Ultrasound contrast-detail analysis: a preliminary study in human observer performance.

Abstract:

:Results of a human observer performance study using a new ultrasound contrast-detail (CD) phantom are reported. The new phantom allows estimates of the fundamental statistical uncertainties involved in CD analysis. Results of these experiments show that observers generally considered to be "trained" require experience at the specific task of low-contrast target detection under signal known exactly (SKE) conditions, and that observers require an orientation period at the beginning of each observation session to obtain stable responses. The results obtained in this study can be used to estimate the number of independent images, observers, and repeat observation sessions required for a desired uncertainty in CD curves, and show that 10% fractional standard deviations are obtainable with modest observer effort.

journal_name

Med Phys

journal_title

Medical physics

authors

Hall TJ,Insana MF,Soller NM,Harrison LA

doi

10.1118/1.597147

subject

Has Abstract

pub_date

1993-01-01 00:00:00

pages

117-27

issue

1

eissn

0094-2405

issn

2473-4209

journal_volume

20

pub_type

杂志文章
  • Carpal tunnel syndrome diagnosis by a self-normalization process and ultrasound compound imaging.

    abstract:PURPOSE:Carpal tunnel syndrome (CTS) is the common entrapment neuropathy that occurs due to compression of the median nerve at the wrist. Ultrasound images have been used to highlight anatomical variants of the median nerve, and CTS is thought to be associated to enlargement of the cross-sectional area (CSA) of the med...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4767754

    authors: Liao YY,Wu CC,Kuo TT,Chen JP,Hsu YW,Yeh CK

    更新日期:2012-12-01 00:00:00

  • Imaging of radiation dose by visible color development in ferrous-agarose-xylenol orange gels.

    abstract::Imaging of radiation dose distribution in gel phantoms by magnetic resonance techniques has previously been reported. In this paper a method of producing gels in which the distributions of radiation dose can also be visualized as a color change is reported. The color developed depends qualitatively and quantitatively ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596676

    authors: Appleby A,Leghrouz A

    更新日期:1991-03-01 00:00:00

  • SU-C-218-06: Evaluation of a CT-Based, Semi-Automated Lung Mass Estimation Method Under Varying Acquisition Conditions.

    abstract:PURPOSE:To evaluate a simple, semi-automated lung mass estimation method on CT scans from a variety of acquisition techniques for mass correction of MIRD dose estimates. METHODS:CT scans from ten patients undergoing stereotactic body radiation therapy treatment planning on a GE DST PET/CT scanner were analyzed retrosp...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734654

    authors: Busse N,Erwin W,Pan T

    更新日期:2012-06-01 00:00:00

  • Accuracy of respiratory motion measurement of 4D-MRI: A comparison between cine and sequential acquisition.

    abstract:PURPOSE:The authors have recently developed a cine-mode T2*/T1-weighted 4D-MRI technique and a sequential-mode T2-weighted 4D-MRI technique for imaging respiratory motion. This study aims at investigating which 4D-MRI image acquisition mode, cine or sequential, provides more accurate measurement of organ motion during ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4938066

    authors: Liu Y,Yin FF,Rhee D,Cai J

    更新日期:2016-01-01 00:00:00

  • A Monte Carlo study on the collimation of pencil beam scanning proton therapy beams.

    abstract:PURPOSE:The lateral edge of a proton therapy beam is commonly used to achieve conformality to the treatment volume where critical structures reside close to the target. However, when treating shallow depths, the lateral edge of a pencil beam scanning (PBS) system may be broader than that of a double scattered (DS) syst...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4941957

    authors: Charlwood FC,Aitkenhead AH,Mackay RI

    更新日期:2016-03-01 00:00:00

  • Characterization of statistical prior image constrained compressed sensing (PICCS): II. Application to dose reduction.

    abstract:PURPOSE:The ionizing radiation imparted to patients during computed tomography exams is raising concerns. This paper studies the performance of a scheme called dose reduction using prior image constrained compressed sensing (DR-PICCS). The purpose of this study is to characterize the effects of a statistical model of x...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4773866

    authors: Lauzier PT,Chen GH

    更新日期:2013-02-01 00:00:00

  • Errors in cerebral blood flow determinations by xenon-enhanced computed tomography due to estimation of arterial xenon concentrations.

