Abstract:
:Interstitial brachytherapy for carcinoma of the prostate is achieved through the use of a configuration of radioactive seeds placed in a manner that delivers a customized, reasonably uniform dose to the target volume. Accurate dose delivery depends on both precise seed placement and reliable seed strength in the implanted configuration. This study assumes the independence of the two issues, and quantifies the reduction in the minimum dose to the surface of the gland due only to variability in individual seed strengths. Current AAPM guidelines pertaining to the acceptable limits on seed-to-seed variability are prudent for small configurations of seeds, yet are likely to be overly stringent for applications such as prostate seed implantation. In this study we determine the reduction in the minimum peripheral dose (mPD) caused by the introduction of source strength variability, and provide statistical insight into this effect. It is concluded that the current guidelines limit the reduction in mPD to < or =0.4% relative to the prescription value, for an average configuration, due to the inclusion of strength variability. The maximum observed reduction in mPD would be < or =1.5%. This value is an order of magnitude lower than the recommendations of the AAPM Task Group 40 for the overall accuracy of brachytherapy procedures, which suggests that seed strength variability is of limited concern and that constraints on this factor should perhaps be reevaluated.
journal_name
Med Physjournal_title
Medical physicsauthors
Rosenzweig DP,Schell MC,Yu Ydoi
10.1118/1.598877subject
Has Abstractpub_date
2000-01-01 00:00:00pages
144-50issue
1eissn
0094-2405issn
2473-4209journal_volume
27pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract::The verification of dose distributions with high dose gradients as appearing in brachytherapy or stereotactic radiotherapy for example, calls for dosimetric methods with sufficiently high spatial resolution. Polymer gels in combination with a MR or optical scanner as a readout device have the potential of performing t...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2898173
更新日期:2008-05-01 00:00:00
abstract:PURPOSE:Intraventricular hemorrhage (IVH) is a major cause of brain injury in preterm neonates. Three dimensional ultrasound (US) imaging systems have been developed to visualize 3D anatomical structure of preterm neonatal intracranial ventricular system with IVH and ventricular dilation. To allow quantitative analysis...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4932366
更新日期:2015-11-01 00:00:00
abstract:PURPOSE:The efficiency of radioembolization procedures could be greatly enhanced if results of the 99m Tc-MAA pretreatment procedure were immediately available in the interventional suite, enabling 1-day procedures as a result of direct estimation of the hepatic radiation dose and lung shunt fraction. This would, howev...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13253
更新日期:2019-01-01 00:00:00
abstract:PURPOSE:Radiotherapy, especially with charged particles, is sensitive to executional and preparational uncertainties that propagate to uncertainty in dose and plan quality indicators, for example, dose-volume histograms (DVHs). Current approaches to quantify and mitigate such uncertainties rely on explicitly computed e...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14414
更新日期:2020-10-01 00:00:00
abstract:UNLABELLED:The following question is investigated: How narrow do the leaves of a multileaf collimator have to be such that further reduction of the leaf width does not lead to physical improvements of the dose distribution. Because of the physical principles of interaction between radiation and matter, dose distributio...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1319524
更新日期:2000-11-01 00:00:00
abstract:PURPOSE:To develop a new design of an x-ray beam shaper for helical computed tomography (CT) that increases the dose utilization. METHODS:For typical reconstruction algorithms in helical CT, different data are utilized with different weights during back-projection. In particular, data of the outer detector rows, i.e.,...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3577766
更新日期:2011-07-01 00:00:00
abstract:PURPOSE:Variations during breast tissue development can influence later breast cancer risk. In particular, prolonged nulliparity increases risk. The authors used optical spectroscopy to compare breast tissue in 115 nulliparous women aged 31-40 (group 2) to 140 nulliparous women aged 18-21 (group 1), and also to 36 paro...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3276737
更新日期:2010-02-01 00:00:00
abstract:PURPOSE:The authors previously introduced a methodology to generate a realistic three-dimensional (3D), high-resolution, computer-simulated breast phantom based on empirical data. One of the key components of such a phantom is that it provides a means to produce a realistic simulation of clinical breast compression. In...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3637500
更新日期:2011-10-01 00:00:00
abstract:PURPOSE:Normal patient databases (NPDs) are used to distinguish between normal and abnormal perfusion in SPECT myocardial perfusion imaging (MPI) and have gained wide acceptance in the clinical environment, yet there are limitations to this approach. This study introduces a template-based method for semi-quantitative M...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3595112
更新日期:2011-07-01 00:00:00
abstract:PURPOSE:To characterize a new air vented ionization chamber technology, suitable to build detector arrays with small pixel pitch and independence of sensitivity on dose per pulse. METHODS:The prototype under test is a linear array of air vented ionization chambers, consisting of 80 pixels with 3.5 mm pixel pitch dista...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4945414
更新日期:2016-05-01 00:00:00
abstract:PURPOSE:The objective of this study is to evaluate requirements for radionuclide-based solid tumor therapy by assessing the radial dose distribution of beta-particle-emitting and alpha-particle-emitting molecules localized either solely within endothelial cells of tumor vasculature or diffusing from the vasculature thr...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3431999
更新日期:2010-06-01 00:00:00
abstract:PURPOSE:Wide bore CT scanners use extended field-of-view (eFOV) reconstruction algorithms to attempt to recreate tissue truncated due to large patient habitus. Radiation therapy planning systems rely on accurate CT numbers in order to correctly plan and calculate radiation dose. This study looks at the impact of eFOV r...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13299
更新日期:2019-02-01 00:00:00
abstract:PURPOSE:Imaging the knee under realistic load-bearing conditions can be carried out in a horizontal plane using a C-arm CT scanner. Human subjects can be scanned in a standing position and acquired data successfully reconstructed. However, reconstructing this data is a challenge due to significant artifacts that are in...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4736213
