A fast double template convolution isocenter evaluation algorithm with subpixel accuracy.

Abstract:

PURPOSE:To design a fast Winston Lutz (fWL) algorithm for accurate analysis of radiation isocenter from images without edge detection or center of mass calculations. METHODS:An algorithm has been developed to implement the Winston Lutz test for mechanical/ radiation isocenter agreement using an electronic portal imaging device (EPID). The algorithm detects the position of the radiation shadow of a tungsten ball within a stereotactic cone. The fWL algorithm employs a double convolution to independently find the position of the sphere and cone centers. Subpixel estimation is used to achieve high accuracy. Results of the algorithm were compared to (1) a human observer with template guidance and (2) an edge detection/center of mass (edCOM) algorithm. Testing was performed with high resolution (0.05 mm/px, film) and low resolution (0.78 mm/px, EPID) image sets. RESULTS:Sphere and cone center relative positions were calculated with the fWL algorithm for high resolution test images with an accuracy of 0.002 +/- 0.061 mm compared to 0.042 +/- 0.294 mm for the human observer, and 0.003 +/- 0.038 mm for the edCOM algorithm. The fWL algorithm required 0.01 s per image compared to 5 s for the edCOM algorithm and 20 s for the human observer. For lower resolution images the fWL algorithm localized the centers with an accuracy of 0.083 +/- 0.12 mm compared to 0.03 +/- 0.5514 mm for the edCOM algorithm. CONCLUSIONS:A fast (subsecond) subpixel algorithm has been developed that can accurately determine the center locations of the ball and cone in Winston Lutz test images without edge detection or COM calculations.

journal_name

Med Phys

journal_title

Medical physics

authors

Winey B,Sharp G,Bussière M

doi

10.1118/1.3524227

subject

Has Abstract

pub_date

2011-01-01 00:00:00

pages

223-7

issue

1

eissn

0094-2405

issn

2473-4209

journal_volume

38

pub_type

杂志文章
  • Mitigating differential baseline shifts in locally advanced lung cancer patients using an average anatomy model.

    abstract:BACKGROUND AND PURPOSE:Differential baseline shifts between primary tumor and involved lymph nodes in locally advanced lung cancer patients compromise the accuracy of radiotherapy. The purpose of this study was to evaluate the performance of an average anatomy model (AAM) derived from repeat imaging and deformable regi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12271

    authors: Abdoli M,Van Kranen SR,Stankovic U,Rossi MMG,Belderbos JSA,Sonke JJ

    更新日期:2017-07-01 00:00:00

  • Tolerance limits and methodologies for IMRT measurement-based verification QA: Recommendations of AAPM Task Group No. 218.

    abstract:PURPOSE:Patient-specific IMRT QA measurements are important components of processes designed to identify discrepancies between calculated and delivered radiation doses. Discrepancy tolerance limits are neither well defined nor consistently applied across centers. The AAPM TG-218 report provides a comprehensive review a...

    journal_title:Medical physics

    pub_type: 杂志文章,评审

    doi:10.1002/mp.12810

    authors: Miften M,Olch A,Mihailidis D,Moran J,Pawlicki T,Molineu A,Li H,Wijesooriya K,Shi J,Xia P,Papanikolaou N,Low DA

    更新日期:2018-04-01 00:00:00

  • Technical Note: Transconvolution based equalization of positron energy effects for the use of 68 Ge/68 Ga phantoms in determining 18 F PET recovery.

    abstract:PURPOSE:Avoiding measurement variability from 18 F phantom preparation by using 68 Ge/68 Ga phantoms for the determination of 18 F recovery curves (RC) in clinical quality assurance measurements and for PET/CT site qualification in multicentre clinical trials. METHODS:RCs were obtained from PET/CT measurements of seve...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12330

    authors: Prenosil GA,Hentschel M,Fürstner M,Krause T,Weitzel T,Klaeser B

    更新日期:2017-07-01 00:00:00

  • Development and validation of a measurement-based source model for kilovoltage cone-beam CT Monte Carlo dosimetry simulations.

    abstract:PURPOSE:The purpose of this study is to adapt an equivalent source model originally developed for conventional CT Monte Carlo dose quantification to the radiation oncology context and validate its application for evaluating concomitant dose incurred by a kilovoltage (kV) cone-beam CT (CBCT) system integrated into a lin...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4823795

    authors: McMillan K,McNitt-Gray M,Ruan D

    更新日期:2013-11-01 00:00:00

  • The x-ray light valve: a potentially low-cost, digital radiographic imaging system-concept and implementation considerations.

