A moving blocker system for cone-beam computed tomography scatter correction.

Abstract:

PURPOSE:Scatter contamination in cone-beam computed tomography (CBCT) degrades the image quality by introducing shading artifacts. A moving-blocker-based approach has been proposed to simultaneously estimate scatter and reconstruct the complete volume within field of view (FOV) from a single CBCT scan. Promising results were obtained from our simulation studies. In this work, the authors demonstrated experimentally the effectiveness of the moving-blocker-based scatter correction approach by implementing a moving blocker system on a LINAC on-board kV CBCT imaging system. METHODS:A physical attenuator (i.e., "blocker") consisting of equal spaced lead strips was mounted on a linear actuator. A step motor connected to the actuator drove the blocker to move back and forth along gantry rotation axis during the CBCT acquisition. Scatter signal was estimated from the blocked region of imaging panel, and interpolated into the unblocked region. A statistics-based iterative image reconstruction algorithm was used to reconstruct CBCT images from unblocked projections after the scatter signal was subtracted. Experimental studies were performed on a Catphan phantom and an anthropomorphic pelvis phantom to evaluate performance of the moving blocker system. RESULTS:The scatter-induced shading artifacts were substantially reduced in the images acquired with the moving blocker system. CT number error in selected regions of interest reduced from 318 to 17 and from 239 to 10 for the Catphan phantom and pelvis phantom, respectively. CONCLUSIONS:The authors demonstrated experimentally that the moving blocker system can successfully estimate the scatter signal in projection data and obtain complete volumetric information within the FOV using a single scan.

journal_name

Med Phys

journal_title

Medical physics

authors

Ouyang L,Song K,Wang J

doi

10.1118/1.4811086

subject

Has Abstract

pub_date

2013-07-01 00:00:00

pages

071903

issue

7

eissn

0094-2405

issn

2473-4209

journal_volume

40

pub_type

杂志文章
  • False-positive reduction in CAD mass detection using a competitive classification strategy.

    abstract::High false-positive (FP) rate remains to be one of the major problems to be solved in CAD study because too many false-positively cued signals will potentially degrade the performance of detecting true-positive regions and increase the call-back rate in CAD environment. In this paper, we proposed a novel classificatio...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1344203

    authors: Li L,Zheng Y,Zhang L,Clark RA

    更新日期:2001-02-01 00:00:00

  • The use of a diode matrix in commissioning activities for electron energies > or = 9 MeV: a feasibility study.

    abstract::The contribution of a commercially available diode matrix (MapCHECK, provided by Sun Nuclear, Melbourne, FL) for the commissioning procedures of the voxel based Monte Carlo (VMC++) algorithm for electron beams of MasterPlan treatment planning system was investigated. The attention is mainly focused on the calculation ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3081414

    authors: Borca VC,Pasquino M,Ozzello F,Tofani S

    更新日期:2009-04-01 00:00:00

  • Quantification with a dedicated breast PET/CT scanner.

    abstract:PURPOSE:Dedicated breast PET/CT is expected to have utility in local staging, surgical planning, monitoring of therapy response, and detection of residual disease for breast cancer. Quantitative metrics will be integral to several such applications. The authors present a validation of fully 3D data correction schemes f...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3703593

    authors: Bowen SL,Ferrero A,Badawi RD

    更新日期:2012-05-01 00:00:00

  • Robotic intrafractional US guidance for liver SABR: System design, beam avoidance, and clinical imaging.

    abstract:PURPOSE:To present a system for robotic 4D ultrasound (US) imaging concurrent with radiotherapy beam delivery and estimate the proportion of liver stereotactic ablative body radiotherapy (SABR) cases in which robotic US image guidance can be deployed without interfering with clinically used VMAT beam configurations. M...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4964454

    authors: Schlosser J,Gong RH,Bruder R,Schweikard A,Jang S,Henrie J,Kamaya A,Koong A,Chang DT,Hristov D

    更新日期:2016-11-01 00:00:00

  • The effects of the imaging system on the validity limits of the ray-optical approach to phase contrast imaging.

    abstract::A theoretical analysis of the x-ray phase contrast imaging and its validation via synchrotron radiation imaging is here presented. Two different mathematical models have been followed: the simpler ray-optical approach and the more rigorous Fresnel-Kirchoff diffraction theory. Subsequently, the conditions upon which th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2126207

    authors: Peterzol A,Olivo A,Rigon L,Pani S,Dreossi D

    更新日期:2005-12-01 00:00:00

  • Feasibility study on inverse four-dimensional dose reconstruction using the continuous dose-image of EPID.

