Abstract:
:Several updated Monte Carlo (MC) codes are available to perform calculations of voxel S values for radionuclide targeted therapy. The aim of this work is to analyze the differences in the calculations obtained by different MC codes and their impact on absorbed dose evaluations performed by voxel dosimetry. Voxel S values for monoenergetic sources (electrons and photons) and different radionuclides (90Y, 131I, and 188Re) were calculated. Simulations were performed in soft tissue. Three general-purpose MC codes were employed for simulating radiation transport: MCNP4C, EGSnrc, and GEANT4. The data published by the MIRD Committee in Pamphlet No. 17, obtained with the EGS4 MC code, were also included in the comparisons. The impact of the differences (in terms of voxel S values) among the MC codes was also studied by convolution calculations of the absorbed dose in a volume of interest. For uniform activity distribution of a given radionuclide, dose calculations were performed on spherical and elliptical volumes, varying the mass from 1 to 500 g. For simulations with monochromatic sources, differences for self-irradiation voxel S values were mostly confined within 10% for both photons and electrons, but with electron energy less than 500 keV, the voxel S values referred to the first neighbor voxels showed large differences (up to 130%, with respect to EGSnrc) among the updated MC codes. For radionuclide simulations, noticeable differences arose in voxel S values, especially in the bremsstrahlung tails, or when a high contribution from electrons with energy of less than 500 keV is involved. In particular, for 90Y the updated codes showed a remarkable divergence in the bremsstrahlung region (up to about 90% in terms of voxel S values) with respect to the EGS4 code. Further, variations were observed up to about 30%, for small source-target voxel distances, when low-energy electrons cover an important part of the emission spectrum of the radionuclide (in our case, for 131I). For 90Y and 188Re, the differences among the various codes have a negligible impact (within few percents) on convolution calculations of the absorbed dose; thus either one of the MC programs is suitable to produce voxel S values for radionuclide targeted therapy dosimetry. However, if a low-energy beta-emitting radionuclide is considered, these differences can affect also dose depositions at small source-target voxel distances, leading to more conspicuous variations (about 9% for 1311) when calculating the absorbed dose in the volume of interest.
journal_name
Med Physjournal_title
Medical physicsauthors
Pacilio M,Lanconelli N,Lo MS,Betti M,Montani L,Torres AL,Coca PMdoi
10.1118/1.3103401subject
Has Abstractpub_date
2009-05-01 00:00:00pages
1543-52issue
5eissn
0094-2405issn
2473-4209journal_volume
36pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract::A commercial optical system developed by Solid Photography, Inc., has been used to generate precise paraffin--polyethylene tissue compensators. A program with the objective of constructing a medical facility has been undertaken to access patient topology for treatment planning, tissue-compensator fabrication, and pati...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594447
更新日期:1978-11-01 00:00:00
abstract::The use of electronic portal imaging devices (EPIDs) is a promising method for the dosimetric verification of external beam, megavoltage radiation therapy-both pretreatment and in vivo. In this study, a previously developed EPID back-projection algorithm was modified for IMRT techniques and applied to an amorphous sil...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2147744
更新日期:2006-02-01 00:00:00
abstract:PURPOSE:This study aimed to introduce heat map, a graphical data presentation method widely used in gene expression experiments, to the presentation and interpretation of image fidelity assessment data of compressed computed tomography (CT) images. METHODS:The authors used actual assessment data that consisted of five...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3611046
更新日期:2011-08-01 00:00:00
abstract:PURPOSE:Traditionally, unidirectional leaf-sweeping schemes have been employed to deliver IMRT plans using the dynamic multileaf collimator (DMLC) technique. The goal of this research is to investigate the potential impact of relaxing the leaf-motion restrictions in DMLC IMRT on the beam-modulation quality and the deli...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13158
更新日期:2018-11-01 00:00:00
abstract:PURPOSE:Mammography is known to be one of the most difficult radiographic exams to interpret. Mammography has important limitations, including the superposition of normal tissue that can obscure a mass, chance alignment of normal tissue to mimic a true lesion and the inability to derive volumetric information. It has b...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3562901
更新日期:2011-04-01 00:00:00
