Angular measurement of the cobalt-60 emitted radiation spectrum from a radiosurgery irradiator.

Abstract:

:The photon energy spectrum emanating from a Leksell Gamma Knife, Model 23004B, was measured between 0.250 and 3.5 MeV with the sources exposed. Measurements were made using a 2x2 inch NaI detector enclosed in a lead-shielded apparatus having a 1/4 inch diameter measurement aperture, which reduced the amount of radiation received by the crystal. All measurements were made one meter above the floor within a quadrant toward one side of the Gamma Knife couch. The measured spectra displayed the expected 60Co doublet of photon peaks at energies of 1.17 and 1.33 MeV. These peaks appeared in spectra beginning at approximately 50 degrees, as one proceeds from a point directly lateral to the source enclosure (0 degrees) toward the foot of the couch (90 degrees). The average photon energy of the spectrum shifts to lower values as the doublet decreases in magnitude with increasing angle until almost vanishing at an angle equal to 90 degrees. Inserting a 16 cm diameter plastic sphere phantom, provided with the Gamma Knife, into the radiation beams increases the low energy photon emissions appearing in the spectrum, especially for measurements at the foot of the couch. Implications for the design of shielding a treatment room containing the Gamma Knife, Model B, and estimation of the radiation exposure to personnel during an emergency procedure in the treatment room with the sources exposed are discussed.

journal_name

Med Phys

journal_title

Medical physics

authors

Drzymala RE,Sohn JW,Guo C,Sobotka LG,Purdy JA

doi

10.1118/1.1355305

subject

Has Abstract

pub_date

2001-04-01 00:00:00

pages

620-8

issue

4

eissn

0094-2405

issn

2473-4209

journal_volume

28

pub_type

杂志文章
  • Learning-based automated segmentation of the carotid artery vessel wall in dual-sequence MRI using subdivision surface fitting.

    abstract:PURPOSE:The quantification of vessel wall morphology and plaque burden requires vessel segmentation, which is generally performed by manual delineations. The purpose of our work is to develop and evaluate a new 3D model-based approach for carotid artery wall segmentation from dual-sequence MRI. METHODS:The proposed me...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12476

    authors: Gao S,van 't Klooster R,Kitslaar PH,Coolen BF,van den Berg AM,Smits LP,Shahzad R,Shamonin DP,de Koning PJH,Nederveen AJ,van der Geest RJ

    更新日期:2017-10-01 00:00:00

  • The effect of z overscanning on radiation burden of pediatric patients undergoing head CT with multidetector scanners: a Monte Carlo study.

    abstract::The purpose of this study was to investigate the effect of z overscanning on eye lens dose and effective dose received by pediatric patients undergoing head CT examinations. A pediatric patient study was carried out to obtain the exposure parameters and data regarding the eye lens position with respect to imaged volum...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2207212

    authors: Tzedakis A,Perisinakis K,Raissaki M,Damilakis J

    更新日期:2006-07-01 00:00:00

  • On the development of consensus values of reference dosimetry parameters for interstitial brachytherapy sources.

    abstract::The American Association of Physicists in Medicine recommends that the reference dose-rate distribution, used for treatment planning for low-energy photon brachytherapy sources in routine clinical use, must be based on at least two independent determinations: one using experimentally measured dose rates and one using ...

    journal_title:Medical physics

    pub_type: 指南,杂志文章

    doi:10.1118/1.1690712

    authors: Chan GH,Nath R,Williamson JF,American Association of Physicists in Medicine.

    更新日期:2004-05-01 00:00:00

  • An approximate short scan helical FDK cone beam algorithm based on nutating curved surfaces satisfying the Tuy's condition.

    abstract::Traditionally, short scan helical FDK algorithms have been implemented based on horizontal transaxial slices. However, not every point on the horizontal transaxial slice satisfies Tuy's condition for the corresponding (pi+fan angle) segment of helix, which means that some points on the horizontal slices are incomplete...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1916077

    authors: Hu J,Tam K,Qi J

    更新日期:2005-06-01 00:00:00

  • SU-E-T-213: Development of a Web Wrapper to Facilitate Radiotherapy Research.

    abstract:PURPOSE:Researchers write many computer programs with unique implementations, usually requiring a great amount of effort for other researchers to learn how to install, configure, and use. Some programs require specialized hardware platforms such as GPU workstation or CPU cluster, which may not readily available for man...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735274

    authors: Folkerts M,Graves Y,Gautier Q,Kim G,Jia X,Jiang S

    更新日期:2012-06-01 00:00:00

  • Region-oriented CT image representation for reducing computing time of Monte Carlo simulations.

