Dosimetric impact of geometric errors due to respiratory motion prediction on dynamic multileaf collimator-based four-dimensional radiation delivery.

Abstract:

:The synchronization of dynamic multileaf collimator (DMLC) response with respiratory motion is critical to ensure the accuracy of DMLC-based four dimensional (4D) radiation delivery. In practice, however, a finite time delay (response time) between the acquisition of tumor position and multileaf collimator response necessitates predictive models of respiratory tumor motion to synchronize radiation delivery. Predicting a complex process such as respiratory motion introduces geometric errors, which have been reported in several publications. However, the dosimetric effect of such errors on 4D radiation delivery has not yet been investigated. Thus, our aim in this work was to quantify the dosimetric effects of geometric error due to prediction under several different conditions. Conformal and intensity modulated radiation therapy (IMRT) plans for a lung patient were generated for anterior-posterior/posterior-anterior (AP/PA) beam arrangements at 6 and 18 MV energies to provide planned dose distributions. Respiratory motion data was obtained from 60 diaphragm-motion fluoroscopy recordings from five patients. A linear adaptive filter was employed to predict the tumor position. The geometric error of prediction was defined as the absolute difference between predicted and actual positions at each diaphragm position. Distributions of geometric error of prediction were obtained for all of the respiratory motion data. Planned dose distributions were then convolved with distributions for the geometric error of prediction to obtain convolved dose distributions. The dosimetric effect of such geometric errors was determined as a function of several variables: response time (0-0.6 s), beam energy (6/18 MV), treatment delivery (3D/4D), treatment type (conformal/IMRT), beam direction (AP/PA), and breathing training type (free breathing/audio instruction/visual feedback). Dose difference and distance-to-agreement analysis was employed to quantify results. Based on our data, the dosimetric impact of prediction (a) increased with response time, (b) was larger for 3D radiation therapy as compared with 4D radiation therapy, (c) was relatively insensitive to change in beam energy and beam direction, (d) was greater for IMRT distributions as compared with conformal distributions, (e) was smaller than the dosimetric impact of latency, and (f) was greatest for respiration motion with audio instructions, followed by visual feedback and free breathing. Geometric errors of prediction that occur during 4D radiation delivery introduce dosimetric errors that are dependent on several factors, such as response time, treatment-delivery type, and beam energy. Even for relatively small response times of 0.6 s into the future, dosimetric errors due to prediction could approach delivery errors when respiratory motion is not accounted for at all. To reduce the dosimetric impact, better predictive models and/or shorter response times are required.

journal_name

Med Phys

journal_title

Medical physics

authors

Vedam S,Docef A,Fix M,Murphy M,Keall P

doi

10.1118/1.1915017

subject

Has Abstract

pub_date

2005-06-01 00:00:00

pages

1607-20

issue

6

eissn

0094-2405

issn

2473-4209

journal_volume

32

pub_type

杂志文章
  • Technical Note: Performance comparison of ultra-high-resolution scan modes of two clinical computed tomography systems.

    abstract:PURPOSE:Two ultra-high-resolution (UHR) computed tomography (CT) scanners are clinically available. One is achieved by a CT system with a 0.25 mm × 160 row detector (Detector-UHR), whereas the other is with a 0.6 mm × 32 row detector with in-plane comb filtering in a dual source CT (Comb-UHR). We compared radiation dos...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13949

    authors: Kawashima H,Ichikawa K,Takata T,Nagata H,Hoshika M,Akagi N

    更新日期:2020-02-01 00:00:00

  • Effect of longitudinal magnetic fields on a simulated in-line 6 MV linac.

    abstract:PURPOSE:Linac-magnetic resonance (MR) systems have been proposed in order to achieve realtime image guided radiotherapy. The design of a new linac-MR system with the in-line 6 MV linac generating x-rays along the symmetry axis of an open MR imager is outlined. This new design allows for a greater MR field strength to a...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3481513

    authors: St Aubin J,Santos DM,Steciw S,Fallone BG

    更新日期:2010-09-01 00:00:00

  • Measurement of x-ray attenuation coefficients of aqueous solutions of indocyanine green and glycated chitosan.

    abstract::We report our experimental results of measurements of x-ray attenuation coefficients of aqueous solutions of a light absorbing dye, indocyanine green, and an immunoadjuvant, glycated chitosan. In the treatment of metastatic tumors in rats using a novel laser immunotherapy these solutions were administered in situ. The...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598633

    authors: Xu F,Liu H,Wu X,Jiang H,Nordquist RE,Chen WR

    更新日期:1999-07-01 00:00:00

  • Evaluation of carbon nanotube x-ray source array for stationary head computed tomography.

