Quantification with a dedicated breast PET/CT scanner.

Abstract:

PURPOSE:Dedicated breast PET/CT is expected to have utility in local staging, surgical planning, monitoring of therapy response, and detection of residual disease for breast cancer. Quantitative metrics will be integral to several such applications. The authors present a validation of fully 3D data correction schemes for a custom built dedicated breast PET/CT (DbPET/CT) scanner via (18)F-FDG phantom scans. METHODS:A component-based normalization was implemented, live-time was estimated with a multicomponent model, and a variance reduced randoms estimate was computed from delayed coincidences. Attenuation factors were calculated by using a CT based segmentation scheme while scatter was computed using a Monte Carlo (MC) simulation method. As no performance standard currently exists for breast PET systems, custom performance tests were created based on prior patient imaging results. Count-rate linearity for live-time and randoms corrections was measured with a decay experiment for a solid polyethylene cylinder phantom with an offset line source. A MC simulation was used to validate attenuation correction, a multicompartment phantom with asymmetric activity distribution provided an assessment of scatter correction, and image uniformity after geometric and detector normalization was measured from a high count scan of a uniform cylinder phantom. Raw data were reconstructed with filtered back projection (FBP) after Fourier rebinning. To quantify performance absolute activity concentrations, contrast recovery coefficients and image uniformity were calculated through region of interest analysis. RESULTS:The most significant source of error was attributed to mispositioning of events due to pile-up, presenting in count-related axial and transaxial nonuniformities that were not corrected for with the normalization method used here. Within the range of singles counts observed during clinical trials residual error after applying all corrections was comparable to that of a commercial whole body PET/CT system. CONCLUSIONS:The results suggest that DbPET/CT is capable of producing quantitative images under the operating conditions expected during patient imaging.

journal_name

Med Phys

journal_title

Medical physics

authors

Bowen SL,Ferrero A,Badawi RD

doi

10.1118/1.3703593

subject

Has Abstract

pub_date

2012-05-01 00:00:00

pages

2694-707

issue

5

eissn

0094-2405

issn

2473-4209

journal_volume

39

pub_type

杂志文章
  • Half-scan cone-beam CT fluoroscopy with multiple x-ray sources.

    abstract::To develop volumetric micro-CT fluoroscopy for small animal imaging, we have proposed a cone-beam system with multiple x-ray sources. In this paper, we extend Parker's single-source half-scan weighting scheme to the case of an odd number of x-ray sources that are equiangularly distributed, and apply it for half-scan F...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1381549

    authors: Liu Y,Liu H,Wang Y,Wang G

    更新日期:2001-07-01 00:00:00

  • Experimental study of the relationship between the base impedance and its time derivative in impedance plethysmography.

    abstract::Transthoracic electrical impedance Z consists of a constant baseline component Z0 and the time variable component delta Z such that Z = Z0 + delta Z. The first time derivative of Z has a negative peak, the magnitude of which is (dZ/dt)min. Measurements of 170 volunteers show that (dZ/dt)min is a function of the consta...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594910

    authors: Djordjevich L,Sadove MS

    更新日期:1981-01-01 00:00:00

  • Technical Note: Influence of Compton currents on profile measurements in small-volume ion chambers.

    abstract:PURPOSE:This work is to evaluate the effects of Compton current generation in three small-volume ionization chambers on measured beam characteristics for electron fields. METHODS:Beam scans were performed using Exradin A16, A26, and PTW 31014 microchambers. Scans with varying chamber components shielded were performed...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4929555

    authors: Tanny S,Holmes S,Sperling N,Parsai EI

    更新日期:2015-10-01 00:00:00

  • Vision 20/20: Magnetic resonance imaging-guided attenuation correction in PET/MRI: Challenges, solutions, and opportunities.

    abstract::Attenuation correction is an essential component of the long chain of data correction techniques required to achieve the full potential of quantitative positron emission tomography (PET) imaging. The development of combined PET/magnetic resonance imaging (MRI) systems mandated the widespread interest in developing nov...

    journal_title:Medical physics

    pub_type: 杂志文章,评审

    doi:10.1118/1.4941014

    authors: Mehranian A,Arabi H,Zaidi H

    更新日期:2016-03-01 00:00:00

  • Establishment of technical prerequisites for cell irradiation experiments with laser-accelerated electrons.