    abstract:PURPOSE:We propose a new method for efficient particle transportation in voxelized geometry for Monte Carlo simulations. We describe its use for calculating dose distribution in CT images for radiation therapy. MATERIAL AND METHODS:The proposed approach, based on an implicit volume representation named segmented volum...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2884854

    authors: Sarrut D,Guigues L

    更新日期:2008-04-01 00:00:00

  • Rare-earth scatter fractions in chest radiography.

    abstract::A beam stop technique was used to measure the densitometric scatter fractions under three regions of a humanoid chest phantom utilizing LaOBr and Gd2O2S screens. For these receptors, the scatter fractions under the lung and retrocardiac areas were 13%-36% lower than published values for CaWO4. In the mediastinal area,...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597041

    authors: Petrone TJ,Steidley KD

    更新日期:1993-03-01 00:00:00

  • A beam intensity monitor for the Loma Linda cancer therapy proton accelerator.

    abstract::A beam intensity monitor was tested in a 230-MeV proton beam at the Loma Linda Proton Therapy Accelerator during its commissioning at Fermi National Accelerator Laboratory. The intensity monitor was designed to regulate the beam intensity extracted from the proton synchrotron. The proton beam is tunable between 70 and...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596636

    authors: Coutrakon G,Miller D,Kross BJ,Anderson DF,DeLuca P Jr,Siebers J

    更新日期:1991-07-01 00:00:00

  • An externally and internally deformable, programmable lung motion phantom.

    abstract:PURPOSE:Most clinically deployed strategies for respiratory motion management in lung radiotherapy (e.g., gating and tracking) use external markers that serve as surrogates for tumor motion. However, typical lung phantoms used to validate these strategies are based on a rigid exterior and a rigid or a deformable-interi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4918581

    authors: Cheung Y,Sawant A

    更新日期:2015-05-01 00:00:00

  • The relationship between anatomic noise and volumetric breast density for digital mammography.

    abstract:PURPOSE:The appearance of parenchymal∕stromal patterns in mammography have been characterized as having a Wiener power spectrum with an inverse power-law shape described by the exponential parameter, β. The amount of fibroglandular tissue, which can be quantified in terms of volumetric breast density (VBD), influences ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4736422

    authors: Mainprize JG,Tyson AH,Yaffe MJ

    更新日期:2012-08-01 00:00:00

  • The effects of motion on quantitative vessel measurements.

    abstract::Optimal visualization of moving structures such as the heart and coronary arteries using digital radiographic imaging systems is a difficult problem that can involve tradeoffs between temporal, spatial, and density resolution. The motion dependence of four angiographic measures of vessel dimensions is given and demons...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595651

    authors: Parker DL,Clayton PD,Gustafson DE

    更新日期:1985-11-01 00:00:00

  • Combined mixed approach algorithm for in-line phase-contrast x-ray imaging.

    abstract:PURPOSE:In the past decade, phase-contrast imaging (PCI) has been applied to study different kinds of tissues and human body parts, with an increased improvement of the image quality with respect to simple absorption radiography. A technique closely related to PCI is phase-retrieval imaging (PRI). Indeed, PCI is an ima...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3447727

    authors: De Caro L,Scattarella F,Giannini C,Tangaro S,Rigon L,Longo R,Bellotti R

    更新日期:2010-07-01 00:00:00

  • Modification and benchmarking of MCNP for low-energy tungsten spectra.

    abstract::The MCNP Monte Carlo radiation transport code was modified for diagnostic medical physics applications. In particular, the modified code was thoroughly benchmarked for the production of polychromatic tungsten x-ray spectra in the 30-150 kV range. Validating the modified code for coupled electron-photon transport with ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1288397

    authors: Mercier JR,Kopp DT,McDavid WD,Dove SB,Lancaster JL,Tucker DM

    更新日期:2000-12-01 00:00:00

  • Astigmatic single photon emission computed tomography imaging with a displaced center of rotation.

    abstract::A filtered backprojection algorithm is developed for single photon emission computed tomography (SPECT) imaging with an astigmatic collimator having a displaced center of rotation. The astigmatic collimator has two perpendicular focal lines, one that is parallel to the axis of rotation of the gamma camera and one that...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598325

    authors: Wang H,Smith MF,Stone CD,Jaszczak RJ

    更新日期:1998-08-01 00:00:00

  • Validation of a novel robot-assisted 3DUS system for real-time planning and guidance of breast interstitial HDR brachytherapy.

