Abstract:
PURPOSE:To design an efficient method for utilizing phase-space source models in the GPU-based Monte Carlo (MC) dose calculation engine gDPM. METHODS:In GPU-based MC algorithms, particles are transported in parallel on different threads. Particles of different types and energies can require significantly different execution times. This can cause "thread divergence" and lower efficiency when source particles are read sequentially from a phase-space file. We have developed a strategy for utilizing phase- space files in a GPU compatible manner whereby the particles are grouped into phase-space-lets (PSLs) by type, energy, and location in the phase- space plane. This allows for dose calculations using only particles inside the field opening defined by the secondary collimators. For validation, the gDPM PSL implementation is compared with DOSXYZnrc using a BEAMnrc phase-space source model as input. RESULTS:Two phase-spaces were generated using a BEAMnrc head model of a 6MV Varian Clinac 21EX, one above the upper jaws used to generate PSLs for gDPM and the other below the lower jaws used for DOSXYZnrc dose calculation. Profiles and depth dose curves for a variety of field sizes were generated in a water phantom. The agreement between gDPM and DOSXYZnrc is within 2% for all field sizes. For the 10 cm × 10 cm field, the calculation times of 650 million histories were 147 CPU hours and 54 GPU seconds for DOSXYZnrc and gDPM, respectively. In addition, we have tested the gDPM PSL implementation for dose calculation in a realistic 7-field IMRT tongue treatment plan. The calculation times were 59 CPU-hours and 66 GPU- seconds for DOSXYZnrc and gDPM for 485 million histories, respectively. Gamma pass rate for the two dose distributions was 99.54% for 3 mm/3% criteria within the 10% isodose. CONCLUSIONS:Methods for the efficient use of phase-space sources for GPU-based MC dose calculations have been developed.
journal_name
Med Physjournal_title
Medical physicsauthors
Townson R,Jia X,Zavgorodni S,Jiang Sdoi
10.1118/1.4735565subject
Has Abstractpub_date
2012-06-01 00:00:00pages
3814issue
6Part17eissn
0094-2405issn
2473-4209journal_volume
39pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract::Monte Carlo dose calculations will potentially reduce systematic errors that may be present in currently used dose calculation algorithms. However, Monte Carlo calculations inherently contain random errors, or statistical uncertainty, the level of which decreases inversely with the square root of computation time. Our...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598916
更新日期:2000-03-01 00:00:00
abstract:PURPOSE:Partial scan reconstruction (PSR) artifacts are present in myocardial perfusion imaging using dynamic multidetector computed tomography (MDCT). PSR artifacts appear as temporal CT number variations due to inconsistencies in the angular data range used to reconstruct images and compromise the quantitative value ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3665767
更新日期:2012-01-01 00:00:00
abstract::Limiting spatial resolution is a key metric of the quality of magnetic resonance (MR) images, which can provide an indication of the smallest region that can effectively be imaged. In this paper a novel methodology for measuring the limiting spatial resolution of MR images is mathematically analyzed and successfully i...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3097633
更新日期:2009-05-01 00:00:00
abstract::Quantitative evaluation of cardiac image data obtained using multidetector row computed tomography (CT) is compromised by partial scan reconstructions, which improve the temporal resolution but significantly increase image-to-image CT number variations for a fixed region of interest compared to full reconstruction ima...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2805476
更新日期:2007-12-01 00:00:00
abstract::Transthoracic electrical impedance Z consists of a constant baseline component Z0 and the time variable component delta Z such that Z = Z0 + delta Z. The first time derivative of Z has a negative peak, the magnitude of which is (dZ/dt)min. Measurements of 170 volunteers show that (dZ/dt)min is a function of the consta...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594910
更新日期:1981-01-01 00:00:00
abstract::Optical-resolution photoacoustic microscopy (OR-PAM) has been validated as a valuable tool for label-free volumetric microvascular imaging. More importantly, the advantages of noninvasiveness and measurement consistency suggest the use of OR-PAM for chronic imaging of intact microcirculation. Here, such chronic imagin...
