissue development can influence later breast cancer risk. In particular, prolonged nulliparity increases risk. The authors used optical spectroscopy to compare breast tissue in 115 nulliparous women aged 31-40 (group 2) to 140 nulliparous women aged 18-21 (group 1), and also to 36 parous women aged 31-40 (group 3), and to evaluate the relationship between IGF-1 and optical breast tissue properties. IGF-1 has been linked in particular to premenopausal breast cancer. METHODS:The authors measured the transmission spectra from 625 to 1050 nm wavelengths in each breast and determined regions of interindividual variation using principal components analysis. Spectral differences represent variation in lipid, water, oxyhemoglobin, deoxyhemoglobin, and collagen content. Group differences and the relationship with IGF-1 were estimated by linear regression after adjustment for multiple factors including height, weight, ethnicity, hormonal contraceptive use, and days since last menstrual period. RESULTS:Principal component 3 scores were more negative in the older nulliparous women compared to either younger nulliparous women or to parous women of the same age (beta = -0.16, p = 0.008 for group 2 vs group 1 and beta = 0.51, p = 0.03 for group 3 vs group 2). These differences appear to indicate increased deoxyhemoglobin relative to oxyhemoglobin content in the tissue of the older, nulliparous premenopausal women compared to the other groups, which may be an indicator of proportionally increased proliferative tissue. Principal component 4 also differed between older and younger nulliparous women (beta = 0.08, p = 0.02 for group 2 vs. group 1) and was negatively associated with IGF-1 in younger women (beta = -0.0004, p = 0.03) and positively associated with IGF-1 in older women (beta = 0.001, p = 0.004). CONCLUSIONS:Optical spectroscopy may be useful to identify breast tissue at increased risk of cancer development and track changes over time, particularly in young women where exposure to radiation is of particular concern. Additional work is needed to confirm the observed breast tissue differences and to determine the specific tissue chromophore changes with age and parity.

journal_name

Med Phys

journal_title

Medical physics

authors

Knight JA,Blackmore KM,Wong J,Tharmalingam S,Lilge L

doi

10.1118/1.3276737

subject

Has Abstract

pub_date

2010-02-01 00:00:00

pages

419-26

issue

2

eissn

0094-2405

issn

2473-4209

journal_volume

37

pub_type

杂志文章
  • Characterization of electron contamination in megavoltage photon beams.

    abstract::The purpose of the present study is to characterize electron contamination in photon beams in different clinical situations. Variations with field size, beam modifier (tray, shaping block) and source-surface distance (SSD) were studied. Percentage depth dose measurements with and without a purging magnet and replacing...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1895793

    authors: Lopez Medina A,Teijeiro A,Garcia J,Esperon J,Terron JA,Ruiz DP,Carrion MC

    更新日期:2005-05-01 00:00:00

  • Cascaded systems analysis of shift-variant image quality in slit-scanning breast tomosynthesis.

    abstract:PURPOSE:Digital breast tomosynthesis (DBT) is becoming an important part of breast cancer screening and diagnosis. Compared to two-dimensional mammography, tomosynthesis introduces limited three-dimensional (3D) resolution, but maintains high in-plane resolution, low dose, and allows for similar clinical protocols. The...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13116

    authors: Berggren K,Cederström B,Lundqvist M,Fredenberg E

    更新日期:2018-10-01 00:00:00

  • Hybrid computational phantoms of the 15-year male and female adolescent: applications to CT organ dosimetry for patients of variable morphometry.

    abstract::Currently, two classes of the computational phantoms have been developed for dosimetry calculation: (1) stylized (or mathematical) and (2) voxel (or tomographic) phantoms describing human anatomy through mathematical surface equations and three-dimensional labeled voxel matrices, respectively. Mathematical surface equ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2912178

    authors: Lee C,Lodwick D,Williams JL,Bolch WE

    更新日期:2008-06-01 00:00:00

  • Application- and patient size-dependent optimization of x-ray spectra for CT.

    abstract::Although x-ray computed tomography (CT) has been in clinical use for over 3 decades, spectral optimization has not been a topic of great concern; high voltages around 120 kV have been in use since the beginning of CT. It is the purpose of this study to analyze, in a rigorous manner, the energies at which the patient d...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3075901

    authors: Kalender WA,Deak P,Kellermeier M,van Straten M,Vollmar SV

    更新日期:2009-03-01 00:00:00

  • Automated matching and segmentation of lymphoma on serial CT examinations.

