Electron dosimetry based on the absorbed dose to water concept: a comparison of the AAPM TG-51 and DIN 6800-2 protocols.

Abstract:

:The dosimetry protocols DIN 6800-2 and AAPM TG-51, both based on the absorbed dose to water concept, are compared in their theoretical background and in their application to electron dosimetry. The agreement and disagreement in correction factors and energy parameters used in both protocols will be shown and discussed. Measurements with three different types of ionization chambers were performed and evaluated according to both protocols. As a result the perturbation correction factor P(60Co)wall for the Roos chamber was determined to 1.024 +/- 0.5%.

journal_name

Med Phys

journal_title

Medical physics

authors

Dohm OS,Christ G,Nüsslin F,Schüle E,Bruggmoser G

doi

10.1118/1.1414008

subject

Has Abstract

pub_date

2001-11-01 00:00:00

pages

2258-64

issue

11

eissn

0094-2405

issn

2473-4209

journal_volume

28

pub_type

杂志文章
  • Photon attenuation in computed tomography.

    abstract::The analysis and understanding of results of computed tomography (CT) require an understanding of photon attenuation in matter. The high sensitivity and resolution of these devices coupled with the use of a polychromatic photon source require a level and breadth of understanding about photon attenuation not usually re...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594199

    authors: McCullough EC

    更新日期:1975-11-01 00:00:00

  • First study of on-treatment volumetric imaging during respiratory gated VMAT.

    abstract:PURPOSE:To obtain on-treatment volumetric patient anatomy during respiratory gated volumetric modulated arc therapy (VMAT). METHODS:On-board imaging device integrated with Linacs offers a viable tool for obtaining patient anatomy during radiation treatment delivery. In this study, the authors acquired beam-level kV im...

    journal_title:Medical physics

    pub_type: 信件

    doi:10.1118/1.4794925

    authors: Choi K,Xing L,Koong A,Li R

    更新日期:2013-04-01 00:00:00

  • Analysis of generalized rosette trajectory for compressed sensing MRI.

    abstract:PURPOSE:The application of compressed sensing (CS) technology in magnetic resonance imaging (MRI) is to accelerate the MRI scan speed by incoherent undersampling of k-space data and nonlinear iterative reconstruction of MRI images. This paper generalizes the existing rosette trajectories to configure the sampling patte...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4928152

    authors: Li Y,Yang R,Zhang C,Zhang J,Jia S,Zhou Z

    更新日期:2015-09-01 00:00:00

  • A practical technique for verification of three-dimensional conformal dose distributions in stereotactic radiosurgery.

    abstract::The trend toward conformal techniques in stereotactic radiosurgery necessitates an accurate and practical method for verification of irregular three-dimensional dose distributions. This work presents the design and evaluation of a phantom system facilitating the measurement of conformal dose distributions using one or...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598962

    authors: Robar JL,Clark BG

    更新日期:2000-05-01 00:00:00

  • Predicting target vessel location on robot-assisted coronary artery bypass graft using CT to ultrasound registration.

    abstract:PURPOSE:Although robot-assisted coronary artery bypass grafting (RA-CABG) has gained more acceptance worldwide, its success still depends on the surgeon's experience and expertise, and the conversion rate to full sternotomy is in the order of 15%-25%. One of the reasons for conversion is poor pre-operative planning, wh...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3684958

    authors: Cho DS,Linte C,Chen EC,Bainbridge D,Wedlake C,Moore J,Barron J,Patel R,Peters T

    更新日期:2012-03-01 00:00:00

  • Fluid-filled dynamic bowtie filter: Description and comparison with other modulators.

    abstract:PURPOSE:A dynamic bowtie filter can modulate flux along both fan and view angles for reduced patient dose, scatter, and required photon flux, which is especially important for photon counting detectors (PCDs). Among the proposed dynamic bowtie designs, the piecewise-linear attenuator (Hsieh and Pelc, Med Phys. 2013;40:...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13272

    authors: Shunhavanich P,Hsieh SS,Pelc NJ

    更新日期:2019-01-01 00:00:00

  • Pulmonary embolism in pregnant patients: Assessing organ dose to pregnant phantom and its fetus during lung imaging.

