PURPOSE:This study aims to measure the surface dose on an anthropomorphic phantom for intensity-modulated radiation therapy (IMRT) plans treated in a 1.5 T magnetic resonance (MR)-Linac. Previous studies have used Monte Carlo programs to simulate surface dose and have recognized high surface dose as a potential limiting factor for the MR-Linac; however, to our knowledge surface dose measurement for clinical plans has not yet been published. Given the novelty of the MR-Linac, it is important to perform in vivo measurements of a potentially dose-limiting factor such as surface dose when moving forward for clinical use. METHODS:Optically stimulated luminescence dosimeters (OSLDs) were used on an anthropomorphic phantom. Intensity-modulated radiation therapy plans were generated to treat a near-surface breast tumor in the phantom. The tumor was treated with 2, 3, 5, 7, and 9 beam IMRT plans with a 1.5 T MR-Linac using a 7-MV photon beam. The plans were generated in a Monte Carlo treatment planning system (TPS) capable of modeling magnetic field effects. The surface dose was sampled in seven locations on the surface surrounding the planning target volume (PTV), and in two different OSLD configurations with the dosimeters measuring water equivalent depths of 0.16 and 0.64 mm. The TPS was used to estimate the doses at the OSLD locations. In addition, MR images were taken of a pork belly with and without an OSLD placed anteriorly placed to determine the effect of an OSLD on image fidelity. RESULTS:For the 3, 5, 7, and 9-beam configurations, surface doses were approximately half that of the prescription dose to the simulated tumor, although the magnitude of the skin dose relative to the prescription is certainly also dependent on individual patient anatomy. The general trend for both TPS and measurements was that the greater the number of beams, the lower the skin doses and dose readings; also, with increasing numbers of beams, doses at shallow depths become lower relative to deeper depths. The MR images showed that the presence of the OSLD did not induce clinically relevant geometric distortions or intensity differences. CONCLUSIONS:To our knowledge, this study is the first of its kind to experimentally measure the surface dose in an MR-Linac for IMRT plans. This study has explored the use of OSLDs to measure in vivo surface dose in a clinical setting. OSLDs may be used to measure skin dose clinically when there are concerns of skin radiation burns and near-surface toxicity. Optically stimulated luminescence dosimeters are promising devices for in vivo surface dosimetry in an MR-Linac.
journal_name
Med Physjournal_title
Medical physicsauthors
Lim-Reinders S,Keller BM,Sahgal A,Chugh B,Kim Adoi
10.1002/mp.14185subject
Has Abstractpub_date
2020-07-01 00:00:00pages
3133-3142issue
7eissn
0094-2405issn
2473-4209journal_volume
47pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract:PURPOSE:Using a new linear accelerator with high dose rate (800 MU/min), fast MLC motions (5.0 cm/s), fast gantry rotation (15 s/rotation), and 1 cm wide MLCs, we aimed to quantify the effects of complexity, arc number, and fractionation on interplay for breast and lung treatments under target motion. METHODS:To study...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12899
更新日期:2018-06-01 00:00:00
abstract:PURPOSE:The hematopoietically active tissues of skeletal bone marrow are a prime target for computational dosimetry given potential risks of leukemia and, at higher dose levels, acute marrow toxicity. The complex three-dimensional geometry of trabecular spongiosa, however, complicates schema for dose assessment in such...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12002
更新日期:2017-01-01 00:00:00
abstract:PURPOSE:This study investigated the dosimetry performance of a linear fiber-optic coupled dosimeter with a sensitive element varying from 3 to 15 cm in length. The dosimeter is comprised of a tissue equivalent plastic scintillating fiber coupled to a photomultiplier tube (PMT). The sensitive element has a length repres...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4734756
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:Motion compensated positron emission tomography (PET) imaging requires detecting and monitoring of patient body motion. We developed a semiautomatic list-mode method to track the three-dimensional (3D) motion of fiducial positron-emitting markers during PET imaging. METHODS:A previously developed motion tracki...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14206
更新日期:2020-08-01 00:00:00
abstract::A method to determine the bone mineral density of the calcaneum has been reported earlier by our laboratory. In this method, the calcaneum is irradiated by a 60-keV photon beam from 241Am source and both the coherent and Compton scattered photons are detected by a high-purity Ge detector. The bone mineral density is d...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595669
更新日期:1985-07-01 00:00:00