    abstract::Errors in the determination of xenon concentrations in arterial blood during inhalation of xenon-oxygen mixtures are used to assess errors in the derivation of regional cerebral blood flow by the xenon-enhanced computed tomography (CT) method. The results of this study indicate that approximating the arterial buildup ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596051

    authors: Good WF,Gur D,Yonas H,Herron JM

    更新日期:1987-05-01 00:00:00

  • A field-shaping multi-well avalanche detector for direct conversion amorphous selenium.

    abstract:PURPOSE:A practical detector structure is proposed to achieve stable avalanche multiplication gain in direct-conversion amorphous selenium radiation detectors. METHODS:The detector structure is referred to as a field-shaping multi-well avalanche detector. Stable avalanche multiplication gain is achieved by eliminating...

    journal_title:Medical physics

    pub_type: 信件

    doi:10.1118/1.4769110

    authors: Goldan AH,Zhao W

    更新日期:2013-01-01 00:00:00

  • Compensator quality control with an amorphous silicon EPID.

    abstract::The calibration and quality control of compensators is conventionally performed with an ion chamber in a water-equivalent phantom. In our center, the compensator factor and four off-axis fluence ratios are measured to verify the central axis beam modulation and orientation of the compensator. Here we report the invest...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1584040

    authors: Menon GV,Sloboda RS

    更新日期:2003-07-01 00:00:00

  • A dosimetry review system for cooperative group research.

    abstract::The validity of conclusions drawn from multi-institutional radiotherapy studies is dependent upon the degree to which participating hospitals adhere to study requirements. A major effort undertaken by the Quality Assurance Review Center (QARC) assesses whether or not patient data which are deemed evaluable actually co...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595221

    authors: Reinstein LE,McShan D,Glicksman AS

    更新日期:1982-03-01 00:00:00

  • Technical note: patient-specific quality assurance methods for TomoDirect(TM) whole breast treatment delivery.

    abstract:PURPOSE:To investigate the feasibility of implementing a novel approach for patient-specific QA of TomoDirect(TM) whole breast treatment. METHODS:The most currently used TomoTherapy DQA method, consisting in the verification of the 2D dose distribution in a coronal or sagittal plane of the Cheese Phantom by means of g...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4722967

    authors: Catuzzo P,Zenone F,Aimonetto S,Peruzzo A,Casanova Borca V,Pasquino M,Franco P,La Porta MR,Ricardi U,Tofani S

    更新日期:2012-07-01 00:00:00

  • Pulmonary embolism in pregnant patients: Assessing organ dose to pregnant phantom and its fetus during lung imaging.

    abstract:PURPOSE:The purpose of this study was to provide updated radiation dose from diagnostic exams performed for pregnant patients suspected of pulmonary embolism (PE) using the recently developed BREP phantoms of pregnant woman and the fetus. Also to challenge the validity of current recommendations suggest that ventilatio...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12558

    authors: Rafat Motavalli L,Hoseinian Azghadi E,Miri Hakimabad H,Akhlaghi P

    更新日期:2017-11-01 00:00:00

  • SU-E-T-203: Development of a QA Software Tool for Automatic Verification of Plan Data Transfer and Delivery.

    abstract:PURPOSE:Consistency verification between the data from treatment planning system (TPS), record and verification system (R&V), and delivered recorder with visual inspection is time consuming and subject to human error. The purpose of this work is to develop a software tool to automatically perform such verifications. M...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735263

    authors: Chen G,Li X

    更新日期:2012-06-01 00:00:00

  • Effects of protocol and obesity on dose conversion factors in adult body CT.

    abstract:PURPOSE:In computed tomography (CT), organ dose, effective dose, and risk index can be estimated from volume-weighted CT dose index (CTDI(vol)) or dose-length product (DLP) using conversion coefficients. Studies have investigated how these coefficients vary across scanner models, scan parameters, and patient size. Howe...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4754584

    authors: Li X,Samei E,Williams CH,Segars WP,Tward DJ,Miller MI,Ratnanather JT,Paulson EK,Frush DP

    更新日期:2012-11-01 00:00:00

  • Intensity-modulation radiotherapy using independent collimators: an algorithm study.