    abstract:PURPOSE:The purpose of this study was to provide updated radiation dose from diagnostic exams performed for pregnant patients suspected of pulmonary embolism (PE) using the recently developed BREP phantoms of pregnant woman and the fetus. Also to challenge the validity of current recommendations suggest that ventilatio...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12558

    authors: Rafat Motavalli L,Hoseinian Azghadi E,Miri Hakimabad H,Akhlaghi P

    更新日期:2017-11-01 00:00:00

  • Toward a statistically relevant calibration end point for prostate seed implants.

    abstract::Interstitial brachytherapy for carcinoma of the prostate is achieved through the use of a configuration of radioactive seeds placed in a manner that delivers a customized, reasonably uniform dose to the target volume. Accurate dose delivery depends on both precise seed placement and reliable seed strength in the impla...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598877

    authors: Rosenzweig DP,Schell MC,Yu Y

    更新日期:2000-01-01 00:00:00

  • Quantitative single-particle digital autoradiography with α-particle emitters for targeted radionuclide therapy using the iQID camera.

    abstract:PURPOSE:Alpha-emitting radionuclides exhibit a potential advantage for cancer treatments because they release large amounts of ionizing energy over a few cell diameters (50-80 μm), causing localized, irreparable double-strand DNA breaks that lead to cell death. Radioimmunotherapy (RIT) approaches using monoclonal antib...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4921997

    authors: Miller BW,Frost SH,Frayo SL,Kenoyer AL,Santos E,Jones JC,Green DJ,Hamlin DK,Wilbur DS,Fisher DR,Orozco JJ,Press OW,Pagel JM,Sandmaier BM

    更新日期:2015-07-01 00:00:00

  • Performance tests of two portable mini gamma cameras for medical applications.

    abstract::We have developed two prototypes of portable gamma cameras for medical applications based on a previous prototype designed and tested by our group. These cameras use a CsI(Na) continuous scintillation crystal coupled to the new flat-panel-type multianode position-sensitive photomultiplier tube, H8500 from Hamamatsu Ph...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2358199

    authors: Sánchez F,Fernández MM,Giménez M,Benlloch JM,Rodríguez-Alvarez MJ,García de Quirós F,Lerche Ch,Pavón N,Palazón JA,Martínez J,Sebastiá A

    更新日期:2006-11-01 00:00:00

  • Calibrated breast density methods for full field digital mammography: a system for serial quality control and inter-system generalization.

    abstract:PURPOSE:The authors are developing a system for calibrated breast density measurements using full field digital mammography (FFDM). Breast tissue equivalent (BTE) phantom images are used to establish baseline (BL) calibration curves at time zero. For a given FFDM unit, the full BL dataset is comprised of approximately ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4903299

    authors: Lu B,Smallwood AM,Sellers TA,Drukteinis JS,Heine JJ,Fowler EE

    更新日期:2015-02-01 00:00:00

  • SU-E-J-11: Characterization of Interfractioanal Anatomical Variations in Post-Operative Radiation Therapy for Prostate Bed.

    abstract:PURPOSE:To quantitatively characterize the interfractional anatomic variations in post-operative radiation therapy (RT) for prostate bed, so that appropriate strategy that can fully address these variations can be developed. METHODS:A total of 102 daily pre-treatment CT acquired using an in-room CT (CTVision, Siemens)...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734844

    authors: Liu F,Ahunbay E,Christian R,Lawton C,Wang D,Li X

    更新日期:2012-06-01 00:00:00

  • Comparison of p-type commercial electron diodes for in vivo dosimetry.

    abstract::This paper compares the characteristics of three types of commercial p-type electron diodes specially designed for in vivo dosimetry (Scanditronix EDD2, Sun Nuclear QED 111200-0 and PTW T60010E diodes coupled with a Therados DPD510 dosimeter) in electron fields with energies from 4.5 to 21 MeV, and in conditions simil...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1630492

    authors: Marre D,Marinello G

    更新日期:2004-01-01 00:00:00

  • The alanine detector in BNCT dosimetry: dose response in thermal and epithermal neutron fields.

    abstract:PURPOSE:The response of alanine solid state dosimeters to ionizing radiation strongly depends on particle type and energy. Due to nuclear interactions, neutron fields usually also consist of secondary particles such as photons and protons of diverse energies. Various experiments have been carried out in three different...

