Noninvasive cardiac arrhythmia ablation with particle beams.

Abstract:

:Cardiac arrhythmias are a major health burden, associated with reduced quality of life and substantial morbidity and mortality. Current therapy includes moderately effective medication and catheter-based ablation of arrhythmogenic substrates in the heart. Catheter interventions frequently have to be repeated due to recurrent arrhythmia, can have rare but severe side-effects and are less suited especially for potentially lethal left ventricular tachycardia. Noninvasive alternatives are therefore warranted. Photon and ion beam radiotherapy has been studied in animal models and first patient cases have been reported using photons. Ion beams might offer the possibility to greatly reduce dose to surrounding healthy tissue, including critical cardiac substructures. Based on a recently conducted animal study, we report advantages and disadvantages of 4D-ion beam therapy, and strategies necessary for a clinical transition. Motion management of both respiration and heartbeat are discussed, as well as range uncertainty resulting from both regular motion and interfractional anatomic changes. Image guidance both in 3D and 4D has to be employed for a safe irradiation, but also population-based data on motion variability and time behavior of interfractional changes are necessary. Range verification could play a crucial role at least during development of clinical protocols. For clinical realization, it appears necessary to suppress or conformally mitigate the large respiratory motion to avoid normal tissue complications. Cardiac motion has to be incorporated into treatment planning, either through adequate range-considering internal margins or through more conformal strategies such as ECG-based gating or even 4D-optimization. The latter strategies would necessitate online 4D image guidance.

journal_name

Med Phys

journal_title

Medical physics

authors

Graeff C,Bert C

doi

10.1002/mp.12595

subject

Has Abstract

pub_date

2018-11-01 00:00:00

pages

e1024-e1035

issue

11

eissn

0094-2405

issn

2473-4209

journal_volume

45

pub_type

杂志文章,评审
  • Improved motion-compensated image reconstruction for PET using sensitivity correction per respiratory gate and an approximate tube-of-response backprojector.

    abstract:PURPOSE:One limitation of positron emission tomography (PET) imaging of the torso is patient motion. Motion-compensated image reconstruction (MCIR) is one method employed to reduce the deleterious effects of motion. Existing MCIR algorithms use a single sensitivity correction term, which provides inexact normalization ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3611041

    authors: Dikaios N,Fryer TD

    更新日期:2011-09-01 00:00:00

  • An accelerated threshold-based back-projection algorithm for compton camera image reconstruction.

    abstract:PURPOSE:Compton camera imaging (CCI) systems are currently under investigation for radiotherapy dose reconstruction and verification. The ability of such a system to provide real-time images during dose delivery will be limited by the computational speed of the image reconstruction algorithm. In this work, the authors ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3519873

    authors: Mundy DW,Herman MG

    更新日期:2011-01-01 00:00:00

  • Broad line quantitative chemical shift spectroscopy.

    abstract::Proton NMR spectroscopy was applied to quantitate the measurement of total body water/fat distributions in vivo. A special MR protocol was developed to excite a thick slab of tissue and display the magnitude NMR spectrum of the collected response signal. Very short echo time TE (8 ms) and long repetition time TR (4000...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596935

    authors: Sobol WT,Elster AD,Hinson WH,Chwals WJ

    更新日期:1992-01-01 00:00:00

  • Characteristics of metal-plate/film detectors at therapy energies. II. Detective quantum efficiency.

    abstract::Noise power spectrum (NPS) and detective quantum efficiency (DQE) for metal-plate/film portal detectors are reported for the Co-60 and Linac 10 MV spectra. The detectors consist of a double-emulsion portal film secured between plates of aluminum, copper, brass, or lead. The NPS was found to be independent of the detec...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598437

    authors: Falco T,Fallone BG

    更新日期:1998-12-01 00:00:00

  • Heating patterns of microwave applicators in inhomogeneous arm and thigh phantoms.

    abstract::Heating rate (HR) patterns in cylindrical structures were studied with inhomogeneous limb phantoms. These phantoms, arm and thigh models consisting of fat, bone, and muscle material, were heated with Clini-Therm L, M, and MS applicators at 915 MHz. The thigh model is 18 cm in diameter with 2.65-cm-thick fat on the out...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596627

    authors: Chou CK,McDougall JA,Chan KW,Luk KH

    更新日期:1991-11-01 00:00:00

  • A double mirror W/C multilayer monochromator for radiation biology applications.

