Effects on image quality of a 2D antiscatter grid in x-ray digital breast tomosynthesis: Initial experience using the dual modality (x-ray and molecular) breast tomosynthesis scanner.

Abstract:

PURPOSE:Radiation scattered from the breast in digital breast tomosynthesis (DBT) causes image degradation, including loss of contrast between cancerous and background tissue. Unlike in 2-dimensional (2D) mammography, an antiscatter grid cannot readily be used in DBT because changing alignment between the tube and detector during the scan would result in unacceptable loss of primary radiation. However, in the dual modality breast tomosynthesis (DMT) scanner, which combines DBT and molecular breast tomosynthesis, the tube and detector rotate around a common axis, thereby maintaining a fixed tube-detector alignment. This C-arm geometry raises the possibility of using a 2D (cellular) focused antiscatter grid. The purpose of this study is to assess change in image quality when using an antiscatter grid in the DBT portion of a DMT scan under conditions of fixed radiation dose. METHODS:Two 2D focused prototype grids with 80 cm focal length were tested, one stack-laminated from copper (Cu) and one cast from a tungsten-polymer (W-poly). They were reciprocated using a motion scheme designed to maximize transmission of primary x-ray photons. Grid-in and grid-out scatter-to-primary ratios (SPRs) were measured for rectangular blocks of material simulating 30%, 50%, and 70% glandular tissue compositions. For assessment of changes in image quality through the addition of a grid, the Computerized Imaging Reference Systems, Inc., phantom Model 011A containing a set of 1 cm thick blocks simulating a range of glandular/adipose ratios from 0/100 to 100/0 was used. To simulate 6.5 and 8.5 cm thick compressed breasts, 1 cm thick slices of PMMA were added to the Model 011A phantom. DBT images were obtained with and without the grid, with exposure parameters fixed for a given compressed thickness. Signal-difference-to-noise ratios (SDNRs), contrast, and voxel value-based attenuation coefficients (μ) were measured for all blocks from reconstructed phantom images. RESULTS:For 4, 6, and 8 cm tissue-equivalent block phantom thicknesses, the inclusion of the W-poly grid reduced the SPR by factors of 5, 6, and 5.8, respectively. For the same thicknesses, the copper grid reduced the SPR by factors of 3.9, 4.5, and 4.9. For the 011A phantom, the W-poly grid raised the SDNR of the 70/30 block from 0.8, -0.32, and -0.72 to 0.9, 0.76, and 0.062 for the 4.5, 6.5, and 8.5 cm phantoms, respectively. It raised the SDNR of the 100/0 block from 3.78, 1.95, and 1.0 to 3.79, 3.67, and 3.25 for the 4.5, 6.5, and 8.5 cm phantoms, respectively. Inclusion of the W-poly grid improved the accuracy of image-based μ values for all block compositions. However, smearing of attenuation across slices due to limited angular sampling decreases the sensitivity of voxel values to changing composition compared to theoretical μ values. CONCLUSIONS:Under conditions of fixed radiation dose to the breast, use of a 2D focused grid increased contrast, SDNR, and accuracy of estimated attenuation for mass-simulating block compositions in all phantom thicknesses tested, with the degree of improvement depending upon material composition. A 2D antiscatter grid can be usefully incorporated in DBT systems that employ fully isocentric tube-detector rotation.

journal_name

Med Phys

journal_title

Medical physics

authors

Patel T,Peppard H,Williams MB

doi

10.1118/1.4943632

subject

Has Abstract

pub_date

2016-04-01 00:00:00

pages

1720

issue

4

eissn

0094-2405

issn

2473-4209

journal_volume

43

pub_type

杂志文章
  • Diamond detector versus silicon diode and ion chamber in photon beams of different energy and field size.

