Abstract:
PURPOSE:One technical barrier to patient-specific computed tomography (CT) dosimetry has been the lack of computational tools for the automatic patient-specific multi-organ segmentation of CT images and rapid organ dose quantification. When previous CT images are available for the same body region of the patient, the ability to obtain patient-specific organ doses for CT - in a similar manner as radiation therapy treatment planning - will open the door to personalized and prospective CT scan protocols. This study aims to demonstrate the feasibility of combining deep-learning algorithms for automatic segmentation of multiple radiosensitive organs from CT images with the GPU-based Monte Carlo rapid organ dose calculation. METHODS:A deep convolutional neural network (CNN) based on the U-Net for organ segmentation is developed and trained to automatically delineate multiple radiosensitive organs from CT images. Two databases are used: The lung CT segmentation challenge 2017 (LCTSC) dataset that contains 60 thoracic CT scan patients, each consisting of five segmented organs, and the Pancreas-CT (PCT) dataset, which contains 43 abdominal CT scan patients each consisting of eight segmented organs. A fivefold cross-validation method is performed on both sets of data. Dice similarity coefficients (DSCs) are used to evaluate the segmentation performance against the ground truth. A GPU-based Monte Carlo dose code, ARCHER, is used to calculate patient-specific CT organ doses. The proposed method is evaluated in terms of relative dose errors (RDEs). To demonstrate the potential improvement of the new method, organ dose results are compared against those obtained for population-average patient phantoms used in an off-line dose reporting software, VirtualDose, at Massachusetts General Hospital. RESULTS:The median DSCs are found to be 0.97 (right lung), 0.96 (left lung), 0.92 (heart), 0.86 (spinal cord), 0.76 (esophagus) for the LCTSC dataset, along with 0.96 (spleen), 0.96 (liver), 0.95 (left kidney), 0.90 (stomach), 0.87 (gall bladder), 0.80 (pancreas), 0.75 (esophagus), and 0.61 (duodenum) for the PCT dataset. Comparing with organ dose results from population-averaged phantoms, the new patient-specific method achieved smaller absolute RDEs (mean ± standard deviation) for all organs: 1.8% ± 1.4% (vs 16.0% ± 11.8%) for the lung, 0.8% ± 0.7% (vs 34.0% ± 31.1%) for the heart, 1.6% ± 1.7% (vs 45.7% ± 29.3%) for the esophagus, 0.6% ± 1.2% (vs 15.8% ± 12.7%) for the spleen, 1.2% ± 1.0% (vs 18.1% ± 15.7%) for the pancreas, 0.9% ± 0.6% (vs 20.0% ± 15.2%) for the left kidney, 1.7% ± 3.1% (vs 19.1% ± 9.8%) for the gallbladder, 0.3% ± 0.3% (vs 24.2% ± 18.7%) for the liver, and 1.6% ± 1.7% (vs 19.3% ± 13.6%) for the stomach. The trained automatic segmentation tool takes <5 s per patient for all 103 patients in the dataset. The Monte Carlo radiation dose calculations performed in parallel to the segmentation process using the GPU-accelerated ARCHER code take <4 s per patient to achieve <0.5% statistical uncertainty in all organ doses for all 103 patients in the database. CONCLUSION:This work shows the feasibility to perform combined automatic patient-specific multi-organ segmentation of CT images and rapid GPU-based Monte Carlo dose quantification with clinically acceptable accuracy and efficiency.
