Abstract:
:The aim of this work was to test the suitability of a PTW diamond detector for nonreference condition dosimetry in photon beams of different energy (6 and 25 MV) and field size (from 2.6 cm x 2.6 cm to 10 cm x 10 cm). Diamond behavior was compared to that of a Scanditronix p-type silicon diode and a Scanditronix RK ionization chamber. Measurements included output factors (OF). percentage depth doses (PDD) and dose profiles. OFs measured with diamond detector agreed within 1% with those measured with diode and RK chamber. Only at 25 MV, for the smallest field size, RK chamber underestimated OFs due to averaging effects in a pointed shaped beam profile. Agreement was found between PDDs measured with diamond detector and RK chamber for both 6 MV and 25 MV photons and down to 5 cm x 5 cm field size. For the 2.6 cm x 2.6 cm field size, at 25 MV, RK chamber underestimated doses at shallow depth and the difference progressively went to zero in the distal region. PDD curves measured with silicon diode and diamond detector agreed well for the 25 MV beam at all the field sizes. Conversely, the nontissue equivalence of silicon led, for the 6 MV beam, to a slight overestimation of the diode doses in the distal region, at all the field sizes. Penumbra and field width measurements gave values in agreement for all the detectors but with a systematic overestimate by RK measurements. The results obtained confirm that ion chamber is not a suitable detector when high spatial resolution is required. On the other hand, the small differences in the studied parameters, between diamond and silicon systems, do not lead to a significant advantage in the use of diamond detector for routine clinical dosimetry.
journal_name
Med Physjournal_title
Medical physicsauthors
Bucciolini M,Buonamici FB,Mazzocchi S,De Angelis C,Onori S,Cirrone GAdoi
10.1118/1.1591431subject
Has Abstractpub_date
2003-08-01 00:00:00pages
2149-54issue
8eissn
0094-2405issn
2473-4209journal_volume
30pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract::A new factor for shifting isodoes curves for oblique Co-60 photon beams has been deduced. Like the two other known factors, this shift factor depends on the source-to-surface distance (SSD), the depth dose (D) and the derivative of D with depth. A comparison of corrected dose distributions has been made by using the t...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594688
更新日期:1980-05-01 00:00:00
abstract:PURPOSE:Most modern radiotherapy machines are built with a 2D kV imaging system. Combining this imaging system with a 2D-3D inference method would allow for a ready-made option for real-time 3D tumor tracking. This work investigates and compares the accuracy of four existing 2D-3D inference methods using both motion tr...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12765
更新日期:2018-03-01 00:00:00
abstract:PURPOSE:In CT-guided liver tumor ablation interventions, registration of a preoperative contrast-enhanced CT image to the intraoperative CT image is hypothesized to improve guidance. This is a highly challenging registration task due to differences in patient poses and large deformations, and therefore high registratio...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12332
更新日期:2017-07-01 00:00:00
abstract::We applied Monte Carlo methods for the simulation of x-ray scattering in water phantoms. The phantom thickness was varied from 5 to 20 cm, and the monoenergetic incident x rays were varied from 15 to 100 keV. Eight screen pairs and a total absorption system were used as x-ray receptors. We determined the angular, spec...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595771
更新日期:1985-03-01 00:00:00
abstract:PURPOSE:Secondary particles produced in the collision of protons with beam modifiers are of concern in proton therapy. Nevertheless, secondary radiation can provide information on the dosimetric parameters through its dependency on the modulating accessories (range shifter and range modulating wheel). Relatively little...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4765049
更新日期:2012-12-01 00:00:00
abstract::Noise power spectrum (NPS) and detective quantum efficiency (DQE) for metal-plate/film portal detectors are reported for the Co-60 and Linac 10 MV spectra. The detectors consist of a double-emulsion portal film secured between plates of aluminum, copper, brass, or lead. The NPS was found to be independent of the detec...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598437
更新日期:1998-12-01 00:00:00
abstract::Extensive information has been made available relative to the physical aspects necessary for calculation of radiation absorbed dose from radiopharmaceuticals. A similar data base for the biological factors involved in these calculations has not been documented as thoroughly. The authors present an extensive literature...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594679