    abstract::In patients with lymphoma, identification and quantification of the tumor extent on serial CT examinations is critical for assessing tumor response to therapy. In this paper, we present a computer method to automatically match and segment lymphomas in follow-up CT images. The method requires that target lymph nodes in...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2404617

    authors: Yan J,Zhao B,Curran S,Zelenetz A,Schwartz LH

    更新日期:2007-01-01 00:00:00

  • Noninvasive cardiac arrhythmia ablation with particle beams.

    abstract::Cardiac arrhythmias are a major health burden, associated with reduced quality of life and substantial morbidity and mortality. Current therapy includes moderately effective medication and catheter-based ablation of arrhythmogenic substrates in the heart. Catheter interventions frequently have to be repeated due to re...

    journal_title:Medical physics

    pub_type: 杂志文章,评审

    doi:10.1002/mp.12595

    authors: Graeff C,Bert C

    更新日期:2018-11-01 00:00:00

  • Effective point of measurement of thimble ion chambers in megavoltage photon beams.

    abstract:PURPOSE:Determine the effective point of measurement (EPOM) of 12 thimble ion chambers, including miniature chambers and three models widely used for clinical reference dosimetry. The EPOM is the point at which the measured dose would arise in the measurement medium in the absence of the probe: For cylindrical chambers...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3266750

    authors: Tessier F,Kawrakow I

    更新日期:2010-01-01 00:00:00

  • Determining Pion, the correction factor for recombination losses in an ionization chamber.

    abstract::The 1983 AAPM protocol for the determination of absorbed dose from high-energy photon and electron beams recommends using Pion (the reciprocal of collection efficiency), as determined by the two-voltage technique, to correct for recombination losses in ionization chambers. Methods and data for the determination of ion...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595574

    authors: Weinhous MS,Meli JA

    更新日期:1984-11-01 00:00:00

  • SU-E-T-476: GPU-Based Monte Carlo Radiotherapy Dose Calculation Using Phase- Space Sources.

    abstract:PURPOSE:To design an efficient method for utilizing phase-space source models in the GPU-based Monte Carlo (MC) dose calculation engine gDPM. METHODS:In GPU-based MC algorithms, particles are transported in parallel on different threads. Particles of different types and energies can require significantly different exe...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735565

    authors: Townson R,Jia X,Zavgorodni S,Jiang S

    更新日期:2012-06-01 00:00:00

  • Monte Carlo assessment of computed tomography dose to tissue adjacent to the scanned volume.

    abstract::The assessment of the radiation dose to internal organs or to an embryo or fetus is required on occasion for risk assessment or for comparing imaging studies. Limited resources hinder the ability to accurately assess the radiation dose received to locations outside the tissue volume actually scanned during computed to...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1312809

    authors: Boone JM,Cooper VN 3rd,Nemzek WR,McGahan JP,Seibert JA

    更新日期:2000-10-01 00:00:00

  • System considerations in CCD-based x-ray imaging for digital chest radiography and digital mammography.

    abstract::System modeling is used to investigate the effect of various system parameters on the image quality in CCD-based x-ray imaging systems. The systems considered consist of a typical phosphor-based scintillating screen coupled to a CCD through lens or fiberoptic taper. Two applications, chest radiography and mammography,...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598072

    authors: Hejazi S,Trauernicht DP

    更新日期:1997-02-01 00:00:00

  • An accelerated threshold-based back-projection algorithm for compton camera image reconstruction.

    abstract:PURPOSE:Compton camera imaging (CCI) systems are currently under investigation for radiotherapy dose reconstruction and verification. The ability of such a system to provide real-time images during dose delivery will be limited by the computational speed of the image reconstruction algorithm. In this work, the authors ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3519873

    authors: Mundy DW,Herman MG

    更新日期:2011-01-01 00:00:00

  • A piecewise-focused high DQE detector for MV imaging.

    abstract:PURPOSE:Electronic portal imagers (EPIDs) with high detective quantum efficiencies (DQEs) are sought to facilitate the use of the megavoltage (MV) radiotherapy treatment beam for image guidance. Potential advantages include high quality (treatment) beam's eye view imaging, and improved cone-beam computed tomography (CB...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4927786

    authors: Star-Lack J,Shedlock D,Swahn D,Humber D,Wang A,Hirsh H,Zentai G,Sawkey D,Kruger I,Sun M,Abel E,Virshup G,Shin M,Fahrig R

    更新日期:2015-09-01 00:00:00

  • SU-E-T-485: Validation of Acuros XB Dose Calculations in SBRT Lung Planning with Monte Carlo Methods.