    abstract::New x-ray radiographic systems based on large-area flat-panel technology have revolutionized our capability to produce digital x-ray images. However, these imagers are extraordinarily expensive compared to the systems they are replacing. Hence, there is a need for a low-cost digital imaging system for general applicat...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2837288

    authors: Webster CA,Koprinarov I,Germann S,Rowlands JA

    更新日期:2008-03-01 00:00:00

  • SU-D-BRCD-02: A Novel Cylindrical 3D Water Scanner for Beam Data Collection: I. Validation of the Automatic-Setup.

    abstract:PURPOSE:To determine the accuracy and reproducibility of the automatic- setup procedure of a 3D water scanner (3D SCANNER, Sun Nuclear Corp). The procedure automatically aligns the scanner's coordinate system to the Linac coordinate system. A unique off-center detector holder extends the scan range to 630 mm, eliminati...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734668

    authors: Li J,Lu B,Yan G,Huang Y,Liu C

    更新日期:2012-06-01 00:00:00

  • Computerized detection of masses in digital mammograms: automated alignment of breast images and its effect on bilateral-subtraction technique.

    abstract::An automated technique for the alignment of right and left breast images has been developed for use in the computerized analysis of bilateral breast images. In this technique, the breast region is first identified in each digital mammogram by use of histogram analysis and morphological filtering operations. The anteri...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597307

    authors: Yin FF,Giger ML,Doi K,Vyborny CJ,Schmidt RA

    更新日期:1994-03-01 00:00:00

  • Model-based geometric calibration for medical x-ray systems.

    abstract:PURPOSE:Currently applied calibration approaches lead to satisfying 3D roadmapping overlay and 3D reconstruction accuracies; however, the required calibration times are extensive. The aim of this paper is the introduction of a novel model-based approach for geometric system calibrations, leading to a significant reduct...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4931964

    authors: van der Maas R,de Jager B,Steinbuch M,Dries J

    更新日期:2015-11-01 00:00:00

  • SU-E-T-476: GPU-Based Monte Carlo Radiotherapy Dose Calculation Using Phase- Space Sources.

    abstract:PURPOSE:To design an efficient method for utilizing phase-space source models in the GPU-based Monte Carlo (MC) dose calculation engine gDPM. METHODS:In GPU-based MC algorithms, particles are transported in parallel on different threads. Particles of different types and energies can require significantly different exe...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735565

    authors: Townson R,Jia X,Zavgorodni S,Jiang S

    更新日期:2012-06-01 00:00:00

  • Measurement of transit time of a remote after-loading high dose rate brachytherapy source.

    abstract::Quantification of transit time of a remote after-loading high dose rate (HDR) brachytherapy source is important both for accurate treatment planning and for quality assurance checks. In this investigation, an HDR-1000 well ionization chamber and a precision electrometer are used to measure the transit time of the Ir-1...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1386779

    authors: Sahoo N

    更新日期:2001-08-01 00:00:00

  • Sci-Sat AM(1): Imaging-04: Respiratory errors in cardiac PET/CT with manual alignment of the CT image.

    abstract::Respiratory motion can produce misregistration errors between CT and PET images in cardiac PET/CT imaging. The objective of this study was to determine if manual registration of a single-phase end-expiration CT scan to the PET image would eliminate respiratory-induced artifacts. Listmode data from 71 cardiac PET patie...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2965988

    authors: Wells RG

    更新日期:2008-07-01 00:00:00

  • Proliferative diabetic retinopathy characterization based on fractal features: Evaluation on a publicly available dataset.

    abstract:PURPOSE:Diabetic retinopathy (DR) is one of the most widespread causes of preventable blindness in the world. The most dangerous stage of this condition is proliferative DR (PDR), in which the risk of vision loss is high and treatments are less effective. Fractal features of the retinal vasculature have been previously...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12627

    authors: Orlando JI,van Keer K,Barbosa Breda J,Manterola HL,Blaschko MB,Clausse A

    更新日期:2017-12-01 00:00:00

  • Improvement of registration accuracy in accelerated partial breast irradiation using the point-based rigid-body registration algorithm for patients with implanted fiducial markers.

    abstract:PURPOSE:To investigate image-registration errors when using fiducial markers with a manual method and the point-based rigid-body registration (PRBR) algorithm in accelerated partial breast irradiation (APBI) patients, with accompanying fiducial deviations. METHODS:Twenty-two consecutive patients were enrolled in a pro...

    journal_title:Medical physics

    pub_type: 临床试验,杂志文章

    doi:10.1118/1.4915534

    authors: Inoue M,Yoshimura M,Sato S,Nakamura M,Yamada M,Hirata K,Sasaki M,Fujimoto T,Ogura M,Hiraoka M

