Sci-Sat AM(1): Imaging-01: Tumour and normal tissue T2 and ADC distributions for a mouse model at 9.4T.

Abstract:

:Magnetic resonance (MR) measurements of relaxation times and diffusion coefficient in tissue have been demonstrated to be sensitive to biological changes induced by radiation therapy. We are currently using mouse models of human glioblastoma multiforme (GBM) to study tumour response to ionizing radiation by MRI at 9.4T. Utilizing conventional imaging techniques coupled with quantitative measurements of transverse relaxation time (T2) and apparent diffusion coefficient (ADC), we monitor changes during tumour growth and subsequent changes after single-fraction radiotherapy. In addition to tumour parameters, we have measured T2 and ADC in other structures that appear in the same transverse slices as tumour tissue. Here we report the measured distributions of T2 and ADC in tumour and in normal tissues that are likely to be encountered during MR imaging of tumour xenografts in mice, including liver, kidney, fat, skeletal muscle, spinal cord, and brain. Quantitative knowledge of these distributions in normal tissue is important in optimizing the sequences used for imaging of these tissues, and in optimizing continued measurements of T2 and ADC changes. Knowledge of parameter distributions in tumour is important because recent studies have suggested that the T2 and ADC responses after therapy may be the result of large shifts in smaller isolated pockets of tumour, rather than more moderate shifts in T2 and ADC over the whole tumour volume. These distributions provide a baseline measurement of typical distributions in advance of radiation therapy.

journal_name

Med Phys

journal_title

Medical physics

authors

Larocque M,Syme A,Fallone BG

doi

10.1118/1.2965985

subject

Has Abstract

pub_date

2008-07-01 00:00:00

pages

3414

issue

7Part3

eissn

0094-2405

issn

2473-4209

journal_volume

35

pub_type

杂志文章
  • Impact of transverse magnetic fields on dose response of a radiophotoluminescent glass dosimeter in megavoltage photon beams.

    abstract:PURPOSE:The purpose of this study was to investigate the impact of transverse magnetic fields on the dose response of a radiophotoluminescent glass dosimeter (RGD) in megavoltage photon beams. METHODS:The RGD relative response (i.e., RGD dose per absorbed dose to water at the midpoint of the detector in the absence of...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14054

    authors: Ito S,Araki F,Ohno T

    更新日期:2020-04-01 00:00:00

  • A fast 4D IMRT/VMAT planning method based on segment aperture morphing.

    abstract:PURPOSE:Four-dimensional volumetric modulated arc therapy (4D VMAT) and four-dimensional intensity-modulated radiotherapy (4D IMRT) are developing radiation therapy treatment strategies designed to maximize dose conformality, minimize normal tissue dose, and deliver the treatment as efficiently as possible. The patient...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12778

    authors: Klawikowski S,Tai A,Ates O,Ahunbay E,Li XA

    更新日期:2018-04-01 00:00:00

  • Dose planning with comparison to in vivo dosimetry for epithermal neutron irradiation of the dog brain.

    abstract::Boron neutron capture therapy (BNCT) is an experimental type of radiotherapy, presently being used to treat glioblastoma and melanoma. To improve patient safety and to determine the radiobiological characteristics of the epithermal neutron beam of Finnish BNCT facility (FiR 1) dose-response studies were carried on the...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1517048

    authors: Seppälä T,Auterinen I,Aschan C,Serén T,Benczik J,Snellman M,Huiskamp R,Ramadan UA,Kankaanranta L,Joensuu H,Savolainen S

    更新日期:2002-11-01 00:00:00

  • Broad line quantitative chemical shift spectroscopy.

    abstract::Proton NMR spectroscopy was applied to quantitate the measurement of total body water/fat distributions in vivo. A special MR protocol was developed to excite a thick slab of tissue and display the magnitude NMR spectrum of the collected response signal. Very short echo time TE (8 ms) and long repetition time TR (4000...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596935

    authors: Sobol WT,Elster AD,Hinson WH,Chwals WJ

    更新日期:1992-01-01 00:00:00

  • Photoelectric-enhanced radiation therapy with quasi-monochromatic computed tomography.

    abstract::Photoelectric-enhanced radiation therapy is a bimodal therapy, consisting of the administration of highly radiation-absorbing substances into the tumor area and localized regional irradiation with orthovoltage x-rays. Irradiation can be performed by a modified computed tomography (CT) unit equipped with an additional ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3125137

    authors: Jost G,Mensing T,Golfier S,Lawaczeck R,Pietsch H,Hütter J,Cibik L,Gerlach M,Krumrey M,Fratzscher D,Arkadiev V,Wedell R,Haschke M,Langhoff N,Wust P,Lüdemann L