journal_name
Med Physjournal_title
Medical physicsauthors
Peng Z,Fang X,Yan P,Shan H,Liu T,Pei X,Wang G,Liu B,Kalra MK,Xu XGdoi
10.1002/mp.14131subject
Has Abstractpub_date
2020-06-01 00:00:00pages
2526-2536issue
6eissn
0094-2405issn
2473-4209journal_volume
47pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract:PURPOSE:The authors investigate the impact that incremental increases in the level of detail of patient-specific prior information have on image quality and the convergence behavior of an inversion algorithm in the context of near-field microwave breast imaging. A methodology is presented that uses image quality measur...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12585
更新日期:2017-12-01 00:00:00
abstract::Magnetic resonance (MR) measurements of relaxation times and diffusion coefficient in tissue have been demonstrated to be sensitive to biological changes induced by radiation therapy. We are currently using mouse models of human glioblastoma multiforme (GBM) to study tumour response to ionizing radiation by MRI at 9.4...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2965985
更新日期:2008-07-01 00:00:00
abstract::The synchronization of dynamic multileaf collimator (DMLC) response with respiratory motion is critical to ensure the accuracy of DMLC-based four dimensional (4D) radiation delivery. In practice, however, a finite time delay (response time) between the acquisition of tumor position and multileaf collimator response ne...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1915017
更新日期:2005-06-01 00:00:00
abstract:PURPOSE:Radiotherapy is an effective treatment for many types of cancer in clinical settings. Gel dosimetry has the potential to record three-dimensional (3D) dose distribution compared to a conventional ion chamber. As the elasticity of the gel is altered after irradiation due to gel polymerization, we aim to measure ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14020
更新日期:2020-03-01 00:00:00
abstract::A photon transport algorithm for fully three-dimensional radiotherapy treatment planning has been developed based on the discrete ordinates (SN) solution of the Boltzmann equation. The algorithm is characterized by orthogonal adaptive meshes, which place additional points where large gradients occur and a procedure to...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2960247
更新日期:2008-09-01 00:00:00
abstract::The goal is to perform geometric studies on cone-beam CT scanning along a three-dimensional (3D) spiral of variable radius. First, the background for variable radius spiral cone-beam scanning is given in the context of electron-beam CT/micro-CT. Then, necessary and sufficient conditions are proved for existence and un...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1751251
更新日期:2004-06-01 00:00:00
abstract:PURPOSE:To investigate the effect of the number of projection views on image noise in cone-beam CT (CBCT) with a flat-panel detector. METHODS:This fairly fundamental consideration in CBCT system design and operation was addressed experimentally (using a phantom presenting a uniform medium as well as statistically moti...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4875688
更新日期:2014-06-01 00:00:00
abstract::The purpose of this paper is to determine the correlation between dose-volume histogram (DVH) and dose wall-histogram (DWH) in the evaluation of rectal complications for prostate cancer patients treated with three-dimensional conformal radiotherapy (3D-CRT). A retrospective analysis of DVHs and DWHs of a subset of 25 ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1951427
更新日期:2005-08-01 00:00:00
abstract::A double-mirror multilayer monochromator was developed for the purpose of irradiating live cell cultures at the Synchrotron Radiation Center, University of Wisconsin-Madison. The monochromator is designed for the soft x-ray region with photon energies between 270 and 2400 eV. Multilayer mirrors with 55 bilayers of W/C...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598259
更新日期:1998-05-01 00:00:00
abstract::Quantitative analysis of dynamic gadolinium-DTPA (diethylenetriamine pentaacetic acid) enhanced magnetic resonance imaging (MRI) is emerging as a highly sensitive tool for detecting malignant breast tissue. Three-dimensional rapid imaging techniques, such as keyhole MRI, yield high temporal sampling rates to accuratel...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598576
更新日期:1999-05-01 00:00:00
abstract:PURPOSE:The purpose of this study is to estimate the effect of edema, developed during implant procedure, on tumor cell surviving fraction(SF) and tumor control probability(TCP) in the patients of prostate cancer who underwent 131 Cs permanent seed implants. METHODS:The impact of edema on SF and TCP, was calculated us...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735061
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:To demonstrate the feasibility of a three-plenoptic camera projection, scintillation-based dosimetry system for measuring three-dimensional (3D) dose distributions of static photon radiation fields. METHODS:Static x-ray photon beams were delivered to a cubic plastic scintillator volume embedded within acrylic ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14213
更新日期:2020-08-01 00:00:00
abstract::Gafchromic XRCT, radiochromic film is assessed over a broad energy range, from kilovoltage to megavoltage x rays for variations in reflected optical density to dose response. A large energy dependence was found with reflected optical density output for the same delivered dose varying from 7.8 +/- 0.35 at 25.5 keV (50 ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2219330
更新日期:2006-08-01 00:00:00
abstract:PURPOSE:Currently, in clinical practice of intensity-modulated proton therapy (IMPT), the influence of the minimum monitor unit (MU) constraint is taken into account through postprocessing after the optimization is completed. This may degrade the plan quality and plan robustness. This study aims to mitigate the impact ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12677
更新日期:2018-01-01 00:00:00
abstract:PURPOSE:To construct a Monte Carlo (MC)-based simulation model for analyzing the dependence of tumor oxygen distribution on different variables related to tumor vasculature [blood velocity, vessel-to-vessel proximity (vessel proximity), and inflowing oxygen partial pressure (pO2)]. METHODS:A voxel-based tissue model c...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4892386
更新日期:2014-09-01 00:00:00
abstract:PURPOSE:Results about the feasibility of a method for quasi real time in vivo dosimetry (IVD) at the isocenter point for volumetric modulated arc therapy (VMAT) are here reported. The method is based on correlations between the EPID signal and the dose on the beam central axis. Moreover, the γ-analysis of EPID images w...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4875685
更新日期:2014-06-01 00:00:00
abstract::In a recent paper of Miller et al. (Med. Phys. 43(5), 2141-2152 (2016), the voltage dependence polarity effect of microionization chambers was studied. It was identified that polarity effect arises from the difference in electric potential between the collecting electrode and the guard electrode, which in turn deforms...
