TU-E-217BCD-07: Pilot Study on Consistency in Size Metrics for a Multimodality PEM/MR Breast Imaging Approach.

Abstract:

PURPOSE:In this study, we evaluated the degree of consistency between size metrics obtained from PEM and MRI to determine the intrinsic effectiveness of a multimodality approach using these two systems for breast imaging. METHODS:Under an IRB-approved protocol, 42 cases were considered (16 patients with 28 lesions), each consisting of an MRI data set and corresponding PEM data set, with an inclusion criterion of being obtained within 2 weeks of each other. Lesions were delineated manually on the PEM images and semi-automatically on the MRI images for efficiency. In addition to volume, equivalent sphere diameter (ESD) was evaluated for each lesion. This metric describes the diameter of a sphere with the same volume as that of the lesion, and is useful for minimizing the cubic impact of a single voxel contribution inherent to volume calculations. RESULTS:The relationship between PEM based volumes and MRI based volumes showed a linear trend around VolMRI=VolPEM demonstrating a degree of consistency in the two volumes. The correlation between VolMRI and VolPEM was calculated as 0.547 with a corresponding p-value of 0.00018 demonstrating a significant correlation. The associated concordance was calculated as 0.534. The ESD metric showed a more significant linear trend with correlation 0.733 and corresponding p-value 3.5×10-8, indicating consistency in lesion size. The concordance is 0.717, indicating high reproducibility. CONCLUSION:Multimodality PEM/MRI breast imaging has the potential to combine functional and molecular imaging information for a powerful tool in cancer staging and evaluation of response to therapy. The resulting, expanded data set is of use only if fundamental size metrics are consistent between the two modalities. Our pilot data demonstrates that size metrics as we extracted from the image data are consistent between PEM and MRI breast image sets.Maryellen Giger is a stockholder in R2 Technology/Hologic, has equity in Quantitative Insights, and receives royalties from Hologic, GE Medical Systems, MEDIAN Technologies, Riverain Medical, Mitsubishi and Toshiba. It is the University of Chicago Conflict of Interest Policy that investigators disclose publicly actual or potential significant financial interest that would reasonably appear to be directly and significantly affected by the research activities.

journal_name

Med Phys

journal_title

Medical physics

authors

Sadinski M,Giger M,Drukker K,Yamaguchi K,Lan L,Li H

doi

10.1118/1.4735979

subject

Has Abstract

pub_date

2012-06-01 00:00:00

pages

3915

issue

6Part24

eissn

0094-2405

issn

2473-4209

journal_volume

39

pub_type

杂志文章
  • Absorbed-dose beam quality conversion factors for cylindrical chambers in high energy photon beams.

    abstract::Recent working groups of the AAPM [Almond et al., Med. Phys. 26, 1847 (1999)] and the IAEA (Andreo et al., Draft V.7 of "An International Code of Practice for Dosimetry based on Standards of Absorbed Dose to Water," IAEA, 2000) have described guidelines to base reference dosimetry of high energy photon beams on absorb...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1328081

    authors: Seuntjens JP,Ross CK,Shortt KR,Rogers DW

    更新日期:2000-12-01 00:00:00

  • Regularization strategies in statistical image reconstruction of low-dose x-ray CT: A review.

    abstract::Statistical image reconstruction (SIR) methods have shown potential to substantially improve the image quality of low-dose x-ray computed tomography (CT) as compared to the conventional filtered back-projection (FBP) method. According to the maximum a posteriori (MAP) estimation, the SIR methods are typically formulat...

    journal_title:Medical physics

    pub_type: 杂志文章,评审

    doi:10.1002/mp.13123

    authors: Zhang H,Wang J,Zeng D,Tao X,Ma J

    更新日期:2018-10-01 00:00:00

  • Heating patterns of microwave applicators in inhomogeneous arm and thigh phantoms.

    abstract::Heating rate (HR) patterns in cylindrical structures were studied with inhomogeneous limb phantoms. These phantoms, arm and thigh models consisting of fat, bone, and muscle material, were heated with Clini-Therm L, M, and MS applicators at 915 MHz. The thigh model is 18 cm in diameter with 2.65-cm-thick fat on the out...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596627

    authors: Chou CK,McDougall JA,Chan KW,Luk KH

    更新日期:1991-11-01 00:00:00

  • A moving blocker system for cone-beam computed tomography scatter correction.