    abstract:PURPOSE:The Acuros XB (AXB) Advanced Dose algorithm (Varian Medical Systems) represents a dramatic shift in clinical photon dose calculation methodology from pencil-beam superposition/convolution methods. Early studies evaluating the accuracy of the algorithm in lung have found good agreement with both measurement and ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735574

    authors: Bush K,Wang L,Mok E

    更新日期:2012-06-01 00:00:00

  • SU-E-J-41: Fluoroscopy Based Adaptive Setup Approach for Thoracic Cancer IGRT.

    abstract:PURPOSE:To develop a fluoroscopy imaging based approach that can determine the magnitude and phase variation in respiratory motion against the treatment planning images in order to quantify the online patient setup deviation in thoracic cancer IGRT for the real time adaptive patient positionadjustment. METHODS:A numer...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734876

    authors: Chen T,Qin S,Jabbour S,Park J,Haffty B,Yue N

    更新日期:2012-06-01 00:00:00

  • Low-complexity atlas-based prostate segmentation by combining global, regional, and local metrics.

    abstract:PURPOSE:To improve the efficiency of atlas-based segmentation without compromising accuracy, and to demonstrate the validity of the proposed method on MRI-based prostate segmentation application. METHODS:Accurate and efficient automatic structure segmentation is an important task in medical image processing. Atlas-bas...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4867855

    authors: Xie Q,Ruan D

    更新日期:2014-04-01 00:00:00

  • Dynamic field-of-view imaging to increase temporal resolution in the early phase of contrast media uptake in breast DCE-MRI: A feasibility study.

    abstract:PURPOSE:To increase diagnostic accuracy of breast MRI by increasing temporal resolution and more accurately sampling the early kinetics of contrast media uptake. We tested the feasibility of accelerating bilateral breast DCE-MRI by reducing the FOV, allowing aliasing, and unfolding the resulting images. METHODS:Previo...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12747

    authors: Pineda FD,Easley TO,Karczmar GS

    更新日期:2018-03-01 00:00:00

  • Technical Note: Robust individual thermoluminescence dosimeter tracking using optical fingerprinting.

    abstract:PURPOSE:The thermoluminescence dosimeter (TLD) has desirable features including low cost, reusability, small size, and relatively low energy dependence. However, the commonly available poly-crystal TLDs (e.g., TLD-100) exhibit high interdetector variability that requires individual calibration for high detection accura...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13895

    authors: Shang D,Gu W,Landers A,Woods K,Yu V,Neph R,Tenn S,Sheng K

    更新日期:2020-01-01 00:00:00

  • Regularization strategies in statistical image reconstruction of low-dose x-ray CT: A review.

    abstract::Statistical image reconstruction (SIR) methods have shown potential to substantially improve the image quality of low-dose x-ray computed tomography (CT) as compared to the conventional filtered back-projection (FBP) method. According to the maximum a posteriori (MAP) estimation, the SIR methods are typically formulat...

    journal_title:Medical physics

    pub_type: 杂志文章,评审

    doi:10.1002/mp.13123

    authors: Zhang H,Wang J,Zeng D,Tao X,Ma J

    更新日期:2018-10-01 00:00:00

  • Iterative reconstruction method for light emitting sources based on the diffusion equation.

    abstract::Bioluminescent imaging (BLI) of luciferase-expressing cells in live small animals is a powerful technique for investigating tumor growth, metastasis, and specific biological molecular events. Three-dimensional imaging would greatly enhance applications in biomedicine since light emitting cell populations could be unam...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2138007

    authors: Slavine NV,Lewis MA,Richer E,Antich PP

    更新日期:2006-01-01 00:00:00

  • TU-E-217BCD-07: Pilot Study on Consistency in Size Metrics for a Multimodality PEM/MR Breast Imaging Approach.

    abstract:PURPOSE:In this study, we evaluated the degree of consistency between size metrics obtained from PEM and MRI to determine the intrinsic effectiveness of a multimodality approach using these two systems for breast imaging. METHODS:Under an IRB-approved protocol, 42 cases were considered (16 patients with 28 lesions), e...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735979

    authors: Sadinski M,Giger M,Drukker K,Yamaguchi K,Lan L,Li H

    更新日期:2012-06-01 00:00:00

  • Determination of electron energy, spectral width, and beam divergence at the exit window for clinical megavoltage x-ray beams.

