Sample size requirements for estimating effective dose from computed tomography using solid-state metal-oxide-semiconductor field-effect transistor dosimetry.

Abstract:

PURPOSE:Effective dose (ED) is a widely used metric for comparing ionizing radiation burden between different imaging modalities, scanners, and scan protocols. In computed tomography (CT), ED can be estimated by performing scans on an anthropomorphic phantom in which metal-oxide-semiconductor field-effect transistor (MOSFET) solid-state dosimeters have been placed to enable organ dose measurements. Here a statistical framework is established to determine the sample size (number of scans) needed for estimating ED to a desired precision and confidence, for a particular scanner and scan protocol, subject to practical limitations. METHODS:The statistical scheme involves solving equations which minimize the sample size required for estimating ED to desired precision and confidence. It is subject to a constrained variation of the estimated ED and solved using the Lagrange multiplier method. The scheme incorporates measurement variation introduced both by MOSFET calibration, and by variation in MOSFET readings between repeated CT scans. Sample size requirements are illustrated on cardiac, chest, and abdomen-pelvis CT scans performed on a 320-row scanner and chest CT performed on a 16-row scanner. RESULTS:Sample sizes for estimating ED vary considerably between scanners and protocols. Sample size increases as the required precision or confidence is higher and also as the anticipated ED is lower. For example, for a helical chest protocol, for 95% confidence and 5% precision for the ED, 30 measurements are required on the 320-row scanner and 11 on the 16-row scanner when the anticipated ED is 4 mSv; these sample sizes are 5 and 2, respectively, when the anticipated ED is 10 mSv. CONCLUSIONS:Applying the suggested scheme, it was found that even at modest sample sizes, it is feasible to estimate ED with high precision and a high degree of confidence. As CT technology develops enabling ED to be lowered, more MOSFET measurements are needed to estimate ED with the same precision and confidence.

journal_name

Med Phys

journal_title

Medical physics

authors

Trattner S,Cheng B,Pieniazek RL,Hoffmann U,Douglas PS,Einstein AJ

doi

10.1118/1.4868693

subject

Has Abstract

pub_date

2014-04-01 00:00:00

pages

042102

issue

4

eissn

0094-2405

issn

2473-4209

journal_volume

41

pub_type

杂志文章
  • Thermal limits on MV x-ray production by bremsstrahlung targets in the context of novel linear accelerators.

    abstract:PURPOSE:To study the impact of target geometrical and linac operational parameters, such as target material and thickness, electron beam size, repetition rate, and mean current on the ability of the radiotherapy treatment head to deliver high-dose-rate x-ray irradiation in the context of novel linear accelerators capab...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12615

    authors: Wang J,Trovati S,Borchard PM,Loo BW Jr,Maxim PG,Fahrig R

    更新日期:2017-12-01 00:00:00

  • Development of optical process for accessing three-dimensional patient topology.

    abstract::A commercial optical system developed by Solid Photography, Inc., has been used to generate precise paraffin--polyethylene tissue compensators. A program with the objective of constructing a medical facility has been undertaken to access patient topology for treatment planning, tissue-compensator fabrication, and pati...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594447

    authors: Lerch IA,Barish RJ,Stern H

    更新日期:1978-11-01 00:00:00

  • Quantitation of SPECT performance: Report of Task Group 4, Nuclear Medicine Committee.

    abstract::A comprehensive performance testing program is an essential ingredient of high-quality single-photon emission computed tomography (SPECT). Many of the procedures previously published are complicated, time consuming, or require a special testing environment. This Task Group developed a protocol for evaluating SPECT ima...

    journal_title:Medical physics

    pub_type: 指南,杂志文章

    doi:10.1118/1.597605

    authors: Graham LS,Fahey FH,Madsen MT,van Aswegen A,Yester MV

    更新日期:1995-04-01 00:00:00

  • Improvement of off-axis SABR plan verification results by using adapted dose reconstruction algorithms for the Octavius 4D system.

    abstract:PURPOSE:Stereotactic ablative body radiotherapy (SABR) for lung patients can be performed with volumetric-modulated arc therapy (VMAT) plans using off-axis target geometry to allow treatment in their CBCT verified position. For patient-specific quality assurance measurements using the PTW Octavius 4D phantom (PTW, Frei...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12805

    authors: Jeevanandam P,Agnew CE,Irvine DM,McGarry CK

    更新日期:2018-04-01 00:00:00

  • Improved MAGIC gel for higher sensitivity and elemental tissue equivalent 3D dosimetry.

