Abstract:
PURPOSE:In current clinical practice, there is no integrated 3D ultrasound (3DUS) guidance system clinically available for breast brachytherapy. In this study, the authors present a novel robot-assisted 3DUS system for real-time planning and guidance of breast interstitial high dose rate (HDR) brachytherapy treatment. METHODS:For this work, a new computer controlled robotic 3DUS system was built to perform a hybrid motion scan, which is a combination of a 6 cm linear translation with a 30° rotation at both ends. The new 3DUS scanner was designed to fit on a modified Kuske assembly, keeping the current template grid configuration but modifying the frame to allow the mounting of the 3DUS system at several positions. A finer grid was also tested. A user interface was developed to perform image reconstruction, semiautomatic segmentation of the surgical bed as well as catheter reconstruction and tracking. A 3D string phantom was used to validate the geometric accuracy of the reconstruction. The volumetric accuracy of the system was validated with phantoms using magnetic resonance imaging (MRI) and computed tomography (CT) images. In order to accurately determine whether 3DUS can effectively replace CT for treatment planning, the authors have compared the 3DUS catheter reconstruction to the one obtained from CT images. In addition, in agarose-based phantoms, an end-to-end procedure was performed by executing six independent complete procedures with both 14 and 16 catheters, and for both standard and finer Kuske grids. Finally, in phantoms, five end-to-end procedures were performed with the final CT planning for the validation of 3DUS preplanning. RESULTS:The 3DUS acquisition time is approximately 10 s. A paired Student t-test showed that there was no statistical significant difference between known and measured values of string separations in each direction. Both MRI and CT volume measurements were not statistically different from 3DUS volume (Student t-test: p > 0.05) and they were significantly correlated to 3DUS measurement (Pearson test: MRI p < 0.05 and CT p < 0.001). The mean angular separation distance between catheter trajectories segmented from 3DUS and CT images was 0.42° ± 0.24°, while the maximum and mean trajectory separations were 0.51 ± 0.19 and 0.37 ± 0.17 mm, respectively. Overall, the new finer grid has performed significantly better in terms of dosimetric indices. The planning target volume dosimetric indices were not found statistically different between 3DUS and CT planning (Student t-test, p > 0.05). Both the skin and the pectoral muscle dosimetric indices were within ABS guidelines. CONCLUSIONS:A novel robot-assisted 3DUS system was designed and validated. To their knowledge, this is the first system capable of performing real-time guidance and planning of breast multicatheter HDR brachytherapy treatments. Future investigation will test the feasibility of using the system in the clinic and for permanent breast brachytherapy.
journal_name
Med Physjournal_title
Medical physicsauthors
Poulin E,Gardi L,Barker K,Montreuil J,Fenster A,Beaulieu Ldoi
10.1118/1.4934832subject
Has Abstractpub_date
2015-12-01 00:00:00pages
6830-9issue
12eissn
0094-2405issn
2473-4209journal_volume
42pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract:PURPOSE:The purpose of this study is to investigate the feasibility of increasing the system spatial resolution and scanning speed of Hologic Selenia Dimensions digital breast tomosynthesis (DBT) scanner by replacing the rotating mammography x-ray tube with a specially designed carbon nanotube (CNT) x-ray source array,...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3694667
更新日期:2012-04-01 00:00:00
abstract:PURPOSE:Automated segmentation could improve the efficiency of modeling-based pelvic organ prolapse (POP) evaluations. However, segmentation performance is limited by the blurry soft tissue boundaries. In this study, we aimed to present a hybrid solution for uterus, rectum, bladder, and levator ani muscle segmentation ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14377
更新日期:2020-09-01 00:00:00
abstract:PURPOSE:One technical barrier to patient-specific computed tomography (CT) dosimetry has been the lack of computational tools for the automatic patient-specific multi-organ segmentation of CT images and rapid organ dose quantification. When previous CT images are available for the same body region of the patient, the a...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14131
更新日期:2020-06-01 00:00:00
abstract:PURPOSE:To validate GPUMCD, a new package for fast Monte Carlo dose calculations based on the GPU (graphics processing unit), as a tool for low-energy single seed brachytherapy dosimetry for specific seed models. As the currently accepted method of dose calculation in low-energy brachytherapy computations relies on sev...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3598441
更新日期:2011-07-01 00:00:00