    abstract:PURPOSE:Scatter contamination in cone-beam computed tomography (CBCT) degrades the image quality by introducing shading artifacts. A moving-blocker-based approach has been proposed to simultaneously estimate scatter and reconstruct the complete volume within field of view (FOV) from a single CBCT scan. Promising result...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4811086

    authors: Ouyang L,Song K,Wang J

    更新日期:2013-07-01 00:00:00

  • On the accuracy of techniques for obtaining the calibration coefficient N(K) of 192Ir HDR brachytherapy sources.

    abstract::The accuracy of interpolation or averaging procedures for obtaining the calibration coefficient N(K) for 192Ir high-dose-rate brachytherapy sources has been investigated using the EGSnrc Monte Carlo simulation system. It is shown that the widely used two-point averaging procedure of Goetsch et al. [Med. Phys. 18, 462 ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2239198

    authors: Mainegra-Hing E,Rogers DW

    更新日期:2006-09-01 00:00:00

  • Comment on: Polarity effects and apparent ion recombination in microionization chambers Med. Phys. 43(5), 2141-2152 (2016).

    abstract::In a recent paper of Miller et al. (Med. Phys. 43(5), 2141-2152 (2016), the voltage dependence polarity effect of microionization chambers was studied. It was identified that polarity effect arises from the difference in electric potential between the collecting electrode and the guard electrode, which in turn deforms...

    journal_title:Medical physics

    pub_type: 信件

    doi:10.1002/mp.12019

    authors: Brivio D,Sajo E,Zygmanski P

    更新日期:2017-03-01 00:00:00

  • Comparison of two independent exposure measurement techniques for clinical I-125 seeds.

    abstract::This investigation contains the results of exposure measurements on two types of clinical I-125 seeds: a model 6702 no-marker seed, and a model 6711 silver wire seed. Measurements were made locally with a parallel-plate mammography chamber, traceable to the National Bureau of Standards (NBS) calibration. The same seed...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595784

    authors: Kubo H

    更新日期:1985-03-01 00:00:00

  • Automatic detection of simulated motion blur in mammograms.

    abstract:PURPOSE:To use machine-learning algorithms and blur measure (BM) operators to automatically detect motion blur in mammograms. Motion blur has been reported to reduce lesion detection performance and mask small abnormalities, resulting in failure to detect them until they reach more advanced stages. Automatic detection ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14069

    authors: Kamona N,Loew M

    更新日期:2020-04-01 00:00:00

  • Characterization of scintillator-based detectors for few-ten-keV high-spatial-resolution x-ray imaging.

    abstract:PURPOSE:High-spatial-resolution x-ray imaging in the few-ten-keV range is becoming increasingly important in several applications, such as small-animal imaging and phase-contrast imaging. The detector properties critically influence the quality of such imaging. Here the authors present a quantitative comparison of scin...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4948687

    authors: Larsson JC,Lundström U,Hertz HM

    更新日期:2016-06-01 00:00:00

  • Region-oriented CT image representation for reducing computing time of Monte Carlo simulations.

    abstract:PURPOSE:We propose a new method for efficient particle transportation in voxelized geometry for Monte Carlo simulations. We describe its use for calculating dose distribution in CT images for radiation therapy. MATERIAL AND METHODS:The proposed approach, based on an implicit volume representation named segmented volum...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2884854

    authors: Sarrut D,Guigues L

    更新日期:2008-04-01 00:00:00

  • Investigation of spectral performance for single-scan contrast-enhanced breast CT using photon-counting technology: A phantom study.

    abstract:PURPOSE:Contrast-enhanced imaging of the breast is frequently used in breast MRI and has recently become more common in mammography. The purpose of this study was to make single-scan contrast-enhanced imaging feasible for photon-counting breast CT (pcBCT) and to assess the spectral performance of a pcBCT scanner by eva...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14133

    authors: Ruth V,Kolditz D,Steiding C,Kalender WA

    更新日期:2020-07-01 00:00:00

  • Recent progress in x-ray stereoscopes.

    abstract::An improved reconstructed stereoscopic x-ray image display system, based on the principle of binocular parallax, is described. Pulse-synchronized operation of two triode x-ray tubes and one plumbicon TV camera is employed to separate the left and right images for presentation to the two eyes, respectively. The princip...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595365

    authors: Zhang S,King PH,Pang XD

    更新日期:1983-09-01 00:00:00

  • Optical image processing with liquid-crystal display for image intensifier/television systems.

    abstract::We have studied the effect of real-time optical image processing (OIP) in an image intensifier/television (II-TV) radiographic imaging system by using a liquid-crystal display (LCD) placed between the II and the TV camera. The LCD compresses the dynamic range of the transmitted image by modulating the spatial distribu...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596199

    authors: Lam KL,Chan HP,Doi K

    更新日期:1988-11-01 00:00:00

  • Application of high field magnetic resonance microimaging in polymer gel dosimetry.