abstract::Total scalp irradiation is a treatment technique used for a variety of superficial malignancies. Helical tomotherapy is an effective technique used for total scalp irradiation. Recent published work has shown the TomoTherapy planning system to overestimate the superficial dose. In this study, the superficial doses for...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2996288
更新日期:2008-11-01 00:00:00
abstract:PURPOSE:When designing a collimation system for pencil beam spot scanning proton therapy, a decision must be made whether or not to rotate, or focus, the collimator to match beamlet deflection as a function of off-axis distance. If the collimator is not focused, the beamlet shape and fluence will vary as a function of ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14139
更新日期:2020-07-01 00:00:00
abstract::By design, the range of beam directions in conventional radiosurgery are constrained to an isocentric array. However, the recent introduction of robotic radiosurgery dramatically increases the flexibility of targeting, and as a consequence, beams need be neither coplanar nor isocentric. Such a nonisocentric design per...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2357020
更新日期:2006-11-01 00:00:00
abstract:PURPOSE:Ablative hyperthermia (>55 °C) has been used as a definitive treatment for accessible solid tumors not amenable to surgery, whereas mild hyperthermia (40-45 °C) has been shown effective as an adjuvant for both radiotherapy and chemotherapy. An optimal mild hyperthermia treatment is spatially accurate, with prec...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4769116
更新日期:2013-01-01 00:00:00
abstract:PURPOSE:This paper provides a comparison between a fast, commercial, in-patient Monte Carlo dose calculation algorithm (GPUMCD) and geant4. It also evaluates the dosimetric impact of the application of an external 1.5 T magnetic field. METHODS:A stand-alone version of the Elekta™ GPUMCD algorithm, to be used within th...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4939808
更新日期:2016-02-01 00:00:00
abstract:PURPOSE:High dose rate (HDR) brachytherapy is a radiation treatment technique capable of delivering large dose rates to the tumor. Radiation is delivered using remote afterloaders to drive highly active sources (commonly (192)Ir with an air KERMA strength range between 20,000 and 40,000 U, where 1 U = 1 μGy m(2)/h in a...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4822736
更新日期:2013-11-01 00:00:00
abstract:PURPOSE:To show that Cherenkov emission is generated by external radiotherapy beam in tissue, and could serve as optical source to excite an oxygen sensitive phosphor, Oxyphor G4, within tissue. The intensity and lifetime of the phosphorescence was measured with a time-gated system and reveals the oxygenation levels in...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4734811
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:Current respiratory motion monitoring devices used for motion synchronization in medical imaging and radiotherapy provide either 1D respiratory signal over a specific region or 3D information based on few external or internal markers. On the other hand, newer technology may offer the potential to monitor the en...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3589131
更新日期:2011-06-01 00:00:00
abstract::A comprehensive performance testing program is an essential ingredient of high-quality single-photon emission computed tomography (SPECT). Many of the procedures previously published are complicated, time consuming, or require a special testing environment. This Task Group developed a protocol for evaluating SPECT ima...
journal_title:Medical physics
pub_type: 指南,杂志文章
doi:10.1118/1.597605
更新日期:1995-04-01 00:00:00
abstract:PURPOSE:A dosimetry evaluation model for treatment planning of esophageal radiation therapy is developed using a deep learning model. The model predicts dose volume histogram (DVH) from distance to target histogram (DTH) based on stacked de-noise auto-encoder (SDAE) and one-dimensional convolutional network (1D-CN). M...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14434
更新日期:2020-10-01 00:00:00
abstract::The Los Alamos code MCNP4A (Monte Carlo N-Particle version 4A) is currently used to simulate a variety of problems ranging from nuclear reactor analysis to boron neutron capture therapy. A graphical user interface has been developed that automatically sets up the MCNP4A geometry and radiation source requirements for a...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598167
更新日期:1998-01-01 00:00:00
abstract::Transmission imaging is receiving increasing attention in SPECT due to the need to compensate for nonuniform attenuation in cardiac-chest SPECT. The quality of a transmission image has an important effect on the measured attenuation distribution. To improve image quality, knowledge of the performance characteristics o...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596752
更新日期:1992-09-01 00:00:00
abstract::A tomographic attachment was designed and developed that attaches to our existing simulator. The film tomograms obtained with the aid of this device exhibit very low geometrical distortion and good contrast and resolution for the objects used in this investigation. In addition, our results to date show that adjacent a...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594662