    abstract:PURPOSE:In recent years, laser-based acceleration of charged particles has rapidly progressed and medical applications, e.g., in radiotherapy, might become feasible in the coming decade. Requirements are monoenergetic particle beams with long-term stable and reproducible properties as well as sufficient particle intens...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3301598

    authors: Beyreuther E,Enghardt W,Kaluza M,Karsch L,Laschinsky L,Lessmann E,Nicolai M,Pawelke J,Richter C,Sauerbrey R,Schlenvoigt HP,Baumann M

    更新日期:2010-04-01 00:00:00

  • In vitro in-stent restenoses evaluated by 3D ultrasound.

    abstract::The purpose of this study was to quantify in-stent restenoses with 3D B mode and power Doppler ultrasound (U.S.) imaging. In-stent restenoses were mimicked with vascular phantoms in which a nonferromagnetic prototype stent (Boston Scientific) and a ferromagnetic clinical stainless steel stent (Palmaz P295) were embedd...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3062944

    authors: Lécart M,Cardinal MH,Qin Z,Soulez G,Cloutier G

    更新日期:2009-02-01 00:00:00

  • Scatter-glare correction using a convolution algorithm with variable weighting.

    abstract::Several investigators have approximated the scatter component of digital radiographic images by applying a constant weighting factor to a convolved version of the detected image. The scatter approximation is then subtracted from the detected image. When a constant weighting factor is used, the scatter in areas of low ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596088

    authors: Naimuddin S,Hasegawa B,Mistretta CA

    更新日期:1987-05-01 00:00:00

  • An independent algorithm to check the monitor units calculation in radiosurgery.

    abstract::Double checking of the monitor units (MU) is an important step in the quality assurance (QA) process in radiosurgery. In this paper we propose the use of an independent algorithm constructed using the ellipsoid which best fits the measurements taken with the bubble head frame. The monitor units calculated by this inde...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2815361

    authors: Ramos LI,Monge RM,Aristu JJ,Moreno LA

    更新日期:2008-01-01 00:00:00

  • Influence of 0.35 T magnetic field on the response of EBT3 and EBT-XD radiochromic films.

    abstract:PURPOSE:To investigate the inconsistency of recent literature on the effect of magnetic field on the response of radiochromic films, we studied the influence of 0.35 T magnetic field on dosimetric response of EBT3 and EBT-XD GafchromicTM films. METHODS:Two different models of radiochromic films, EBT3 and EBT-XD, were ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14313

    authors: Darafsheh A,Hao Y,Maraghechi B,Cammin J,Reynoso FJ,Khan R

    更新日期:2020-09-01 00:00:00

  • Linear motion correction in three dimensions applied to dynamic gadolinium enhanced breast imaging.

    abstract::Quantitative analysis of dynamic gadolinium-DTPA (diethylenetriamine pentaacetic acid) enhanced magnetic resonance imaging (MRI) is emerging as a highly sensitive tool for detecting malignant breast tissue. Three-dimensional rapid imaging techniques, such as keyhole MRI, yield high temporal sampling rates to accuratel...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598576

    authors: Krishnan S,Chenevert TL,Helvie MA,Londy FL

    更新日期:1999-05-01 00:00:00

  • Poster - Thur Eve - 23: Statistical analysis and verification of the percentage depth dose calculation based on the tissue maximum ratio in external beam radiotherapy.

    abstract::The aim of this study is to perform a statistical analysis to verify the calculated percentage depth dose (PDD) based on the tissue maximum ratio (TMR) with the PDD measurements taken in water. 6 and 15 MV photon beams produced by a Varian linear 2100 C/D accelerator were used. PDDs and TMRs were measured at various d...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4740131

    authors: Isa M,Iqbal K,Afzal M,Buzdar S,Chow J

    更新日期:2012-07-01 00:00:00

  • SU-E-J-170: Clinical Evaluation of Positioning Accuracy of Two Immobilization Devices for Stereotactic Body Radiotherapy Using Cone Beam CT.

    abstract:PURPOSE:To evaluate the patient positioning accuracy and reproducibility of two commercially available immobilization systems for Stereotactic Body Radiotherapy (SBRT) treatment. METHODS:Forty one patients with lung (n=21) or liver (n=20) malignancies were assigned to one of the two immobilization devices: Elekta ster...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735009

    authors: Cao M,Cao N,Cardenes H,Fakiris A,Desrosiers C,Das I

    更新日期:2012-06-01 00:00:00

  • Poster - Thurs Eve-10: The accuracy of MU calculations for enhanced dynamic wedge with the Varian's anisotropic analytical algorithm.