    abstract:PURPOSE:In current clinical practice, there is no integrated 3D ultrasound (3DUS) guidance system clinically available for breast brachytherapy. In this study, the authors present a novel robot-assisted 3DUS system for real-time planning and guidance of breast interstitial high dose rate (HDR) brachytherapy treatment. ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4934832

    authors: Poulin E,Gardi L,Barker K,Montreuil J,Fenster A,Beaulieu L

    更新日期:2015-12-01 00:00:00

  • A dosimetry review system for cooperative group research.

    abstract::The validity of conclusions drawn from multi-institutional radiotherapy studies is dependent upon the degree to which participating hospitals adhere to study requirements. A major effort undertaken by the Quality Assurance Review Center (QARC) assesses whether or not patient data which are deemed evaluable actually co...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595221

    authors: Reinstein LE,McShan D,Glicksman AS

    更新日期:1982-03-01 00:00:00

  • Four-dimensional cone-beam computed tomography and digital tomosynthesis reconstructions using respiratory signals extracted from transcutaneously inserted metal markers for liver SBRT.

    abstract:PURPOSE:Respiration-induced intrafraction target motion is a concern in liver cancer radiotherapy, especially in stereotactic body radiotherapy (SBRT), and therefore, verification of its motion is necessary. An effective means to localize the liver cancer is to insert metal fiducial markers to or near the tumor with si...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3544369

    authors: Park JC,Park SH,Kim JH,Yoon SM,Kim SS,Kim JS,Liu Z,Watkins T,Song WY

    更新日期:2011-02-01 00:00:00

  • Correlation between physical measurements and observer evaluations of image quality in digital chest radiography.

    abstract:PURPOSE:The aim of this paper was to investigate the relationship between the physical and subjective (observer) image quality metrics in digital chest radiography. METHODS:Five digital radiography systems, four with indirect flat panel detector and one with storage phosphor-based computed radiography system, were use...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14244

    authors: Yalcin A,Olgar T,Sancak T,Atac GK,Akyar S

    更新日期:2020-09-01 00:00:00

  • Comment on: Polarity effects and apparent ion recombination in microionization chambers Med. Phys. 43(5), 2141-2152 (2016).

    abstract::In a recent paper of Miller et al. (Med. Phys. 43(5), 2141-2152 (2016), the voltage dependence polarity effect of microionization chambers was studied. It was identified that polarity effect arises from the difference in electric potential between the collecting electrode and the guard electrode, which in turn deforms...

    journal_title:Medical physics

    pub_type: 信件

    doi:10.1002/mp.12019

    authors: Brivio D,Sajo E,Zygmanski P

    更新日期:2017-03-01 00:00:00

  • An innovative digital imaging set-up allowing a low-dose approach to phase contrast applications in the medical field.

    abstract::Recently, new imaging modalities based on the detection of weak phase perturbations effects, among which are phase contrast and diffraction imaging, have been developed by several researchers. Due to their high sensitivity to weakly absorbing details, these techniques seem to be very promising for applications in the ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1388219

    authors: Olivo A,Arfelli F,Cantatore G,Longo R,Menk RH,Pani S,Prest M,Poropat P,Rigon L,Tromba G,Vallazza E,Castelli E

    更新日期:2001-08-01 00:00:00

  • WE-E-BRA-03: MR Functional Imaging to Guide Radiotherapy: Opportunities and Challenges in the Clinic.

    abstract::Human tumors are characterized by an abnormal vascular network that develops because of unregulated angiogenesis. This contributes to abnormalities of the tumor microenvironment like hypoxia, acidosis and high interstitial fluid pressure that influence treatment response and patient survival. There is an important cli...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4736156

    authors: Milosevic M

    更新日期:2012-06-01 00:00:00

  • An observer study comparing spot imaging regions selected by radiologists and a computer for an automated stereo spot mammography technique.

    abstract::We are developing an automated stereo spot mammography technique for improved imaging of suspicious dense regions within digital mammograms. The technique entails the acquisition of a full-field digital mammogram, automated detection of a suspicious dense region within that mammogram by a computer aided detection (CAD...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1737492

    authors: Goodsitt MM,Chan HP,Lydick JT,Gandra CR,Chen NG,Helvie MA,Bailey JE,Roubidoux MA,Paramagul C,Blane CE,Sahiner B,Petrick NA

