SU-E-J-115: Graticule for Verification of Treatment Position in Neutron Therapy.

Abstract:

PURPOSE:Until recently the treatment verification for patients undergoing fast neutron therapy at our facility was accomplished through a combination of neutron beam portal films aligned with a graticule mounted on an orthronormal x-ray tube. To eliminate uncertainty with respect to the relative positions of the x-ray graticule and the therapy beam, we have developed a graticule which is placed in the neutron beam itself. METHODS:For a graticule to be visible on the portal film, the attenuation of the neutron beam by the graticule landmarks must be significantly greater than that of the material in which the landmarks are mounted. Various materials, thicknesses, and mounting points were tried to gain the largest contrast between the graticule landmarks and the mounting material. RESULTS:The final design involved 2 inch steel pins of 0.125 inch diameter captured between two parallel plates of 0.25 inch thick clear acrylic plastic. The distance between the two acrylic plates was 1.625 inches, held together at the perimeter with acrylic sidewall spacers. This allowed the majority of length of the steel pins to be surrounded by air. The pins were set 1 cm apart and mounted at angles parallel to the divergence of the beam dependent on their position within the array. The entire steel pin and acrylic plate assembly was mounted on an acrylic accessory tray to allow for graticule alignment. CONCLUSION:Despite the inherent difficulties in attenuating fast neutrons, our simple graticule design produces the required difference of attenuation between the arrays of landmarks and the mounting material. The graticule successfully provides an in-beam frame of reference for patient portal verification.

journal_name

Med Phys

journal_title

Medical physics

authors

Halford R,Snyder M

doi

10.1118/1.4734951

subject

Has Abstract

pub_date

2012-06-01 00:00:00

pages

3679

issue

6Part7

eissn

0094-2405

issn

2473-4209

journal_volume

39

pub_type

杂志文章
  • SU-E-T-144: Daily and Monthly Quality Assurance with TomoDose.

    abstract:PURPOSE:Examine the use of TomoDose for Tomotherapy quality assurance. METHODS:Baseline TomoDose profiles are acquired annually in accordance with TG-148. During monthly quality assurance, TomoDose is irradiated with a static beam and referenced to baseline. Differences between superimposed profiles are evaluated mont...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735202

    authors: Terrell J

    更新日期:2012-06-01 00:00:00

  • Characterization of mesothelioma and tissues present in contrast-enhanced thoracic CT scans.

    abstract:PURPOSE:The purpose of this study was to characterize the Hounsfield unit (HU) distributions of mesothelioma and other tissues present in contrast-enhanced thoracic CT scans, to compare the HU distributions of mesothelioma, muscle, and liver by scanner and reconstruction filter/kernel combination, and to assess interpa...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3537610

    authors: Corson N,Sensakovic WF,Straus C,Starkey A,Armato SG 3rd

    更新日期:2011-02-01 00:00:00

  • Oxygen distribution in tumors: a qualitative analysis and modeling study providing a novel Monte Carlo approach.

    abstract:PURPOSE:To construct a Monte Carlo (MC)-based simulation model for analyzing the dependence of tumor oxygen distribution on different variables related to tumor vasculature [blood velocity, vessel-to-vessel proximity (vessel proximity), and inflowing oxygen partial pressure (pO2)]. METHODS:A voxel-based tissue model c...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4892386

    authors: Lagerlöf JH,Kindblom J,Bernhardt P

    更新日期:2014-09-01 00:00:00

  • Continuous time-dependence in computed tomography.

    abstract::Computed tomography is sensitive to changes in the imaged distribution during acquisition of the projection data. Previous investigations have emphasized discrete or discontinuous changes in the imaged object. Recent advances have motivated our investigation of object time-dependence characterized by a continuous func...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594458

    authors: Holden JE,Ip WR

    更新日期:1978-11-01 00:00:00

  • Resolution of pinhole collimators used with gamma cameras.

    abstract::The line spread function (LSF) of an imaging system incorporating a pinhole of 0.275 cm radius and a scintillation camera has been measured and its full width at half maximum (FWHM) compared to the values predicted by an expression based on the resolution index of Anger. In most cases, the actual resolution of the sys...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594755

    authors: Goulet P,Joy ML

    更新日期:1980-09-01 00:00:00

  • CUDA-based acceleration and BPN-assisted automation of bilateral filtering for brain MR image restoration.