    abstract::The aim of this work was to test the suitability of a PTW diamond detector for nonreference condition dosimetry in photon beams of different energy (6 and 25 MV) and field size (from 2.6 cm x 2.6 cm to 10 cm x 10 cm). Diamond behavior was compared to that of a Scanditronix p-type silicon diode and a Scanditronix RK io...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1591431

    authors: Bucciolini M,Buonamici FB,Mazzocchi S,De Angelis C,Onori S,Cirrone GA

    更新日期:2003-08-01 00:00:00

  • Determination of the reference air kerma rate for 192Ir brachytherapy sources and the related uncertainty.

    abstract::Different methods exist to determine the air kerma calibration factor of an ionization chamber for the spectrum of a 192Ir high-dose-rate (HDR) or pulsed-dose-rate (PDR) source. An analysis of two methods to obtain such a calibration factor was performed: (i) the method recommended by [Goetsch et al., Med. Phys. 18, 4...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1791352

    authors: van Dijk E,Kolkman-Deurloo IK,Damen PM

    更新日期:2004-10-01 00:00:00

  • SU-E-T-236: Brachytherapy for Breast Cancer Patients with Implanted Pacemeker, Using Multi Lumen Partial Breast Applicator.

    abstract:PURPOSE:Discuss optimised Accelerated Partial Breast Irradiation (APBI) using a Strut-Adjused Volume Implant (SAVI) applicator for patients with implanted pacemeker, without overdosing or relocating the pacemaker. METHODS:A right breast cancer patient with an in situ pacemaker (Medtronic model ADDR01) on the right sid...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735299

    authors: Jacob D,Strasser J

    更新日期:2012-06-01 00:00:00

  • X-ray scatter correction in breast tomosynthesis with a precomputed scatter map library.

    abstract:PURPOSE:To develop and evaluate the impact on lesion conspicuity of a software-based x-ray scatter correction algorithm for digital breast tomosynthesis (DBT) imaging into which a precomputed library of x-ray scatter maps is incorporated. METHODS:A previously developed model of compressed breast shapes undergoing mamm...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4866229

    authors: Feng SS,D'Orsi CJ,Newell MS,Seidel RL,Patel B,Sechopoulos I

    更新日期:2014-03-01 00:00:00

  • Localization of cochlear implant electrodes in radiographs.

    abstract::Multielectrode cochlear implantation is the most effective treatment for profound sensorineural hearing loss. In vivo three-dimensional 3-D localization of cochlear implant electrodes is important for modeling of the electrical field in the cochlea, design of electrode arrays, and may improve speech processor programm...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598940

    authors: Yang S,Wang G,Skinner MW,Rubinstein JT,Vannier MW

    更新日期:2000-04-01 00:00:00

  • Design for an accelerator-based orthogonal epithermal neutron beam for boron neutron capture therapy.

    abstract::This paper is concerned with the proposed Birmingham accelerator-based epithermal neutron beam for boron neutron capture therapy (BNCT). In particular, the option of producing a therapy beam at an orthogonal direction to the incoming protons is considered. Monte Carlo radiation transport simulations, both with and wit...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598479

    authors: Allen DA,Beynon TD,Green S

    更新日期:1999-01-01 00:00:00

  • Image resolution of a microchannel plate x-ray image intensifier.

    abstract::The resolution has been evaluated for an experimental x-ray image intensifier employing three microchannel plates (MCPs) as the photon absorber and electron multipliers. The line spread function (LSF) was measured and used for determination of the modulation transfer function (MTF). The MTF was found to be independent...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594463

    authors: Gould RG

    更新日期:1978-01-01 00:00:00

  • Urinary bladder cancer staging in CT urography using machine learning.

    abstract:PURPOSE:To evaluate the feasibility of using an objective computer-aided system to assess bladder cancer stage in CT Urography (CTU). MATERIALS AND METHODS:A dataset consisting of 84 bladder cancer lesions from 76 CTU cases was used to develop the computerized system for bladder cancer staging based on machine learnin...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12510

    authors: Garapati SS,Hadjiiski L,Cha KH,Chan HP,Caoili EM,Cohan RH,Weizer A,Alva A,Paramagul C,Wei J,Zhou C

