Abstract:
:Magnetic resonance (MR) measurements of relaxation times and diffusion coefficient in tissue have been demonstrated to be sensitive to biological changes induced by radiation therapy. We are currently using mouse models of human glioblastoma multiforme (GBM) to study tumour response to ionizing radiation by MRI at 9.4T. Utilizing conventional imaging techniques coupled with quantitative measurements of transverse relaxation time (T2) and apparent diffusion coefficient (ADC), we monitor changes during tumour growth and subsequent changes after single-fraction radiotherapy. In addition to tumour parameters, we have measured T2 and ADC in other structures that appear in the same transverse slices as tumour tissue. Here we report the measured distributions of T2 and ADC in tumour and in normal tissues that are likely to be encountered during MR imaging of tumour xenografts in mice, including liver, kidney, fat, skeletal muscle, spinal cord, and brain. Quantitative knowledge of these distributions in normal tissue is important in optimizing the sequences used for imaging of these tissues, and in optimizing continued measurements of T2 and ADC changes. Knowledge of parameter distributions in tumour is important because recent studies have suggested that the T2 and ADC responses after therapy may be the result of large shifts in smaller isolated pockets of tumour, rather than more moderate shifts in T2 and ADC over the whole tumour volume. These distributions provide a baseline measurement of typical distributions in advance of radiation therapy.
journal_name
Med Physjournal_title
Medical physicsauthors
Larocque M,Syme A,Fallone BGdoi
10.1118/1.2965985subject
Has Abstractpub_date
2008-07-01 00:00:00pages
3414issue
7Part3eissn
0094-2405issn
2473-4209journal_volume
35pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract:PURPOSE:The purpose of this study was to investigate the impact of transverse magnetic fields on the dose response of a radiophotoluminescent glass dosimeter (RGD) in megavoltage photon beams. METHODS:The RGD relative response (i.e., RGD dose per absorbed dose to water at the midpoint of the detector in the absence of...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14054
更新日期:2020-04-01 00:00:00
abstract:PURPOSE:Four-dimensional volumetric modulated arc therapy (4D VMAT) and four-dimensional intensity-modulated radiotherapy (4D IMRT) are developing radiation therapy treatment strategies designed to maximize dose conformality, minimize normal tissue dose, and deliver the treatment as efficiently as possible. The patient...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12778
更新日期:2018-04-01 00:00:00
abstract::Boron neutron capture therapy (BNCT) is an experimental type of radiotherapy, presently being used to treat glioblastoma and melanoma. To improve patient safety and to determine the radiobiological characteristics of the epithermal neutron beam of Finnish BNCT facility (FiR 1) dose-response studies were carried on the...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1517048
更新日期:2002-11-01 00:00:00
abstract::Proton NMR spectroscopy was applied to quantitate the measurement of total body water/fat distributions in vivo. A special MR protocol was developed to excite a thick slab of tissue and display the magnitude NMR spectrum of the collected response signal. Very short echo time TE (8 ms) and long repetition time TR (4000...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596935
更新日期:1992-01-01 00:00:00
abstract::Photoelectric-enhanced radiation therapy is a bimodal therapy, consisting of the administration of highly radiation-absorbing substances into the tumor area and localized regional irradiation with orthovoltage x-rays. Irradiation can be performed by a modified computed tomography (CT) unit equipped with an additional ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3125137
更新日期:2009-06-01 00:00:00
abstract::The widespread application of positron emission tomography (PET) in clinical oncology has driven this imaging technology into a number of new research and clinical arenas. Increasing numbers of patient scans have led to an urgent need for efficient data handling and the development of new image analysis techniques to ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2432404
更新日期:2007-02-01 00:00:00
abstract::Skeletal dosimetry based on microCT images of trabecular bone has recently been introduced to calculate the red bone marrow (RBM) and the bone surface cell (BSC) equivalent doses in human phantoms for external exposure to photons. In order to use the microCT images for skeletal dosimetry, spongiosa voxels in the skele...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3242266
更新日期:2009-11-01 00:00:00
