Abstract:
PURPOSE:The authors have recently developed a cine-mode T2*/T1-weighted 4D-MRI technique and a sequential-mode T2-weighted 4D-MRI technique for imaging respiratory motion. This study aims at investigating which 4D-MRI image acquisition mode, cine or sequential, provides more accurate measurement of organ motion during respiration. METHODS:A 4D digital extended cardiac-torso (XCAT) human phantom with a hypothesized tumor was used to simulate the image acquisition and the 4D-MRI reconstruction. The respiratory motion was controlled by the given breathing signal profiles. The tumor was manipulated to move continuously with the surrounding tissue. The motion trajectories were measured from both sequential- and cine-mode 4D-MRI images. The measured trajectories were compared with the average trajectory calculated from the input profiles, which was used as references. The error in 4D-MRI tumor motion trajectory (E) was determined. In addition, the corresponding respiratory motion amplitudes of all the selected 2D images for 4D reconstruction were recorded. Each of the amplitude was compared with the amplitude of its associated bin on the average breathing curve. The mean differences from the average breathing curve across all slice positions (D) were calculated. A total of 500 simulated respiratory profiles with a wide range of irregularity (Ir) were used to investigate the relationship between D and Ir. Furthermore, statistical analysis of E and D using XCAT controlled by 20 cancer patients' breathing profiles was conducted. Wilcoxon Signed Rank test was conducted to compare two modes. RESULTS:D increased faster for cine-mode (D = 1.17 × Ir + 0.23) than sequential-mode (D = 0.47 × Ir + 0.23) as irregularity increased. For the XCAT study using 20 cancer patients' breathing profiles, the median E values were significantly different: 0.12 and 0.10 cm for cine- and sequential-modes, respectively, with a p-value of 0.02. The median D values were significantly different: 0.47 and 0.24 cm for cine- and sequential-modes, respectively, with a p-value < 0.001. CONCLUSIONS:Respiratory motion measurement may be more accurate and less susceptible to breathing irregularity in sequential-mode 4D-MRI than that in cine-mode 4D-MRI.
journal_name
Med Physjournal_title
Medical physicsauthors
Liu Y,Yin FF,Rhee D,Cai Jdoi
10.1118/1.4938066subject
Has Abstractpub_date
2016-01-01 00:00:00pages
179issue
1eissn
0094-2405issn
2473-4209journal_volume
43pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract:PURPOSE:Elastography using computer tomography (CT) is a promising methodology that can provide patient-specific regional distributions of lung biomechanical properties. The purpose of this paper is to investigate the feasibility of performing elastography using simulated lower dose CT scans. METHODS:A cohort of eight...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14112
更新日期:2020-08-01 00:00:00
abstract::Proton therapy offers the potential for excellent dose conformity and reduction in integral dose. The superior dose distribution is, however, much more sensitive to changes in radiological depths along the beam path than for photon fields. Respiratory motion can cause such changes for treatments sites like lung, liver...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2756602
更新日期:2007-08-01 00:00:00
abstract:PURPOSE:A compact, three-tesla magnetic resonance imaging (MRI) system has been developed. It features a 37 cm patient aperture, allowing the use of commercial receiver coils. Its design allows simultaneously for gradient amplitudes of 85 millitesla per meter (mT/m) sustained and 700 tesla per meter per second (T/m/s) ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4941362
更新日期:2016-03-01 00:00:00
abstract::The BrachySeed model LS-1 is one of the latest in a series of new brachytherapy 125I seeds that have recently become available commercially for interstitial implants. The dosimetric properties of the seed were investigated analytically, experimentally, and by Monte Carlo simulation. Following the AAPM Task Group 43 fo...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1445411
更新日期:2002-02-01 00:00:00
abstract:PURPOSE:To provide an overview of the types of adverse events reported to the US Food and Drug Administration (US FDA) for magnetic resonance (MR) systems over a 10-yr period. METHODS:Two reviewers independently reviewed adverse events reported to FDA for MR systems from 1 January 2008 to 31 December 2017 and manually...