    更新日期:2004-06-01 00:00:00

  • 2-Step IMAT and 2-Step IMRT: a geometrical approach.

    abstract::The purpose of this paper is to develop a method that reduces the number of segments for intensity modulated arc therapy (IMAT) and intensity modulated radiotherapy (IMRT) for concave target volumes (TV). The aim was to utilize no more than two intensity levels per organ at risk (OAR) and to derive both optimal segmen...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1861161

    authors: Bratengeier K

    更新日期:2005-03-01 00:00:00

  • Investigating energy deposition in glandular tissues for mammography using multiscale Monte Carlo simulations.

    abstract:PURPOSE:To investigate energy deposition in glandular tissues of the breast on macro- and microscopic length scales in the context of mammography. METHODS:Multiscale mammography models of breasts are developed, which include segmented, voxelized macroscopic tissue structure as well as nine regions of interest (ROIs) e...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13372

    authors: Oliver PAK,Thomson RM

    更新日期:2019-03-01 00:00:00

  • Accuracy, reproducibility, and uncertainty analysis of thyroid-probe-based activity measurements for determination of dose calibrator settings.

    abstract:PURPOSE:In the nuclear medicine department, the activity of radiopharmaceuticals is measured using dose calibrators (DCs) prior to patient injection. The DC consists of an ionization chamber that measures current generated by ionizing radiation (emitted from the radiotracer). In order to obtain an activity reading, the...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4966027

    authors: Esquinas PL,Tanguay J,Gonzalez M,Vuckovic M,Rodríguez-Rodríguez C,Häfeli UO,Celler A

    更新日期:2016-12-01 00:00:00

  • Dynamic field-of-view imaging to increase temporal resolution in the early phase of contrast media uptake in breast DCE-MRI: A feasibility study.

    abstract:PURPOSE:To increase diagnostic accuracy of breast MRI by increasing temporal resolution and more accurately sampling the early kinetics of contrast media uptake. We tested the feasibility of accelerating bilateral breast DCE-MRI by reducing the FOV, allowing aliasing, and unfolding the resulting images. METHODS:Previo...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12747

    authors: Pineda FD,Easley TO,Karczmar GS

    更新日期:2018-03-01 00:00:00

  • Multigroup discrete ordinates modeling of 125I 6702 seed dose distributions using a broad energy-group cross section representation.

    abstract::Our purpose in this work is to demonstrate that the efficiency of dose-rate computations in 125I brachytherapy, using multigroup discrete ordinates radiation transport simulations, can be significantly enhanced using broad energy group cross sections without a loss of accuracy. To this end, the DANTSYS multigroup disc...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1429238

    authors: Daskalov GM,Baker RS,Rogers DW,Williamson JF

    更新日期:2002-02-01 00:00:00

  • Iterative metal artifact reduction for x-ray computed tomography using unmatched projector/backprojector pairs.

    abstract:PURPOSE:Metal artifact reduction (MAR) is a major problem and a challenging issue in x-ray computed tomography (CT) examinations. Iterative reconstruction from sinograms unaffected by metals shows promising potential in detail recovery. This reconstruction has been the subject of much research in recent years. However,...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4950722

    authors: Zhang H,Wang L,Li L,Cai A,Hu G,Yan B

    更新日期:2016-06-01 00:00:00

  • Errors in cerebral blood flow determinations by xenon-enhanced computed tomography due to estimation of arterial xenon concentrations.

    abstract::Errors in the determination of xenon concentrations in arterial blood during inhalation of xenon-oxygen mixtures are used to assess errors in the derivation of regional cerebral blood flow by the xenon-enhanced computed tomography (CT) method. The results of this study indicate that approximating the arterial buildup ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596051

    authors: Good WF,Gur D,Yonas H,Herron JM

    更新日期:1987-05-01 00:00:00

  • A dosimetry study of the Oncoseed 6711 using glass rod dosimeters and EGS5 Monte Carlo code in a geometry lacking radiation equilibrium scatter conditions.

    abstract:PURPOSE:The aim of this study was to develop a dose calculation method which is applicable to the interseed attenuation and the geometry lacking the equilibrium radiation scatter conditions in brachytherapy. METHODS:The dose obtained from measurement with a radiophotoluminescent glass rod dosimeter (GRD) was compared ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3590370

    authors: Tanaka K,Tateoka K,Asanuma O,Kamo K,Bengua G,Sato K,Ueda T,Takeda H,Takagi M,Hareyama M,Takada J

    更新日期:2011-06-01 00:00:00