abstract:PURPOSE:For accurate tissue inhomogeneity correction in radiotherapy treatment planning, the authors had previously proposed a novel conversion of the energy-subtracted CT number to an electron density (ΔHU-ρe conversion), which provides a single linear relationship between ΔHU and ρe over a wide ρe range. The purpose ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4881327
更新日期:2014-07-01 00:00:00
abstract::Proton beams offer several advantages over conventional radiation techniques for treating cancer and other diseases. These advantages might be negated if the leakage and scatter radiation from the beamline and patient are too large. Although the leakage and scatter radiation for the double scattering proton beamlines ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2805086
更新日期:2008-01-01 00:00:00
abstract:PURPOSE:To compare optimization characteristics, plan quality, and treatment delivery efficiency between total marrow irradiation (TMI) plans using the new TomoTherapy graphic processing unit (GPU) based dose engine and CPU/cluster based dose engine. METHODS:Five TMI plans created on an anthropomorphic phantom were op...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4810936
更新日期:2013-07-01 00:00:00
abstract:PURPOSE:To evaluate the replacement of Cerrobend by copper for electron beam cutouts. METHODS:The dosimetric comparisons for circular copper-and Cerrobend-cutouts with diameters (1.0, 2.0, 3.0, 5.0, 7.5, 10.0, and 12.5 cm) were made using electron beams with energies (6, 9, 12, 16, and 20 MeV) from 3 Varian accelerato...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735336
更新日期:2012-06-01 00:00:00
abstract::The paper presents a theoretical derivation of the photon fluence simulation efficiency in photon beam treatment head simulations without and with bremsstrahlung splitting. The expressions obtained provide a rigorous explanation of the efficiency dependence on scoring zone size and splitting number and explain the lar...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1943808
更新日期:2005-07-01 00:00:00
abstract:PURPOSE:In fluoroscopy-guided clinical procedures that involve tracking objects over long treatment times, there is a need for reducing the amount of imaging dose delivered to the patient and the operating staff. In this study, we introduce a feedback metric to minimize tube current while maintaining a targeting precis...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4734878
更新日期:2012-06-01 00:00:00
abstract::Optimal visualization of moving structures such as the heart and coronary arteries using digital radiographic imaging systems is a difficult problem that can involve tradeoffs between temporal, spatial, and density resolution. The motion dependence of four angiographic measures of vessel dimensions is given and demons...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595651
更新日期:1985-11-01 00:00:00
abstract::The most favorable treatment for moving body anatomy should aim at utilizing organ motion to minimize the dose to sensitive structures without compromising the dose delivered to the target. The solution of the problem of appropriate intensity redistribution over different phases of body motion is achievable in dynamic...
journal_title:Medical physics
pub_type: 信件
doi:10.1118/1.2804722
更新日期:2007-12-01 00:00:00
abstract:PURPOSE:To investigate how the setting of optimization parameters, fractional dose and tuning structure in tomotherapy treatment planning affects plan dosimetric quality and treatment efficiency. METHODS:A digital phantom to simulate head and neck radiotherapy was constructed for this study. Tumor was 10cm long C-shap...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735724
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:The most common metric for comparing measured to calculated dose, such as for pretreatment quality assurance of intensity-modulated photon fields, is a pass rate (%) generated using percent difference (%Diff), distance-to-agreement (DTA), or some combination of the two (e.g., gamma evaluation). For many dosimet...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3651695
更新日期:2011-11-01 00:00:00
abstract:PURPOSE:This paper describes the clinical implementation and medical commissioning of the MedAustron Particle Therapy Accelerator (MAPTA) for non-isocentric scanned proton beam treatments. METHODS:Medical physics involvement during technical commissioning work is presented. Acceptance testing procedures, including adv...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13928
更新日期:2020-02-01 00:00:00
abstract:PURPOSE:Stereotactic ablative body radiotherapy (SABR) for lung patients can be performed with volumetric-modulated arc therapy (VMAT) plans using off-axis target geometry to allow treatment in their CBCT verified position. For patient-specific quality assurance measurements using the PTW Octavius 4D phantom (PTW, Frei...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12805
更新日期:2018-04-01 00:00:00
abstract::This paper deals with methods of reducing the total time required to acquire the projection data for a set of contiguous computed tomography (CT) images. Normally during the acquisition of a set of slices, the patient is held stationary during data collection and translated to the next axial location during an intersc...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596464