    journal_title:Medical physics

    pub_type: 杂志文章,多中心研究

    doi:10.1118/1.4901299

    authors: Schmitz T,Bassler N,Blaickner M,Ziegner M,Hsiao MC,Liu YH,Koivunoro H,Auterinen I,Serén T,Kotiluoto P,Palmans H,Sharpe P,Langguth P,Hampel G

    更新日期:2015-01-01 00:00:00

  • Effects of tumor motion in GRID therapy.

    abstract::Clinical and biological evidence suggest that the success of GRID therapy in debulking large tumors depends on the high peak-to-valley contrast in the dose distribution. In this study, we show that the peaks and valleys can be significantly blurred out by respiration-induced tumor motion, possibly affecting the clinic...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2977538

    authors: Naqvi SA,Mohiuddin MM,Ha JK,Regine WF

    更新日期:2008-10-01 00:00:00

  • Evaluation of CT-based lean-body SUV.

    abstract:PURPOSE:The authors introduce a novel method for defining standardized uptake values (SUVs) in PET∕CT based on routinely collected CT data. The goal of the study is to reduce, if possible, the variability of SUV in a heterogeneous population. Two well established methods for defining SUV are based on body weight (BW) a...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4816656

    authors: Hamill JJ,Sunderland JJ,LeBlanc AK,Kojima CJ,Wall J,Martin EB

    更新日期:2013-09-01 00:00:00

  • Absolute depth-dose-rate measurements for an 192Ir HDR brachytherapy source in water using MOSFET detectors.

    abstract::Reported MOSFET measurements concern mostly external radiotherapy and in vivo dosimetry. In this paper, we apply the technique for absolute dosimetry in the context of HDR brachytherapy using an 192Ir source. Measured radial dose rate distributions in water for different planes perpendicular to the source axis are pre...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2198168

    authors: Zilio VO,Joneja OP,Popowski Y,Rosenfeld A,Chawla R

    更新日期:2006-06-01 00:00:00

  • Use of a constrained hierarchical optimization dataset enhances knowledge-based planning as a quality assurance tool for prostate bed irradiation.

    abstract:PURPOSE:To investigate whether building a knowledge-based planning (KBP) model with prostate bed plans constructed from constrained hierarchical optimization (CHO) would result in more efficient model construction with more consistent output than a model built using plans from a traditional, trial-and-error-based optim...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13163

    authors: Lin YH,Hong LX,Hunt MA,Berry SL

    更新日期:2018-10-01 00:00:00

  • Characterization of fragmented heavy-ion beams using a three-stage telescope detector: measurements of 670-MeV/amu 20Ne beams.

    abstract::Measurements of a 670-MeV/amu 20Ne beam at the Lawrence Berkeley Laboratory Bevalac heavy-ion accelerator with various thicknesses of water absorber were obtained with the BERKLET. The BERKLET, a simple three-stage solid-state telescope detector, has been described previously. This instrument measures the linear energ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596536

    authors: Llacer J,Schmidt JB,Tobias CA

    更新日期:1990-03-01 00:00:00

  • SU-E-T-236: Brachytherapy for Breast Cancer Patients with Implanted Pacemeker, Using Multi Lumen Partial Breast Applicator.

    abstract:PURPOSE:Discuss optimised Accelerated Partial Breast Irradiation (APBI) using a Strut-Adjused Volume Implant (SAVI) applicator for patients with implanted pacemeker, without overdosing or relocating the pacemaker. METHODS:A right breast cancer patient with an in situ pacemaker (Medtronic model ADDR01) on the right sid...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735299

    authors: Jacob D,Strasser J

    更新日期:2012-06-01 00:00:00

  • Modification and benchmarking of MCNP for low-energy tungsten spectra.

    abstract::The MCNP Monte Carlo radiation transport code was modified for diagnostic medical physics applications. In particular, the modified code was thoroughly benchmarked for the production of polychromatic tungsten x-ray spectra in the 30-150 kV range. Validating the modified code for coupled electron-photon transport with ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1288397

    authors: Mercier JR,Kopp DT,McDavid WD,Dove SB,Lancaster JL,Tucker DM

    更新日期:2000-12-01 00:00:00

  • Task-based assessment of breast tomosynthesis: effect of acquisition parameters and quantum noise.