journal_title:Medical physics
pub_type: 信件
doi:10.1002/mp.12019
更新日期:2017-03-01 00:00:00
abstract::The aim of this work was to test the suitability of a PTW diamond detector for nonreference condition dosimetry in photon beams of different energy (6 and 25 MV) and field size (from 2.6 cm x 2.6 cm to 10 cm x 10 cm). Diamond behavior was compared to that of a Scanditronix p-type silicon diode and a Scanditronix RK io...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1591431
更新日期:2003-08-01 00:00:00
abstract:PURPOSE:The spatial resolution of iterative reconstruction (IR) in computed tomography (CT) is contrast- and noise-dependent because of the nonlinear regularization. Due to the severe noise contamination, it is challenging to perform precise spatial-resolution measurements at very low-contrast levels. The purpose of th...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4916802
更新日期:2015-05-01 00:00:00
abstract::Testing computer-controlled linear accelerators for patient safety and proper patient dose delivery requires that certain beam characteristics be monitored over an extended period of time. Computer-controlled conformal radiation therapy using asymmetric collimator jaw settings necessitates stable symmetric treatment b...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596363
更新日期:1989-07-01 00:00:00
abstract:PURPOSE:To accurately and efficiently implement charged particle transport in a magnetic field in EGSnrc and validate the code for the use in phantom and ion chamber simulations. METHODS:The effect of the magnetic field on the particle motion and position is determined using one- and three-point numerical integrations...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4954318
更新日期:2016-07-01 00:00:00
abstract:PURPOSE:The standardized uptake value (SUV) is a quantitative measure of FDG tumor uptake frequently used as a tool to monitor therapeutic response. This study aims to (i) assess the reproducibility and uncertainty of SUV max and SUV mean, due to purely statistical, i.e., nonbiological, effects and (ii) to establish th...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3578604
更新日期:2011-05-01 00:00:00
abstract::Based on direction from AAM Board of Directors, JMPLSC has redefined its scope and name. On November 4, 2011 the subcommittee renamed itself the Medical Physics Licensure and Regulatory Recognition Subcommittee. Its newly defined charge is to promote the protection of the public through the recognition of the professi...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735947
更新日期:2012-06-01 00:00:00
abstract::The calibration (in rad/nC) of an air-filled tissue-equivalent ionization chamber for neutrons of 15-MeV average energy was determined by measuring absolute fluences and calculating the kerma per unit fluence. The neutron calibration determined from the gamma-ray calibration and application of the Bragg-Gray relation ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594310
更新日期:1977-03-01 00:00:00
abstract:PURPOSE:Deformable image registration (DIR) is often validated based on a distance-to-agreement (DTA) criterion of automatically propagated anatomical landmarks that were manually identified. Due to human observer variability, however, the performance of the registration method is diluted. The purpose of this study was...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4760990
更新日期:2012-11-01 00:00:00
abstract::The determination of the radiation exposure history of the population has become increasingly important in the study of the effects of low-level radiation. The present work was started to try to obtain an in vivo dosimeter that could give an indication of radiation exposure. Dental enamel is the only living tissue whi...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595768
更新日期:1985-05-01 00:00:00
abstract::A method for finding optimal primary fluence profiles for multiple field external beam radiation therapy techniques has been developed using a radiobiologically based objective function that quantifies the probability of achieving complication-free tumor control, P+. The objective function P+ has the valuable property...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596971
更新日期:1993-07-01 00:00:00
abstract::Diode sensitivity variations with temperature (SVWT) have been reported to vary from small negative values up to 0.6% per degrees C. Thus it is possible for diode calibration factors established at room temperature (approximately 20 degrees C) to yield errors in the range of -1% to +9% when diodes are placed on a pati...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1367862
更新日期:2001-05-01 00:00:00
abstract::The paper presents a theoretical derivation of the photon fluence simulation efficiency in photon beam treatment head simulations without and with bremsstrahlung splitting. The expressions obtained provide a rigorous explanation of the efficiency dependence on scoring zone size and splitting number and explain the lar...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1943808
更新日期:2005-07-01 00:00:00
abstract:PURPOSE:In CT-guided liver tumor ablation interventions, registration of a preoperative contrast-enhanced CT image to the intraoperative CT image is hypothesized to improve guidance. This is a highly challenging registration task due to differences in patient poses and large deformations, and therefore high registratio...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12332
更新日期:2017-07-01 00:00:00