abstract::Up to the present, the majority of low contrast object evaluations performed on phantom images have been accomplished in a subjective fashion. This is mainly due to the time and effort required to manually measure each radiograph with a densitometer to obtain quantitative results. However, with the development of digi...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1543153
更新日期:2003-03-01 00:00:00
abstract:PURPOSE:To evaluate a simple, semi-automated lung mass estimation method on CT scans from a variety of acquisition techniques for mass correction of MIRD dose estimates. METHODS:CT scans from ten patients undergoing stereotactic body radiation therapy treatment planning on a GE DST PET/CT scanner were analyzed retrosp...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4734654
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:External beam radiation therapy (EBRT) usually uses heterogeneous dose distributions in a given volume. Designing detectors for quality control of these treatments is still a developing subject. The size of the detectors should be small to enhance spatial resolution and ensure low perturbation of the beam. A hi...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4837178
更新日期:2014-01-01 00:00:00
abstract:PURPOSE:The aim of this study was to implement a Dirichlet process mixture (DPM) model for automatic tumor edge identification on (18)F-fluorodeoxyglucose positron emission tomography ((18)F-FDG PET) images by optimizing the parameters on which the algorithm depends, to validate it experimentally, and to test its robus...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4947123
更新日期:2016-05-01 00:00:00
abstract::Both the design considerations and the dosimetric properties of the Siemens Model 5800 linear accelerator are discussed. This unit is of such an energy (3.3 MV) as to imitate Cobalt-60 teletherapy depth doses. A linear relation of dmax to depth dose at low energies was found for various wave guides and targets. The en...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596487
更新日期:1990-05-01 00:00:00
abstract:PURPOSE:In this article, the authors propose a new gold standard data set for the validation of two-dimensional/three-dimensional (2D/3D) and 3D/3D image registration algorithms. METHODS:A gold standard data set was produced using a fresh cadaver pig head with attached fiducial markers. The authors used several imagin...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3553402
更新日期:2011-03-01 00:00:00
abstract::The surface radio frequency (rf) power absorption in human head and torso nuclear magnetic resonance (NMR) imaging experiments is estimated. The results are expressed as a function of the NMR frequency, the rf pulse length, and the pulse duty cycle, which are varied over six orders of magnitude for general applicabili...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595000
更新日期:1981-07-01 00:00:00
abstract::A method is developed to smooth intensity-modulated beam delivery while considering hardware constraints. The method uses matrix algebra to model MLC leaf motion and hardware constraints such as interleaf digitization, synchronization requirements, and intersegment field abutment to deliver intensity modulated beam se...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1521121
更新日期:2002-12-01 00:00:00
abstract::The authors present an alternative approach to inverse planning optimization and apply it to volumetric modulated are therapy (VMAT) in one rotation with a prior knowledge about the type of leaf motions. The optimization is based on the projection theorem in inner product spaces. MLC motion is directly considered in t...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3173815
更新日期:2009-08-01 00:00:00
abstract::Intensity modulated radiotherapy (IMRT) requires extensive knowledge of multileaf collimator (MLC) leaf positioning accuracy, precision, and long-term reproducibility. We have developed a technique to efficiently measure the absolute position of each MLC leaf, over the range of leaf positions utilized in IMRT, based o...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1564091
更新日期:2003-05-01 00:00:00
abstract:PURPOSE:Plastic scintillation detectors are used for dosimetry in small radiation fields with high dose gradients, e.g., provided by β-emitting sources like 106 Ru/106 Rh eye plaques. A drawback is a background signal caused by Cerenkov radiation generated by electrons passing the optical fibers (light guides) of this ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12374
更新日期:2017-09-01 00:00:00
abstract::The purposes of this study are: (i) to design field flattening filters for the Leipzig applicators of 2 and 3 cm of inner diameter with the source traveling parallel to the applicator contact surface, which are accessories of the microSelectron-HDR afterloader (Nucletron, Veenendaal, The Netherlands). These filters, m...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2825622
更新日期:2008-02-01 00:00:00
abstract:PURPOSE:The accuracy and precision of computed tomography (CT) pulmonary ventilation imaging with conventional CT scanners are limited by breathing variations. We propose a method to correct for the effect of breathing variations in CT ventilation imaging based on external respiratory signals acquired throughout a scan...