    abstract::Monte Carlo simulations of x-ray beams typically take parameters of the electron beam in the accelerating waveguide to be free parameters. In this paper, a methodology is proposed and implemented to determine the energy, spectral width, and beam divergence of the electron source. All treatment head components were rem...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3070547

    authors: Sawkey DL,Faddegon BA

    更新日期:2009-03-01 00:00:00

  • Anniversary paper: evolution of ultrasound physics and the role of medical physicists and the AAPM and its journal in that evolution.

    abstract::Ultrasound has been the greatest imaging modality worldwide for many years by equipment purchase value and by number of machines and examinations. It is becoming increasingly the front end imaging modality; serving often as an extension of the physician's fingers. We believe that at the other extreme, high-end systems...

    journal_title:Medical physics

    pub_type: 杂志文章,评审

    doi:10.1118/1.2992048

    authors: Carson PL,Fenster A

    更新日期:2009-02-01 00:00:00

  • Technical Note: Experimental determination of the effective point of measurement of two cylindrical ionization chambers in a clinical proton beam.

    abstract:PURPOSE:IAEA TRS-398 notes that cylindrical ionization chambers are preferred for reference proton dosimetry. If a cylindrical ionization chamber is used in a phantom to measure the dose as a function of depth, the effective point of measurement (EPOM) must be taken into account. IAEA TRS-398 recommends a displacement ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4921617

    authors: Sugama Y,Nishio T,Onishi H

    更新日期:2015-07-01 00:00:00

  • Performance characteristics of an orthovoltage x-ray therapy machine.

    abstract::Performance characteristics sufficient to provide physical data base specific to the Siemen's Stabilipan 2 orthovoltage x-ray therapy machine are presented. Operating conditions covering the working range of the unit from 100 to 300 kVp are selected. Beam quality, output, the central axis depth dose, relative output f...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596016

    authors: Niroomand-Rad A,Gillin MT,Lopez F,Grimm DF

    更新日期:1987-09-01 00:00:00

  • A moving slanted-edge method to measure the temporal modulation transfer function of fluoroscopic systems.

    abstract::Lag in fluoroscopic systems introduces a frame-averaging effect that reduces measurements of image noise and incorrectly inflates measurements of the detective quantum efficiency (DQE). A correction can be implemented based on measurements of the temporal modulation transfer function (MTF). We introduce a method of me...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2919724

    authors: Friedman SN,Cunningham IA

    更新日期:2008-06-01 00:00:00

  • Development and clinical evaluation of an ionization chamber array with 3.5 mm pixel pitch for quality assurance in advanced radiotherapy techniques.

    abstract:PURPOSE:To characterize a new air vented ionization chamber technology, suitable to build detector arrays with small pixel pitch and independence of sensitivity on dose per pulse. METHODS:The prototype under test is a linear array of air vented ionization chambers, consisting of 80 pixels with 3.5 mm pixel pitch dista...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4945414

    authors: Togno M,Wilkens JJ,Menichelli D,Oechsner M,Perez-Andujar A,Morin O

    更新日期:2016-05-01 00:00:00

  • Radiation attenuation by lead and nonlead materials used in radiation shielding garments.

    abstract::The attenuating properties of several types of lead (Pb)-based and non-Pb radiation shielding materials were studied and a correlation was made of radiation attenuation, materials properties, calculated spectra and ambient dose equivalent. Utilizing the well-characterized x-ray and gamma ray beams at the National Rese...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2426404

    authors: McCaffrey JP,Shen H,Downton B,Mainegra-Hing E

    更新日期:2007-02-01 00:00:00

  • Modeling acute and chronic hypoxia using serial images of 18F-FMISO PET.

    abstract:PURPOSE:Two types of tumor hypoxia most likely exist in human cancers: Chronic hypoxia due to the paucity of blood capillaries and acute hypoxia due to temporary shutdoWn of microvasculatures or fluctuation in the red cell flux. In a recent hypoxia imaging study using 18F-FMISO PET, the authors observed variation in tr...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3213092

    authors: Wang K,Yorke E,Nehmeh SA,Humm JL,Ling CC

    更新日期:2009-10-01 00:00:00

  • Experimental study of humidity effect on charge measurement of reference ionization chambers in clinical high-energy photon beams.

    abstract:PURPOSE:In the practice code of dosimetry, humidity effect is assumed to be constant as far as the measurements are performed in the relative humidity (RH) range of (20-80)%; thus, the humidity effect can be ignored with a dose uncertainty of 0.15%. This assumption is based on the previous experimental results by Niate...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13665

    authors: Sato Y,Shimizu M,Morishita Y,Sato M,Hoshina M

    更新日期:2019-09-01 00:00:00