    abstract:PURPOSE:Bilateral filters have been substantially exploited in numerous magnetic resonance (MR) image restoration applications for decades. Due to the deficiency of theoretical basis on the filter parameter setting, empirical manipulation with fixed values and noise variance-related adjustments has generally been emplo...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12157

    authors: Chang HH,Chang YN

    更新日期:2017-04-01 00:00:00

  • Technical Note: Evaluation of a 160-mm/256-row CT scanner for whole-heart quantitative myocardial perfusion imaging.

    abstract:PURPOSE:The authors investigated the performance of a recently introduced 160-mm/256-row CT system for low dose quantitative myocardial perfusion (MP) imaging of the whole heart. This platform is equipped with a gantry capable of rotating at 280 ms per full cycle, a second generation of adaptive statistical iterative r...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4957389

    authors: So A,Imai Y,Nett B,Jackson J,Nett L,Hsieh J,Wisenberg G,Teefy P,Yadegari A,Islam A,Lee TY

    更新日期:2016-08-01 00:00:00

  • Iodine kinetics and dosimetry in the salivary glands during repeated courses of radioiodine therapy for thyroid cancer.

    abstract:PURPOSE:The present study was conducted to investigate salivary iodine kinetics and dosimetry during repeated courses of radioiodine ((131)I) therapy for differentiated thyroid cancer (DTC). Such data could provide a better understanding of the mechanisms of (131)I induced salivary toxicity and help to develop appropri...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3602459

    authors: Liu B,Huang R,Kuang A,Zhao Z,Zeng Y,Wang J,Tian R

    更新日期:2011-10-01 00:00:00

  • High resolution 2D dose measurement device based on a few long scintillating fibers and tomographic reconstruction.

    abstract:PURPOSE:Patient-specific QA of highly conformal radiotherapy treatments are usually conducted using 2D or 3D dosimetry of the incident dose distribution in a water-equivalent phantom. However, dosimeters typically used for this task usually lack in either spatial resolution or dose accuracy. The purpose of this work is...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4736526

    authors: Goulet M,Archambault L,Beaulieu L,Gingras L

    更新日期:2012-08-01 00:00:00

  • Automatic measurements of image geometry for online calibration of C-arm fluoroscopy.

    abstract::Calibrated C-arm fluoroscopy is used for a variety of surgical procedures where surgical tools and anatomical structures need to be located in space. Calibration can be performed online by combining measurements of the geometry of the image (center and radius) with measurements of a grid of fiducial markers. This arti...

    journal_title:Medical physics

    pub_type: 杂志文章,多中心研究

    doi:10.1118/1.1781331

    authors: Archip N,Rohling R

    更新日期:2004-09-01 00:00:00

  • Variability of tumor area measurements for response assessment in malignant pleural mesothelioma.

    abstract:PURPOSE:The measurement of malignant pleural mesothelioma is critical to the assessment of tumor response to therapy. Current response assessment standards utilize summed linear measurements acquired on three computed tomography (CT) sections. The purpose of this study was to evaluate manual area measurements as an alt...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4810940

    authors: Labby ZE,Straus C,Caligiuri P,MacMahon H,Li P,Funaki A,Kindler HL,Armato SG 3rd

    更新日期:2013-08-01 00:00:00

  • Average glandular dose coefficients for pendant-geometry breast CT using realistic breast phantoms.

    abstract:PURPOSE:To design volume-specific breast phantoms from breast CT (bCT) data sets and estimate the associated normalized mean glandular dose coefficients for breast CT using Monte Carlo methods. METHODS:A large cohort of bCT data sets (N = 215) was used to evaluate breast volume into quintiles (plus the top 5%). The av...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12477

    authors: Hernandez AM,Boone JM

    更新日期:2017-10-01 00:00:00

  • Three dimensional intensity modulated brachytherapy (IMBT): dosimetry algorithm and inverse treatment planning.

    abstract:PURPOSE:The feasibility of intensity modulated brachytherapy (IMBT) to improve dose conformity for irregularly shaped targets has been previously investigated by researchers by means of using partially shielded sources. However, partial shielding does not fully explore the potential of IMBT. The goal of this study is t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3456598

    authors: Shi C,Guo B,Cheng CY,Esquivel C,Eng T,Papanikolaou N

    更新日期:2010-07-01 00:00:00

  • Comparison of an amorphous silicon/cesium iodide flat-panel digital chest radiography system with screen/film and computed radiography systems--a contrast-detail phantom study.