    abstract:PURPOSE:Tomosynthesis is a promising modality for breast imaging. The appearance of the tomosynthesis reconstructed image is greatly affected by the choice of acquisition and reconstruction parameters. The purpose of this study was to investigate the limitations of tomosynthesis breast imaging due to scan parameters an...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3357288

    authors: Reiser I,Nishikawa RM

    更新日期:2010-04-01 00:00:00

  • Computerized analysis of mammographic microcalcifications in morphological and texture feature spaces.

    abstract::We are developing computerized feature extraction and classification methods to analyze malignant and benign microcalcifications on digitized mammograms. Morphological features that described the size, contrast, and shape of microcalcifications and their variations within a cluster were designed to characterize microc...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598389

    authors: Chan HP,Sahiner B,Lam KL,Petrick N,Helvie MA,Goodsitt MM,Adler DD

    更新日期:1998-10-01 00:00:00

  • A thermoregulated enclosure for controlling thermal drift in a radiation calorimeter.

    abstract::The ability to control thermal drifts is essential in operating a calorimeter. We investigated a thermal enclosure, which envelops the calorimeter with temperature-regulated air, thus thermally isolating the calorimeter from the room. The desired temperature in the enclosure is controlled by a control circuit and a th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595760

    authors: Kubo H,Brown DE,Russell MD

    更新日期:1985-05-01 00:00:00

  • A statistical analysis of ionometrically measured 6-MV x-ray beam parameters.

    abstract::A statistical analysis has been made of ionometrically measured parameters related to the central-axis output, the beam symmetry, the beam flatness, and the depth dose for the 6-MV x-ray beam from the Therac-6 linear accelerator. The means and coefficients of variation of the measurements are determined on a monthly b...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595642

    authors: Dawson DJ,Gribble MA

    更新日期:1984-09-01 00:00:00

  • Rotationally resliced 3D prostate TRUS segmentation using convex optimization with shape priors.

    abstract:PURPOSE:Efficient and accurate segmentations of 3D end-firing transrectal ultrasound (TRUS) images play an important role in planning of 3D TRUS guided prostate biopsy. However, poor image quality of the input 3D TRUS images, such as strong imaging artifacts and speckles, often makes it a challenging task to extract th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4906129

    authors: Qiu W,Yuan J,Ukwatta E,Fenster A

    更新日期:2015-02-01 00:00:00

  • 2-Step IMAT and 2-Step IMRT: a geometrical approach.

    abstract::The purpose of this paper is to develop a method that reduces the number of segments for intensity modulated arc therapy (IMAT) and intensity modulated radiotherapy (IMRT) for concave target volumes (TV). The aim was to utilize no more than two intensity levels per organ at risk (OAR) and to derive both optimal segmen...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1861161

    authors: Bratengeier K

    更新日期:2005-03-01 00:00:00

  • Automation of routine elements for spot-scanning proton patient-specific quality assurance.

    abstract:PURPOSE:At our institution, all proton patient plans undergo patient-specific quality assurance (PSQA) prior to treatment delivery. For intensity-modulated proton beam therapy, quality assurance is complex and time consuming, and it may involve multiple measurements per field. We reviewed our PSQA workflow and identifi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13246

    authors: Hernandez Morales D,Shan J,Liu W,Augustine KE,Bues M,Davis MJ,Fatyga M,Johnson JE,Mundy DW,Shen J,Younkin JE,Stoker JB

    更新日期:2019-01-01 00:00:00

  • A new approach to CT pixel-based photon dose calculations in heterogeneous media.

    abstract::The effects of small cavities on dose in water and the dose in a homogeneous nonunit density medium illustrate that inhomogeneities do not act independently in photon dose perturbation, and serve as two constraints which should be satisfied by approximate methods of computed tomography (CT) pixel-based dose calculatio...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595294

    authors: Wong JW,Henkelman RM

    更新日期:1983-03-01 00:00:00

  • Dosimetric effects of needle divergence in prostate seed implant using 125I and 103Pd radioactive seeds.

    abstract::In prostate seed implants, radioactive seeds are implanted into the prostate through a guiding needle with the help of a template and real-time imaging. The ideal locations of the guiding needles and the relative positions of the seeds in each needle are determined before the implantation under the assumption that the...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598971

    authors: Nath S,Chen Z,Yue N,Trumpore S,Peschel R

    更新日期:2000-05-01 00:00:00