Correction of microwave-induced thermistor sensor errors.

Abstract:

:Accurate and reliable thermometry is essential in the development of microwave-induced hyperthermal cancer therapy. While temperature measurements in strong electromagnetic fields usually require special sensors, this does not hold true for interstitial radiator/sensor systems. Miniature thermistors (with metallic leads) bonded to invasive microwave applicators exhibit a sensor error linearly related to the radiator's transmitted power. This relationship permits thermistor sensor error correction and temperature measurements to within +/- 0.1 degrees C or better. The instrumental methods and empirical validation are presented.

journal_name

Med Phys

journal_title

Medical physics

authors

Samaras GM,Rosenbloom S,Cheung AY

doi

10.1118/1.595261

subject

Has Abstract

pub_date

1983-05-01 00:00:00

pages

326-32

issue

3

eissn

0094-2405

issn

2473-4209

journal_volume

10

pub_type

杂志文章
  • Dosimetric effects of needle divergence in prostate seed implant using 125I and 103Pd radioactive seeds.

    abstract::In prostate seed implants, radioactive seeds are implanted into the prostate through a guiding needle with the help of a template and real-time imaging. The ideal locations of the guiding needles and the relative positions of the seeds in each needle are determined before the implantation under the assumption that the...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598971

    authors: Nath S,Chen Z,Yue N,Trumpore S,Peschel R

    更新日期:2000-05-01 00:00:00

  • A doorless entry system for high-energy radiation therapy rooms.

    abstract::A doorless entry system has been designed for use in high-energy radiation therapy rooms. The doorless entry improves patient access, safety and throughput, increases the physical safety for the radiation therapists, and avoids the significant cost of heavy shielding doors. The design meets concerns relating to radiat...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598181

    authors: Dawson DJ,Wissing WW,Tonks RE

    更新日期:1998-02-01 00:00:00

  • On the efficiency of photon beam treatment head simulations.

    abstract::The paper presents a theoretical derivation of the photon fluence simulation efficiency in photon beam treatment head simulations without and with bremsstrahlung splitting. The expressions obtained provide a rigorous explanation of the efficiency dependence on scoring zone size and splitting number and explain the lar...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1943808

    authors: Kawrakow I

    更新日期:2005-07-01 00:00:00

  • A compensative model for the angle-dependence of motion estimates in noninvasive vascular elastography.

    abstract:PURPOSE:Atherosclerosis of peripheral cerebral arteries can lead to stroke either by stenosis formation or plaque rupture. This pathology is initiated by the alteration of arterial wall mechanical properties shown to be assessable by ultrasound elastography. Recently, noninvasive vascular elastography (NIVE) was introd...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3539701

    authors: Mercure E,Deprez JF,Fromageau J,Basset O,Soulez G,Cloutier G,Maurice RL

    更新日期:2011-02-01 00:00:00

  • Technical Note: modification of the standard gain correction algorithm to compensate for the number of used reference flat frames in detector performance studies.

    abstract:PURPOSE:The x-ray performance evaluation of digital x-ray detectors is based on the calculation of the modulation transfer function (MTF), the noise power spectrum (NPS), and the resultant detective quantum efficiency (DQE). The flat images used for the extraction of the NPS should not contain any fixed pattern noise (...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3664003

    authors: Konstantinidis AC,Olivo A,Speller RD

    更新日期:2011-12-01 00:00:00

  • Pretreatment patient-specific IMRT quality assurance: a correlation study between gamma index and patient clinical dose volume histogram.

    abstract:PURPOSE:The aim of this work is to investigate the predictive power of a common conventional intensity modulated radiation therapy (IMRT) quality assurance (QA) performance metric, the gamma passing rate (%GP), through the analysis of the sensitivity and of the correlation between %GP and different dose discrepancies b...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4767763

    authors: Stasi M,Bresciani S,Miranti A,Maggio A,Sapino V,Gabriele P

    更新日期:2012-12-01 00:00:00

  • Dual-energy x-ray projection imaging: two sampling schemes for the correction of scattered radiation.