    更新日期:2009-06-01 00:00:00

  • Fully automated segmentation of oncological PET volumes using a combined multiscale and statistical model.

    abstract::The widespread application of positron emission tomography (PET) in clinical oncology has driven this imaging technology into a number of new research and clinical arenas. Increasing numbers of patient scans have led to an urgent need for efficient data handling and the development of new image analysis techniques to ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2432404

    authors: Montgomery DW,Amira A,Zaidi H

    更新日期:2007-02-01 00:00:00

  • Skeletal dosimetry for external exposures to photons based on microCT images of spongiosa: consideration of voxel resolution, cluster size, and medullary bone surfaces.

    abstract::Skeletal dosimetry based on microCT images of trabecular bone has recently been introduced to calculate the red bone marrow (RBM) and the bone surface cell (BSC) equivalent doses in human phantoms for external exposure to photons. In order to use the microCT images for skeletal dosimetry, spongiosa voxels in the skele...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3242266

    authors: Kramer R,Khoury HJ,Vieira JW,Robson Brown KA

    更新日期:2009-11-01 00:00:00

  • Material elemental decomposition in dual and multi-energy CT via a sparsity-dictionary approach for proton stopping power ratio calculation.

    abstract:PURPOSE:Accurate calculation of proton stopping power ratio (SPR) relative to water is crucial to proton therapy treatment planning, since SPR affects prediction of beam range. Current standard practice derives SPR using a single CT scan. Recent studies showed that dual-energy CT (DECT) offers advantages to accurately ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12796

    authors: Shen C,Li B,Chen L,Yang M,Lou Y,Jia X

    更新日期:2018-04-01 00:00:00

  • Beam shaper with optimized dose utility for helical cone-beam CT.

    abstract:PURPOSE:To develop a new design of an x-ray beam shaper for helical computed tomography (CT) that increases the dose utilization. METHODS:For typical reconstruction algorithms in helical CT, different data are utilized with different weights during back-projection. In particular, data of the outer detector rows, i.e.,...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3577766

    authors: Köhler T,Brendel B,Proksa R

    更新日期:2011-07-01 00:00:00

  • Predicting the noise in hybrid (phase and attenuation) x-ray images acquired with the edge illumination technique.

    abstract:PURPOSE:To analyze the noise performance of the edge illumination phase-based x-ray imaging technique when applying "single-shot" phase retrieval. The latter consists in applying a sample-specific low-pass filter to the raw data, leading to "hybrid" images in which phase and attenuation contrast are merged with each ot...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14366

    authors: Hagen CK,Roche I Morgó O,Olivo A

    更新日期:2020-09-01 00:00:00

  • Evaluation of dual energy quantitative CT for determining the spatial distributions of red marrow and bone for dosimetry in internal emitter radiation therapy.

    abstract:PURPOSE:To evaluate a three-equation three-unknown dual-energy quantitative CT (DEQCT) technique for determining region specific variations in bone spongiosa composition for improved red marrow dose estimation in radionuclide therapy. METHODS:The DEQCT method was applied to 80/140 kVp images of patient-simulating lumb...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4870378

    authors: Goodsitt MM,Shenoy A,Shen J,Howard D,Schipper MJ,Wilderman S,Christodoulou E,Chun SY,Dewaraja YK

    更新日期:2014-05-01 00:00:00

  • Performance of a 41 x 41 cm2 amorphous silicon flat panel x-ray detector designed for angiographic and R&F imaging applications.

    abstract::We measured the physical imaging performance of a 41 x 41 cm2 amorphous silicon flat panel detector designed for angiographic and R&F imaging applications using methods from the emerging IEC standard for the measurement of detective quantum efficiency (DQE) in digital radiographic detectors. Measurements on 12 product...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1609151

    authors: Granfors PR,Aufrichtig R,Possin GE,Giambattista BW,Huang ZS,Liu J,Ma B

    更新日期:2003-10-01 00:00:00

  • Predicting target vessel location on robot-assisted coronary artery bypass graft using CT to ultrasound registration.

    abstract:PURPOSE:Although robot-assisted coronary artery bypass grafting (RA-CABG) has gained more acceptance worldwide, its success still depends on the surgeon's experience and expertise, and the conversion rate to full sternotomy is in the order of 15%-25%. One of the reasons for conversion is poor pre-operative planning, wh...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3684958

    authors: Cho DS,Linte C,Chen EC,Bainbridge D,Wedlake C,Moore J,Barron J,Patel R,Peters T