journal_title:Medical physics
pub_type: 杂志文章,评审
doi:10.1002/mp.13768
更新日期:2019-12-01 00:00:00
abstract::Studies suggest that clinical outcomes are improved in repeat trigeminal neuralgia (TN) Gamma Knife radiosurgery if a different part of the nerve from the previous radiosurgery is treated. The MR images taken in the first and repeat radiosurgery need to be coregistered to map the first radiosurgery volume onto the sec...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1944287
更新日期:2005-07-01 00:00:00
abstract:PURPOSE:Theoretical reasoning suggests that direct conversion digital x-ray detectors based upon photoconductive amorphous-selenium (a-Se) could attain very high values of the MTF (modulation transfer function) at spatial frequencies well beyond 20 cycles mm(-1). One of the fundamental factors affecting resolution loss...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3673957
更新日期:2012-02-01 00:00:00
abstract:PURPOSE:The aim of this study was to implement a Dirichlet process mixture (DPM) model for automatic tumor edge identification on (18)F-fluorodeoxyglucose positron emission tomography ((18)F-FDG PET) images by optimizing the parameters on which the algorithm depends, to validate it experimentally, and to test its robus...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4947123
更新日期:2016-05-01 00:00:00
abstract:PURPOSE:In breast radiotherapy with intensity modulation, it is a well established practice to extend the dose fluence outside the limit of the body contour to account for small changes in size and position of the target and the rest of the tissues due to respiration or to possible oedema. A simple approach is not appl...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3598442
更新日期:2011-07-01 00:00:00
abstract:PURPOSE:In order to build up a reliable dose monitoring system for boron neutron capture therapy (BNCT) applications at the TRIGA reactor in Mainz, a computer model for the entire reactor was established, simulating the radiation field by means of the Monte Carlo method. The impact of different source definition techni...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4897242
更新日期:2014-11-01 00:00:00
abstract::Cone-beam computed tomography systems have been developed to provide in situ imaging for the purpose of guiding radiation therapy. Clinical systems have been constructed using this approach, a clinical linear accelerator (Elekta Synergy RP) and an iso-centric C-arm. Geometric calibration involves the estimation of a s...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1869652
更新日期:2005-04-01 00:00:00
abstract:PURPOSE:To design a fast Winston Lutz (fWL) algorithm for accurate analysis of radiation isocenter from images without edge detection or center of mass calculations. METHODS:An algorithm has been developed to implement the Winston Lutz test for mechanical/ radiation isocenter agreement using an electronic portal imagi...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3524227
更新日期:2011-01-01 00:00:00
abstract:PURPOSE:Respiration-induced intrafraction target motion is a concern in liver cancer radiotherapy, especially in stereotactic body radiotherapy (SBRT), and therefore, verification of its motion is necessary. An effective means to localize the liver cancer is to insert metal fiducial markers to or near the tumor with si...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3544369
更新日期:2011-02-01 00:00:00
abstract::Recent work has shown that there is significant uncertainty in measuring build-up doses in mega-voltage photon beams especially at high energies. In this present investigation we used a phantom-embedded extrapolation chamber (PEEC) made of Solid Water to validate Monte Carlo (MC)-calculated doses in the dose build-up ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1829401
更新日期:2005-01-01 00:00:00
abstract:PURPOSE:In the practice code of dosimetry, humidity effect is assumed to be constant as far as the measurements are performed in the relative humidity (RH) range of (20-80)%; thus, the humidity effect can be ignored with a dose uncertainty of 0.15%. This assumption is based on the previous experimental results by Niate...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13665
更新日期:2019-09-01 00:00:00
abstract::In a series of in vivo experiments on five adult canines, a small cylindrical permanent magnet (approximately 5-mm diameter x 5 mm long) was magnetically moved under fluoroscopic guidance from an occipital-lobe burr hole to a predetermined destination within the brain and then removed. On three of the animals, dorsal ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596520
更新日期:1990-05-01 00:00:00
abstract::Simultaneous rest 99mTc-Sestamibi/ 123I-BMIPP cardiac SPECT imaging has the potential to replace current clinical 99mTc-Sestamibi rest/stress imaging and therefore has great potential in the case of patients with chest pain presenting to the emergency department. Separation of images of these two radionuclides is diff...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3063544
更新日期:2009-02-01 00:00:00