    abstract::Flat-panel (FP) based digital radiography systems have recently been introduced as a new and improved digital radiography technology; it is important to evaluate and compare this new technology with currently widely used conventional screen/film (SF) and computed radiography (CR) techniques. In this study, the low-con...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1408620

    authors: Rong XJ,Shaw CC,Liu X,Lemacks MR,Thompson SK

    更新日期:2001-11-01 00:00:00

  • Multipinhole collimator with 20 apertures for a brain SPECT application.

    abstract:PURPOSE:Several new technologies for single photon emission computed tomography (SPECT) instrumentation with parallel-hole collimation have been proposed to improve detector sensitivity and signal collection efficiency. Benefits from improved signal efficiency include shorter acquisition times and lower dose requiremen...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4897567

    authors: Lee TC,Ellin JR,Huang Q,Shrestha U,Gullberg GT,Seo Y

    更新日期:2014-11-01 00:00:00

  • Radiation dose to the lungs from ventilation studies with 133Xe.

    abstract::The radiation dose to the lungs from 133Xe in lung air is directly proportional to the time integral of 133Xe concentration; i.e., the cumulated concentration in the lungs. Using kinetic models developed to fit clinical observations, we have studied the effect of retention on cumulated concentration in lung air. The m...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594341

    authors: Watson EE,Cloutier RJ

    更新日期:1977-11-01 00:00:00

  • A beam intensity monitor for the Loma Linda cancer therapy proton accelerator.

    abstract::A beam intensity monitor was tested in a 230-MeV proton beam at the Loma Linda Proton Therapy Accelerator during its commissioning at Fermi National Accelerator Laboratory. The intensity monitor was designed to regulate the beam intensity extracted from the proton synchrotron. The proton beam is tunable between 70 and...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596636

    authors: Coutrakon G,Miller D,Kross BJ,Anderson DF,DeLuca P Jr,Siebers J

    更新日期:1991-07-01 00:00:00

  • Quantitative study of focused ultrasound enhanced doxorubicin delivery to prostate tumor in vivo with MRI guidance.

    abstract:PURPOSE:The purpose of this study was to investigate the potential of MR-guided pulsed focused ultrasound (pFUS) for the enhancement of drug uptake in prostate tumors in vivo using doxorubicin (Dox). METHODS:An antitumor drug Dox, an orthotopic animal prostate tumor model using human prostate cancer, LNCaP cell line, ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4705346

    authors: Chen X,Cvetkovic D,Ma CM,Chen L

    更新日期:2012-05-01 00:00:00

  • An experimental palladium-103 seed (OptiSeedexp) in a biocompatible polymer without a gold marker: characterization of dosimetric parameters including the interseed effect.

    abstract::Permanent implantation of 125I (iodine) or 103Pd (palladium) sources is a popular treatment option in the management of early stage prostate cancer. New sources are being developed, some of which are being marketed for different clinical applications. A new technique of adjuvant stereotactic permanent seed breast impl...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3006151

    authors: Abboud F,Scalliet P,Vynckier S

    更新日期:2008-12-01 00:00:00

  • Dose-averaged LET calculation for proton track segments using microdosimetric Monte Carlo simulations.

    abstract:PURPOSE:There is an increasing interest in calculating linear energy transfer (LET) distributions for proton therapy treatments in order to assess the influence of this quantity in biological terms. Microdosimetric Monte Carlo (MC) simulations are useful tools to calculate dose-averaged LET, as this has been broadly pr...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13643

    authors: Bertolet A,Baratto-Roldán A,Barbieri S,Baiocco G,Carabe A,Cortés-Giraldo MA

    更新日期:2019-09-01 00:00:00

  • Air core detectors for Cerenkov-free scintillation dosimetry of brachytherapy β-sources.

    abstract:PURPOSE:Plastic scintillation detectors are used for dosimetry in small radiation fields with high dose gradients, e.g., provided by β-emitting sources like 106 Ru/106 Rh eye plaques. A drawback is a background signal caused by Cerenkov radiation generated by electrons passing the optical fibers (light guides) of this ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12374

    authors: Eichmann M,Thomann B

    更新日期:2017-09-01 00:00:00

  • Dosimetric problems at low monitor unit settings for scanned and scattering foil electron beams.