    abstract:PURPOSE:When an intensity-modulated radiation beam is delivered to a moving target, the interplay effect between dynamic beam delivery and the target motion due to miss-synchronization can cause unpredictable dose delivery. The portal dose image in electronic portal imaging device (EPID) represents radiation attenuated...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4799941

    authors: Yeo IJ,Jung JW,Yi BY,Kim JO

    更新日期:2013-05-01 00:00:00

  • Effect of T1-mapping technique and diminished image resolution on quantification of infarct mass and its ability in predicting appropriate ICD therapy.

    abstract:PURPOSE:Myocardial infarct (MI) may consist of an infarct core (IC) and a heterogeneous, semi-viable border zone (BZ). Patients with chronic MI in the left ventricular (LV) myocardium are at increased risk of developing ventricular arrhythmias, and may therefore qualify for implantable cardioverter defibrillator (ICD) ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12840

    authors: Farrag NA,Ramanan V,Wright GA,Ukwatta E

    更新日期:2018-04-01 00:00:00

  • Evaluation of inherent gray-level dynamic range in a digital image using the runs test and join-count statistics.

    abstract::The dynamic range of the gray level of a digital image is limited by the noise it contains. Two statistical methods called "runs test" and "join-count statistic" are used to measure the noise level in a digital image. A residual image is formed by subtracting an original image from its smoothed version. Theoretically,...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597058

    authors: Chuang KS,Huang HK

    更新日期:1993-01-01 00:00:00

  • A Monte Carlo approach to validation of FFF VMAT treatment plans for the TrueBeam linac.

    abstract:PURPOSE:To commission and benchmark a vendor-supplied (Varian Medical Systems) Monte Carlo phase-space data for the 6 MV flattening filter free (FFF) energy mode on a TrueBeam linear accelerator for the purpose of quality assurance of clinical volumetric modulated arc therapy (VMAT) treatment plans. A method for render...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4773883

    authors: Gete E,Duzenli C,Milette MP,Mestrovic A,Hyde D,Bergman AM,Teke T

    更新日期:2013-02-01 00:00:00

  • Direct-conversion flat-panel imager with avalanche gain: feasibility investigation for HARP-AMFPI.

    abstract::The authors are investigating the concept of a direct-conversion flat-panel imager with avalanche gain for low-dose x-ray imaging. It consists of an amorphous selenium (a-Se) photoconductor partitioned into a thick drift region for x-ray-to-charge conversion and a relatively thin region called high-gain avalanche rush...

    journal_title:Medical physics

    pub_type: 杂志文章,评审

    doi:10.1118/1.3002314

    authors: Wronski MM,Rowlands JA

    更新日期:2008-12-01 00:00:00

  • An accurate method for direct dual-energy calibration and decomposition.

    abstract::We propose the use of conic and cubic surface equations (surfaces of second and third order) to directly approximate the dual-energy equations (the integral equations for the dual-energy log-signal functions, i.e., the negative logarithms of the relative detector signals, considered as functions of the basis-material ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596512

    authors: Cardinal HN,Fenster A

    更新日期:1990-05-01 00:00:00

  • A multimodality segmentation framework for automatic target delineation in head and neck radiotherapy.

    abstract:PURPOSE:To develop an automatic segmentation algorithm integrating imaging information from computed tomography (CT), positron emission tomography (PET), and magnetic resonance imaging (MRI) to delineate target volume in head and neck cancer radiotherapy. METHODS:Eleven patients with unresectable disease at the tonsil...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4928485

    authors: Yang J,Beadle BM,Garden AS,Schwartz DL,Aristophanous M

    更新日期:2015-09-01 00:00:00

  • SU-E-J-139: Feasibility of Using EPID for Real-Time Target Localization during Treatment.

    abstract:PURPOSE:This study aims to investigate the feasibility of using the images of the treatment fields acquired by an electronic portal imaging device (EPID) for real-time target localization. METHODS:Forty one patients treated with IMRT and RapidArc were recruited in this study including 37 prostate patients and 4 lung p...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734975

    authors: Xu Q,Lin M,Chen X,Tong X,Fan J,Dong Z,Chen L,Ma C

    更新日期:2012-06-01 00:00:00

  • Comparison of p-type commercial electron diodes for in vivo dosimetry.

    abstract::This paper compares the characteristics of three types of commercial p-type electron diodes specially designed for in vivo dosimetry (Scanditronix EDD2, Sun Nuclear QED 111200-0 and PTW T60010E diodes coupled with a Therados DPD510 dosimeter) in electron fields with energies from 4.5 to 21 MeV, and in conditions simil...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1630492

    authors: Marre D,Marinello G

    更新日期:2004-01-01 00:00:00

  • Automated segmentation of lungs with severe interstitial lung disease in CT.