abstract::It is shown that in narrow monoenergetic photon beams under conditions of lateral electron disequilibrium, primary absorbed dose P(r) is a simple function of beam radius r: P(r) = P lambda.(1 - e(-gamma.r)), where P lambda is the primary dose in broad beams for which complete lateral electron equilibrium exists, and g...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596741
更新日期:1991-07-01 00:00:00
abstract::A contrast-detail (CD) experiment was performed to study the effect of lossy compression on computed radiographic (CR) images. Digital CR images of a phantom were compressed by quantizing the full-frame discrete cosine transform and Huffman encoding the result. Since low-contrast detectability is directly linked to an...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597489
更新日期:1995-06-01 00:00:00
abstract::Three Monte Carlo photon/electron transport codes (GEPTS, EGSnrc, and MCNP) are bench-marked against dose measurements in homogeneous (both low- and high-Z) media as well as at interfaces. A brief overview on physical models used by each code for photon and electron (positron) transport is given. Absolute calorimetric...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1473134
更新日期:2002-05-01 00:00:00
abstract:PURPOSE:Current treatment planning for 90 Y radioembolization estimates lung mean dose (LMD) by measuring the lung shunt fraction (LSF) from 99m Tc-macroaggregated albumin (MAA) planar imaging and assuming a 1-kg lung mass. This methodology, however, overestimates LSF and LMD and could therefore unnecessarily limit the...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13575
更新日期:2019-09-01 00:00:00
abstract:PURPOSE:Positron emission tomography (PET) is considered the gold standard for measuring myocardial blood flow in vivo but it is known that respiratory motion can lead to misalignment of the PET and computed tomography (CT) data sets and introduce artifacts in the CT-based attenuation correction (AC) of images. In addi...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4788669
更新日期:2013-02-01 00:00:00
abstract:PURPOSE:A critical step in adaptive radiotherapy (ART) workflow is deformably registering the simulation CT with the daily or weekly volumetric imaging. Quantifying the deformable image registration accuracy under these circumstances is a complex task due to the lack of known ground-truth landmark correspondences betwe...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12321
更新日期:2017-08-01 00:00:00
abstract::Estimates of the effective dose to adult patients from computed tomography (CT) head scanning can be calculated using a number of different methods. These estimates can be used for a variety of purposes, such as improving scanning protocols, comparing different CT imaging centers, and weighing the benefits of the scan...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2952359
更新日期:2008-08-01 00:00:00
abstract:PURPOSE:To describe an efficient method for verifying the size and centering of the radiation field from the Cyberknife IRIS variable collimator with sub-millimeter accuracy using a general purpose commercially available diode array. METHODS:We present a technique using a conventional diode array (Sun Nuclear Profiler...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735220
更新日期:2012-06-01 00:00:00
abstract::A photon transport algorithm for fully three-dimensional radiotherapy treatment planning has been developed based on the discrete ordinates (SN) solution of the Boltzmann equation. The algorithm is characterized by orthogonal adaptive meshes, which place additional points where large gradients occur and a procedure to...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2960247
更新日期:2008-09-01 00:00:00
abstract::The Monte Carlo (MC) method has been shown through many research studies to calculate accurate dose distributions for clinical radiotherapy, particularly in heterogeneous patient tissues where the effects of electron transport cannot be accurately handled with conventional, deterministic dose algorithms. Despite its p...
journal_title:Medical physics
pub_type: 杂志文章,评审
doi:10.1118/1.2795842
更新日期:2007-12-01 00:00:00
abstract:PURPOSE:To study the relationships between dose (D), kerma (K), and collision kerma ( K col ) in photon beams and to investigate total radiative yields for electrons and positrons as a functio...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13744
更新日期:2019-11-01 00:00:00
abstract:PURPOSE:To present EBT2 film verification of treatment planning with the eXtend System, a relocatable frame system for multiple-fraction or serial multiple-session radiosurgery. METHODS:A human head shaped phantom simulated the verification process for fractionated Gamma Knife (GK) treatment. Phantom preparation for e...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735487
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:The main objective of this work was to design a comprehensive dosimetry package that would keep all aspects of internal dose calculation within the framework of a single software environment and that would be applicable for a variety of dose calculation approaches. METHODS:Our MATLAB-based graphical user inter...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4810963
更新日期:2013-07-01 00:00:00