    abstract:PURPOSE:Polymer-based gel dosimeter (MAGIC type) is a preferable phantom material for PET range verification of proton beam therapy. However, improvement in elemental tissue equivalency (specifically O/C ratio) is very desirable to ensure realistic time-activity measurements. METHODS:Glucose and urea was added to the ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3260844

    authors: Zhu X,Reese TG,Crowley EM,El Fakhri G

    更新日期:2010-01-01 00:00:00

  • Monte Carlo study of ionization chamber magnetic field correction factors as a function of angle and beam quality.

    abstract:PURPOSE:To use EGSnrc Monte Carlo simulations for magnetic field dosimetry to determine optimal measurement orientations, calculate beam quality conversion factors for 32 cylindrical and three parallel-plate (PP) ion chambers, evaluate the beam quality and angular dependence of these factors, and examine the magnetic f...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12716

    authors: Malkov VN,Rogers DWO

    更新日期:2018-02-01 00:00:00

  • Correcting and reweighting false label masks in brain tumor segmentation.

    abstract:PURPOSE:Recently, brain tumor segmentation has made important progress. However, the quality of manual labels plays an important role in the performance, while in practice, it could vary greatly and in turn could substantially mislead the learning process and decrease the accuracy. We need to design a mechanism to comb...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14480

    authors: Cheng G,Ji H,He L

    更新日期:2020-09-24 00:00:00

  • A real-time prostate cancer detection technique using needle insertion force and patient-specific criteria during percutaneous intervention.

    abstract::In this article, the authors present a novel real-time cancer detection technique by using needle insertion forces in conjunction with patient-specific criteria during percutaneous interventions. Needle insertion experiments and pathological analysis were performed for developing a computer-aided detection (CAD) model...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3148834

    authors: Yan K,Li L,Joseph J,Rubens DR,Messing EM,Liao L,Yu Y

    更新日期:2009-07-01 00:00:00

  • Comparisons of treatment optimization directly incorporating random patient setup uncertainty with a margin-based approach.

    abstract::The purpose of this study is to incorporate the dosimetric effect of random patient positioning uncertainties directly into a commercial treatment planning system's IMRT plan optimization algorithm through probabilistic treatment planning (PTP) and compare coverage of this method with margin-based planning. In this wo...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3176940

    authors: Moore JA,Gordon JJ,Anscher MS,Siebers JV

    更新日期:2009-09-01 00:00:00

  • Dosimetric problems at low monitor unit settings for scanned and scattering foil electron beams.

    abstract::Electron beam dosimetry at low monitor unit (MU) settings is important for dosimetric applications. Dose linearity, beam flatness, and beam energies were studied at low MU settings with various dose rates for different types of linear accelerators. It is observed that for the scattering foil units, the dose/MU is a sm...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597328

    authors: Das IJ,Harrington JC,Akber SF,Tomer AF,Murray JC,Cheng CW

    更新日期:1994-06-01 00:00:00

  • SU-E-J-157: Simulation and Design of a Real-Time 6D Head Motion Compensation Platform Based on a Stewart Platform Approach.

    abstract:PURPOSE:Real-time sub-millimeter head motion compensation during frameless SRS delivery has the potential to achieve the accuracy of frame-based SRS while being significantly less invasive. Previously, we demonstrated real-time 6D head motion monitoring using an optical camera, however, at the time we were limited to o...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734995

    authors: Belcher AH,Wiersma RD

    更新日期:2012-06-01 00:00:00

  • Transcranial phase aberration correction using beam simulations and MR-ARFI.

    abstract:PURPOSE:Transcranial magnetic resonance-guided focused ultrasound surgery is a noninvasive technique for causing selective tissue necrosis. Variations in density, thickness, and shape of the skull cause aberrations in the location and shape of the focal zone. In this paper, the authors propose a hybrid simulation-MR-AR...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4865778

    authors: Vyas U,Kaye E,Pauly KB

    更新日期:2014-03-01 00:00:00

  • Poster - Thurs Eve-38: CT Imaging in high dose rate brachytherapy for treatment of cervical cancer: Estimation of dose to bowel.

    abstract::Treatment of cervical cancer often involves intracavitary high dose rate (HDR) brachytherapy. Dose delivered to the bladder and rectum are typically estimated using the ICRU reference points. Dose to the sigmoid and small bowel are not estimated, yet these organs typically exhibit significant complication rates. The o...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2965957

    authors: Lekx-Toniolo KS,Hunter R,Patel M,Voruganti S,Johanson C,Dhamanaskar K,Farrell T