    abstract:PURPOSE:Stationary computed tomography (s-CT) conceptually offers several advantages over existing rotating gantry-based CT. Over the last 40 yr, s-CT has been investigated using different technological approaches. We are developing a s-CT system specifically for head/brain imaging using carbon nanotube (CNT)-based fie...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14696

    authors: Spronk D,Luo Y,Inscoe CR,Lee YZ,Lu J,Zhou O

    更新日期:2020-12-31 00:00:00

  • VMAT and IMRT plan-specific correction factors for linac-based ionization chamber dosimetry.

    abstract:PURPOSE:The determination of absorbed dose to water from external beam radiotherapy using radiation detectors is currently rooted in calibration protocols that do not account for modulations encountered in patient-specific deliveries. Detector response in composite clinical fields has not been extensively studied due t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13293

    authors: Desai VK,Labby ZE,Hyun MA,DeWerd LA,Culberson WS

    更新日期:2019-02-01 00:00:00

  • Registration of central paths and colonic polyps between supine and prone scans in computed tomography colonography: pilot study.

    abstract::Computed tomography colonography (CTC) is a minimally invasive method that allows the evaluation of the colon wall from CT sections of the abdomen/pelvis. The primary goal of CTC is to detect colonic polyps, precursors to colorectal cancer. Because imperfect cleansing and distension can cause portions of the colon wal...

    journal_title:Medical physics

    pub_type: 临床试验,杂志文章

    doi:10.1118/1.1796171

    authors: Li P,Napel S,Acar B,Paik DS,Jeffrey RB Jr,Beaulieu CF

    更新日期:2004-10-01 00:00:00

  • Prevention of a wrong-location misadministration through the use of an intradepartmental incident learning system.

    abstract:PURPOSE:A series of examples are presented in which potential errors in the delivery of radiation therapy were prevented through use of incident learning. These examples underscore the value of reporting near miss incidents. METHODS:Using a departmental incident learning system, eight incidents were noted over a two-y...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4760774

    authors: Ford EC,Smith K,Harris K,Terezakis S

    更新日期:2012-11-01 00:00:00

  • Technical note: Correlation of respiratory motion between external patient surface and internal anatomical landmarks.

    abstract:PURPOSE:Current respiratory motion monitoring devices used for motion synchronization in medical imaging and radiotherapy provide either 1D respiratory signal over a specific region or 3D information based on few external or internal markers. On the other hand, newer technology may offer the potential to monitor the en...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3589131

    authors: Fayad H,Pan T,Clement JF,Visvikis D

    更新日期:2011-06-01 00:00:00

  • Model-based calculations of off-axis ratio of conic beams for a dedicated 6 MV radiosurgery unit.

    abstract:PURPOSE:Because the small-radius photon beams shaped by cones in stereotactic radiosurgery (SRS) lack lateral electronic equilibrium and a detector's finite cross section, direct experimental measurement of dosimetric data for these beams can be subject to large uncertainties. As the dose calculation accuracy of a trea...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3488900

    authors: Yang JN,Ding X,Du W,Pino R

    更新日期:2010-10-01 00:00:00

  • Three dimensional intensity modulated brachytherapy (IMBT): dosimetry algorithm and inverse treatment planning.

    abstract:PURPOSE:The feasibility of intensity modulated brachytherapy (IMBT) to improve dose conformity for irregularly shaped targets has been previously investigated by researchers by means of using partially shielded sources. However, partial shielding does not fully explore the potential of IMBT. The goal of this study is t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3456598

    authors: Shi C,Guo B,Cheng CY,Esquivel C,Eng T,Papanikolaou N

    更新日期:2010-07-01 00:00:00

  • Noninvasive cardiac arrhythmia ablation with particle beams.

    abstract::Cardiac arrhythmias are a major health burden, associated with reduced quality of life and substantial morbidity and mortality. Current therapy includes moderately effective medication and catheter-based ablation of arrhythmogenic substrates in the heart. Catheter interventions frequently have to be repeated due to re...

    journal_title:Medical physics

    pub_type: 杂志文章,评审

    doi:10.1002/mp.12595

    authors: Graeff C,Bert C

    更新日期:2018-11-01 00:00:00

  • Speckle contrast diffuse correlation tomography of complex turbid medium flow.

    abstract:PURPOSE:Developed herein is a three-dimensional (3D) flow contrast imaging system leveraging advancements in the extension of laser speckle contrast imaging theories to deep tissues along with our recently developed finite-element diffuse correlation tomography (DCT) reconstruction scheme. This technique, termed speckl...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4922206

    authors: Huang C,Irwin D,Lin Y,Shang Y,He L,Kong W,Luo J,Yu G

    更新日期:2015-07-01 00:00:00

  • Analytic microdosimetry for radioimmunotherapeutic alpha emitters.

