Efficient generation of a magnetic field-free line.

Abstract:

PURPOSE:Signal encoding in magnetic particle imaging (MPI) is achieved by moving a field-free point (FFP) through the region of interest. One way to increase the sensitivity of the method is to scan the region of interest with a field-free line (FFL) instead of the FFP. Recently, the first feasible FFL coil setup was introduced. The purpose of this article is to improve the efficiency of the FFL coil geometry even further. METHODS:In order to reduce the electrical power loss of the setup, an additional Maxwell coil pair is introduced that is tailored to generate the static part of the FFL field. RESULTS:Using the proposed coil assembly, the electrical power loss for the generation of a rotating FFL is considerably reduced compared to previously known coil setups. Furthermore, the quality of the generated FFL is significantly increased. CONCLUSIONS:The proposed coil assembly is almost as efficient as an equivalent FFP scanner. Furthermore, the assembly cannot only be used for FFL imaging but for FFP imaging as well. Hence, the findings of this article denote an important step toward the first practical implementation of the FFL coil geometry.

journal_name

Med Phys

journal_title

Medical physics

authors

Knopp T,Erbe M,Biederer S,Sattel TF,Buzug TM

doi

10.1118/1.3447726

subject

Has Abstract

pub_date

2010-07-01 00:00:00

pages

3538-40

issue

7

eissn

0094-2405

issn

2473-4209

journal_volume

37

pub_type

信件
  • Effects on image quality of a 2D antiscatter grid in x-ray digital breast tomosynthesis: Initial experience using the dual modality (x-ray and molecular) breast tomosynthesis scanner.

    abstract:PURPOSE:Radiation scattered from the breast in digital breast tomosynthesis (DBT) causes image degradation, including loss of contrast between cancerous and background tissue. Unlike in 2-dimensional (2D) mammography, an antiscatter grid cannot readily be used in DBT because changing alignment between the tube and dete...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4943632

    authors: Patel T,Peppard H,Williams MB

    更新日期:2016-04-01 00:00:00

  • Delivery validation of an automated modulated electron radiotherapy plan.

    abstract:PURPOSE:Modulated electron radiation therapy (MERT) represents an active area of interest that offers the potential to improve healthy tissue sparing in treatment of certain cancer cases. Challenges remain however in accurate beamlet dose calculation, plan optimization, collimation method, and delivery accuracy. In thi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4876297

    authors: Connell T,Alexander A,Papaconstadopoulos P,Serban M,Devic S,Seuntjens J

    更新日期:2014-06-01 00:00:00

  • Electron dosimetry based on the absorbed dose to water concept: a comparison of the AAPM TG-51 and DIN 6800-2 protocols.

    abstract::The dosimetry protocols DIN 6800-2 and AAPM TG-51, both based on the absorbed dose to water concept, are compared in their theoretical background and in their application to electron dosimetry. The agreement and disagreement in correction factors and energy parameters used in both protocols will be shown and discussed...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1414008

    authors: Dohm OS,Christ G,Nüsslin F,Schüle E,Bruggmoser G

    更新日期:2001-11-01 00:00:00

  • Peak SNR in automated coronary calcium scoring: selecting CT scan parameters and statistically defined scoring thresholds.

    abstract:PURPOSE:Development and verification of peak signal-to-noise ratio (SNR(P)) equations for determining optimum CT scanning and scoring parameters for a new automated coronary calcium scoring program (N-vivo). Experimental evaluation of the new program for scoring small calcium hydroxyapatite (CaHA) microspheres with sma...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3442276

    authors: Arnold BA,Xiang P,Mao SS,Budoff MJ

    更新日期:2010-07-01 00:00:00

  • Quantitation of SPECT performance: Report of Task Group 4, Nuclear Medicine Committee.

    abstract::A comprehensive performance testing program is an essential ingredient of high-quality single-photon emission computed tomography (SPECT). Many of the procedures previously published are complicated, time consuming, or require a special testing environment. This Task Group developed a protocol for evaluating SPECT ima...