    abstract::A double-mirror multilayer monochromator was developed for the purpose of irradiating live cell cultures at the Synchrotron Radiation Center, University of Wisconsin-Madison. The monochromator is designed for the soft x-ray region with photon energies between 270 and 2400 eV. Multilayer mirrors with 55 bilayers of W/C...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598259

    authors: MacKay JF,Pearson DW,Nelms BE,DeLuca PM Jr,Gould MN,Lagally MG

    更新日期:1998-05-01 00:00:00

  • Transrectal electrical impedance tomography of the prostate: spatially coregistered pathological findings for prostate cancer detection.

    abstract:PURPOSE:Prostate cancer ranks as one of the most common malignancies and currently represents the second leading cancer-specific cause of death in men. The current use of single modality transrectal ultrasound (TRUS) for biopsy guidance has a limited sensitivity and specificity for accurately identifying cancerous lesi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4803498

    authors: Wan Y,Borsic A,Heaney J,Seigne J,Schned A,Baker M,Wason S,Hartov A,Halter R

    更新日期:2013-06-01 00:00:00

  • Three-dimensional x-ray fluorescence mapping of a gold nanoparticle-loaded phantom.

    abstract:PURPOSE:X-ray fluorescence (XRF) is a promising technique with sufficient specificity and sensitivity for identifying and quantifying features in small samples containing high atomic number (Z) materials such as iodine, gadolinium, and gold. In this study, the feasibility of applying XRF to early breast cancer diagnosi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4863510

    authors: Ren L,Wu D,Li Y,Wang G,Wu X,Liu H

    更新日期:2014-03-01 00:00:00

  • Automated detection of pulmonary nodules in PET/CT images: Ensemble false-positive reduction using a convolutional neural network technique.

    abstract:PURPOSE:Automated detection of solitary pulmonary nodules using positron emission tomography (PET) and computed tomography (CT) images shows good sensitivity; however, it is difficult to detect nodules in contact with normal organs, and additional efforts are needed so that the number of false positives (FPs) can be fu...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4948498

    authors: Teramoto A,Fujita H,Yamamuro O,Tamaki T

    更新日期:2016-06-01 00:00:00

  • Anisotropy functions for 103Pd, 125I, and 192Ir interstitial brachytherapy sources.

    abstract::Anisotropy of dose distributions around 103Pd, 125I, and 192Ir sources for interstitial brachytherapy was examined. Dose rates around 125I models 6702 and 6711 and 192Ir sources were measured using lithium fluoride thermoluminescence dosimeters (LiF TLDs) in a water-equivalent, solid phantom. From these measured data ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597110

    authors: Nath R,Meigooni AS,Muench P,Melillo A

    更新日期:1993-09-01 00:00:00

  • Dependence with air density of the response of the PTW SourceCheck ionization chamber for low energy brachytherapy sources.

    abstract:PURPOSE:Air-communicating well ionization chambers are commonly used to assess air kerma strength of sources used in brachytherapy. The signal produced is supposed to be proportional to the air density within the chamber and, therefore, a density-independent air kerma strength is obtained when the measurement is correc...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4831757

    authors: Tornero-López AM,Guirado D,Perez-Calatayud J,Ruiz-Arrebola S,Simancas F,Gazdic-Santic M,Lallena AM

    更新日期:2013-12-01 00:00:00

  • High resolution digital autoradiographic and dosimetric analysis of heterogeneous radioactivity distribution in xenografted prostate tumors.

    abstract:PURPOSE:The first main aim of this study was to illustrate the absorbed dose rate distribution from 177Lu in sections of xenografted prostate cancer (PCa) tumors using high resolution digital autoradiography (DAR) and compare it with hypothetical identical radioactivity distributions of 90Y or 7 MeV alpha-particles. Th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4967877

    authors: Timmermand OV,Nilsson J,Strand SE,Elgqvist J

    更新日期:2016-12-01 00:00:00

  • Poster - Thur Eve - 23: Statistical analysis and verification of the percentage depth dose calculation based on the tissue maximum ratio in external beam radiotherapy.

    abstract::The aim of this study is to perform a statistical analysis to verify the calculated percentage depth dose (PDD) based on the tissue maximum ratio (TMR) with the PDD measurements taken in water. 6 and 15 MV photon beams produced by a Varian linear 2100 C/D accelerator were used. PDDs and TMRs were measured at various d...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4740131

    authors: Isa M,Iqbal K,Afzal M,Buzdar S,Chow J

    更新日期:2012-07-01 00:00:00

  • X-ray imaging with amorphous selenium: X-ray to charge conversion gain and avalanche multiplication gain.