更新日期:1980-03-01 00:00:00
abstract::The ability of Leksell GammaPlan to perform stereotactic space localizations with image sets where there is misalignment of the patient's head (stereotactic frame and fiducial apparatus) relative to the computed tomography (CT) scanner coordinate system was studied. Misalignment is sometimes necessary for patient comf...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2179751
更新日期:2006-04-01 00:00:00
abstract:PURPOSE:To measure the calibration curves of EBT3 dosimetry films in photon and proton beams and to quantify the related uncertainties from one beam type to another. METHODS:EBT3 Gafchromic films have similar properties than EBT2 with a symmetric construction and a matte polyester substrate to prevent Newton's ring ar...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735176
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:Osteoporosis is a common bone disease associated with increased risk of low-trauma fractures leading to substantial morbidity, mortality, and financial costs. Clinically, osteoporosis is defined by low bone mineral density (BMD); however, increasing evidence suggests that trabecular bone (TB) microarchitectural...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4928481
更新日期:2015-09-01 00:00:00
abstract:PURPOSE:To demonstrate the feasibility of compressed sensing (CS) to accelerate the acquisition of hyperpolarized (HP) 129 Xe multi-b diffusion MRI for quantitative assessments of lung microstructural morphometry. METHODS:Six healthy subjects and six chronic obstructive pulmonary disease (COPD) subjects underwent HP 1...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12944
更新日期:2018-07-01 00:00:00
abstract::The dissemination of scientific advances has changed little since the first peer-reviewed journal was published in 1665 - that is, until this past decade. The print journal, delivered by mail and stored on office shelves and in library reading rooms around the world, has been transformed by immediate, on-demand access...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4736173
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:New preclinical image-guided irradiators and treatment planning systems represent a huge progress in radiobiology. Nevertheless, quality control of preclinical treatments is not as advanced as in clinical radiotherapy and in vivo dosimetry is less developed. In this study, we evaluate the use of a scintillating...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13903
更新日期:2020-01-01 00:00:00
abstract:PURPOSE:The aim of this study was to assess the suitability of Gafchromic EBT3 films for reference dose measurements in the beam of a prototype high dose-per-pulse linear accelerator (linac), capable of delivering electron beams with a mean dose-rate (Ḋm ) ranging from 0.07 to 3000 Gy/s and a dose-rate in pulse (Ḋp ) o...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12066
更新日期:2017-02-01 00:00:00
abstract:PURPOSE:Until recently the treatment verification for patients undergoing fast neutron therapy at our facility was accomplished through a combination of neutron beam portal films aligned with a graticule mounted on an orthronormal x-ray tube. To eliminate uncertainty with respect to the relative positions of the x-ray ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4734951
更新日期:2012-06-01 00:00:00
abstract::Mammography is the most effective method for breast cancer screening available today. However, the low positive predictive value of breast biopsy resulting from mammogram interpretation leads to approximately 70% unnecessary biopsies with benign outcomes. To reduce the high number of unnecessary breast biopsies, sever...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2786864
更新日期:2007-11-01 00:00:00
abstract:PURPOSE:In photon radiotherapy, respiratory-induced target motion can be accounted for by internal target volumes (ITV) or mid-ventilation target volumes (midV) defined on the basis of four-dimensional computed tomography (4D-CT). Intrinsic limitations of these approaches can result in target volumes that are not repre...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14023
更新日期:2020-04-01 00:00:00
abstract::Positron emission tomography (PET) is increasingly considered as an effective imaging method to support several stages of radiation therapy. The combined usage of functional and morphological imaging in state-of-the-art PET/CT scanners is rapidly emerging to support the treatment planning process in terms of improved ...
journal_title:Medical physics
pub_type: 杂志文章,评审
doi:10.1118/1.4935869
更新日期:2015-12-01 00:00:00
abstract:PURPOSE:The purpose of this work was to examine the suitability of VIPARnd polymer gel-9.4 T magnetic resonance microimaging system for high spatial resolution dose distribution measurements. METHODS:The VIPARnd samples (3 cm in outside diameter and 12 cm in height) were exposed to ionizing radiation by using a linear...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14186
更新日期:2020-08-01 00:00:00