    abstract::In addition to the familiar problems of reduced contrast and signal-to-noise ratio (SNR) in the single energy case, dual-energy subtractions in the presence of scattered radiation suffer further degradations from: (1) artifacts due to nonuniform subtraction of scatter, and (2) a serious deterioration of the signal of ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596188

    authors: Wagner FC,Macovski A,Nishimura DG

    更新日期:1988-09-01 00:00:00

  • Effect of finite sample size on feature selection and classification: a simulation study.

    abstract:PURPOSE:The small number of samples available for training and testing is often the limiting factor in finding the most effective features and designing an optimal computer-aided diagnosis (CAD) system. Training on a limited set of samples introduces bias and variance in the performance of a CAD system relative to that...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3284974

    authors: Way TW,Sahiner B,Hadjiiski LM,Chan HP

    更新日期:2010-02-01 00:00:00

  • Development and clinical evaluation of an ionization chamber array with 3.5 mm pixel pitch for quality assurance in advanced radiotherapy techniques.

    abstract:PURPOSE:To characterize a new air vented ionization chamber technology, suitable to build detector arrays with small pixel pitch and independence of sensitivity on dose per pulse. METHODS:The prototype under test is a linear array of air vented ionization chambers, consisting of 80 pixels with 3.5 mm pixel pitch dista...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4945414

    authors: Togno M,Wilkens JJ,Menichelli D,Oechsner M,Perez-Andujar A,Morin O

    更新日期:2016-05-01 00:00:00

  • SU-E-J-115: Graticule for Verification of Treatment Position in Neutron Therapy.

    abstract:PURPOSE:Until recently the treatment verification for patients undergoing fast neutron therapy at our facility was accomplished through a combination of neutron beam portal films aligned with a graticule mounted on an orthronormal x-ray tube. To eliminate uncertainty with respect to the relative positions of the x-ray ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734951

    authors: Halford R,Snyder M

    更新日期:2012-06-01 00:00:00

  • A boundary element approach for image-guided near-infrared absorption and scatter estimation.

    abstract::Multimodality NIR spectroscopy systems offer the possibility of region-based vascular and molecular characterization of tissue in vivo. However, computationally efficient 3D image reconstruction algorithms specific to these image-guided systems currently do not exist. Image reconstruction is often based on finite-elem...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2795832

    authors: Srinivasan S,Pogue BW,Carpenter C,Yalavarthy PK,Paulsen K

    更新日期:2007-11-01 00:00:00

  • Sheet beam x-ray fluorescence computed tomography (XFCT) imaging of gold nanoparticles.

    abstract:PURPOSE:X-ray fluorescence computed tomography (XFCT) experiments have typically used pencil beams for data acquisition, which yielded good quality images of gold nanoparticles (AuNP) but prolonged the imaging time. Here we propose three novel collimator geometries for use with faster sheet beam XFCT data acquisition. ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12893

    authors: Dunning CAS,Bazalova-Carter M

    更新日期:2018-06-01 00:00:00

  • A two-step algorithm for predicting portal dose images in arbitrary detectors.

    abstract::Recently, portal imaging systems have been successfully demonstrated in dosimetric treatment verification applications, where measured and predicted images are quantitatively compared. To advance this approach to dosimetric verification, a two-step model which predicts dose deposition in arbitrary portal image detecto...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1289375

    authors: McCurdy BM,Pistorius S

    更新日期:2000-09-01 00:00:00

  • Assessment of the spectral performance of hybrid photon counting x-ray detectors.

    abstract:PURPOSE:Hybrid Photon Counting (HPC) detectors profoundly improved x-ray diffraction experiments at third generation synchrotron facilities. Enabling the simultaneous measurement of x-ray intensities in multiple energy bins, they also have many potential applications in the field of medical imaging. A prerequisite for ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12323

    authors: Trueb P,Zambon P,Broennimann C

    更新日期:2017-09-01 00:00:00

  • Image segmentation with a novel regularized composite shape prior based on surrogate study.

    abstract:PURPOSE:Incorporating training into image segmentation is a good approach to achieve additional robustness. This work aims to develop an effective strategy to utilize shape prior knowledge, so that the segmentation label evolution can be driven toward the desired global optimum. METHODS:In the variational image segmen...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4945046

    authors: Zhao T,Ruan D

    更新日期:2016-05-01 00:00:00

  • Use of the fast Hartley transform for three-dimensional dose calculation in radionuclide therapy.