    更新日期:2015-04-01 00:00:00

  • Absolute dosimetry of a 1.5 T MR-guided accelerator-based high-energy photon beam in water and solid phantoms using Aerrow.

    abstract:PURPOSE:In this work, the fabrication, operation, and evaluation of a probe-format graphite calorimeter - herein referred to as Aerrow - as an absolute clinical dosimeter of high-energy photon beams while in the presence of a B = 1.5 T magnetic field is described. Comparable to a cylindrical ionization chamber (IC) in ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13968

    authors: Renaud J,Sarfehnia A,Bancheri J,Seuntjens J

    更新日期:2020-03-01 00:00:00

  • Characterization of difference of Gaussian filters in the detection of mammographic regions.

    abstract::In this article, we present a characterization of the effect of difference of Gaussians (DoG) filters in the detection of mammographic regions. DoG filters have been used previously in mammographic mass computer-aided detection (CAD) systems. As DoG filters are constructed from the subtraction of two bivariate Gaussia...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2358326

    authors: Catarious DM Jr,Baydush AH,Floyd CE Jr

    更新日期:2006-11-01 00:00:00

  • Determination of exit skin dose for 192Ir intracavitary accelerated partial breast irradiation with thermoluminescent dosimeters.

    abstract:PURPOSE:Intracavitary accelerated partial breast irradiation (APBI) has become a popular treatment for early stage breast cancer in recent years due to its shortened course of treatment and simplified treatment planning compared to traditional external beam breast conservation therapy. However, the exit dose to the ski...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3429089

    authors: Raffi JA,Davis SD,Hammer CG,Micka JA,Kunugi KA,Musgrove JE,Winston JW Jr,Ricci-Ott TJ,DeWerd LA

    更新日期:2010-06-01 00:00:00

  • Benchmarking analytical calculations of proton doses in heterogeneous matter.

    abstract::A proton dose computational algorithm, performing an analytical superposition of infinitely narrow proton beamlets (ASPB) is introduced. The algorithm uses the standard pencil beam technique of laterally distributing the central axis broad beam doses according to the Moliere scattering theory extended to slablike vary...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2064887

    authors: Ciangaru G,Polf JC,Bues M,Smith AR

    更新日期:2005-12-01 00:00:00

  • B-spline active rays segmentation of microcalcifications in mammography.

    abstract::Accurate segmentation of microcalcifications in mammography is crucial for the quantification of morphologic properties by features incorporated in computer-aided diagnosis schemes. A novel segmentation method is proposed implementing active rays (polar-transformed active contours) on B-spline wavelet representation t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2991286

    authors: Arikidis NS,Skiadopoulos S,Karahaliou A,Likaki E,Panayiotakis G,Costaridou L

    更新日期:2008-11-01 00:00:00

  • Characterization of mesothelioma and tissues present in contrast-enhanced thoracic CT scans.

    abstract:PURPOSE:The purpose of this study was to characterize the Hounsfield unit (HU) distributions of mesothelioma and other tissues present in contrast-enhanced thoracic CT scans, to compare the HU distributions of mesothelioma, muscle, and liver by scanner and reconstruction filter/kernel combination, and to assess interpa...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3537610

    authors: Corson N,Sensakovic WF,Straus C,Starkey A,Armato SG 3rd

    更新日期:2011-02-01 00:00:00

  • Anatomical pulmonary magnetic resonance imaging segmentation for regional structure-function measurements of asthma.

    abstract:PURPOSE:Pulmonary magnetic-resonance-imaging (MRI) and x-ray computed-tomography have provided strong evidence of spatially and temporally persistent lung structure-function abnormalities in asthmatics. This has generated a shift in their understanding of lung disease and supports the use of imaging biomarkers as inter...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4948999

    authors: Guo F,Svenningsen S,Eddy RL,Capaldi DPI,Sheikh K,Fenster A,Parraga G

    更新日期:2016-06-01 00:00:00

  • SU-E-T-109: An Evaluation of a Newly Available Portal Dosimetry QA Tool for SRS Dynamic Arc and VMAT.

    abstract:PURPOSE:In our institute, the MatriXX has been used for IMRT, VMAT and dynamic arc QA. However, the small fields (<3cm) shaped by HDMLC for SRS dynamic arc (DA) present QA measurement issues when using the MatriXX due to its limited resolution (7.6 mm). A recently available portal dosimetry (PD) software tool in Eclips...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735167

    authors: Luo G,Crass J,Morales M,Ding G

    更新日期:2012-06-01 00:00:00

  • On the new metrics for IMRT QA verification.