    abstract::Analytic microdosimetry using Fourier transform techniques has been applied to internal alpha emitters. These techniques need revision and simplification for use with short-lived radionuclides such as those which may be useful for radioimmunotherapy. Analytic methods may have advantages over Monte Carlo methods in som...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596770

    authors: Stinchcomb TG,Roeske JC

    更新日期:1992-11-01 00:00:00

  • Anatomical noise in contrast-enhanced digital mammography. Part I. Single-energy imaging.

    abstract:PURPOSE:The use of an intravenously injected iodinated contrast agent could help increase the sensitivity of digital mammography by adding information on tumor angiogenesis. Two approaches have been made for clinical implementation of contrast-enhanced digital mammography (CEDM), namely, single-energy (SE) and dual-ene...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4801905

    authors: Hill ML,Mainprize JG,Carton AK,Muller S,Ebrahimi M,Jong RA,Dromain C,Yaffe MJ

    更新日期:2013-05-01 00:00:00

  • SU-E-T-610: Impact of Variable Beam Spot Size on Treatment Time in Particle Therapy.

    abstract:PURPOSE:The dosimetric advantage of particle therapy comes with a much higher infrastructure investment and operation costs. Increasing patient throughput is a key factor to manage operation costs. We investigate the impact of variable beam spot sizes on treatment time and discuss the tradeoffs involved. METHODS:The f...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735699

    authors: Riofrio D,Sellner S,Cabal G,Keyes R,Holzscheiter M,Jaekel O,Luan S

    更新日期:2012-06-01 00:00:00

  • Second cancer incidence risk estimates using BEIR VII models for standard and complex external beam radiotherapy for early breast cancer.

    abstract:PURPOSE:To compare organ specific cancer incidence risks for standard and complex external beam radiotherapy (including cone beam CT verification) following breast conservation surgery for early breast cancer. METHOD:Doses from breast radiotherapy and kilovoltage cone beam CT (CBCT) exposures were obtained from thermo...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4748332

    authors: Donovan EM,James H,Bonora M,Yarnold JR,Evans PM

    更新日期:2012-10-01 00:00:00

  • Differences among Monte Carlo codes in the calculations of voxel S values for radionuclide targeted therapy and analysis of their impact on absorbed dose evaluations.

    abstract::Several updated Monte Carlo (MC) codes are available to perform calculations of voxel S values for radionuclide targeted therapy. The aim of this work is to analyze the differences in the calculations obtained by different MC codes and their impact on absorbed dose evaluations performed by voxel dosimetry. Voxel S val...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3103401

    authors: Pacilio M,Lanconelli N,Lo MS,Betti M,Montani L,Torres AL,Coca PM

    更新日期:2009-05-01 00:00:00

  • Mineralization in calcified plaque is like that of cortical bone--further evidence from ultrashort echo time (UTE) magnetic resonance imaging of carotid plaque calcification and cortical bone.

    abstract:PURPOSE:This study aims to investigate carotid plaque calcification (CPC) using two-dimensional (2D) and 3D ultrashort echo time (UTE) magnetic resonance imaging (MRI) sequences and compare T1, T2*, water concentration, and bone mineral density (BMD) of CPC with those of cortical bone. METHODS:Twelve carotid plaque sp...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4819944

    authors: Du J,Peterson M,Kansal N,Bydder GM,Kahn A

    更新日期:2013-10-01 00:00:00

  • High resolution digital autoradiographic and dosimetric analysis of heterogeneous radioactivity distribution in xenografted prostate tumors.

    abstract:PURPOSE:The first main aim of this study was to illustrate the absorbed dose rate distribution from 177Lu in sections of xenografted prostate cancer (PCa) tumors using high resolution digital autoradiography (DAR) and compare it with hypothetical identical radioactivity distributions of 90Y or 7 MeV alpha-particles. Th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4967877

    authors: Timmermand OV,Nilsson J,Strand SE,Elgqvist J

    更新日期:2016-12-01 00:00:00

  • Anisotropy functions for 103Pd, 125I, and 192Ir interstitial brachytherapy sources.

    abstract::Anisotropy of dose distributions around 103Pd, 125I, and 192Ir sources for interstitial brachytherapy was examined. Dose rates around 125I models 6702 and 6711 and 192Ir sources were measured using lithium fluoride thermoluminescence dosimeters (LiF TLDs) in a water-equivalent, solid phantom. From these measured data ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597110

    authors: Nath R,Meigooni AS,Muench P,Melillo A

    更新日期:1993-09-01 00:00:00

  • The determination of electron density by the dual-energy Compton scatter method.

    abstract::The intensity of Compton scattered photons is directly proportional to the electron density of a substance; therefore it is possible to detect changes in electron density by this noninvasive method. The source-detector geometry has been varied to study the effects of geometry on the calculated electron density values,...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595730

    authors: Huddleston AL,Sackler JP

    更新日期:1985-01-01 00:00:00

  • Improvement of off-axis SABR plan verification results by using adapted dose reconstruction algorithms for the Octavius 4D system.