    abstract::Fluoroscopy is a low dose imaging technique. As such, a very sensitive detector is required to create images of good quality. Present day flat panel active matrix read out systems introduce an amount of noise that inhibits present direct and indirect methods from producing optimal quality images at fluoroscopic exposu...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1513157

    authors: Hunt DC,Kirby SS,Rowlands JA

    更新日期:2002-11-01 00:00:00

  • Measurement of surface dose in an MR-Linac with optically stimulated luminescence dosimeters for IMRT beam geometries.

    abstract:PURPOSE:This study aims to measure the surface dose on an anthropomorphic phantom for intensity-modulated radiation therapy (IMRT) plans treated in a 1.5 T magnetic resonance (MR)-Linac. Previous studies have used Monte Carlo programs to simulate surface dose and have recognized high surface dose as a potential limitin...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14185

    authors: Lim-Reinders S,Keller BM,Sahgal A,Chugh B,Kim A

    更新日期:2020-07-01 00:00:00

  • Soft-tissue detectability in cone-beam CT: evaluation by 2AFC tests in relation to physical performance metrics.

    abstract::Soft-tissue detectability in cone-beam computed tomography (CBCT) was evaluated via two-alternative forced-choice (2AFC) tests. Investigations included the dependence of detectability on radiation dose, the influence of the asymmetric three-dimensional (3D) noise-power spectrum (NPS) in axial and sagittal or coronal p...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2790586

    authors: Tward DJ,Siewerdsen JH,Daly MJ,Richard S,Moseley DJ,Jaffray DA,Paul NS

    更新日期:2007-11-01 00:00:00

  • High dose-per-pulse electron beam dosimetry: Usability and dose-rate independence of EBT3 Gafchromic films.

    abstract:PURPOSE:The aim of this study was to assess the suitability of Gafchromic EBT3 films for reference dose measurements in the beam of a prototype high dose-per-pulse linear accelerator (linac), capable of delivering electron beams with a mean dose-rate (Ḋm ) ranging from 0.07 to 3000 Gy/s and a dose-rate in pulse (Ḋp ) o...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12066

    authors: Jaccard M,Petersson K,Buchillier T,Germond JF,Durán MT,Vozenin MC,Bourhis J,Bochud FO,Bailat C

    更新日期:2017-02-01 00:00:00

  • An analysis of the mechanical parameters used for finite element compression of a high-resolution 3D breast phantom.

    abstract:PURPOSE:The authors previously introduced a methodology to generate a realistic three-dimensional (3D), high-resolution, computer-simulated breast phantom based on empirical data. One of the key components of such a phantom is that it provides a means to produce a realistic simulation of clinical breast compression. In...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3637500

    authors: Hsu CM,Palmeri ML,Segars WP,Veress AI,Dobbins JT 3rd

    更新日期:2011-10-01 00:00:00

  • Ethics and professionalism in medical physics: a survey of AAPM members.

    abstract:PURPOSE:To assess current education, practices, attitudes, and perceptions pertaining to ethics and professionalism in medical physics. METHODS:A link to a web-based survey was distributed to the American Association of Physicists in Medicine (AAPM) e-mail membership list, with a follow-up e-mail sent two weeks later....

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4797463

    authors: Ozturk N,Armato SG 3rd,Giger ML,Serago CF,Ross LF

    更新日期:2013-04-01 00:00:00

  • WE-E-BRCD-01: SBRT Treatment Planning: Practical Considerations.

    abstract::Stereotactic Body Radiation Therapy (SBRT) is being increasingly used in the radiation oncology community to treat tumors in extra-cranial sites such as spine, lung, liver, pancreas and prostate. There are well established RTOG protocols (e.g. RTOG 0631 for spine, RTOG 0813 and 0915 for lung and RTOG 0438 for liver) t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4736142

    authors: Hong L

    更新日期:2012-06-01 00:00:00

  • Automated segmentation of anatomic regions in chest radiographs using an adaptive-sized hybrid neural network.

    abstract::The purposes of this research are to investigate the effectiveness of our novel image features for segmentation of anatomic regions such as the lungs and the mediastinum in chest radiographs and to develop an automatic computerized method for image processing. A total of 85 screening chest radiographs from Johns Hopki...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598277

    authors: Tsujii O,Freedman MT,Mun SK

    更新日期:1998-06-01 00:00:00

  • Estimation of a photon energy spectrum for a computed tomography scanner.