journal_title:Medical physics
pub_type: 信件
doi:10.1118/1.3137572
更新日期:2009-06-01 00:00:00
abstract:PURPOSE:To evaluate a model which can predict patient's Entrance Skin Exposure (ESE) from height and weight and a single kVp mR/mAs measurement for radiographic. METHODS:Patient height, weight and post exposure mAs are obtained to assess ESE based on IAEA model. Patient's thickness is obtained by assuming a cylindrica...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4734825
更新日期:2012-06-01 00:00:00
abstract::Both the design considerations and the dosimetric properties of the Siemens Model 5800 linear accelerator are discussed. This unit is of such an energy (3.3 MV) as to imitate Cobalt-60 teletherapy depth doses. A linear relation of dmax to depth dose at low energies was found for various wave guides and targets. The en...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596487
更新日期:1990-05-01 00:00:00
abstract::A 4-W, laser-based system for the positional readout of thermoluminescent (TL) plates was utilized to obtain dose profiles for a 60Co radiotherapy beam. Experimentally obtained glow curves for LiF resulting from the rapid heating rates characteristic of laser heating agreed well with results predicted using a first-or...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596580
更新日期:1990-05-01 00:00:00
abstract::Intraoperative three-dimensional reconstruction of seed locations during prostate brachytherapy for purposes of immediate computation of radiation dosimetry is an active area of current investigation, including methods which use multiple fluoroscopic projections. A simulation study using seed locations extracted from ...
journal_title:Medical physics
pub_type: 临床试验,杂志文章
doi:10.1118/1.1707740
更新日期:2004-05-01 00:00:00
abstract::In this study, BrachyDose, a recently developed EGSnrc Monte Carlo code for rapid brachytherapy dose calculations, has been benchmarked by reproducing previously published dosimetry parameters for three brachytherapy seeds with varied internal structure and encapsulation. Calculations are performed for two 125I seeds ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2400843
更新日期:2007-02-01 00:00:00
abstract::We have developed two prototypes of portable gamma cameras for medical applications based on a previous prototype designed and tested by our group. These cameras use a CsI(Na) continuous scintillation crystal coupled to the new flat-panel-type multianode position-sensitive photomultiplier tube, H8500 from Hamamatsu Ph...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2358199
更新日期:2006-11-01 00:00:00
abstract::In this work, the authors have evaluated ten different ionization chambers for the relative dosimetry of kilovoltage x-ray beams in the energy range of 50-280 kVp. Percentage depth doses in water and relative detector response (in Solid Water and in air) were measured for each of the x-ray beams studied using a number...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3183820
更新日期:2009-09-01 00:00:00
abstract:PURPOSE:To apply the dual ionization chamber method for mixed radiation fields to an accurate comparison of the secondary neutron dose arising from the use of a tungsten alloy multileaf collimator (MLC) as opposed to a brass collimator system for defining the shape of a therapeutic proton field. METHODS:Hydrogenous an...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3656025
更新日期:2011-11-01 00:00:00
abstract::Image correlation is often required to utilize the complementary information in CT, MRI, and SPECT. A practical method for automatic image correlation in three-dimensions (3D) based on chamfer matching is described. The method starts with automatic extraction of contour points in one modality and automatic segmentatio...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597344
更新日期:1994-07-01 00:00:00
abstract:PURPOSE:To evaluate dependence of measured dose on size and location of region of interest (ROI) in Gafchromic EBT3 film dosimetry. METHODS:Gafchromic EBT3 films were irradiated perpendicularly using the 6MV beam from a linear accelerator at 10 cm depth (100 cm SSD) of a 30 × 30 × 20 cm3 solid water phantom for a rang...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12885
更新日期:2018-05-01 00:00:00
abstract:PURPOSE:The collimator monitoring fill factor (CM-FF) introduced by Stelljes et al. (2017) and the FWHM fill factor (FWHM-FF) introduced by Gago-Arias et al. (2012) were determined using the measured photon fluence response functions of various 2D-arrays. The error detection capabilities of 2D-arrays were studied by co...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13417
更新日期:2019-04-01 00:00:00
abstract:PURPOSE:Concurrent irradiation of the prostate and pelvic lymph nodes is technically challenging due to treating one moving target and one immobile target. The purposes of this article are to propose a new management strategy and to compare this strategy to the conventional isocenter shift method and the previously pro...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3480505
更新日期:2010-09-01 00:00:00
abstract:PURPOSE:The automated segmentation of each lung and trachea in CT scans is commonly taken as a solved problem. Indeed, existing approaches may easily fail in the presence of some abnormalities caused by a disease, trauma, or previous surgery. For robustness, we present ALTIS (implementation is available at http://lids....