    abstract::Effective radioimmunotherapy may depend on a priori knowledge of the radiation absorbed dose distribution obtained by trace imaging activities administered to a patient before treatment. A new, fast, and effective treatment planning approach is developed to deal with a heterogeneous activity distribution. Calculation ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598422

    authors: Erdi AK,Yorke ED,Loew MH,Erdi YE,Sarfaraz M,Wessels BW

    更新日期:1998-11-01 00:00:00

  • Oxygen distribution in tumors: a qualitative analysis and modeling study providing a novel Monte Carlo approach.

    abstract:PURPOSE:To construct a Monte Carlo (MC)-based simulation model for analyzing the dependence of tumor oxygen distribution on different variables related to tumor vasculature [blood velocity, vessel-to-vessel proximity (vessel proximity), and inflowing oxygen partial pressure (pO2)]. METHODS:A voxel-based tissue model c...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4892386

    authors: Lagerlöf JH,Kindblom J,Bernhardt P

    更新日期:2014-09-01 00:00:00

  • First clinical implementation of real-time, real anatomy tracking and radiation beam control.

    abstract:PURPOSE:We describe the acceptance testing, commissioning, periodic quality assurance, and workflow procedures developed for the first clinically implemented magnetic resonance imaging-guided radiation therapy (MR-IGRT) system for real-time tracking and beam control. METHODS:The system utilizes real-time cine imaging ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13002

    authors: Green OL,Rankine LJ,Cai B,Curcuru A,Kashani R,Rodriguez V,Li HH,Parikh PJ,Robinson CG,Olsen JR,Mutic S,Goddu SM,Santanam L

    更新日期:2018-05-28 00:00:00

  • Influence of phantom diameter, kVp and scan mode upon computed tomography dose index.

    abstract::The computed tomography (CT) radiation dose to pediatric patients has received considerable attention recently. Moreover, it is important to be able to determine CT radiation doses for various patient sizes ranging from infants to large adults. The current AAPM protocol only measures CT radiation dose using a 16 cm ac...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1543149

    authors: Nickoloff EL,Dutta AK,Lu ZF

    更新日期:2003-03-01 00:00:00

  • The effect of rectal heterogeneity on wall dose in high dose rate brachytherapy.

    abstract::When treating prostate cancer using high dose rate (HDR) brachytherapy, overdosing the rectal wall may lead to post-treatment rectal complications. An area of concern is related to how the rectal wall dose is calculated by treatment planning systems (TPSs). TPSs are used to calculate the dose delivered to the rectal w...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3031111

    authors: Kwan IS,Wilkinson D,Cutajar D,Lerch M,Rosenfeld A,Howie A,Bucci J,Chin Y,Perevertaylo VL

    更新日期:2009-01-01 00:00:00

  • GLAaS: an absolute dose calibration algorithm for an amorphous silicon portal imager. Applications to IMRT verifications.

    abstract::A new calibration algorithm (GLAaS) to derive absolute dose maps from images acquired with the Varian PV-aS500 electronic portal imager (based on amorphous silicon detectors) has been developed incorporating the dependence of detector response on primary and transmitted radiation and on field size. Detector calibratio...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2218314

    authors: Nicolini G,Fogliata A,Vanetti E,Clivio A,Cozzi L

    更新日期:2006-08-01 00:00:00

  • Soft-tissue detectability in cone-beam CT: evaluation by 2AFC tests in relation to physical performance metrics.

    abstract::Soft-tissue detectability in cone-beam computed tomography (CBCT) was evaluated via two-alternative forced-choice (2AFC) tests. Investigations included the dependence of detectability on radiation dose, the influence of the asymmetric three-dimensional (3D) noise-power spectrum (NPS) in axial and sagittal or coronal p...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2790586

    authors: Tward DJ,Siewerdsen JH,Daly MJ,Richard S,Moseley DJ,Jaffray DA,Paul NS

    更新日期:2007-11-01 00:00:00

  • SU-E-J-192: Static Breath-Hold MRI Based Measurement of Change in Pulmonary Function Following a Course of Radiation Therapy.