abstract:PURPOSE:Accurate calculation of proton stopping power ratio (SPR) relative to water is crucial to proton therapy treatment planning, since SPR affects prediction of beam range. Current standard practice derives SPR using a single CT scan. Recent studies showed that dual-energy CT (DECT) offers advantages to accurately ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12796
更新日期:2018-04-01 00:00:00
abstract:PURPOSE:To develop a new design of an x-ray beam shaper for helical computed tomography (CT) that increases the dose utilization. METHODS:For typical reconstruction algorithms in helical CT, different data are utilized with different weights during back-projection. In particular, data of the outer detector rows, i.e.,...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3577766
更新日期:2011-07-01 00:00:00
abstract:PURPOSE:To analyze the noise performance of the edge illumination phase-based x-ray imaging technique when applying "single-shot" phase retrieval. The latter consists in applying a sample-specific low-pass filter to the raw data, leading to "hybrid" images in which phase and attenuation contrast are merged with each ot...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14366
更新日期:2020-09-01 00:00:00
abstract:PURPOSE:To evaluate a three-equation three-unknown dual-energy quantitative CT (DEQCT) technique for determining region specific variations in bone spongiosa composition for improved red marrow dose estimation in radionuclide therapy. METHODS:The DEQCT method was applied to 80/140 kVp images of patient-simulating lumb...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4870378
更新日期:2014-05-01 00:00:00
abstract::We measured the physical imaging performance of a 41 x 41 cm2 amorphous silicon flat panel detector designed for angiographic and R&F imaging applications using methods from the emerging IEC standard for the measurement of detective quantum efficiency (DQE) in digital radiographic detectors. Measurements on 12 product...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1609151
更新日期:2003-10-01 00:00:00
abstract:PURPOSE:Although robot-assisted coronary artery bypass grafting (RA-CABG) has gained more acceptance worldwide, its success still depends on the surgeon's experience and expertise, and the conversion rate to full sternotomy is in the order of 15%-25%. One of the reasons for conversion is poor pre-operative planning, wh...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3684958
更新日期:2012-03-01 00:00:00
abstract:PURPOSE:Accurate segmentation of lung and infection in COVID-19 computed tomography (CT) scans plays an important role in the quantitative management of patients. Most of the existing studies are based on large and private annotated datasets that are impractical to obtain from a single institution, especially when radi...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14676
更新日期:2020-12-23 00:00:00
abstract::Current methods for imaging joint motion are limited to either two-dimensional (2D) video fluoroscopy, or to animated motions from a series of static three-dimensional (3D) images. 3D movement patterns can be detected from biplane fluoroscopy images matched with computed tomography images. This involves several x-ray ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2000647
更新日期:2005-09-01 00:00:00
abstract::A beam stop technique was used to measure the densitometric scatter fractions under three regions of a humanoid chest phantom utilizing LaOBr and Gd2O2S screens. For these receptors, the scatter fractions under the lung and retrocardiac areas were 13%-36% lower than published values for CaWO4. In the mediastinal area,...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597041
更新日期:1993-03-01 00:00:00
abstract::The purpose of this paper is to develop a method that reduces the number of segments for intensity modulated arc therapy (IMAT) and intensity modulated radiotherapy (IMRT) for concave target volumes (TV). The aim was to utilize no more than two intensity levels per organ at risk (OAR) and to derive both optimal segmen...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1861161
更新日期:2005-03-01 00:00:00
abstract::Breast-conserving surgery combined with subsequent radiation therapy is a standard procedure in breast cancer treatment. The disadvantage of whole-breast beam irradiation is that it requires 20-25 treatment days, which is inconvenient for patients with limited mobility or who reside far from the treatment center. Howe...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3243865
更新日期:2009-11-01 00:00:00
abstract::The determination of the radiation exposure history of the population has become increasingly important in the study of the effects of low-level radiation. The present work was started to try to obtain an in vivo dosimeter that could give an indication of radiation exposure. Dental enamel is the only living tissue whi...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595768