    更新日期:2017-11-01 00:00:00

  • SU-E-T-619: A Network-Flow Solution Approach to VMAT Treatment Plan Optimization.

    abstract:PURPOSE:To add mathematical rigor to the merging phase of the recently published two-stage VMAT optimization method called VMERGE. Using an exact merging method, we are able to better characterize the tradeoff between delivery efficiency and dose quality. METHODS:VMERGE begins with an IMRT plan that uses 180 equi-spac...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735709

    authors: Salari E,Craft D

    更新日期:2012-06-01 00:00:00

  • Spectrally resolved bioluminescence tomography using the reciprocity approach.

    abstract::Spectrally resolved bioluminescence optical tomography is an approach to recover images of, for example, Luciferase activity within a volume using multiwavelength emission data from internal bioluminescence sources. The underlying problem of uniqueness associated with nonspectrally resolved intensity-based bioluminesc...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2982138

    authors: Dehghani H,Davis SC,Pogue BW

    更新日期:2008-11-01 00:00:00

  • The role of water desorption on optical clearing of biotissue: studied with near infrared reflectance spectroscopy.

    abstract::In order to understand the role of water desorption, i.e., the opposite of water adsorption, in optical clearing of biological tissue created by the application of hyperosmotic agents, dynamics of water loss in fresh porcine muscle tissue administrated with glycerol or ethylene glycol was investigated with the near-in...

    journal_title:Medical physics

    pub_type:

    doi:10.1118/1.1576228

    authors: Xu X,Wang RK

    更新日期:2003-06-01 00:00:00

  • Development and implementation of EPID-based quality assurance tests for the small animal radiation research platform (SARRP).

    abstract:PURPOSE:Although small animal image-guided radiotherapy (SA-IGRT) systems are used increasingly in preclinical research, tools for performing routine quality assurance (QA) have not been optimized and are not readily available. Robust, efficient, and reliable QA tools are needed to ensure the accuracy and reproducibili...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12939

    authors: Anvari A,Poirier Y,Sawant A

    更新日期:2018-07-01 00:00:00

  • Detecting electron beam energy shifts with a commercially available energy monitor.

    abstract::Routine electron beam quality assurance requires an accurate, yet practical, method of energy characterization. Subtle shifts in beam energy may be produced by the linac bending magnet assembly, and the sensitivity of a commercially available electron beam energy-monitoring device for monitoring these small energy dri...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.599033

    authors: Evans MD,Moftah BA,Olivares M,Podgorsak EB

    更新日期:2000-07-01 00:00:00

  • Comparison of x ray computed tomography number to proton relative linear stopping power conversion functions using a standard phantom.

    abstract:PURPOSE:Adequate evaluation of the results from multi-institutional trials involving light ion beam treatments requires consideration of the planning margins applied to both targets and organs at risk. A major uncertainty that affects the size of these margins is the conversion of x ray computed tomography numbers (XCT...

    journal_title:Medical physics

    pub_type: 杂志文章,多中心研究

    doi:10.1118/1.4870956

    authors: Moyers MF

    更新日期:2014-06-01 00:00:00

  • SU-E-T-231: Comparison of Beam Characteristics of Small Field 6 MeV Electrons as Replacement for Superficial X Ray Beam.

    abstract:PURPOSE:To compare beam characteristics of superficial X-rays with 6 MeV Electrons for the purpose of replacing superficial treatments with electron fields for skin lesions. METHODS:Electron beam cutouts were made with 12mm thickness cerrobend in diameters 2-5 cm to match superficial X-ray machine cones. Central axis ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735294

    authors: Avadhani J,Sasidharan S,Carton C,Lowen M,Klapproth T,Licitra C

    更新日期:2012-06-01 00:00:00

  • Characterization of electron contamination in megavoltage photon beams.

    abstract::The purpose of the present study is to characterize electron contamination in photon beams in different clinical situations. Variations with field size, beam modifier (tray, shaping block) and source-surface distance (SSD) were studied. Percentage depth dose measurements with and without a purging magnet and replacing...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1895793

    authors: Lopez Medina A,Teijeiro A,Garcia J,Esperon J,Terron JA,Ruiz DP,Carrion MC