    abstract::The Anisotropic Analytical Algorithm (AAA) of the Varian Eclipse treatment planning system calculates absolute dose for a variety of beam settings including those with an enhanced dynamic wedge (EDW). This algorithm has gone through a number of version updates since it was first released in July 2005. Previous version...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2965929

    authors: Salomons G,Kerr A,Mei X,Patel D

    更新日期:2008-07-01 00:00:00

  • Analytical considerations of beam hardening in medical accelerator photon spectra.

    abstract::Beam hardening is a well-known phenomenon for therapeutic accelerator beams passing through matter in narrow beam geometry. This study assesses quantitatively the magnitude of beam hardening of therapeutic beams in water. A formal concept of beam hardening is proposed which is based on the decrease of the mean attenua...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598704

    authors: Kleinschmidt C

    更新日期:1999-09-01 00:00:00

  • Incorporating multi-leaf collimator leaf sequencing into iterative IMRT optimization.

    abstract::Intensity modulated radiation therapy (IMRT) treatment planning typically considers beam optimization and beam delivery as separate tasks. Following optimization, a multi-leaf collimator (MLC) or other beam delivery device is used to generate fluence patterns for patient treatment delivery. Due to limitations and char...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1477230

    authors: Siebers JV,Lauterbach M,Keall PJ,Mohan R

    更新日期:2002-06-01 00:00:00

  • Evaluation of deformable registration of patient lung 4DCT with subanatomical region segmentations.

    abstract::Deformable registration is needed for a variety of tasks in establishing the voxel correspondence between respiratory phases. Most registration algorithms assume or imply that the deformation field is smooth and continuous everywhere. However, the lungs are contained within closed invaginated sacs called pleurae and a...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2828378

    authors: Wu Z,Rietzel E,Boldea V,Sarrut D,Sharp GC

    更新日期:2008-02-01 00:00:00

  • Confirmation of a realistic reactor model for BNCT dosimetry at the TRIGA Mainz.

    abstract:PURPOSE:In order to build up a reliable dose monitoring system for boron neutron capture therapy (BNCT) applications at the TRIGA reactor in Mainz, a computer model for the entire reactor was established, simulating the radiation field by means of the Monte Carlo method. The impact of different source definition techni...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4897242

    authors: Ziegner M,Schmitz T,Khan R,Blaickner M,Palmans H,Sharpe P,Hampel G,Böck H

    更新日期:2014-11-01 00:00:00

  • The properties of the ultramicrocylindrical ionization chamber for small field used in stereotactic radiosurgery.

    abstract::Accurate dosimetry of small-field photon beams tends to be difficult to perform due to the presence of lateral electronic disequilibrium and steep dose gradients. In stereotactic radiosurgery (SRS), small fields of 6-30 mm in diameter are used. Generally thermoluminescence dosimetry chips, Farmer, Thimble ion chamber,...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1350437

    authors: Vahc YW,Chung WK,Park KR,Lee JY,Lee YH,Kwon O,Kim S

    更新日期:2001-03-01 00:00:00

  • Focal spot motion of linear accelerators and its effect on portal image analysis.

    abstract::The focal spot of a linear accelerator is often considered to have a fully stable position. In practice, however, the beam control loop of a linear accelerator needs to stabilize after the beam is turned on. As a result, some motion of the focal spot might occur during the start-up phase of irradiation. When acquiring...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1576229

    authors: Sonke JJ,Brand B,van Herk M

    更新日期:2003-06-01 00:00:00

  • Poster - Thur Eve - 66: A planning comparison between RapidArc and intensity modulated radiotherapy for head and neck cancer.

    abstract::Volumetric modulated arc therapy (VMAT) has recently been used to improve the dose distribution and efficiency of treatment delivery over the standard intensity-modulated radiotherapy (IMRT) technique. This study compares the dosimetry between RapidArc plan and standard IMRT plan for head and neck cancer. Three head a...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4740174

    authors: Jiang R,Fleck A,Schaly B,Charland P,Zhan L,Alliet K,Rachakonda R,Osei E

    更新日期:2012-07-01 00:00:00

  • State-of-the-art in two-dimensional ultrasonic transducer array technology.

    abstract::Attention is given to means of sensing ultrasonic energy distributions over an area. Under the restraints appropiate to real-time imaging of deep body organs, piezoelectric arrays offer the most promising method. Adaptation of integrated circuit techniques to array assembly permits very large arrays of small elements ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594247

    authors: Maginness MG,Plummer JD,Beaver WL,Meindl JD

    更新日期:1976-09-01 00:00:00

  • Performance characteristics of A 150 plastic-equivalent gases in A 150 plastic proportional counters for 14.8-MeV neutrons.