更新日期:1980-05-01 00:00:00
abstract::Estimated photon energy spectra are derived from transmission measurements using aluminium, copper, and sodium iodide absorbers. Two spectral models are proposed. One is based on a previously published model that analyzes the electron's penetration into the anode, and the production and attenuation of bremsstrahlung p...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598159
更新日期:1997-05-01 00:00:00
abstract::The photon energy spectrum emanating from a Leksell Gamma Knife, Model 23004B, was measured between 0.250 and 3.5 MeV with the sources exposed. Measurements were made using a 2x2 inch NaI detector enclosed in a lead-shielded apparatus having a 1/4 inch diameter measurement aperture, which reduced the amount of radiati...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1355305
更新日期:2001-04-01 00:00:00
abstract::A method for the in vivo determination of the isocenter dose, Diso, and mid-plane dose, Dm, using the transmitted signal St measured by 25 central pixels of an aSi-based EPID is here reported. The method has been applied to check the conformal radiotherapy of pelvic tumors and supplies accurate in vivo dosimetry avoid...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2360014
更新日期:2006-11-01 00:00:00
abstract:PURPOSE:Breast magnetic resonance imaging is highly sensitive but not very specific for the detection of breast cancer. Opportunities exist to supplement the image acquisition with a more specific modality provided the technical challenges of meeting space limitations inside the bore, restricted breast access, and elec...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4820361
更新日期:2013-10-01 00:00:00
abstract:PURPOSE:In current clinical practice, there is no integrated 3D ultrasound (3DUS) guidance system clinically available for breast brachytherapy. In this study, the authors present a novel robot-assisted 3DUS system for real-time planning and guidance of breast interstitial high dose rate (HDR) brachytherapy treatment. ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4934832
更新日期:2015-12-01 00:00:00
abstract:PURPOSE:To describe a method for combining sliding window plans [intensity modulated radiation therapy (IMRT) or volumetric modulated arc therapy (VMAT)] for use in treatment plan averaging, which is needed for Pareto surface navigation based multicriteria treatment planning. METHODS:The authors show that by taking an...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4859295
更新日期:2014-02-01 00:00:00
abstract::The authors present an alternative approach to inverse planning optimization and apply it to volumetric modulated are therapy (VMAT) in one rotation with a prior knowledge about the type of leaf motions. The optimization is based on the projection theorem in inner product spaces. MLC motion is directly considered in t...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3173815
更新日期:2009-08-01 00:00:00
abstract::Lag and residual contrast have been quantified in an amorphous selenium (a-Se) active-matrix flat-panel imager (AMFPI) as a function of frame time, kilovoltage (kV) and megavoltage (MV) x-ray photon energies and amount of radiation incident on the detector. The AMFPI contains a 200 microm thick a-Se layer deposited on...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1713298
更新日期:2004-05-01 00:00:00
abstract::Fluoroscopy is a low dose imaging technique. As such, a very sensitive detector is required to create images of good quality. Present day flat panel active matrix read out systems introduce an amount of noise that inhibits present direct and indirect methods from producing optimal quality images at fluoroscopic exposu...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1513157
更新日期:2002-11-01 00:00:00
abstract:PURPOSE:Recent recommendations of the International Commission on Radiological Protection state that the use of effective dose (E) for assessing patient exposure has severe limitations, though it can be kept for dose comparisons. In cardiology procedures, the equivalent dose (H(T)) is one of the most appropriate dose q...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3561508
更新日期:2011-04-01 00:00:00
abstract::An experiment to determine the peak of the energy spectrum of the photon beam from a Toshiba LMR-15 medical linear accelerator is described. It is found that the flattening filters removed much of the bremsstrahlung spectrum below approximately 1 MeV, resulting in a photon spectrum which peaks around 1.2 MeV. ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595582
更新日期:1984-11-01 00:00:00