    journal_title:Medical physics

    pub_type: 指南,杂志文章

    doi:10.1118/1.597605

    authors: Graham LS,Fahey FH,Madsen MT,van Aswegen A,Yester MV

    更新日期:1995-04-01 00:00:00

  • On the use of C-arm fluoroscopy for treatment planning in high dose rate brachytherapy.

    abstract::Treatment planning for brachytherapy requires the acquisition of geometrical information of the implant applicator and the patient anatomy. This is typically done using a simulator or a computed tomography scanner. In this study, we present a different method by which orthogonal images from a C-arm fluoroscopic machin...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1598851

    authors: Liu L,Bassano DA,Prasad SC,Keshler BL,Hahn SS

    更新日期:2003-09-01 00:00:00

  • Novel scintillation detector design and performance for proton radiography and computed tomography.

    abstract:PURPOSE:Proton computed tomography (pCT) will enable accurate prediction of proton and ion range in a patient while providing the benefit of lower radiation exposure than in x-ray CT. The accuracy of the range prediction is essential for treatment planning in proton or ion therapy and depends upon the detector used to ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4939255

    authors: Bashkirov VA,Schulte RW,Hurley RF,Johnson RP,Sadrozinski HF,Zatserklyaniy A,Plautz T,Giacometti V

    更新日期:2016-02-01 00:00:00

  • Calculation of x-ray spectra emerging from an x-ray tube. Part II. X-ray production and filtration in x-ray targets.

    abstract::A new approach to the calculation of the x-ray spectrum emerging from an x-ray tube is proposed. Theoretical results for the bremsstrahlung cross section appearing in the literature are summarized. Four different treatments of electron penetration, based on the work presented in Part I, are then used to generate brems...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2734726

    authors: Poludniowski GG

    更新日期:2007-06-01 00:00:00

  • Transverse tomosynthesis on a digital simulator.

    abstract::The availability of digital radiographic imaging on simulators has led to the investigation of a number of new imaging possibilities, including digital linear tomography (tomosynthesis). It has been shown that a single set of projections in this case is sufficient to reconstruct images from multiple planes, including ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598006

    authors: Zwicker RD,Atari NA

    更新日期:1997-06-01 00:00:00

  • Comparative dosimetry of diode and diamond detectors in electron beams for intraoperative radiation therapy.

    abstract::The aim of the present study is to examine the validity of using silicon semiconductor detectors in degraded electron beams with a broad energy spectrum and a wide angular distribution. A comparison is made with diamond detector measurements, which is the dosimeter considered to give the best results provided that dos...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1315317

    authors: Björk P,Knöös T,Nilsson P

    更新日期:2000-11-01 00:00:00

  • Differences in the lesion formation process between focused ultrasound and microwave ablations.

    abstract::The objective is to understand the differences in the lesion formation processes between microwave and high-intensity focused ultrasound (HIFU) ablation. The lesions formed by microwaves and HIFU were real-time monitored and compared using transparent tissue-mimicking phantoms at 60 and 70 W of driving electrical powe...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2193689

    authors: Chen WS,Wu CC,Fang HY,Liu HL

    更新日期:2006-05-01 00:00:00

  • Technical Note: On maximizing Cherenkov emissions from medical linear accelerators.

    abstract:PURPOSE:Cherenkov light during MV radiotherapy has recently found imaging and therapeutic applications but is challenged by relatively low fluence. Our purpose is to investigate the feasibility of increasing Cherenkov light production during MV radiotherapy by increasing photon energy and applying specialized beam-hard...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12927

    authors: Shrock Z,Yoon SW,Gunasingha R,Oldham M,Adamson J

    更新日期:2018-07-01 00:00:00

  • Characterization of difference of Gaussian filters in the detection of mammographic regions.

    abstract::In this article, we present a characterization of the effect of difference of Gaussians (DoG) filters in the detection of mammographic regions. DoG filters have been used previously in mammographic mass computer-aided detection (CAD) systems. As DoG filters are constructed from the subtraction of two bivariate Gaussia...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2358326

    authors: Catarious DM Jr,Baydush AH,Floyd CE Jr

    更新日期:2006-11-01 00:00:00

  • Calculation of 131I-ortho-iodohippurate absorbed kidney dose: a literature review.

