Abstract:
PURPOSE:In this study, the authors validated a novel respiratory tracking device, the multidimensional respiratory tracking (MDRT) system, that was designed to assist in correcting for respiratory motion in PET/CT images. The authors also investigated a novel PET acquisition technique, smart gating (SG), that enables to acquire motion-free PET data prospectively, with minimum user interference and with no additional postprocessing of the PET data. METHODS:MDRT uses visual tracking techniques to track simultaneously the two-dimensional (in the vertical plane) motion of multiple fiducial markers using a standard video camera. A threshold window is set at the breathing amplitude of interest using the MDRT GUI. A trigger is generated at a rate of 250 Hz as long as the breathing signal is within the threshold window. The triggers are fed into the PET scanner to initialize one single bin of a gated acquisition every 4 ms. No triggers are delivered as the breathing signal drifts outside the threshold window. Consequently, PET data are acquired only whenever the breathing signal is confined within the amplitude threshold window, thus resulting into a motion-free image set. The accuracy of MDRT in tracking the breathing signal was assessed (1) by comparing the period of an oscillating phantom, as measured by MDRT, to that measured with a photogate timer and (2) by comparing the MDRT output to that of the real-time position management (RPM) in ten patients. The SG PET/CT acquisition was validated in phantoms and in two stereotactic body radiosurgery (SBRS) lung DIBH-PET/CT patients. RESULTS:MDRT was in agreement with the photogate timer in determining the period of motion to less than 2%. The percent errors between MDRT and RPM in the positions of the peaks and troughs of the ten patients' breathing signals were within 10%. In phantoms, SG technique enables to correct for motion-induced artifacts in the PET images and improve the accuracy of PET quantitation. For the SBRS application, in one patient, the patient's CT lesion was not detected in the corresponding clinical PET images, while it exhibited an SUV of 1.8 in the DIBH image set. In the second patient, DIBH-PET images showed an improved PET-to-CT spatial matching and a 52% increase in the lesion SUV. CONCLUSIONS:MDRT has been shown to be accurate in tracking breathing motion and assisted in implementing a smart-gating PET acquisition technique that allowed to acquire prospectively motion-free PET images.
journal_name
Med Physjournal_title
Medical physicsauthors
Nehmeh SA,Haj-Ali AA,Qing C,Stearns C,Kalaigian H,Kohlmyer S,Schoder H,Ho AY,Larson SM,Humm JLdoi
10.1118/1.3523100subject
Has Abstractpub_date
2011-01-01 00:00:00pages
531-8issue
1eissn
0094-2405issn
2473-4209journal_volume
38pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract:PURPOSE:Sterile radiation reduction gloves have been widely used in the past decade to provide modest decreases in operator hand dose when the hands are placed in the field of view (FOV). While multiple publications have quantified the potential dose reduction from the use of such gloves, possible effects on the patien...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4734747
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:The purpose of this study was to describe and evaluate methods for calculating a megavoltage computed tomography (MVCT)-derived MR hardware attenuation map (μ-map) and dual-energy CT (DECT) for 511 keV photons. METHODS:Phantom measurements were acquired on a whole-body hybrid PET/MRI system, using a four-chann...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12407
更新日期:2017-09-01 00:00:00
abstract::A study of the objective imaging characteristics of a new asymmetric screen-film system is presented herein. The system is characterized by high x-ray absorption asymmetric screens, and a low-noise, high-contrast asymmetric film having near-zero crossover. Comparisons are made with the imaging characteristics of two w...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597407
更新日期:1994-09-01 00:00:00
abstract:PURPOSE:Recently, brain tumor segmentation has made important progress. However, the quality of manual labels plays an important role in the performance, while in practice, it could vary greatly and in turn could substantially mislead the learning process and decrease the accuracy. We need to design a mechanism to comb...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14480
更新日期:2020-09-24 00:00:00
abstract::Proton beams offer several advantages over conventional radiation techniques for treating cancer and other diseases. These advantages might be negated if the leakage and scatter radiation from the beamline and patient are too large. Although the leakage and scatter radiation for the double scattering proton beamlines ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2805086
更新日期:2008-01-01 00:00:00