    abstract:PURPOSE:Accurate segmentation of lungs with severe interstitial lung disease (ILD) in thoracic computed tomography (CT) is an important and difficult task in the development of computer-aided diagnosis (CAD) systems. Therefore, we developed in this study a texture analysis-based method for accurate segmentation of lung...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3222872

    authors: Wang J,Li F,Li Q

    更新日期:2009-10-01 00:00:00

  • Spectrally resolved bioluminescence tomography using the reciprocity approach.

    abstract::Spectrally resolved bioluminescence optical tomography is an approach to recover images of, for example, Luciferase activity within a volume using multiwavelength emission data from internal bioluminescence sources. The underlying problem of uniqueness associated with nonspectrally resolved intensity-based bioluminesc...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2982138

    authors: Dehghani H,Davis SC,Pogue BW

    更新日期:2008-11-01 00:00:00

  • Neutron energies in medical electron accelerator rooms.

    abstract::Two experimental methods are described for obtaining average energies of neutron spectra produced by an electron accelerator in a medical treatment room. In the first method, the dose equivalent is measured by means of indium activation foils in an Andersson-Braun moderator. Fluences are determined by the usual activa...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595662

    authors: LaRiviere PD

    更新日期:1985-11-01 00:00:00

  • A generic TG-186 shielded applicator for commissioning model-based dose calculation algorithms for high-dose-rate 192 Ir brachytherapy.

    abstract:PURPOSE:A joint working group was created by the American Association of Physicists in Medicine (AAPM), the European Society for Radiotherapy and Oncology (ESTRO), and the Australasian Brachytherapy Group (ABG) with the charge, among others, to develop a set of well-defined test case plans and perform calculations and ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12459

    authors: Ma Y,Vijande J,Ballester F,Tedgren ÅC,Granero D,Haworth A,Mourtada F,Fonseca GP,Zourari K,Papagiannis P,Rivard MJ,Siebert FA,Sloboda RS,Smith R,Chamberland MJP,Thomson RM,Verhaegen F,Beaulieu L

    更新日期:2017-11-01 00:00:00

  • High correlation between radiation dose estimates for 256-slice CT obtained by highly parallelized hybrid Monte Carlo computation and solid-state metal-oxide semiconductor field-effect transistor measurements in physical anthropomorphic phantoms.

    abstract:PURPOSE:Accurate, patient-specific radiation dosimetry for CT scanning is critical to optimize radiation doses and balance dose against image quality. While Monte Carlo (MC) simulation is often used to estimate doses from CT, comparison of estimates to experimentally measured values is lacking for advanced CT scanners ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13780

    authors: Prinsen P,Trattner S,Wiegert J,Gerland EL,Shefer E,Morton T,Thompson CM,Cheng B,Halliburton SS,Einstein AJ

    更新日期:2019-11-01 00:00:00

  • Technical Note: Impact of the geometry dependence of the ion chamber detector response function on a convolution-based method to address the volume averaging effect.

    abstract:PURPOSE:To investigate the geometry dependence of the detector response function (DRF) of three commonly used scanning ionization chambers and its impact on a convolution-based method to address the volume averaging effect (VAE). METHODS:A convolution-based approach has been proposed recently to address the ionization...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4944783

    authors: Barraclough B,Li JG,Lebron S,Fan Q,Liu C,Yan G

    更新日期:2016-05-01 00:00:00

  • Poster - Thur Eve - 18: Characterization of a camera and LED lightbox imaging system for radiochromic film dosimetry.

    abstract::Radiation therapy treatment modalities continue to develop and have become increasingly complex. With this, dose verification and quality assurance (QA) is of great importance to ensure that a prescribed dose is accurately and precisely delivered to a patient. Radiochromic film dosimetry has been adopted as a convenie...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4740126

    authors: Alexander K,Percy E,Olding T,Schreiner LJ,Salomons G

    更新日期:2012-07-01 00:00:00

  • Development of an automated region of interest selection method for 3D surface monitoring of head motion.

    abstract:PURPOSE:To simplify the often complex and user-dependent manual region of interest (ROI) selection process for head motion monitoring, an automatic ROI selection method was developed. METHODS:The automatic ROI selection algorithm calculated the displacements and velocities of 3D surface points between a temporally cor...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4711805

    authors: Kang HJ,Grelewicz Z,Wiersma RD

    更新日期:2012-06-01 00:00:00

  • Experimental determination of the "collimator monitoring fill factor" and its relation to the error detection capabilities of various 2D-arrays.