    abstract::Extensive information has been made available relative to the physical aspects necessary for calculation of radiation absorbed dose from radiopharmaceuticals. A similar data base for the biological factors involved in these calculations has not been documented as thoroughly. The authors present an extensive literature...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594679

    authors: Flannery A,Veber J,Greenfield MA,McIntyre AB,Hamilton DR

    更新日期:1980-05-01 00:00:00

  • Active energy selective image detector for dual-energy computed radiography.

    abstract::A new energy selective detector for dual energy computed radiography has been developed that combines many of the advantages of x-ray tube voltage switching and single exposure double screen detectors. The new active detector utilizes electro-optical modulation of the response of the storage phosphor screens to allow ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597831

    authors: Alvarez RE

    更新日期:1996-10-01 00:00:00

  • Traceable micro-CT scaling accuracy phantom for applications requiring exact measurement of distances or volumes.

    abstract:PURPOSE:Volumetric x-ray microcomputed tomography (CT) can be employed in a variety of quantitative research applications such as image-guided interventions or characterization of medical devices. To ensure the highest geometric fidelity of images for these applications, a phantom and image processing algorithm have be...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4752083

    authors: Waring CS,Bax JS,Samarabandu A,Holdsworth DW,Fenster A,Lacefield JC

    更新日期:2012-10-01 00:00:00

  • Image resolution of a microchannel plate x-ray image intensifier.

    abstract::The resolution has been evaluated for an experimental x-ray image intensifier employing three microchannel plates (MCPs) as the photon absorber and electron multipliers. The line spread function (LSF) was measured and used for determination of the modulation transfer function (MTF). The MTF was found to be independent...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594463

    authors: Gould RG

    更新日期:1978-01-01 00:00:00

  • Stereomammography: evaluation of depth perception using a virtual 3D cursor.

    abstract::We are evaluating the usefulness of stereomammography in improving breast cancer diagnosis. One area that we are investigating is whether the improved depth perception associated with stereomammography might be significantly enhanced with the use of a virtual 3D cursor. A study was performed to evaluate the accuracy o...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.599008

    authors: Goodsitt MM,Chan HP,Hadjiiski L

    更新日期:2000-06-01 00:00:00

  • SU-E-T-504: Incident Fluence Reconstruction Based on Monte Carlo Finite-Size Pencil Beam Model for Dose Guided Radiation Therapy.

    abstract:PURPOSE:In dose guided radiation therapy, incident fluence is one of the important parameters for both influence verification and dose reconstruction. The objective of this investigation was to develop a method to obtain the incident fluence for dose reconstruction in dose guided radiation therapy (DGRT). METHODS:An i...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735593

    authors: Li G,Wu Y,FDS Team.

    更新日期:2012-06-01 00:00:00

  • Characteristic image quality of a third generation dual-source MDCT scanner: Noise, resolution, and detectability.

    abstract:PURPOSE:The purpose of this work was to assess the inherent image quality characteristics of a new multidetector computed tomography system in terms of noise, resolution, and detectability index as a function of image acquisition and reconstruction for a range of clinically relevant settings. METHODS:A multisized imag...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4923172

    authors: Solomon J,Wilson J,Samei E

    更新日期:2015-08-01 00:00:00

  • SU-E-T-404: A Prototype Program for Analyzing 4D Image Guidance Shifts for Lung SBRT.

    abstract:PURPOSE:A prototype in-house program was developed to assist deriving image guidance shifts clinically using our 4DCT method for lung SBRT. METHODS:Our in-house prototype program was implemented in MATLAB. The 4D DICOM CT dataset of interest is imported by the program from AW and subsequently accepts input from the us...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735493

    authors: Wang B,Sarkar V,Busselberg C,Rassiah-Szegedi P,Zhao H,Huang Y,Szegedi M,Salter B

    更新日期:2012-06-01 00:00:00

  • Sampling methods for a matrix ionization chamber system.