journal_title:Medical physics
pub_type: 临床试验,杂志文章
doi:10.1002/mp.12634
更新日期:2018-01-01 00:00:00
abstract:PURPOSE:To analyze the noise performance of the edge illumination phase-based x-ray imaging technique when applying "single-shot" phase retrieval. The latter consists in applying a sample-specific low-pass filter to the raw data, leading to "hybrid" images in which phase and attenuation contrast are merged with each ot...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14366
更新日期:2020-09-01 00:00:00
abstract:PURPOSE:To determine the feasibility and potential utility of cone beam CT on breast biopsies. METHODS:CBCT simulations were done with a setup which emulates an MX-20 digital specimen radiography system (Faxitron X-Ray Corporation, Chicago, IL), albeit a DQE = 1 was assumed. The phantom consisted of a 5mm diameter cyl...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4740191
更新日期:2012-07-01 00:00:00
abstract:PURPOSE:The pulse line ion accelerator (PLIA) is a low-cost accelerator concept originally designed to accelerate heavy ions. Our group has been investigating the use of PLIA to accelerate light ions and believe a multi-stage PLIA could be useful for short half-life PET isotope production. The goal of this work was to ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13875
更新日期:2019-12-01 00:00:00
abstract::Extensive information has been made available relative to the physical aspects necessary for calculation of radiation absorbed dose from radiopharmaceuticals. A similar data base for the biological factors involved in these calculations has not been documented as thoroughly. The authors present an extensive literature...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594679
更新日期:1980-05-01 00:00:00
abstract:PURPOSE:Fusion of intraprocedure ultrasound and preprocedure CT data is proposed for guidance in percutaneous spinal injections, a common procedure for pain management. CT scan of the lumbar spine is usually collected in a supine position, whereas spinal injections are performed in prone or sitting positions. This lead...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4711753
更新日期:2012-06-01 00:00:00
abstract::Previous ultrasound tomography work conducted by our group showed a direct correlation between measured sound speed and physical density in vitro, and increased in vivo sound speed with increasing mammographic density, a known risk factor for breast cancer. Building on these empirical results, the purpose of this work...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2964092
更新日期:2008-09-01 00:00:00
abstract:PURPOSE:The aims of this work were to evaluate the performance of several deformable image registration (DIR) algorithms implemented in our in-house software (NiftyReg) and the uncertainties inherent to using different algorithms for dose warping. METHODS:The authors describe a DIR based adaptive radiotherapy workflow...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4905050
更新日期:2015-02-01 00:00:00
abstract:PURPOSE:The Small Animal Radiation Research Platform (SARRP) has been developed for conformal microirradiation with on-board cone beam CT (CBCT) guidance. The graphics processing unit (GPU)-accelerated Superposition-Convolution (SC) method for dose computation has been integrated into the treatment planning system (TPS...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12862
更新日期:2018-05-01 00:00:00
abstract::Permanent implants of 125I seeds at Memorial Sloan-Kettering Cancer Center are performed by the method of "dimension averaging" to determine the total activity to be implanted; that is, the activity (in mCi) is taken to be five times the average dimension (in cm) of the target region. A nomograph has recently been dev...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594269
更新日期:1976-01-01 00:00:00
abstract:PURPOSE:To develop an accurate and efficient single-marker-based optical tracking system to enhance patient safety and quality of care in radiotherapy. METHODS:The optical tracking system consists of a Polaris camera as well as in-house software. The camera is mounted inside the treatment room and detects the location...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735240
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:Color images are visualized on medical monitors that are adjusted by a grayscale standard display function (GSDF) or γ2.2. Although the GSDF is visually displayed as a linear graded grayscale, it does not specify how color medical images should be presented. On the other hand, the usual gamma setting for color ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13532
更新日期:2019-06-01 00:00:00
abstract:PURPOSE:To investigate dosimetry for ocular brachytherapy for a range of eye plaque models containing(103)Pd, (125)I, or (131)Cs seeds with model-based dose calculations. METHODS:Five representative plaque models are developed based on a literature review and are compared to the standardized COMS plaque, including pla...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4864474
更新日期:2014-03-01 00:00:00
abstract:PURPOSE:Since the first publications on intensity modulated radiation therapy (IMRT) in the early 1980s almost all efforts have been focused on fairly time consuming dynamic or segmental multileaf collimation. With narrow fast scanned photon beams, the flexibility and accuracy in beam shaping increases, not least in co...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3615059
更新日期:2011-08-01 00:00:00