更新日期:1990-11-01 00:00:00
abstract:PURPOSE:The purpose of this work was to examine the suitability of VIPARnd polymer gel-9.4 T magnetic resonance microimaging system for high spatial resolution dose distribution measurements. METHODS:The VIPARnd samples (3 cm in outside diameter and 12 cm in height) were exposed to ionizing radiation by using a linear...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14186
更新日期:2020-08-01 00:00:00
abstract:PURPOSE:To evaluate the energy dependence of Gafchromic EBT3 film for establishing a quality assurance method of bolus electron conformal radiotherapy. METHODS:We irradiated electron beam to EBT3 films, which were set in the water tank. The linear accelerator used was Varian Clinac 21EX. The energy of electron beams w...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735200
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:To compare the estimate of normalized glandular dose in mammography and breast CT imaging obtained using the actual glandular tissue distribution in the breast to that obtained using the homogeneous tissue mixture approximation. METHODS:Twenty volumetric images of patient breasts were acquired with a dedicated...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4737025
更新日期:2012-08-01 00:00:00
abstract::We present a theoretical development and experimental verification of a description of power loss and sample resistance for a lossy sample in a nuclear magnetic resonance radio frequency coil for a sample geometry where the eddy current streamlines are disrupted from their usually assumed circular paths. Specifically ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596336
更新日期:1989-09-01 00:00:00
abstract:PURPOSE:Radiopharmaceutical applications in nuclear medicine require a detailed dosimetry estimate of the radiation energy delivered to the human tissues. Over the past years, several publications addressed the problem of internal dose estimate in volumes of several sizes considering photon and electron sources. Most o...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3242304
更新日期:2009-11-01 00:00:00
abstract::A proton dose computational algorithm, performing an analytical superposition of infinitely narrow proton beamlets (ASPB) is introduced. The algorithm uses the standard pencil beam technique of laterally distributing the central axis broad beam doses according to the Moliere scattering theory extended to slablike vary...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2064887
更新日期:2005-12-01 00:00:00
abstract:PURPOSE:Intensity-modulated proton therapy (IMPT) is known to be sensitive to patient setup and range uncertainty issues. Multiple robust optimization methods have been developed to mitigate the impact of these uncertainties. Here, we propose a new robust optimization method, which provides an alternative way of robust...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13276
更新日期:2019-01-01 00:00:00
abstract::Techniques have been developed for reducing motion blurring artifacts by using respiratory gated computed tomography (CT) in sinogram space and quantitatively evaluating the artifact reduction. A synthetic sinogram was built from multiple scans intercepting a respiratory gating window. A gated CT image was then recons...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2074187
更新日期:2005-11-01 00:00:00
abstract::Transthoracic electrical impedance Z consists of a constant baseline component Z0 and the time variable component delta Z such that Z = Z0 + delta Z. The first time derivative of Z has a negative peak, the magnitude of which is (dZ/dt)min. Measurements of 170 volunteers show that (dZ/dt)min is a function of the consta...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594910
更新日期:1981-01-01 00:00:00
abstract::Contemporary reconstruction methods employed for clinical helical cone-beam computed tomography (CT) are analytical (noniterative) but mathematically nonexact, i.e., the reconstructed image contains so called cone-beam artifacts, especially for higher cone angles. Besides cone artifacts, these methods also suffer from...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2966353
更新日期:2008-09-01 00:00:00
abstract::To develop volumetric micro-CT fluoroscopy for small animal imaging, we have proposed a cone-beam system with multiple x-ray sources. In this paper, we extend Parker's single-source half-scan weighting scheme to the case of an odd number of x-ray sources that are equiangularly distributed, and apply it for half-scan F...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1381549
更新日期:2001-07-01 00:00:00
abstract:PURPOSE:Very fast Monte Carlo (MC) simulations of proton transport have been implemented recently on graphics processing units (GPUs). However, these MCs usually use simplified models for nonelastic proton-nucleus interactions. Our primary goal is to build a GPU-based proton transport MC with detailed modeling of elast...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4921046
更新日期:2015-06-01 00:00:00