    更新日期:2008-07-01 00:00:00

  • Evaluation of three types of reference image data for external beam radiotherapy target localization using digital tomosynthesis (DTS).

    abstract::Digital tomosynthesis (DTS) is a fast, low-dose three-dimensional (3D) imaging approach which yields slice images with excellent in-plane resolution, though low plane-to-plane resolution. A stack of DTS slices can be reconstructed from a single limited-angle scan, with typical scan angles ranging from 10 degrees to 40...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2756941

    authors: Godfrey DJ,Ren L,Yan H,Wu Q,Yoo S,Oldham M,Yin FF

    更新日期:2007-08-01 00:00:00

  • Effects of protocol and obesity on dose conversion factors in adult body CT.

    abstract:PURPOSE:In computed tomography (CT), organ dose, effective dose, and risk index can be estimated from volume-weighted CT dose index (CTDI(vol)) or dose-length product (DLP) using conversion coefficients. Studies have investigated how these coefficients vary across scanner models, scan parameters, and patient size. Howe...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4754584

    authors: Li X,Samei E,Williams CH,Segars WP,Tward DJ,Miller MI,Ratnanather JT,Paulson EK,Frush DP

    更新日期:2012-11-01 00:00:00

  • Penumbral measurements in water for high-energy x rays.

    abstract::Ionization chambers of varying inside diameter have been used to investigate the penumbral region of 60Co, 6-MV, and 31-MV x-ray beams. Measurements were made in water at varying depths up to 25 cm for a square field of side length 10 cm. The dependence of the penumbral widths on both the inside diameter of the ioniza...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595963

    authors: Dawson DJ,Schroeder NJ,Hoya JD

    更新日期:1986-01-01 00:00:00

  • Astigmatic single photon emission computed tomography imaging with a displaced center of rotation.

    abstract::A filtered backprojection algorithm is developed for single photon emission computed tomography (SPECT) imaging with an astigmatic collimator having a displaced center of rotation. The astigmatic collimator has two perpendicular focal lines, one that is parallel to the axis of rotation of the gamma camera and one that...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598325

    authors: Wang H,Smith MF,Stone CD,Jaszczak RJ

    更新日期:1998-08-01 00:00:00

  • High resolution 2D dose measurement device based on a few long scintillating fibers and tomographic reconstruction.

    abstract:PURPOSE:Patient-specific QA of highly conformal radiotherapy treatments are usually conducted using 2D or 3D dosimetry of the incident dose distribution in a water-equivalent phantom. However, dosimeters typically used for this task usually lack in either spatial resolution or dose accuracy. The purpose of this work is...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4736526

    authors: Goulet M,Archambault L,Beaulieu L,Gingras L

    更新日期:2012-08-01 00:00:00

  • Pretreatment patient-specific IMRT quality assurance: a correlation study between gamma index and patient clinical dose volume histogram.

    abstract:PURPOSE:The aim of this work is to investigate the predictive power of a common conventional intensity modulated radiation therapy (IMRT) quality assurance (QA) performance metric, the gamma passing rate (%GP), through the analysis of the sensitivity and of the correlation between %GP and different dose discrepancies b...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4767763

    authors: Stasi M,Bresciani S,Miranti A,Maggio A,Sapino V,Gabriele P

    更新日期:2012-12-01 00:00:00

  • Noncoplanar VMAT for nasopharyngeal tumors: Plan quality versus treatment time.

    abstract:PURPOSE:The authors investigated the potential of optimized noncoplanar irradiation trajectories for volumetric modulated arc therapy (VMAT) treatments of nasopharyngeal patients and studied the trade-off between treatment plan quality and delivery time in radiation therapy. METHODS:For three nasopharyngeal patients, ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4914863

    authors: Wild E,Bangert M,Nill S,Oelfke U

    更新日期:2015-05-01 00:00:00

  • Impact of transverse magnetic fields on dose response of a radiophotoluminescent glass dosimeter in megavoltage photon beams.

    abstract:PURPOSE:The purpose of this study was to investigate the impact of transverse magnetic fields on the dose response of a radiophotoluminescent glass dosimeter (RGD) in megavoltage photon beams. METHODS:The RGD relative response (i.e., RGD dose per absorbed dose to water at the midpoint of the detector in the absence of...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14054

    authors: Ito S,Araki F,Ohno T

    更新日期:2020-04-01 00:00:00

  • Multipinhole collimator with 20 apertures for a brain SPECT application.