    abstract::The purpose of this work is to investigate algorithms for the delivery of intensity-modulated fields using independent collimators (IC). Two heuristic algorithms are proposed to calculate jaw-setting sequences for arbitrary 2D intensity distributions. The first algorithm is based on searching the whole intensity matri...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598794

    authors: Dai JR,Hu YM

    更新日期:1999-12-01 00:00:00

  • The effect of dose calculation uncertainty on the evaluation of radiotherapy plans.

    abstract::Monte Carlo dose calculations will potentially reduce systematic errors that may be present in currently used dose calculation algorithms. However, Monte Carlo calculations inherently contain random errors, or statistical uncertainty, the level of which decreases inversely with the square root of computation time. Our...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598916

    authors: Keall PJ,Siebers JV,Jeraj R,Mohan R

    更新日期:2000-03-01 00:00:00

  • Task Group 284 Report: Magnetic Resonance Imaging Simulation in Radiotherapy: Considerations for Clinical Implementation, Optimization, and Quality Assurance.

    abstract::The use of dedicated magnetic resonance simulation (MR-SIM) platforms in Radiation Oncology has expanded rapidly, introducing new equipment and functionality with the overall goal of improving the accuracy of radiation treatment planning. However, this emerging technology presents a new set of challenges that need to ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14695

    authors: Glide-Hurst CK,Paulson ES,McGee K,Tyagi N,Hu Y,Balter J,Bayouth J

    更新日期:2021-01-01 00:00:00

  • Dose optimization in pediatric cardiac x-ray imaging.

    abstract:PURPOSE:The aim of this research was to explore x-ray beam parameters with intent to optimize pediatric x-ray settings in the cardiac catheterization laboratory. This study examined the effects of peak x-ray tube voltage (kVp) and of copper (Cu) x-ray beam filtration independently on the image quality to dose balance f...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3488911

    authors: Gislason AJ,Davies AG,Cowen AR

    更新日期:2010-10-01 00:00:00

  • Sci-Thurs PM: Delivery-03: Optical imaging of microscopic radiation dose gradients using a digital microscope.

    abstract::Using superior localization and immobilization methods, stereotactic radiosurgery is capable of delivering spheres of dose as small as a few millimetres in diameter to intracranial targets. For targets abutting critical structures, the most conformal treatments minimize adverse radiation side effects and it is importa...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2965910

    authors: Keller BM,Peressotti C,Pignol JP

    更新日期:2008-07-01 00:00:00

  • Re-examining TG-142 recommendations in light of modern techniques for linear accelerator based radiosurgery.

    abstract:PURPOSE:The recent development of multifocal stereotactic radiosurgery (SRS) using a single isocenter volumetric modulated arc theory (VMAT) technique warrants a re-examination of the quality assurance (QA) tolerances for routine mechanical QA recommended by the American Association of Physicists in Medicine Task Group...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4962471

    authors: Faught AM,Trager M,Yin FF,Kirkpatrick J,Adamson J

    更新日期:2016-10-01 00:00:00

  • Automated segmentation of anatomic regions in chest radiographs using an adaptive-sized hybrid neural network.

    abstract::The purposes of this research are to investigate the effectiveness of our novel image features for segmentation of anatomic regions such as the lungs and the mediastinum in chest radiographs and to develop an automatic computerized method for image processing. A total of 85 screening chest radiographs from Johns Hopki...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598277

    authors: Tsujii O,Freedman MT,Mun SK

    更新日期:1998-06-01 00:00:00

  • Technical note: the calibration of 90Y-labeled SIR-Spheres using a nondestructive spectroscopic assay.

    abstract::90Y-labeled SIR-Spheres are currently used to treat patients with hepatic metastases secondary to colorectal adenocarcinoma. In general, the prescribed activity is based on empirical data collected during clinical trials. The activity of the source vial is labeled by the manufacturer as 3.0 GBq +/- 10% and is not inde...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2889621

    authors: Selwyn R,Micka J,DeWerd L,Nickles R,Thomadsen B

    更新日期:2008-04-01 00:00:00

  • Speckle contrast diffuse correlation tomography of complex turbid medium flow.