    abstract:PURPOSE:The collimator monitoring fill factor (CM-FF) introduced by Stelljes et al. (2017) and the FWHM fill factor (FWHM-FF) introduced by Gago-Arias et al. (2012) were determined using the measured photon fluence response functions of various 2D-arrays. The error detection capabilities of 2D-arrays were studied by co...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13417

    authors: Stelljes TS,Poppinga D,Kretschmer J,Brodbek L,Looe HK,Poppe B

    更新日期:2019-04-01 00:00:00

  • FRoG: An independent dose and LETd prediction tool for proton therapy at ProBeam® facilities.

    abstract:PURPOSE:Particle therapy is becoming increasingly available world-wide for precise tumor targeting, its favorable depth dose deposition, and increased biological damage to tumor tissue compared to conventional photon therapy. As demand increases for improved robustness and conformality, next-generation secondary dose c...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14417

    authors: Kopp B,Fuglsang Jensen M,Mein S,Hoffmann L,Nyström H,Falk M,Haberer T,Abdollahi A,Debus J,Mairani A

    更新日期:2020-10-01 00:00:00

  • Reduction of peak acoustic pressure and shaping of heated region by use of multifoci sonications in MR-guided high-intensity focused ultrasound mediated mild hyperthermia.

    abstract:PURPOSE:Ablative hyperthermia (>55 °C) has been used as a definitive treatment for accessible solid tumors not amenable to surgery, whereas mild hyperthermia (40-45 °C) has been shown effective as an adjuvant for both radiotherapy and chemotherapy. An optimal mild hyperthermia treatment is spatially accurate, with prec...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4769116

    authors: Partanen A,Tillander M,Yarmolenko PS,Wood BJ,Dreher MR,Kohler MO

    更新日期:2013-01-01 00:00:00

  • Lung morphometry using hyperpolarized 129 Xe multi-b diffusion MRI with compressed sensing in healthy subjects and patients with COPD.

    abstract:PURPOSE:To demonstrate the feasibility of compressed sensing (CS) to accelerate the acquisition of hyperpolarized (HP) 129 Xe multi-b diffusion MRI for quantitative assessments of lung microstructural morphometry. METHODS:Six healthy subjects and six chronic obstructive pulmonary disease (COPD) subjects underwent HP 1...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12944

    authors: Zhang H,Xie J,Xiao S,Zhao X,Zhang M,Shi L,Wang K,Wu G,Sun X,Ye C,Zhou X

    更新日期:2018-07-01 00:00:00

  • Benchmarking analytical calculations of proton doses in heterogeneous matter.

    abstract::A proton dose computational algorithm, performing an analytical superposition of infinitely narrow proton beamlets (ASPB) is introduced. The algorithm uses the standard pencil beam technique of laterally distributing the central axis broad beam doses according to the Moliere scattering theory extended to slablike vary...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2064887

    authors: Ciangaru G,Polf JC,Bues M,Smith AR

    更新日期:2005-12-01 00:00:00

  • Comparison of radiograph-based texture analysis and bone mineral density with three-dimensional microarchitecture of trabecular bone.

    abstract:PURPOSE:Hip fracture is a serious health problem and textural methods are being developed to assess bone quality. The authors aimed to perform textural analysis at femur on high-resolution digital radiographs compared to three-dimensional (3D) microarchitecture comparatively to bone mineral density. METHODS:Sixteen ca...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3528125

    authors: Ranjanomennahary P,Ghalila SS,Malouche D,Marchadier A,Rachidi M,Benhamou C,Chappard C

    更新日期:2011-01-01 00:00:00

  • A comparison of the physical imaging properties of Fuji ST-V, ST-VA, and ST-VN computed radiography image plates.

    abstract::The physical imaging performance of ST-V, ST-VA, and ST-VN computed radiography image plates, read with a Philips AC3 acquisition system, was investigated at 70 kVp with 0.5 mm of copper beam filtration for four different entrance air kerma values: 0.5, 2.6, 26, and 260 micro Gy. Measurements included characteristic r...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598412

    authors: Kengyelics SM,Davies AG,Cowen AR

    更新日期:1998-11-01 00:00:00

  • An inexpensive kVp penetrameter.

    abstract::In this report we describe an improvement upon the design by Stanton and Lightfoot for a simple photographic null method to determine the kVp of a diagnostic region x-ray source. The new version has two primary advantages over the Ardran and Crooks design in that it is both simpler and less expensive to produce. ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595716

    authors: Netto TG,Cameron JR

    更新日期:1985-03-01 00:00:00