    abstract::Electron beam dosimetry at low monitor unit (MU) settings is important for dosimetric applications. Dose linearity, beam flatness, and beam energies were studied at low MU settings with various dose rates for different types of linear accelerators. It is observed that for the scattering foil units, the dose/MU is a sm...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597328

    authors: Das IJ,Harrington JC,Akber SF,Tomer AF,Murray JC,Cheng CW

    更新日期:1994-06-01 00:00:00

  • Assessment of the limiting spatial resolution of an MRI scanner by direct analysis of the edge spread function.

    abstract::Limiting spatial resolution is a key metric of the quality of magnetic resonance (MR) images, which can provide an indication of the smallest region that can effectively be imaged. In this paper a novel methodology for measuring the limiting spatial resolution of MR images is mathematically analyzed and successfully i...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3097633

    authors: Delakis I,Xanthis C,Kitney RI

    更新日期:2009-05-01 00:00:00

  • Efficient generation of a magnetic field-free line.

    abstract:PURPOSE:Signal encoding in magnetic particle imaging (MPI) is achieved by moving a field-free point (FFP) through the region of interest. One way to increase the sensitivity of the method is to scan the region of interest with a field-free line (FFL) instead of the FFP. Recently, the first feasible FFL coil setup was i...

    journal_title:Medical physics

    pub_type: 信件

    doi:10.1118/1.3447726

    authors: Knopp T,Erbe M,Biederer S,Sattel TF,Buzug TM

    更新日期:2010-07-01 00:00:00

  • Improved tissue assignment using dual-energy computed tomography in low-dose rate prostate brachytherapy for Monte Carlo dose calculation.

    abstract:PURPOSE:An improvement in tissue assignment for low-dose rate brachytherapy (LDRB) patients using more accurate Monte Carlo (MC) dose calculation was accomplished with a metallic artifact reduction (MAR) method specific to dual-energy computed tomography (DECT). METHODS:The proposed MAR algorithm followed a four-step ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4947486

    authors: Côté N,Bedwani S,Carrier JF

    更新日期:2016-05-01 00:00:00

  • An investigation of a new amorphous silicon electronic portal imaging device for transit dosimetry.

    abstract::The relationship between the pixel value and exit dose was investigated for a new commercially available amorphous silicon electronic portal imaging device. The pixel to dose mapping function was established to be linear for detector distances between 116.5 cm to 150 cm from the source, radiation field sizes from 5 x ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1508108

    authors: Grein EE,Lee R,Luchka K

    更新日期:2002-10-01 00:00:00

  • Sensitivity of amorphous selenium to x rays from 40 kVp to 18 MV: measurements and implications for portal imaging.

    abstract::Recently, the clinical application of electronic portal imaging devices has enabled more frequent verification of patient setup for radiation treatment. However, the image quality has sometimes proven to be inadequate, motivating the investigation of alternative sensors with better image quality. Amorphous selenium (a...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598219

    authors: Mah D,Rowlands JA,Rawlinson JA

    更新日期:1998-04-01 00:00:00

  • Bremsstrahlung production at 50 MeV in different target materials and configurations.

    abstract::A combination of Monte Carlo, convolution, and experimental techniques have been used to investigate bremsstrahlung production at 50 MeV in full-range targets to produce narrow elementary photon beams for scanning. Calculations using the ITS 3.0 Monte Carlo system for various target designs, including particle transpo...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597681

    authors: Sätherberg A,Andreo P,Karlsson M

    更新日期:1996-04-01 00:00:00

  • Sample size requirements for estimating effective dose from computed tomography using solid-state metal-oxide-semiconductor field-effect transistor dosimetry.

    abstract:PURPOSE:Effective dose (ED) is a widely used metric for comparing ionizing radiation burden between different imaging modalities, scanners, and scan protocols. In computed tomography (CT), ED can be estimated by performing scans on an anthropomorphic phantom in which metal-oxide-semiconductor field-effect transistor (M...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4868693

    authors: Trattner S,Cheng B,Pieniazek RL,Hoffmann U,Douglas PS,Einstein AJ

    更新日期:2014-04-01 00:00:00

  • 3D modeling of effects of increased oxygenation and activity concentration in tumors treated with radionuclides and antiangiogenic drugs.

    abstract:PURPOSE:Formation of new blood vessels (angiogenesis) in response to hypoxia is a fundamental event in the process of tumor growth and metastatic dissemination. However, abnormalities in tumor neovasculature often induce increased interstitial pressure (IP) and further reduce oxygenation (pO2) of tumor cells. In radiot...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3615164

    authors: Lagerlöf JH,Kindblom J,Bernhardt P

    更新日期:2011-08-01 00:00:00