    abstract:PURPOSE:Stereotactic ablative body radiotherapy (SABR) for lung patients can be performed with volumetric-modulated arc therapy (VMAT) plans using off-axis target geometry to allow treatment in their CBCT verified position. For patient-specific quality assurance measurements using the PTW Octavius 4D phantom (PTW, Frei...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12805

    authors: Jeevanandam P,Agnew CE,Irvine DM,McGarry CK

    更新日期:2018-04-01 00:00:00

  • Noncoplanar VMAT for nasopharyngeal tumors: Plan quality versus treatment time.

    abstract:PURPOSE:The authors investigated the potential of optimized noncoplanar irradiation trajectories for volumetric modulated arc therapy (VMAT) treatments of nasopharyngeal patients and studied the trade-off between treatment plan quality and delivery time in radiation therapy. METHODS:For three nasopharyngeal patients, ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4914863

    authors: Wild E,Bangert M,Nill S,Oelfke U

    更新日期:2015-05-01 00:00:00

  • Feasibility study on inverse four-dimensional dose reconstruction using the continuous dose-image of EPID.

    abstract:PURPOSE:When an intensity-modulated radiation beam is delivered to a moving target, the interplay effect between dynamic beam delivery and the target motion due to miss-synchronization can cause unpredictable dose delivery. The portal dose image in electronic portal imaging device (EPID) represents radiation attenuated...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4799941

    authors: Yeo IJ,Jung JW,Yi BY,Kim JO

    更新日期:2013-05-01 00:00:00

  • Determination of the reference air kerma rate for 192Ir brachytherapy sources and the related uncertainty.

    abstract::Different methods exist to determine the air kerma calibration factor of an ionization chamber for the spectrum of a 192Ir high-dose-rate (HDR) or pulsed-dose-rate (PDR) source. An analysis of two methods to obtain such a calibration factor was performed: (i) the method recommended by [Goetsch et al., Med. Phys. 18, 4...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1791352

    authors: van Dijk E,Kolkman-Deurloo IK,Damen PM

    更新日期:2004-10-01 00:00:00

  • Pulmonary nodule detection in CT images based on shape constraint CV model.

    abstract:PURPOSE:Accurate detection of pulmonary nodules remains a technical challenge in computer-aided diagnosis systems because some nodules may adhere to the blood vessels or the lung wall, which have low contrast compared to the surrounding tissues. In this paper, the analysis of typical shape features of candidate nodules...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4907961

    authors: Wang B,Tian X,Wang Q,Yang Y,Xie H,Zhang S,Gu L

    更新日期:2015-03-01 00:00:00

  • Simulated accuracy assessment of small footprint body-mounted probe alignment device for MRI-guided cryotherapy of abdominal lesions.

    abstract:PURPOSE:Magnetic resonance imaging (MRI)-guided percutaneous cryotherapy of abdominal lesions, an established procedure, uses MRI to guide and monitor the cryoablation of lesions. Methods to precisely guide cryotherapy probes with a minimum amount of trial-and-error are yet to be established. To aid physicians in attai...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14116

    authors: Shono N,Ninni B,King F,Kato T,Tokuda J,Fujimoto T,Tuncali K,Hata N

    更新日期:2020-06-01 00:00:00

  • Optimization of MR pulse sequences for Bayesian image segmentation.

    abstract::A method for optimizing MR imaging pulse sequence parameters in a statistical framework is presented. Parameters are defined to be optimal when the resulting scalar images yield optimal image segmentations using Bayesian pixel classification. Thus, Bayes risk is used as the objective function to minimize. Approximatio...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597425

    authors: Prince JL,Pham D,Tan O

    更新日期:1995-10-01 00:00:00

  • Experimental implementation of a joint statistical image reconstruction method for proton stopping power mapping from dual-energy CT data.

    abstract:PURPOSE:To experimentally commission a dual-energy CT (DECT) joint statistical image reconstruction (JSIR) method, which is built on a linear basis vector model (BVM) of material characterization, for proton stopping power ratio (SPR) estimation. METHODS:The JSIR-BVM method builds on the relationship between the energ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13287

    authors: Zhang S,Han D,Williamson JF,Zhao T,Politte DG,Whiting BR,O'Sullivan JA

    更新日期:2019-01-01 00:00:00

  • Ultrasound contrast-detail analysis: a preliminary study in human observer performance.

    abstract::Results of a human observer performance study using a new ultrasound contrast-detail (CD) phantom are reported. The new phantom allows estimates of the fundamental statistical uncertainties involved in CD analysis. Results of these experiments show that observers generally considered to be "trained" require experience...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597147

    authors: Hall TJ,Insana MF,Soller NM,Harrison LA

    更新日期:1993-01-01 00:00:00