abstract::Numerical reconstruction of x-ray spectra from narrow-beam transmission data was tested with published spectra in the range from 45 to 100 kVp. Transmission curves were calculated from the spectra to simulate measured data. Spectra were reconstructed from these transmission curves with use of an iterative numerical an...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595834
更新日期:1986-09-01 00:00:00
abstract:PURPOSE:In Stereotactic body radiation therapy (SBRT) higher dose per fraction is delivered to patients and thus the need for an accurate dose computation is further elevated. However under such conditions of small field geometries, the electronic equilibrium can be lost, making it challenging for the dose-calculation ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735539
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:The purpose of this study was to develop a dual-modality positron emission tomography (PET)/magnetic resonance imaging (MRI) with insertable PET for simultaneous PET and MR imaging of the human brain. METHODS:The PET detector block was composed of a 4 × 4 matrix of detector modules, each consisting of a 4 × 4 ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4918321
更新日期:2015-05-01 00:00:00
abstract:PURPOSE:X-ray phase-contrast tomography (PCT) is a rapidly emerging imaging modality for reconstructing estimates of an object's three-dimensional x-ray refractive index distribution. Unlike conventional x-ray computed tomography methods, the statistical properties of the reconstructed images in PCT remain unexplored. ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3267548
更新日期:2010-01-01 00:00:00
abstract::In this paper a novel technique is proposed and validated for radiosurgery treatment planning of arteriovenous malformations (AVMs). The technique was developed for frameless radiosurgery by means of the CyberKnife, a nonisocentric, linac-based system which allows highly conformed isodose surfaces to be obtained, whil...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1751252
更新日期:2004-06-01 00:00:00
abstract::A computed tomography (CT) based system that compensates for patient surface contour and internal tissue inhomogeneity was implemented in our clinic. The compensators are fabricated with a mixture of tin granules and bee's wax. The tin/wax mixture was optimized for tin granule size and tin granule to wax ratio. The na...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597303
更新日期:1994-03-01 00:00:00
abstract:PURPOSE:Modern clinical accelerators are capable of producing ion beams from protons up to neon. This work compares the depth dose distribution and corresponding dose averaged linear energy transfer (LET) distribution, which is related to the biological effectiveness, for different ion beams (¹H, ⁴He, ⁶Li, ⁸Be, ¹⁰B, ¹²...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3662911
更新日期:2011-12-01 00:00:00
abstract:PURPOSE:To determine the diagnostic efficacy of optical coherence tomography (OCT) to identify cervical intraepithelial neoplasia (CIN) grade 2 or higher by computer-aided diagnosis (CADx). METHODS:OCT has been investigated as a screening/diagnostic tool in the management of preinvasive and early invasive cancers of t...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3523098
更新日期:2011-01-01 00:00:00
abstract:PURPOSE:Modulated electron radiation therapy (MERT) represents an active area of interest that offers the potential to improve healthy tissue sparing in treatment of certain cancer cases. Challenges remain however in accurate beamlet dose calculation, plan optimization, collimation method, and delivery accuracy. In thi...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4876297
更新日期:2014-06-01 00:00:00
abstract:PURPOSE:Distortions in magnetic resonance imaging (MRI) compromise spatial fidelity, potentially impacting delineation and dose calculation. We characterized 2D and 3D large field of view (FOV), sequence-independent distortion at various positions in a 1.0 T high-field open MR simulator (MR-SIM) to implement correction...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4930245
更新日期:2015-10-01 00:00:00
abstract::An algorithm, which combines the scanning beam with dynamic collimation to generate any arbitrary intensity profile, is presented. The desired intensity profile is assumed to be piecewise linear. The dynamic collimation method used is the "sliding window." The algorithm can be used either for a given scanning beam pro...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597672
更新日期:1996-01-01 00:00:00
abstract::A restricted angular scattering model for electron penetration in dense media is presented. In the model, the Fermi-Eyges transport equation is modified through the addition of an extra term which may be interpreted as representing an apparent force opposing the scattering of electrons into wider angles. The introduct...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596747
更新日期:1991-01-01 00:00:00
abstract:PURPOSE:To investigate how using different sets of decision criteria impacts the quality of intensity modulated radiation therapy (IMRT) plans obtained by multiobjective optimization. METHODS:A multiobjective optimization evolutionary algorithm (MOEA) was used to produce sets of IMRT plans. The MOEA consisted of two i...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3589128