    abstract:PURPOSE:The purpose of this work was to examine the suitability of VIPARnd polymer gel-9.4 T magnetic resonance microimaging system for high spatial resolution dose distribution measurements. METHODS:The VIPARnd samples (3 cm in outside diameter and 12 cm in height) were exposed to ionizing radiation by using a linear...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14186

    authors: Skorupa A,Woźnica A,Ciszek M,Staniszewski M,Kijonka M,Kozicki M,Woźniak B,Orlef A,Polański A,Boguszewicz Ł,Sokół M

    更新日期:2020-08-01 00:00:00

  • Direct-response ultraviolet thermoluminescent dosimeter.

    abstract::An integrating solid-state dosimeter has been developed to detect ultraviolet radiation using the process of "direct" ultraviolet stimulation. This process yields a thermoluminescent signal after an exposure to ultraviolet radiation, without prior exposure to ionizing radiation. Magnesium oxide crystals were found to ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594259

    authors: Dhar A,DeWerd LA,Stoebe TG

    更新日期:1976-11-01 00:00:00

  • Microdosimetric study for secondary neutrons in phantom produced by a 290 MeV/nucleon carbon beam.

    abstract::Absorbed doses from main charged-particle beams and charged-particle fragments have been measured with high accuracy for particle therapy, but there are few reports for doses from neutron components produced as fragments. This study describes the measurements on neutron doses produced by carbon beams; microdosimetric ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2767933

    authors: Endo S,Tanaka K,Takada M,Onizuka Y,Miyahara N,Sato T,Ishikawa M,Maeda N,Hayabuchi N,Shizuma K,Hoshi M

    更新日期:2007-09-01 00:00:00

  • Assessment of image registration accuracy in three-dimensional transrectal ultrasound guided prostate biopsy.

    abstract:PURPOSE:Prostate biopsy, performed using two-dimensional (2D) transrectal ultrasound (TRUS) guidance, is the clinical standard for a definitive diagnosis of prostate cancer. Histological analysis of the biopsies can reveal cancerous, noncancerous, or suspicious, possibly precancerous, tissue. During subsequent biopsy s...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3298010

    authors: Karnik VV,Fenster A,Bax J,Cool DW,Gardi L,Gyacskov I,Romagnoli C,Ward AD

    更新日期:2010-02-01 00:00:00

  • Electron beam water calorimetry measurements to obtain beam quality conversion factors.

    abstract:PURPOSE:To provide results of water calorimetry and ion chamber measurements in high-energy electron beams carried out at the National Research Council Canada (NRC). There are three main aspects to this work: (a) investigation of the behavior of ionization chambers in electron beams of different energies with focus on ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12463

    authors: Muir BR,Cojocaru CD,McEwen MR,Ross CK

    更新日期:2017-10-01 00:00:00

  • A simple model for transit dosimetry based on a water equivalent EPID.

    abstract:PURPOSE:The aim of this study was to demonstrate a new model for implementing a transit dosimetry system as a means of in vivo dose verification with a water equivalent electronic portal imaging device (WE-EPID) and a conventional treatment planning system (TPS). METHOD AND MATERIALS:A standard amorphous silicon (a-Si...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12742

    authors: Deshpande S,Blake SJ,Xing A,Metcalfe PE,Holloway LC,Vial P

    更新日期:2018-03-01 00:00:00

  • Fully automatic deformable registration of pretreatment MRI/CT for image-guided prostate radiotherapy planning.

    abstract:PURPOSE:In prostate radiotherapy, dose distribution may be calculated on CT images, while the MRI can be used to enhance soft tissue visualization. Therefore, a registration between MR and CT images could improve the overall treatment planning process, by improving visualization with a demonstrated interobserver deline...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12629

    authors: Hamdan I,Bert J,Rest CCL,Tasu JP,Boussion N,Valeri A,Dardenne G,Visvikis D

    更新日期:2017-12-01 00:00:00

  • Detecting electron beam energy shifts with a commercially available energy monitor.

    abstract::Routine electron beam quality assurance requires an accurate, yet practical, method of energy characterization. Subtle shifts in beam energy may be produced by the linac bending magnet assembly, and the sensitivity of a commercially available electron beam energy-monitoring device for monitoring these small energy dri...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.599033

    authors: Evans MD,Moftah BA,Olivares M,Podgorsak EB

    更新日期:2000-07-01 00:00:00

  • Statistical variability and confidence intervals for planar dose QA pass rates.