    abstract:PURPOSE:The aim of this work is to search for new metrics that could give more reliable acceptance/rejection criteria on the IMRT verification process and to offer solutions to the discrepancies found among different conventional metrics. Therefore, besides conventional metrics, new ones are proposed and evaluated with...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4964796

    authors: Garcia-Romero A,Hernandez-Vitoria A,Millan-Cebrian E,Alba-Escorihuela V,Serrano-Zabaleta S,Ortega-Pardina P

    更新日期:2016-11-01 00:00:00

  • Analytical probabilistic modeling of dose-volume histograms.

    abstract:PURPOSE:Radiotherapy, especially with charged particles, is sensitive to executional and preparational uncertainties that propagate to uncertainty in dose and plan quality indicators, for example, dose-volume histograms (DVHs). Current approaches to quantify and mitigate such uncertainties rely on explicitly computed e...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14414

    authors: Wahl N,Hennig P,Wieser HP,Bangert M

    更新日期:2020-10-01 00:00:00

  • Computed tomography scanning with simultaneous patient translation.

    abstract::This paper deals with methods of reducing the total time required to acquire the projection data for a set of contiguous computed tomography (CT) images. Normally during the acquisition of a set of slices, the patient is held stationary during data collection and translated to the next axial location during an intersc...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596464

    authors: Crawford CR,King KF

    更新日期:1990-11-01 00:00:00

  • Measured and calculated K-fluorescence effects on the MTF of an amorphous-selenium based CCD x-ray detector.

    abstract:PURPOSE:Theoretical reasoning suggests that direct conversion digital x-ray detectors based upon photoconductive amorphous-selenium (a-Se) could attain very high values of the MTF (modulation transfer function) at spatial frequencies well beyond 20 cycles mm(-1). One of the fundamental factors affecting resolution loss...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3673957

    authors: Hunter DM,Belev G,Kasap S,Yaffe MJ

    更新日期:2012-02-01 00:00:00

  • Cone-beam CT-derived relative stopping power map generation via deep learning for proton radiotherapy.

    abstract:PURPOSE:In intensity-modulated proton therapy (IMPT), protons are used to deliver highly conformal dose distributions, targeting tumors, and sparing organs-at-risk. However, due to uncertainties in both patient setup and relative stopping power (RSP) calculation, margins are added to the treatment volume during treatme...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14347

    authors: Harms J,Lei Y,Wang T,McDonald M,Ghavidel B,Stokes W,Curran WJ,Zhou J,Liu T,Yang X

    更新日期:2020-09-01 00:00:00

  • Prior data assisted compressed sensing: a novel MR imaging strategy for real time tracking of lung tumors.

    abstract:PURPOSE:Hybrid radiotherapy-MRI devices promise real time tracking of moving tumors to focus the radiation portals to the tumor during irradiation. This approach will benefit from the increased temporal resolution of MRI's data acquisition and reconstruction. In this work, the authors propose a novel spatial-temporal c...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4885960

    authors: Yip E,Yun J,Wachowicz K,Heikal AA,Gabos Z,Rathee S,Fallone BG

    更新日期:2014-08-01 00:00:00

  • A CdZnTe slot-scanned detector for digital mammography.

    abstract::A new high-resolution detector has been developed for use in a slot-scanned digital mammography system. The detector is a hybrid device that consists of a CCD operating in time-delay integration mode that is bonded to a 150-microm-thick CdZnTe photoconductor array. The CCD was designed with a detector element pitch of...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1523932

    authors: Mainprize JG,Ford NL,Yin S,Gordon EE,Hamilton WJ,Tümer TO,Yaffe MJ

    更新日期:2002-12-01 00:00:00

  • The alanine detector in BNCT dosimetry: dose response in thermal and epithermal neutron fields.

    abstract:PURPOSE:The response of alanine solid state dosimeters to ionizing radiation strongly depends on particle type and energy. Due to nuclear interactions, neutron fields usually also consist of secondary particles such as photons and protons of diverse energies. Various experiments have been carried out in three different...

    journal_title:Medical physics

    pub_type: 杂志文章,多中心研究

    doi:10.1118/1.4901299

    authors: Schmitz T,Bassler N,Blaickner M,Ziegner M,Hsiao MC,Liu YH,Koivunoro H,Auterinen I,Serén T,Kotiluoto P,Palmans H,Sharpe P,Langguth P,Hampel G

    更新日期:2015-01-01 00:00:00

  • A novel computer-aided lung nodule detection system for CT images.

    abstract:PURPOSE:The paper presents a complete computer-aided detection (CAD) system for the detection of lung nodules in computed tomography images. A new mixed feature selection and classification methodology is applied for the first time on a difficult medical image analysis problem. METHODS:The CAD system was trained and t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3633941

    authors: Tan M,Deklerck R,Jansen B,Bister M,Cornelis J

    更新日期:2011-10-01 00:00:00