更新日期:2012-06-01 00:00:00
abstract::We adapted a small sodium iodide scintillation detector for rapid, in vivo localization of a lost brachytherapy seed. Using the detector, we were able to locate and remove an Ir-192 seed that was not visible to the unaided eye. ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595528
更新日期:1984-07-01 00:00:00
abstract::Interchange or transfer of radiographic techniques through measurement of penetration quality is discussed. The usefulness of this achievement is verified using an aluminum step wedge. Also, the procedure described provides a method for performance evaluation of kVp compensation on diagnostic x-ray installations. ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594156
更新日期:1975-01-01 00:00:00
abstract::This paper proposes a new respiratory gated radiation treatment system that allows real-time tumor localization while avoiding invasive operation to a patient. The proposed system employs a three-dimensional (3D) ultrasound device, a 3D digital localizer, and a real-time image processing system. At the planning time, ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1634482
更新日期:2004-02-01 00:00:00
abstract:PURPOSE:The use of 4D computed tomography (4D-CT) of the lung is important in lung cancer radiotherapy for tumor localization and treatment planning. Sometimes, dense sampling is not acquired along the superior-inferior direction. This disadvantage results in an interslice thickness that is much greater than in-plane v...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4899185
更新日期:2014-11-01 00:00:00
abstract:PURPOSE:To achieve more translatable preclinical research results, small animal irradiation needs to more closely simulate human radiotherapy. Although the clinical gold standard is intensity-modulated radiation therapy (IMRT), the direct translation of this method for small animals is impractical. In this study we des...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13872
更新日期:2019-12-01 00:00:00
abstract::The relative sensitivity of the half-value layer (HVL) method as a quality index for megavoltage x-ray beams is examined by theoretical calculation and experimental measurements for 4-, 6-, 10-, and 25-MV x-ray beams. It is shown that lower atomic number materials are more sensitive to beam quality changes than higher...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595794
更新日期:1985-01-01 00:00:00
abstract::Performance characteristics sufficient to provide physical data base specific to the Siemen's Stabilipan 2 orthovoltage x-ray therapy machine are presented. Operating conditions covering the working range of the unit from 100 to 300 kVp are selected. Beam quality, output, the central axis depth dose, relative output f...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596016
更新日期:1987-09-01 00:00:00
abstract:PURPOSE:Radiopharmaceutical applications in nuclear medicine require a detailed dosimetry estimate of the radiation energy delivered to the human tissues. Over the past years, several publications addressed the problem of internal dose estimate in volumes of several sizes considering photon and electron sources. Most o...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3242304
更新日期:2009-11-01 00:00:00
abstract:PURPOSE:The GammaPod is a novel dedicated prone breast stereotactic radiosurgery (SRS) device recently developed at the University of Maryland Medical Center. This device utilizes multiple rotating Co-60 sources to create highly conformal dose distributions for breast treatments, including boosts, partial breast irradi...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14197
更新日期:2020-08-01 00:00:00
abstract::The objective of this study was to compare the contrast-detail performance of five different commercial liquid crystal displays (LCDs) to other LCD and cathode-ray tube (CRT) displays for medical applications. A contrast-detail phantom, supplemented with 5 in. of acrylic, was imaged on a commercial digital radiographi...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2868780
更新日期:2008-04-01 00:00:00
abstract::Traditionally, short scan helical FDK algorithms have been implemented based on horizontal transaxial slices. However, not every point on the horizontal transaxial slice satisfies Tuy's condition for the corresponding (pi+fan angle) segment of helix, which means that some points on the horizontal slices are incomplete...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1916077
更新日期:2005-06-01 00:00:00
abstract::This article is the first in a series on the calculation of electron dose using multiple-scattering theory. In it we develop a unified theory, which we term Gaussian multiple-scattering theory, starting from a number of contributions already in the literature: the Fermi-Eyges multiple-scattering theory, the Yang path ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596166
更新日期:1988-03-01 00:00:00
abstract:PURPOSE:Current respiratory motion monitoring devices used for motion synchronization in medical imaging and radiotherapy provide either 1D respiratory signal over a specific region or 3D information based on few external or internal markers. On the other hand, newer technology may offer the potential to monitor the en...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3589131
更新日期:2011-06-01 00:00:00
abstract:PURPOSE:To study the relationships between dose (D), kerma (K), and collision kerma ( K col ) in photon beams and to investigate total radiative yields for electrons and positrons as a functio...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13744
更新日期:2019-11-01 00:00:00
abstract::A new variety of tissue-mimicking materials for use in 1H nuclear magnetic resonance (NMR) phantoms has been developed and extensively tested, principally at 10 MHz and at room temperature. The materials can be formed with a broad range of T1's and T2's representative of soft tissues. They are mixtures of various perc...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596219
更新日期:1988-07-01 00:00:00
abstract:PURPOSE:To determine the accuracy and reproducibility of the automatic- setup procedure of a 3D water scanner (3D SCANNER, Sun Nuclear Corp). The procedure automatically aligns the scanner's coordinate system to the Linac coordinate system. A unique off-center detector holder extends the scan range to 630 mm, eliminati...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4734668
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:By means of Monte Carlo (MC) simulations and indirect measurements, we have evaluated the maximum dose rates achievable with conventional x-ray tubes and related them to FLASH therapy dose rates of >40 Gy/s. METHODS:Monte Carlo models of two 160 kV x-ray tubes, the 3-kW MXR-160/22 and the 6-kW MXR-165, were bu...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13858
更新日期:2019-12-01 00:00:00