    abstract:PURPOSE:The most common metric for comparing measured to calculated dose, such as for pretreatment quality assurance of intensity-modulated photon fields, is a pass rate (%) generated using percent difference (%Diff), distance-to-agreement (DTA), or some combination of the two (e.g., gamma evaluation). For many dosimet...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3651695

    authors: Bailey DW,Nelms BE,Attwood K,Kumaraswamy L,Podgorsak MB

    更新日期:2011-11-01 00:00:00

  • Choice of material for HVL measurements in megavoltage x-ray beams.

    abstract::The relative sensitivity of the half-value layer (HVL) method as a quality index for megavoltage x-ray beams is examined by theoretical calculation and experimental measurements for 4-, 6-, 10-, and 25-MV x-ray beams. It is shown that lower atomic number materials are more sensitive to beam quality changes than higher...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595794

    authors: Meli JA,Nath R

    更新日期:1985-01-01 00:00:00

  • Toward consensus on quantitative assessment of medical imaging systems.

    abstract::Consensus has been developing over the past few decades on a number of measurements required for the laboratory assessment of medical imaging modalities. Nevertheless, understanding of the connection between these measurements and human observer performance in a broad range of tasks remains far from complete. Focusing...

    journal_title:Medical physics

    pub_type: 杂志文章,评审

    doi:10.1118/1.597511

    authors: Metz CE,Wagner RF,Doi K,Brown DG,Nishikawa RM,Myers KJ

    更新日期:1995-07-01 00:00:00

  • SU-E-I-32: Sterile Radiation Reduction Gloves May Be Contraindicated in Fluoroscopically Guided Interventions.

    abstract:PURPOSE:Sterile radiation reduction gloves have been widely used in the past decade to provide modest decreases in operator hand dose when the hands are placed in the field of view (FOV). While multiple publications have quantified the potential dose reduction from the use of such gloves, possible effects on the patien...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734747

    authors: Pasciak A,Neveu M,Sriharan A,Balius A,Jones A

    更新日期:2012-06-01 00:00:00

  • Accuracy of respiratory motion measurement of 4D-MRI: A comparison between cine and sequential acquisition.

    abstract:PURPOSE:The authors have recently developed a cine-mode T2*/T1-weighted 4D-MRI technique and a sequential-mode T2-weighted 4D-MRI technique for imaging respiratory motion. This study aims at investigating which 4D-MRI image acquisition mode, cine or sequential, provides more accurate measurement of organ motion during ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4938066

    authors: Liu Y,Yin FF,Rhee D,Cai J

    更新日期:2016-01-01 00:00:00

  • Application of spherical diodes for megavoltage photon beams dosimetry.

    abstract:PURPOSE:External beam radiation therapy (EBRT) usually uses heterogeneous dose distributions in a given volume. Designing detectors for quality control of these treatments is still a developing subject. The size of the detectors should be small to enhance spatial resolution and ensure low perturbation of the beam. A hi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4837178

    authors: Barbés B,Azcona JD,Burguete J,Martí-Climent JM

    更新日期:2014-01-01 00:00:00

  • Experimental study of the relationship between the base impedance and its time derivative in impedance plethysmography.

    abstract::Transthoracic electrical impedance Z consists of a constant baseline component Z0 and the time variable component delta Z such that Z = Z0 + delta Z. The first time derivative of Z has a negative peak, the magnitude of which is (dZ/dt)min. Measurements of 170 volunteers show that (dZ/dt)min is a function of the consta...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594910

    authors: Djordjevich L,Sadove MS

    更新日期:1981-01-01 00:00:00

  • Evaluation of video gray-scale display.

    abstract::Setting up and maintaining video display monitors properly will help to reduce display variation and improve overall presentation of the radiological image. Display monitor gray-scale characteristics were examined using the SMPTE test pattern. This test pattern may be used as a standard for adjusting brightness and co...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596846

    authors: Nawfel RD,Chan KH,Wagenaar DJ,Judy PF

    更新日期:1992-05-01 00:00:00

  • Rigid 2D/3D slice-to-volume registration and its application on fluoroscopic CT images.

    abstract::Registration of single slices from FluoroCT, CineMR, or interventional magnetic resonance imaging to three dimensional (3D) volumes is a special aspect of the two-dimensional (2D)/3D registration problem. Rather than digitally rendered radiographs (DRR), single 2D slice images obtained during interventional procedures...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2401661

    authors: Birkfellner W,Figl M,Kettenbach J,Hummel J,Homolka P,Schernthaner R,Nau T,Bergmann H

    更新日期:2007-01-01 00:00:00