    更新日期:2012-03-01 00:00:00

  • Towards Data-Efficient Learning: A Benchmark for COVID-19 CT Lung and Infection Segmentation.

    abstract:PURPOSE:Accurate segmentation of lung and infection in COVID-19 computed tomography (CT) scans plays an important role in the quantitative management of patients. Most of the existing studies are based on large and private annotated datasets that are impractical to obtain from a single institution, especially when radi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14676

    authors: Ma J,Wang Y,An X,Ge C,Yu Z,Chen J,Zhu Q,Dong G,He J,He Z,Cao T,Zhu Y,Nie Z,Yang X

    更新日期:2020-12-23 00:00:00

  • 4D rotational x-ray imaging of wrist joint dynamic motion.

    abstract::Current methods for imaging joint motion are limited to either two-dimensional (2D) video fluoroscopy, or to animated motions from a series of static three-dimensional (3D) images. 3D movement patterns can be detected from biplane fluoroscopy images matched with computed tomography images. This involves several x-ray ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2000647

    authors: Carelsen B,Bakker NH,Strackee SD,Boon SN,Maas M,Sabczynski J,Grimbergen CA,Streekstra GJ

    更新日期:2005-09-01 00:00:00

  • Rare-earth scatter fractions in chest radiography.

    abstract::A beam stop technique was used to measure the densitometric scatter fractions under three regions of a humanoid chest phantom utilizing LaOBr and Gd2O2S screens. For these receptors, the scatter fractions under the lung and retrocardiac areas were 13%-36% lower than published values for CaWO4. In the mediastinal area,...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597041

    authors: Petrone TJ,Steidley KD

    更新日期:1993-03-01 00:00:00

  • 2-Step IMAT and 2-Step IMRT: a geometrical approach.

    abstract::The purpose of this paper is to develop a method that reduces the number of segments for intensity modulated arc therapy (IMAT) and intensity modulated radiotherapy (IMRT) for concave target volumes (TV). The aim was to utilize no more than two intensity levels per organ at risk (OAR) and to derive both optimal segmen...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1861161

    authors: Bratengeier K

    更新日期:2005-03-01 00:00:00

  • Three-dimensional ultrasound system for guided breast brachytherapy.

    abstract::Breast-conserving surgery combined with subsequent radiation therapy is a standard procedure in breast cancer treatment. The disadvantage of whole-breast beam irradiation is that it requires 20-25 treatment days, which is inconvenient for patients with limited mobility or who reside far from the treatment center. Howe...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3243865

    authors: De Jean P,Beaulieu L,Fenster A

    更新日期:2009-11-01 00:00:00

  • Dental enamel as an in vivo radiation dosimeter.

    abstract::The determination of the radiation exposure history of the population has become increasingly important in the study of the effects of low-level radiation. The present work was started to try to obtain an in vivo dosimeter that could give an indication of radiation exposure. Dental enamel is the only living tissue whi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595768

    authors: Pass B,Aldrich JE

    更新日期:1985-05-01 00:00:00

  • Effect of finite sample size on feature selection and classification: a simulation study.

    abstract:PURPOSE:The small number of samples available for training and testing is often the limiting factor in finding the most effective features and designing an optimal computer-aided diagnosis (CAD) system. Training on a limited set of samples introduces bias and variance in the performance of a CAD system relative to that...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3284974

    authors: Way TW,Sahiner B,Hadjiiski LM,Chan HP

    更新日期:2010-02-01 00:00:00

  • Comparison of exposure standards in the mammography x-ray region.

    abstract::Direct comparisons of the National Institute of Standards and Technology's (NIST) Ritz 20 kV to 100 kV standard free-air ionization chamber and a portable variable-length free-air ionization chamber designed by the University of Wisconsin-Madison Accredited Dosimetry Calibration Laboratory (UW-ADCL) were made on NISTs...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598148

    authors: Coletti JG,Pearson DW,DeWerd LA,O'Brien CM,Lamperti PJ

    更新日期:1997-08-01 00:00:00

  • Recognition of healthy and cancerous breast cells: Sensing the differences by dielectric spectroscopy.

    abstract:PURPOSE:The response of human cells to applied electrical signals depends on the cellular health status, because it is influenced by the composition and structure of the main cellular components. Therefore, electrical impedance-based techniques can be considered as sensitive tools to investigate healthy or disease stat...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14425

    authors: Ambrico M,Lasalvia M,Ligonzo T,Ambrico PF,Perna G,Capozzi V

    更新日期:2020-10-01 00:00:00

  • A dosimetric comparison of 169Yb and 192Ir for HDR brachytherapy of the breast, accounting for the effect of finite patient dimensions and tissue inhomogeneities.