更新日期:1985-05-01 00:00:00
abstract:PURPOSE:The small number of samples available for training and testing is often the limiting factor in finding the most effective features and designing an optimal computer-aided diagnosis (CAD) system. Training on a limited set of samples introduces bias and variance in the performance of a CAD system relative to that...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3284974
更新日期:2010-02-01 00:00:00
abstract::Direct comparisons of the National Institute of Standards and Technology's (NIST) Ritz 20 kV to 100 kV standard free-air ionization chamber and a portable variable-length free-air ionization chamber designed by the University of Wisconsin-Madison Accredited Dosimetry Calibration Laboratory (UW-ADCL) were made on NISTs...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598148
更新日期:1997-08-01 00:00:00
abstract:PURPOSE:The response of human cells to applied electrical signals depends on the cellular health status, because it is influenced by the composition and structure of the main cellular components. Therefore, electrical impedance-based techniques can be considered as sensitive tools to investigate healthy or disease stat...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14425
更新日期:2020-10-01 00:00:00
abstract::Monte Carlo simulation dosimetry is used to compare 169Yb to 192Ir for breast high dose rate (HDR) brachytherapy applications using multiple catheter implants. Results for bare point sources show that while 169Yb delivers a greater dose rate per unit air kerma strength at the radial distance range of interest to brach...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2392408
更新日期:2006-12-01 00:00:00
abstract:PURPOSE:New preclinical image-guided irradiators and treatment planning systems represent a huge progress in radiobiology. Nevertheless, quality control of preclinical treatments is not as advanced as in clinical radiotherapy and in vivo dosimetry is less developed. In this study, we evaluate the use of a scintillating...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13903
更新日期:2020-01-01 00:00:00
abstract::Compared with slice-by-slice approaches for SPECT reconstruction, three-dimensional iterative methods provide a more accurate physical model and an improved SPECT image. Clinical application of these methods, however, is limited primarily to their computational demands. This paper investigates the methods for approxim...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598030
更新日期:1997-09-01 00:00:00
abstract:PURPOSE:Formation of new blood vessels (angiogenesis) in response to hypoxia is a fundamental event in the process of tumor growth and metastatic dissemination. However, abnormalities in tumor neovasculature often induce increased interstitial pressure (IP) and further reduce oxygenation (pO2) of tumor cells. In radiot...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3615164
更新日期:2011-08-01 00:00:00
abstract:PURPOSE:High-dose-rate brachytherapy (HDR-BT) is a treatment option for malignant skin diseases compared to external beam radiation therapy, HDR-BT provides improved target coverage, better organ sparing, and has comparable treatment times. This is especially true for large clinical targets with complex topologies. To ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13975
更新日期:2020-03-01 00:00:00
abstract:PURPOSE:The response of alanine solid state dosimeters to ionizing radiation strongly depends on particle type and energy. Due to nuclear interactions, neutron fields usually also consist of secondary particles such as photons and protons of diverse energies. Various experiments have been carried out in three different...
journal_title:Medical physics
pub_type: 杂志文章,多中心研究
doi:10.1118/1.4901299
更新日期:2015-01-01 00:00:00
abstract:PURPOSE:In this study, the authors validated a novel respiratory tracking device, the multidimensional respiratory tracking (MDRT) system, that was designed to assist in correcting for respiratory motion in PET/CT images. The authors also investigated a novel PET acquisition technique, smart gating (SG), that enables t...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3523100
更新日期:2011-01-01 00:00:00
abstract::The method of images is employed to insert the effects of the presence of a single lateral boundary on contrast functions previously derived for an infinite slab using a random walk model of photon transport. The predictions of the model for zero and extrapolated boundary conditions are compared with Monte Carlo (MC) ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598687
更新日期:1999-09-01 00:00:00