更新日期:2011-06-01 00:00:00
abstract::Patient-specific intensity-modulated radiotherapy (IMRT) verifications require an accurate two-dimensional dosimeter that is not labor-intensive. We assessed the precision and reproducibility of film calibrations over time, measured the elemental composition of the film, measured the intermittency effect, and measured...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1852791
更新日期:2005-02-01 00:00:00
abstract:PURPOSE:The aim of the study was to evaluate the impact of multileaf collimator (MLC) leaf width on treatment adaptation and delivery accuracy for concurrent treatment of the prostate and pelvic lymph nodes with intensity modulated radiation therapy (IMRT). METHODS:Seventy-five kilovoltage cone beam CTs (KV-CBCT) from...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4803499
更新日期:2013-06-01 00:00:00
abstract::90Y-labeled SIR-Spheres are currently used to treat patients with hepatic metastases secondary to colorectal adenocarcinoma. In general, the prescribed activity is based on empirical data collected during clinical trials. The activity of the source vial is labeled by the manufacturer as 3.0 GBq +/- 10% and is not inde...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2889621
更新日期:2008-04-01 00:00:00
abstract:PURPOSE:To show that Cherenkov emission is generated by external radiotherapy beam in tissue, and could serve as optical source to excite an oxygen sensitive phosphor, Oxyphor G4, within tissue. The intensity and lifetime of the phosphorescence was measured with a time-gated system and reveals the oxygenation levels in...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4734811
更新日期:2012-06-01 00:00:00
abstract::The output factor for a therapy photon beam is defined as the dose per monitor unit relative to the dose per monitor unit in a reference field. Convolution models for photon dose calculations yield the dose in units normalized to the incident energy fluence with phantom scatter intrinsically modeled. Output factors ca...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596859
更新日期:1992-03-01 00:00:00
abstract:PURPOSE:The authors' objective was to compare internal dose estimates obtained using the Organ Level Dose Assessment with Exponential Modeling (OLINDA/EXM) software, the voxel S value technique, and Monte Carlo simulation. Monte Carlo dose estimates were used as the reference standard to assess the impact of patient-sp...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4892606
更新日期:2014-09-01 00:00:00
abstract:PURPOSE:The absolute dose rate of the Imaging and Medical Beamline (IMBL) on the Australian Synchrotron was measured with a graphite calorimeter. The calorimetry results were compared to measurements from the existing free-air chamber, to provide a robust determination of the absolute dose in the synchrotron beam and p...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4870387
更新日期:2014-05-01 00:00:00
abstract:PURPOSE:Small animal immobilization devices facilitate positioning of animals for reproducible imaging and accurate focal radiation therapy. In this study, the authors demonstrate the use of three-dimensional (3D) printing technology to fabricate a custom-designed mouse head restraint. The authors evaluate the accuracy...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4933200
更新日期:2015-11-01 00:00:00
abstract::In this study, we present an algorithm for three-dimensional (3-D) dose reconstruction using portal images obtained with an electronic portal imaging device (EPID). For this purpose an algorithm for 2-D dose reconstruction, which was previously developed in our institution, was adapted. The external contour of the pat...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1589496
更新日期:2003-09-01 00:00:00
abstract::Treatment planning for brachytherapy requires the acquisition of geometrical information of the implant applicator and the patient anatomy. This is typically done using a simulator or a computed tomography scanner. In this study, we present a different method by which orthogonal images from a C-arm fluoroscopic machin...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1598851
更新日期:2003-09-01 00:00:00
abstract:PURPOSE:The authors investigate the extent to which Response Evaluation Criteria in Solid Tumors (RECIST) can predict tumor volumes in ideal geometric settings and using clinical data. METHODS:The authors consider a hierarchy of models including uniaxial ellipsoids, general ellipsoids, and composites of ellipsoids, us...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3577602
更新日期:2011-05-01 00:00:00
abstract::Accurate and reliable thermometry is essential in the development of microwave-induced hyperthermal cancer therapy. While temperature measurements in strong electromagnetic fields usually require special sensors, this does not hold true for interstitial radiator/sensor systems. Miniature thermistors (with metallic lea...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595261
更新日期:1983-05-01 00:00:00