    abstract::Estimated photon energy spectra are derived from transmission measurements using aluminium, copper, and sodium iodide absorbers. Two spectral models are proposed. One is based on a previously published model that analyzes the electron's penetration into the anode, and the production and attenuation of bremsstrahlung p...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598159

    authors: Ruth C,Joseph PM

    更新日期:1997-05-01 00:00:00

  • Stereomammography: evaluation of depth perception using a virtual 3D cursor.

    abstract::We are evaluating the usefulness of stereomammography in improving breast cancer diagnosis. One area that we are investigating is whether the improved depth perception associated with stereomammography might be significantly enhanced with the use of a virtual 3D cursor. A study was performed to evaluate the accuracy o...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.599008

    authors: Goodsitt MM,Chan HP,Hadjiiski L

    更新日期:2000-06-01 00:00:00

  • An innovative digital imaging set-up allowing a low-dose approach to phase contrast applications in the medical field.

    abstract::Recently, new imaging modalities based on the detection of weak phase perturbations effects, among which are phase contrast and diffraction imaging, have been developed by several researchers. Due to their high sensitivity to weakly absorbing details, these techniques seem to be very promising for applications in the ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1388219

    authors: Olivo A,Arfelli F,Cantatore G,Longo R,Menk RH,Pani S,Prest M,Poropat P,Rigon L,Tromba G,Vallazza E,Castelli E

    更新日期:2001-08-01 00:00:00

  • Selecting beam weight and wedge filter on the basis of dose gradient analysis.

    abstract::This study proposes an algorithm for selecting beam weight, wedge angle, and wedge orientation for three-dimensional radiation therapy treatment planning. According to dose gradient analysis, the necessary and sufficient condition for achieving a homogeneous dose over the target volume is that the total vector sum of ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1286591

    authors: Dai J,Zhu Y

    更新日期:2000-08-01 00:00:00

  • A data-mining framework for large scale analysis of dose-outcome relationships in a database of irradiated head and neck cancer patients.

    abstract:PURPOSE:To develop a hypothesis-generating framework for automatic extraction of dose-outcome relationships from an in-house, analytic oncology database. METHODS:Dose-volume histograms (DVH) and clinical outcomes have been routinely stored to the authors' database for 684 head and neck cancer patients treated from 200...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4922686

    authors: Robertson SP,Quon H,Kiess AP,Moore JA,Yang W,Cheng Z,Afonso S,Allen M,Richardson M,Choflet A,Sharabi A,McNutt TR

    更新日期:2015-07-01 00:00:00

  • Novel dosimetric phantom for quality assurance of volumetric modulated arc therapy.

    abstract::The objective of this work is to assess the suitability and performance of a new dosimeter system with a novel geometry for the quality assurance (QA) of volumetric modulated arc therapy (VMAT). The new dosimeter system consists of a hollow cylinder (15 and 25 cm inner and outer diameters) with 124 diodes embedded in ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3117563

    authors: Létourneau D,Publicover J,Kozelka J,Moseley DJ,Jaffray DA

    更新日期:2009-05-01 00:00:00

  • Comparison of exposure standards in the mammography x-ray region.

    abstract::Direct comparisons of the National Institute of Standards and Technology's (NIST) Ritz 20 kV to 100 kV standard free-air ionization chamber and a portable variable-length free-air ionization chamber designed by the University of Wisconsin-Madison Accredited Dosimetry Calibration Laboratory (UW-ADCL) were made on NISTs...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598148

    authors: Coletti JG,Pearson DW,DeWerd LA,O'Brien CM,Lamperti PJ

    更新日期:1997-08-01 00:00:00

  • Evaluation of a deep learning-based computer-aided diagnosis system for distinguishing benign from malignant thyroid nodules in ultrasound images.

    abstract:PURPOSE:Computer-aided diagnosis (CAD) systems assist in solving subjective diagnosis problems that typically rely on personal experience. A CAD system has been developed to differentiate malignant thyroid nodules from benign thyroid nodules in ultrasound images based on deep learning methods. The diagnostic performanc...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14301

    authors: Sun C,Zhang Y,Chang Q,Liu T,Zhang S,Wang X,Guo Q,Yao J,Sun W,Niu L

    更新日期:2020-09-01 00:00:00

  • Electron backscatter corrections for parallel-plate chambers.

    abstract::The wall of an ionization chamber is commonly assumed to have a negligible effect on chamber response in electron beams. For cylindrical chambers with thin walls this assumption is valid. However, parallel-plate chambers commonly possess large mechanical supports which may affect chamber response in a manner not accou...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596165

    authors: Hunt MA,Kutcher GJ,Buffa A

    更新日期:1988-01-01 00:00:00