    更新日期:2005-05-01 00:00:00

  • Improved modeling of multiple scattering in the Voxel Monte Carlo model.

    abstract::The implementation of an improved model for multiple scattering into the-Voxel Monte Carlo (VMC) algorithm for fast electron dose calculation in radiation therapy is presented. The model takes into account path-length corrections (PLC) and lateral displacement in the individual electron steps. The extraction of the sc...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597933

    authors: Kawrakow I

    更新日期:1997-04-01 00:00:00

  • Development and validation of a measurement-based source model for kilovoltage cone-beam CT Monte Carlo dosimetry simulations.

    abstract:PURPOSE:The purpose of this study is to adapt an equivalent source model originally developed for conventional CT Monte Carlo dose quantification to the radiation oncology context and validate its application for evaluating concomitant dose incurred by a kilovoltage (kV) cone-beam CT (CBCT) system integrated into a lin...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4823795

    authors: McMillan K,McNitt-Gray M,Ruan D

    更新日期:2013-11-01 00:00:00

  • Potential use of P-32 ophthalmic applicator: Monte Carlo simulations for design and dosimetry.

    abstract::Postoperative beta-irradiation after pterygium excision has been considered a valuable therapeutic procedure to reduce the recurrence rate. Recently, it was reported that beta-irradiation also substantially reduced the risk of surgical failure after glaucoma surgery. Pure beta-irradiation using a 90Sr/Y applicator has...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2896076

    authors: Park YK,Ye SJ,Kim IH,Wee WR,Kim MK,Han HS,Son KJ,Park UJ

    更新日期:2008-05-01 00:00:00

  • An adaptive probabilistic atlas for anomalous brain segmentation in MR images.

    abstract:PURPOSE:Automated segmentation of brain structures (objects) in MR three-dimensional (3D) images for quantitative analysis has been a challenge and probabilistic atlases (PAs) are among the most well-succeeded approaches. However, the existing models do not adapt to possible object anomalies due to the presence of a di...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13771

    authors: Martins SB,Bragantini J,Falcão AX,Yasuda CL

    更新日期:2019-11-01 00:00:00

  • Dosimetric effect of respiration-gated beam on IMRT delivery.

    abstract::Intensity modulated radiation therapy (IMRT) with a dynamic multileaf collimator (DMLC) requires synchronization of DMLC leaf motion with dose delivery. A delay in DMLC communication is known to cause leaf lag and lead to dosimetric errors. The errors may be exacerbated by gated operation. The purpose of this study wa...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1592017

    authors: Duan J,Shen S,Fiveash JB,Brezovich IA,Popple RA,Pareek PN

    更新日期:2003-08-01 00:00:00

  • FRoG: An independent dose and LETd prediction tool for proton therapy at ProBeam® facilities.

    abstract:PURPOSE:Particle therapy is becoming increasingly available world-wide for precise tumor targeting, its favorable depth dose deposition, and increased biological damage to tumor tissue compared to conventional photon therapy. As demand increases for improved robustness and conformality, next-generation secondary dose c...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14417

    authors: Kopp B,Fuglsang Jensen M,Mein S,Hoffmann L,Nyström H,Falk M,Haberer T,Abdollahi A,Debus J,Mairani A

    更新日期:2020-10-01 00:00:00

  • Automation of routine elements for spot-scanning proton patient-specific quality assurance.

    abstract:PURPOSE:At our institution, all proton patient plans undergo patient-specific quality assurance (PSQA) prior to treatment delivery. For intensity-modulated proton beam therapy, quality assurance is complex and time consuming, and it may involve multiple measurements per field. We reviewed our PSQA workflow and identifi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13246

    authors: Hernandez Morales D,Shan J,Liu W,Augustine KE,Bues M,Davis MJ,Fatyga M,Johnson JE,Mundy DW,Shen J,Younkin JE,Stoker JB