abstract:PURPOSE:Respiration-induced intrafraction target motion is a concern in liver cancer radiotherapy, especially in stereotactic body radiotherapy (SBRT), and therefore, verification of its motion is necessary. An effective means to localize the liver cancer is to insert metal fiducial markers to or near the tumor with si...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3544369
更新日期:2011-02-01 00:00:00
abstract:PURPOSE:The quality of a treatment plan for stereotactic body radiotherapy (SBRT) depends on an experience of each treatment planner. Therefore, the treatment plans are subjectively determined by comparison of several treatment plans developed by time consuming iterative manners, while considering the benefit to a tumo...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735950
更新日期:2012-06-01 00:00:00
abstract::A filtered backprojection algorithm is developed for single photon emission computed tomography (SPECT) imaging with an astigmatic collimator having a displaced center of rotation. The astigmatic collimator has two perpendicular focal lines, one that is parallel to the axis of rotation of the gamma camera and one that...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598325
更新日期:1998-08-01 00:00:00
abstract:PURPOSE:An optimized air ventilation system design for a treatment room in Heavy-ion Medical Facility is an important issue in the aspects of nuclear safety because the activated air produced in a treatment room can directly affect the medical staff and the general public in the radiation-free area. METHODS:Optimized ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12914
更新日期:2018-06-01 00:00:00
abstract:PURPOSE:Brachytherapy is a treatment modality which delivers large doses of radiation in a reduced number of visits. Since a small number of large dose-per-fraction is administered in high dose rate brachytherapy, ensuring the right dose is delivered is highly critical. In this work, a scintillation detector is coupled...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13508
更新日期:2019-05-01 00:00:00
abstract:PURPOSE:Since the first publications on intensity modulated radiation therapy (IMRT) in the early 1980s almost all efforts have been focused on fairly time consuming dynamic or segmental multileaf collimation. With narrow fast scanned photon beams, the flexibility and accuracy in beam shaping increases, not least in co...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3615059
更新日期:2011-08-01 00:00:00
abstract::For obliquely incident photon beams, the buildup of dose with depth is markedly different from normally incident beams. However, relatively little data on this topic exists for high-energy photon beams of energy greater than 6 MV. Measurements of dose in the buildup region were made using a plane-parallel ionization c...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596055
更新日期:1987-05-01 00:00:00
abstract:PURPOSE:An original radionuclide calibrator method for activity determination is presented. The method could be used for intercomparison surveys for short half-life radioactive sources used in Nuclear Medicine, such as(99m)Tc or most positron emission tomography radiopharmaceuticals. METHODS:By evaluation of the resul...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4884035
更新日期:2014-07-01 00:00:00
abstract::In a recent paper of Miller et al. (Med. Phys. 43(5), 2141-2152 (2016), the voltage dependence polarity effect of microionization chambers was studied. It was identified that polarity effect arises from the difference in electric potential between the collecting electrode and the guard electrode, which in turn deforms...
journal_title:Medical physics
pub_type: 信件
doi:10.1002/mp.12019
更新日期:2017-03-01 00:00:00
abstract:PURPOSE:In this study, the authors validated a novel respiratory tracking device, the multidimensional respiratory tracking (MDRT) system, that was designed to assist in correcting for respiratory motion in PET/CT images. The authors also investigated a novel PET acquisition technique, smart gating (SG), that enables t...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3523100
更新日期:2011-01-01 00:00:00
abstract:PURPOSE:For stereotactic radiosurgery (SRS), accurate evaluation of dose-volume metrics for small structures is necessary. The purpose of this study was to compare the DVH metric capabilities of five commercially available SRS DVH analysis tools (Eclipse, Elements, Raystation, MIM, and Velocity). METHODS:DICOM RTdose ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14645
更新日期:2020-12-09 00:00:00
abstract:PURPOSE:To validate a delivery quality assurance (DQA) protocol for tomotherapy based on the measurement of the leaf open times (LOTs). In addition, to show the correlation between the mean relative LOT discrepancy and the dose deviation in the planning target volume (PTV). MATERIALS AND METHODS:We used a LOT measurem...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14348
更新日期:2020-09-01 00:00:00