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13773
更新日期:2019-11-01 00:00:00
abstract:PURPOSE:Over the last ten years, there has been an extensive growth in the development of microSPECT imagers. Most of the systems are based on the combination of conventional, relatively large gamma cameras with poor intrinsic spatial resolution and multipinhole collimators working in large magnification mode. Spatial ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4822621
更新日期:2013-11-01 00:00:00
abstract::Cone beam transmission CT (CB-CT) improves SPECT imaging by providing high-quality attenuation maps for attenuation compensation and for correlated SPECT and CT imaging. The present work measures the detection nonuniformity for CB-CT implemented with a gamma camera, and applies nonuniformity corrections to make CB-CT ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596838
更新日期:1992-03-01 00:00:00
abstract::The gamma-ray dose component of a d(80) + Be neutron beam was measured with a 6Li-shielded Geiger-Mueller counter in a tissue-equivalent liquid phantom. The proportion of gamma-ray dose to total dose increased from 0.07 near the surface to 0.09 at 25 cm depth. Due to thermal neutron sensitivity, the G-M count rate inc...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594571
更新日期:1979-05-01 00:00:00
abstract:PURPOSE:As hypoxic cells are more resistant to photon radiation, it is desirable to obtain information about the oxygen distribution in tumors prior to the radiation treatment. Noninvasive techniques are currently not able to provide reliable oxygenation maps with sufficient spatial resolution; therefore mathematical m...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4812431
更新日期:2013-08-01 00:00:00
abstract::Accurate and reliable thermometry is essential in the development of microwave-induced hyperthermal cancer therapy. While temperature measurements in strong electromagnetic fields usually require special sensors, this does not hold true for interstitial radiator/sensor systems. Miniature thermistors (with metallic lea...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595261
更新日期:1983-05-01 00:00:00
abstract:PURPOSE:Motion compensated positron emission tomography (PET) imaging requires detecting and monitoring of patient body motion. We developed a semiautomatic list-mode method to track the three-dimensional (3D) motion of fiducial positron-emitting markers during PET imaging. METHODS:A previously developed motion tracki...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14206
更新日期:2020-08-01 00:00:00
abstract:PURPOSE:X-ray fluorescence computed tomography (XFCT) experiments have typically used pencil beams for data acquisition, which yielded good quality images of gold nanoparticles (AuNP) but prolonged the imaging time. Here we propose three novel collimator geometries for use with faster sheet beam XFCT data acquisition. ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12893
更新日期:2018-06-01 00:00:00
abstract:PURPOSE:One limitation of positron emission tomography (PET) imaging of the torso is patient motion. Motion-compensated image reconstruction (MCIR) is one method employed to reduce the deleterious effects of motion. Existing MCIR algorithms use a single sensitivity correction term, which provides inexact normalization ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3611041
更新日期:2011-09-01 00:00:00
abstract:PURPOSE:Liver segmentation is an important prerequisite for the assessment of liver cancer treatment options like tumor resection, image-guided radiation therapy (IGRT), radiofrequency ablation, etc. The purpose of this work was to evaluate a new approach for liver segmentation. METHODS:A graph cuts segmentation metho...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3682171
更新日期:2012-03-01 00:00:00
abstract:PURPOSE:To develop a computer-driven and thus less user-dependent method, allowing for a simple and straightforward generation of a Monte Carlo (MC) beam model of a scanned proton and carbon ion beam delivery system. METHODS:In a first step, experimental measurements were performed for proton and carbon ion energies i...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14647
更新日期:2020-12-07 00:00:00
abstract:PURPOSE:To develop a hypothesis-generating framework for automatic extraction of dose-outcome relationships from an in-house, analytic oncology database. METHODS:Dose-volume histograms (DVH) and clinical outcomes have been routinely stored to the authors' database for 684 head and neck cancer patients treated from 200...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4922686
更新日期:2015-07-01 00:00:00