    abstract:PURPOSE:Radiation Therapy (RT) induced pulmonary function change may depend on the location, underlying function of that lung prior to radiations, radiation dose/fractionation and other factors. We propose to evaluate the radiation induced pulmonary function change using static breath-hold MRI scans with vascular infor...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735033

    authors: Ding K,Cao K,Du K,Chen Q,Ennis D,Christensen G,Reinhardt J,Libby B,Benedict S,Sheng K

    更新日期:2012-06-01 00:00:00

  • Continuous time-dependence in computed tomography.

    abstract::Computed tomography is sensitive to changes in the imaged distribution during acquisition of the projection data. Previous investigations have emphasized discrete or discontinuous changes in the imaged object. Recent advances have motivated our investigation of object time-dependence characterized by a continuous func...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594458

    authors: Holden JE,Ip WR

    更新日期:1978-11-01 00:00:00

  • Plan averaging for multicriteria navigation of sliding window IMRT and VMAT.

    abstract:PURPOSE:To describe a method for combining sliding window plans [intensity modulated radiation therapy (IMRT) or volumetric modulated arc therapy (VMAT)] for use in treatment plan averaging, which is needed for Pareto surface navigation based multicriteria treatment planning. METHODS:The authors show that by taking an...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4859295

    authors: Craft D,Papp D,Unkelbach J

    更新日期:2014-02-01 00:00:00

  • Localization of cochlear implant electrodes in radiographs.

    abstract::Multielectrode cochlear implantation is the most effective treatment for profound sensorineural hearing loss. In vivo three-dimensional 3-D localization of cochlear implant electrodes is important for modeling of the electrical field in the cochlea, design of electrode arrays, and may improve speech processor programm...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598940

    authors: Yang S,Wang G,Skinner MW,Rubinstein JT,Vannier MW

    更新日期:2000-04-01 00:00:00

  • Dose buildup for obliquely incident photon beams.

    abstract::For obliquely incident photon beams, the buildup of dose with depth is markedly different from normally incident beams. However, relatively little data on this topic exists for high-energy photon beams of energy greater than 6 MV. Measurements of dose in the buildup region were made using a plane-parallel ionization c...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596055

    authors: Gerbi BJ,Meigooni AS,Khan FM

    更新日期:1987-05-01 00:00:00

  • FRoG: An independent dose and LETd prediction tool for proton therapy at ProBeam® facilities.

    abstract:PURPOSE:Particle therapy is becoming increasingly available world-wide for precise tumor targeting, its favorable depth dose deposition, and increased biological damage to tumor tissue compared to conventional photon therapy. As demand increases for improved robustness and conformality, next-generation secondary dose c...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14417

    authors: Kopp B,Fuglsang Jensen M,Mein S,Hoffmann L,Nyström H,Falk M,Haberer T,Abdollahi A,Debus J,Mairani A

    更新日期:2020-10-01 00:00:00

  • Correspondence optimization in 2D standardized carotid wall thickness map by description length minimization: A tool for increasing reproducibility of 3D ultrasound-based measurements.

    abstract:PURPOSE:The previously described 2D standardized vessel-wall-plus-plaque thickness (VWT) maps constructed from 3D ultrasound vessel wall measurements using an arc-length (AL) scaling approach adjusted the geometric variability of carotid arteries and has allowed for the comparisons of VWT distributions in longitudinal ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4966702

    authors: Chen Y,Chiu B

    更新日期:2016-12-01 00:00:00

  • A separable quadratic surrogate total variation minimization algorithm for accelerating accurate CT reconstruction from few-views and limited-angle data.

    abstract:PURPOSE:Total variation minimization (TVM) is a popular and useful method for accurate CT reconstruction from few-views and limited-angle data. However, the optimization procedure of previous TVM-based algorithms is very time-consuming. The purpose of this paper was to accelerate the high image quality CT reconstructio...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12692

    authors: Hou X,Teng Y,Kang Y,Qi S

    更新日期:2018-02-01 00:00:00