    abstract::Monte Carlo simulation dosimetry is used to compare 169Yb to 192Ir for breast high dose rate (HDR) brachytherapy applications using multiple catheter implants. Results for bare point sources show that while 169Yb delivers a greater dose rate per unit air kerma strength at the radial distance range of interest to brach...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2392408

    authors: Lymperopoulou G,Papagiannis P,Angelopoulos A,Karaiskos P,Georgiou E,Baltas D

    更新日期:2006-12-01 00:00:00

  • In vivo surface dosimetry with a scintillating fiber dosimeter in preclinical image-guided radiotherapy.

    abstract:PURPOSE:New preclinical image-guided irradiators and treatment planning systems represent a huge progress in radiobiology. Nevertheless, quality control of preclinical treatments is not as advanced as in clinical radiotherapy and in vivo dosimetry is less developed. In this study, we evaluate the use of a scintillating...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13903

    authors: Le Deroff C,Pérès EA,Ledoux X,Toutain J,Frelin-Labalme AM

    更新日期:2020-01-01 00:00:00

  • Approximate 3D iterative reconstruction for SPECT.

    abstract::Compared with slice-by-slice approaches for SPECT reconstruction, three-dimensional iterative methods provide a more accurate physical model and an improved SPECT image. Clinical application of these methods, however, is limited primarily to their computational demands. This paper investigates the methods for approxim...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598030

    authors: Gilland DR,Jaszczak RJ,Riauka TA,Coleman RE

    更新日期:1997-09-01 00:00:00

  • 3D modeling of effects of increased oxygenation and activity concentration in tumors treated with radionuclides and antiangiogenic drugs.

    abstract:PURPOSE:Formation of new blood vessels (angiogenesis) in response to hypoxia is a fundamental event in the process of tumor growth and metastatic dissemination. However, abnormalities in tumor neovasculature often induce increased interstitial pressure (IP) and further reduce oxygenation (pO2) of tumor cells. In radiot...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3615164

    authors: Lagerlöf JH,Kindblom J,Bernhardt P

    更新日期:2011-08-01 00:00:00

  • Development and clinical implementation of semi-automated treatment planning including 3D printable applicator holders in complex skin brachytherapy.

    abstract:PURPOSE:High-dose-rate brachytherapy (HDR-BT) is a treatment option for malignant skin diseases compared to external beam radiation therapy, HDR-BT provides improved target coverage, better organ sparing, and has comparable treatment times. This is especially true for large clinical targets with complex topologies. To ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13975

    authors: Guthier CV,Devlin PM,Harris TC,O'Farrell DA,Cormack RA,Buzurovic I

    更新日期:2020-03-01 00:00:00

  • The alanine detector in BNCT dosimetry: dose response in thermal and epithermal neutron fields.

    abstract:PURPOSE:The response of alanine solid state dosimeters to ionizing radiation strongly depends on particle type and energy. Due to nuclear interactions, neutron fields usually also consist of secondary particles such as photons and protons of diverse energies. Various experiments have been carried out in three different...

    journal_title:Medical physics

    pub_type: 杂志文章,多中心研究

    doi:10.1118/1.4901299

    authors: Schmitz T,Bassler N,Blaickner M,Ziegner M,Hsiao MC,Liu YH,Koivunoro H,Auterinen I,Serén T,Kotiluoto P,Palmans H,Sharpe P,Langguth P,Hampel G

    更新日期:2015-01-01 00:00:00

  • A novel respiratory tracking system for smart-gated PET acquisition.

    abstract:PURPOSE:In this study, the authors validated a novel respiratory tracking device, the multidimensional respiratory tracking (MDRT) system, that was designed to assist in correcting for respiratory motion in PET/CT images. The authors also investigated a novel PET acquisition technique, smart gating (SG), that enables t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3523100

    authors: Nehmeh SA,Haj-Ali AA,Qing C,Stearns C,Kalaigian H,Kohlmyer S,Schoder H,Ho AY,Larson SM,Humm JL

    更新日期:2011-01-01 00:00:00

  • Effect of lateral boundaries on contrast functions in time-resolved transillumination measurements.

    abstract::The method of images is employed to insert the effects of the presence of a single lateral boundary on contrast functions previously derived for an infinite slab using a random walk model of photon transport. The predictions of the model for zero and extrapolated boundary conditions are compared with Monte Carlo (MC) ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598687

    authors: Chernomordik V,Gandjbakhche AH,Hebden JC,Zaccanti G

    更新日期:1999-09-01 00:00:00