    abstract:PURPOSE:Several new technologies for single photon emission computed tomography (SPECT) instrumentation with parallel-hole collimation have been proposed to improve detector sensitivity and signal collection efficiency. Benefits from improved signal efficiency include shorter acquisition times and lower dose requiremen...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4897567

    authors: Lee TC,Ellin JR,Huang Q,Shrestha U,Gullberg GT,Seo Y

    更新日期:2014-11-01 00:00:00

  • Pharmacokinetic modeling.

    abstract::For radiation dosimetry calculations of radiolabeled monoclonal antibodies, (MAB), pharmacokinetics are critical. Specifically, pharmacokinetic modeling is a useful component of estimation of cumulated activity in various source organs in the body. It is thus important to formulate general methods of pharmacokinetic m...

    journal_title:Medical physics

    pub_type: 杂志文章,评审

    doi:10.1118/1.597047

    authors: Strand SE,Zanzonico P,Johnson TK

    更新日期:1993-03-01 00:00:00

  • Vision 20/20: Magnetic resonance imaging-guided attenuation correction in PET/MRI: Challenges, solutions, and opportunities.

    abstract::Attenuation correction is an essential component of the long chain of data correction techniques required to achieve the full potential of quantitative positron emission tomography (PET) imaging. The development of combined PET/magnetic resonance imaging (MRI) systems mandated the widespread interest in developing nov...

    journal_title:Medical physics

    pub_type: 杂志文章,评审

    doi:10.1118/1.4941014

    authors: Mehranian A,Arabi H,Zaidi H

    更新日期:2016-03-01 00:00:00

  • Use of CEA TVS film for measuring high energy photon beam dose distributions.

    abstract::CEA TVS film is a therapy verification film that has been recently introduced in the North American market. This film features linear characteristic curves for photon energies from 137Cs to 18 MV as reported by Cheng and Das [Med. Phys. 23, 1225 (1996)]. In Saskatoon, TVS film was investigated for its application in t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598316

    authors: Cadman P

    更新日期:1998-08-01 00:00:00

  • Computerized detection of masses in digital mammograms: automated alignment of breast images and its effect on bilateral-subtraction technique.

    abstract::An automated technique for the alignment of right and left breast images has been developed for use in the computerized analysis of bilateral breast images. In this technique, the breast region is first identified in each digital mammogram by use of histogram analysis and morphological filtering operations. The anteri...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597307

    authors: Yin FF,Giger ML,Doi K,Vyborny CJ,Schmidt RA

    更新日期:1994-03-01 00:00:00

  • Automation of routine elements for spot-scanning proton patient-specific quality assurance.

    abstract:PURPOSE:At our institution, all proton patient plans undergo patient-specific quality assurance (PSQA) prior to treatment delivery. For intensity-modulated proton beam therapy, quality assurance is complex and time consuming, and it may involve multiple measurements per field. We reviewed our PSQA workflow and identifi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13246

    authors: Hernandez Morales D,Shan J,Liu W,Augustine KE,Bues M,Davis MJ,Fatyga M,Johnson JE,Mundy DW,Shen J,Younkin JE,Stoker JB

    更新日期:2019-01-01 00:00:00

  • Tumor volume measurement errors of RECIST studied with ellipsoids.

    abstract:PURPOSE:The authors investigate the extent to which Response Evaluation Criteria in Solid Tumors (RECIST) can predict tumor volumes in ideal geometric settings and using clinical data. METHODS:The authors consider a hierarchy of models including uniaxial ellipsoids, general ellipsoids, and composites of ellipsoids, us...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3577602

    authors: Levine ZH,Galloway BR,Peskin AP,Heussel CP,Chen JJ

    更新日期:2011-05-01 00:00:00

  • Noise, sampling, and the number of projections in cone-beam CT with a flat-panel detector.

    abstract:PURPOSE:To investigate the effect of the number of projection views on image noise in cone-beam CT (CBCT) with a flat-panel detector. METHODS:This fairly fundamental consideration in CBCT system design and operation was addressed experimentally (using a phantom presenting a uniform medium as well as statistically moti...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4875688

    authors: Zhao Z,Gang GJ,Siewerdsen JH

    更新日期:2014-06-01 00:00:00

  • In vivo cancer diagnosis with optical spectroscopy and acoustically induced blood stasis using a murine MCa35 model.

    abstract::Ultrasound-induced blood stasis has been observed for more than 30 years. Most of the literature has been focused on the health risks associated with this phenomenon and methods employed to prevent stasis from occurring during ultrasound imaging. To date, experimental observations have been either in vitro or invasive...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2198196

    authors: Winey BA,Misic V,Liao L,Parker K,Fenton BM,Yu Y

    更新日期:2006-06-01 00:00:00