    更新日期:2019-01-01 00:00:00

  • Dosimetric verification of helical tomotherapy for total scalp irradiation.

    abstract::Total scalp irradiation is a treatment technique used for a variety of superficial malignancies. Helical tomotherapy is an effective technique used for total scalp irradiation. Recent published work has shown the TomoTherapy planning system to overestimate the superficial dose. In this study, the superficial doses for...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2996288

    authors: Hardcastle N,Soisson E,Metcalfe P,Rosenfeld AB,Tome WA

    更新日期:2008-11-01 00:00:00

  • Heating patterns of microwave applicators in inhomogeneous arm and thigh phantoms.

    abstract::Heating rate (HR) patterns in cylindrical structures were studied with inhomogeneous limb phantoms. These phantoms, arm and thigh models consisting of fat, bone, and muscle material, were heated with Clini-Therm L, M, and MS applicators at 915 MHz. The thigh model is 18 cm in diameter with 2.65-cm-thick fat on the out...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596627

    authors: Chou CK,McDougall JA,Chan KW,Luk KH

    更新日期:1991-11-01 00:00:00

  • Speckle contrast diffuse correlation tomography of complex turbid medium flow.

    abstract:PURPOSE:Developed herein is a three-dimensional (3D) flow contrast imaging system leveraging advancements in the extension of laser speckle contrast imaging theories to deep tissues along with our recently developed finite-element diffuse correlation tomography (DCT) reconstruction scheme. This technique, termed speckl...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4922206

    authors: Huang C,Irwin D,Lin Y,Shang Y,He L,Kong W,Luo J,Yu G

    更新日期:2015-07-01 00:00:00

  • Technical Note: Correction for intra-chamber dose gradients in reference dosimetry of flattening-filter-free MV photon beams.

    abstract:PURPOSE:To estimate and correct for the volume averaging effect which results from the intra-chamber dose gradients when a Farmer ionization chamber (IC) is used for reference dosimetry in flattening-filter-free (FFF) MV photon beams. METHODS:An intra-chamber dose gradients correction factor (kicdg) to the charge read...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4958960

    authors: Ruggieri R,Naccarato S,Stavrev P,Stavreva N,Pasetto S,Salamone I,Alongi F

    更新日期:2016-08-01 00:00:00

  • An introduction to molecular imaging in radiation oncology: a report by the AAPM Working Group on Molecular Imaging in Radiation Oncology (WGMIR).

    abstract::Molecular imaging is the direct or indirect noninvasive monitoring and recording of the spatial and temporal distribution of in vivo molecular, genetic, and/or cellular processes for biochemical, biological, diagnostic, or therapeutic applications. Molecular images that indicate the presence of malignancy can be acqui...

    journal_title:Medical physics

    pub_type: 杂志文章,评审

    doi:10.1118/1.4819818

    authors: Munley MT,Kagadis GC,McGee KP,Kirov AS,Jang S,Mutic S,Jeraj R,Xing L,Bourland JD

    更新日期:2013-10-01 00:00:00

  • Quantitative cone-beam CT imaging in radiation therapy using planning CT as a prior: first patient studies.

    abstract:PURPOSE:Quantitative cone-beam CT (CBCT) imaging is on increasing demand for high-performance image guided radiation therapy (IGRT). However, the current CBCT has poor image qualities mainly due to scatter contamination. Its current clinical application is therefore limited to patient setup based on only bony structure...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3693050

    authors: Niu T,Al-Basheer A,Zhu L

    更新日期:2012-04-01 00:00:00

  • Film dosimetry analyses on the effect of gold shielding for iodine-125 eye plaque therapy for choroidal melanoma.

    abstract::One of the methods currently being used to treat choroidal melanoma employs an episcleral plaque containing I-125 radioactive seeds. However, comprehensive dosimetry studies on the plaque are scarce and controversial. For this work, we use film to study the dosimetry outside the lip of the gold shield of the eye plaqu...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596556

    authors: Wu A,Krasin F

    更新日期:1990-09-01 00:00:00