    abstract::Two recently developed A 150 plastic-equivalent gas mixtures have been tested for suitability in proportional counter applications. Methane- and propane-based "tissue-equivalent" gases were also included for comparison purposes. Event-size weighted dose distributions were measured in a 14.8-MeV neutron beam. Resolutio...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595536

    authors: DeLuca PM Jr,Schell MC,Pearson DW,Higgins PD,Attix FH

    更新日期:1984-07-01 00:00:00

  • The effects of divergence and nonuniformity on the x-ray pencil-beam dose kernel.

    abstract::The scattered-photon part of pencil-beam dose kernels for high-energy x-ray beams can be derived experimentally by differentiating the broad-beam scatter-to-primary dose ratio as a function of radius. Formally, this requires a uniform and parallel beam, and the procedure is complicated by the nonideal, actual beam con...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597884

    authors: Ceberg CP,Bjärngard BE

    更新日期:1996-09-01 00:00:00

  • Technical Note: Impact of the geometry dependence of the ion chamber detector response function on a convolution-based method to address the volume averaging effect.

    abstract:PURPOSE:To investigate the geometry dependence of the detector response function (DRF) of three commonly used scanning ionization chambers and its impact on a convolution-based method to address the volume averaging effect (VAE). METHODS:A convolution-based approach has been proposed recently to address the ionization...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4944783

    authors: Barraclough B,Li JG,Lebron S,Fan Q,Liu C,Yan G

    更新日期:2016-05-01 00:00:00

  • Variations in energy spectra and water-to-material stopping-power ratios in three-dimensional conformal and intensity-modulated photon fields.

    abstract::Because of complex dose distributions and dose gradients that are created in three-dimensional conformal radiotherapy (3D-CRT) and intensity-modulated radiation therapy (IMRT), photon- and electron-energy spectra might change significantly with spatial locations and doses. This study examined variations in photon- and...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2710550

    authors: Jang SY,Liu HH,Mohan R,Siebers JV

    更新日期:2007-04-01 00:00:00

  • SU-E-I-77: X-Ray Coherent Scatter Diffraction Pattern Modeling in GEANT4.

    abstract:PURPOSE:To model X-ray coherent scatter diffraction patterns in GEANT4 for simulating experiments involving material detection through diffraction pattern measurement. Although coherent scatter cross-sections are modeled accurately in GEANT4, diffraction patterns for crystalline materials are not yet included. Here we ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734794

    authors: Kapadia A,Samei E,Harrawood B,Sahbaee P,Chawla A,Tan Z,Brady D

    更新日期:2012-06-01 00:00:00

  • Correcting magnetic resonance k-space data for in-plane motion using an optical position tracking system.

    abstract:PURPOSE:Motion is a major confound of image quality in MRI. A method of retrospectively correcting the effects of rotations and translations on the acquired k-space data is presented. METHODS:In two phantom experiments of well-controlled translation and rotation, two MRI-compatible infrared cameras recorded motion dat...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3254189

    authors: Marxen M,Marmurek J,Baker N,Graham SJ

    更新日期:2009-12-01 00:00:00

  • Radiologic validation of a fast neutron multileaf collimator.

    abstract::Teletherapy with high linear energy transfer radiations (LET), perhaps more than with low LET types, requires careful beam collimation to limit effects to normal structures. Intensity modulated techniques may also hold promise in this regard. Accordingly, a remote computer-controlled, high-resolution multileaf collima...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2760026

    authors: Farr JB,Maughan RL,Yudelev M,Blosser E,Brandon J,Horste T,Forman JD

    更新日期:2007-09-01 00:00:00

  • Analyzing the impact of intrafraction motion: correlation of different dose metrics with changes in target D95%.

    abstract:PURPOSE:A number of techniques are available to determine the dosimetric impact of intrafraction motion during intensity modulated radiation therapy (IMRT). Motion-induced dose perturbations can be determined both computationally and experimentally using a number of different dosimetric metrics. However, these measures...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3605633

    authors: Waghorn BJ,Meeks SL,Langen KM

    更新日期:2011-08-01 00:00:00

  • Measurement of LINAC 90 degrees head leakage radiation TVL values.

    abstract::One of the key components in modern LINAC room shielding design is the amount of 90 degrees head leakage radiation levels. With the general clinical acceptance of intensity-modulated radiation therapy (IMRT) technique, accurate knowledge of this quantity has become even more important. Measurement of 90 degrees head l...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2335489

    authors: Li Z,Mutic S,Low D

    更新日期:2006-09-01 00:00:00