    abstract::To achieve increased image acquisition speed or better image quality, several read-out methods for a matrix ionization chamber system have been investigated. In this device, which is applied for portal imaging in radiation therapy, 256 x 256 small liquid-filled ionization chambers are scanned by switching the polarizi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596829

    authors: van Herk M,Bijhold J,Hoogervorst B,Meertens H

    更新日期:1992-03-01 00:00:00

  • Patient doses and projection angle in cone beam CT.

    abstract:PURPOSE:To investigate how x-ray tube projection angle affects organ and effective doses to patients undergoing a CT examination on a cone beam scanner. METHODS:The authors investigated two cone beam CT systems that use a flat panel detector to capture the x-ray pattern transmitted through patients. One system had the...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3397458

    authors: He W,Huda W,Magill D,Tavrides E,Yao H

    更新日期:2010-05-01 00:00:00

  • Measurement of surface dose in an MR-Linac with optically stimulated luminescence dosimeters for IMRT beam geometries.

    abstract:PURPOSE:This study aims to measure the surface dose on an anthropomorphic phantom for intensity-modulated radiation therapy (IMRT) plans treated in a 1.5 T magnetic resonance (MR)-Linac. Previous studies have used Monte Carlo programs to simulate surface dose and have recognized high surface dose as a potential limitin...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14185

    authors: Lim-Reinders S,Keller BM,Sahgal A,Chugh B,Kim A

    更新日期:2020-07-01 00:00:00

  • Reconstruction of electron spectra from depth doses with adaptive regularization.

    abstract::Electron spectral reconstruction of medical accelerators from measured depth doses is a practical method for providing the input initial phase space distribution at the patient surface that is required by Monte Carlo treatment planning systems. The posed inverse problem of spectral reconstruction is ill conditioned an...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2161404

    authors: Wei J,Sandison GA,Chvetsov AV

    更新日期:2006-02-01 00:00:00

  • Measurement of transit time of a remote after-loading high dose rate brachytherapy source.

    abstract::Quantification of transit time of a remote after-loading high dose rate (HDR) brachytherapy source is important both for accurate treatment planning and for quality assurance checks. In this investigation, an HDR-1000 well ionization chamber and a precision electrometer are used to measure the transit time of the Ir-1...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1386779

    authors: Sahoo N

    更新日期:2001-08-01 00:00:00

  • Fully automatic deformable registration of pretreatment MRI/CT for image-guided prostate radiotherapy planning.

    abstract:PURPOSE:In prostate radiotherapy, dose distribution may be calculated on CT images, while the MRI can be used to enhance soft tissue visualization. Therefore, a registration between MR and CT images could improve the overall treatment planning process, by improving visualization with a demonstrated interobserver deline...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12629

    authors: Hamdan I,Bert J,Rest CCL,Tasu JP,Boussion N,Valeri A,Dardenne G,Visvikis D

    更新日期:2017-12-01 00:00:00

  • Monte Carlo study of ionization chamber magnetic field correction factors as a function of angle and beam quality.

    abstract:PURPOSE:To use EGSnrc Monte Carlo simulations for magnetic field dosimetry to determine optimal measurement orientations, calculate beam quality conversion factors for 32 cylindrical and three parallel-plate (PP) ion chambers, evaluate the beam quality and angular dependence of these factors, and examine the magnetic f...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12716

    authors: Malkov VN,Rogers DWO

    更新日期:2018-02-01 00:00:00

  • Controlled mold geometry for surgical deficit treatment planning.

    abstract::The relatively precise placement of brachytherapy sources afforded by stereotactic frames for brain implants is not generally achievable for other sites, which lack the fixed geometry of the cranium and its contents. An exception is a source-containing rigid mold that delivers brachytherapy when inserted securely in a...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597454

    authors: Anderson LL,Zlotolow IM,McCormick B,Harrison LB

    更新日期:1995-03-01 00:00:00

  • Higher energy: is it necessary, is it worth the cost for radiation oncology?

    abstract::The physical characteristics of the interactions of megavoltage photons and electrons with matter provide distinct advantages, relative to low-energy (orthovoltage) x rays, that lead to better radiation dose distributions in patients. Use of these high-energy radiations has resulted in better patient care, which has b...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596779

    authors: Das IJ,Kase KR

    更新日期:1992-07-01 00:00:00