    abstract:PURPOSE:Developed herein is a three-dimensional (3D) flow contrast imaging system leveraging advancements in the extension of laser speckle contrast imaging theories to deep tissues along with our recently developed finite-element diffuse correlation tomography (DCT) reconstruction scheme. This technique, termed speckl...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4922206

    authors: Huang C,Irwin D,Lin Y,Shang Y,He L,Kong W,Luo J,Yu G

    更新日期:2015-07-01 00:00:00

  • Assessment of a new multileaf collimator concept using GEANT4 Monte Carlo simulations.

    abstract::The aim of the work was to investigate in advance the dosimetric properties of a new multileaf collimator (MLC) concept with the help of Monte Carlo (MC) simulations prior to the production of a prototype. The geometrical design of the MLC was implemented in the MC code GEANT4. For the simulation of a 6 MV treatment b...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2181298

    authors: Tacke MB,Szymanowski H,Oelfke U,Schulze C,Nuss S,Wehrwein E,Leidenberger S

    更新日期:2006-04-01 00:00:00

  • The importance of computed tomography slice thickness in radiographic patient positioning for radiosurgery.

    abstract::A new radiographic patient positioning technique developed for radiosurgery has been analyzed to show the effect of computed tomography (CT) slice thickness on the precision of target localization during treatment. The positioning technique establishes the pose of the patient's anatomy during treatment by comparing tr...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598500

    authors: Murphy MJ

    更新日期:1999-02-01 00:00:00

  • Four-dimensional intensity-modulated radiation therapy planning for dynamic tracking using a direct aperture deformation (DAD) method.

    abstract:PURPOSE:Planning for the delivery of intensity-modulated radiation therapy (IMRT) to a moving target, referred to as four-dimensional (4D) IMRT planning, is a crucial step for achieving the treatment objectives for sites that move during treatment delivery. The authors proposed a simplistic method that accounts for bot...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3319498

    authors: Gui M,Feng Y,Yi B,Dhople AA,Yu C

    更新日期:2010-05-01 00:00:00

  • Basic imaging properties of a computed radiographic system with photostimulable phosphors.

    abstract::We measured the characteristic curve, modulation transfer function (MTF), and the Wiener spectrum of a commercially available computed radiographic (CR) system with photostimulable phosphor plate (imaging plate, IP). The characteristic curve (system response) obtained by an inverse-square x-ray sensitometry showed a w...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596402

    authors: Fujita H,Ueda K,Morishita J,Fujikawa T,Ohtsuka A,Sai T

    更新日期:1989-01-01 00:00:00

  • Technical Note: Experimental determination of the effective point of measurement of two cylindrical ionization chambers in a clinical proton beam.

    abstract:PURPOSE:IAEA TRS-398 notes that cylindrical ionization chambers are preferred for reference proton dosimetry. If a cylindrical ionization chamber is used in a phantom to measure the dose as a function of depth, the effective point of measurement (EPOM) must be taken into account. IAEA TRS-398 recommends a displacement ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4921617

    authors: Sugama Y,Nishio T,Onishi H

    更新日期:2015-07-01 00:00:00

  • Urinary bladder cancer staging in CT urography using machine learning.

    abstract:PURPOSE:To evaluate the feasibility of using an objective computer-aided system to assess bladder cancer stage in CT Urography (CTU). MATERIALS AND METHODS:A dataset consisting of 84 bladder cancer lesions from 76 CTU cases was used to develop the computerized system for bladder cancer staging based on machine learnin...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12510

    authors: Garapati SS,Hadjiiski L,Cha KH,Chan HP,Caoili EM,Cohan RH,Weizer A,Alva A,Paramagul C,Wei J,Zhou C

    更新日期:2017-11-01 00:00:00

  • A consistent set of neutron kerma coefficients from thermal to 150 MeV for biologically important materials.

    abstract::Neutron cross sections for nonelastic and elastic reactions on a range of elements have been evaluated for incident energies up to 150 MeV. These cross sections agree well with experimental cross section data for charged-particle production as well as neutron and photon production. Therefore they can be used to determ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598601

    authors: Chadwick MB,Barschall HH,Caswell RS,DeLuca PM,Hale GM,Jones DT,MacFarlane RE,Meulders JP,Schuhmacher H,Schrewe UJ,Wambersie A,Young PG

    更新日期:1999-06-01 00:00:00