Abstract:
:In this paper a novel technique is proposed and validated for radiosurgery treatment planning of arteriovenous malformations (AVMs). The technique was developed for frameless radiosurgery by means of the CyberKnife, a nonisocentric, linac-based system which allows highly conformed isodose surfaces to be obtained, while also being valid for other treatment strategies. The technique is based on registration between computed tomography (CT) and three-dimensional rotational angiography (3DRA). Tests were initially performed on the effectiveness of the correction method for distortion offered by the angiographic system. These results determined the registration technique that was ultimately chosen. For CT-3DRA registration, a twelve-parameter affine transformation was selected, based on a mutual information maximization algorithm. The robustness of the algorithm was tested by attempting to register data sets increasingly distant from each other, both in translation and rotation. Registration accuracy was estimated by means of the "full circle consistency test." A registration quality index (expressed in millimeters) based on these results was also defined. A hybrid subtraction between CT and 3DRA is proposed in order to improve 3D reconstruction. Preprocessing improved the ability of the algorithm to find an acceptable solution to the registration process. The robustness tests showed that data sets must be manually prealigned within approximately 15 mm and 20 degrees with respect to all three directions simultaneously. Results of the consistency test showed agreement between the quality index and registration accuracy stated by visual inspection in 20 good and 10 artificially worsened registration processes. The quality index showed values smaller than the maximum voxel size (mean 0.8 mm compared to 2 mm) for all successful registrations, while it resulted in much greater values (mean 20 mm) for unsuccessful registrations. Once registered, the two data sets can be used for CyberKnife treatment planning. Target delineation is performed on 3DRA while dose calculation and DRR generation are performed on CT. In conclusion, a method was developed for using 3DRA images for AVM frameless radiosurgery treatment planning. The method proved to be feasible, robust, and accurate for clinical use. 3DRA can be performed at different times or locations compared to standard, frame based stereotactic angiography. Unlike two-dimensional angiography, 3DRA allows examination of the shape of the AVM and of the surrounding target from any arbitrary point of view during treatment planning. The method can be applied to any case of intermodality registration, is operator-independent, and allows estimation of registration quality. Further research is desirable to improve time resolution in order to distinguish between feeding and draining vessels.
journal_name
Med Physjournal_title
Medical physicsauthors
Stancanello J,Cavedon C,Francescon P,Cerveri P,Ferrigno G,Colombo F,Perini Sdoi
10.1118/1.1751252subject
Has Abstractpub_date
2004-06-01 00:00:00pages
1363-71issue
6eissn
0094-2405issn
2473-4209journal_volume
31pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract:PURPOSE:Robust registration of prone and supine colonie surfaces acquired during CT colonography may lead to faster and more accurate detection of colorectal cancer and polyps. Any directional bias when registering one surface to the other could precipitate incorrect anatomical correspondence and engender reader error....
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4736159
更新日期:2012-06-01 00:00:00
abstract::We have studied the effect of real-time optical image processing (OIP) in an image intensifier/television (II-TV) radiographic imaging system by using a liquid-crystal display (LCD) placed between the II and the TV camera. The LCD compresses the dynamic range of the transmitted image by modulating the spatial distribu...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596199
更新日期:1988-11-01 00:00:00
abstract::Seeds containing radioactive Ytterbium-169 (169Yb) have recently been manufactured for possible application to brachytherapy. Ytterbium-169 emits photons with an average energy of 93 keV (excluding energies less than 10 keV), and decays with a half-life of 32 days. Analytic and Monte Carlo computations have been used ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596813
更新日期:1992-05-01 00:00:00
abstract:PURPOSE:In this study, we evaluated the degree of consistency between size metrics obtained from PEM and MRI to determine the intrinsic effectiveness of a multimodality approach using these two systems for breast imaging. METHODS:Under an IRB-approved protocol, 42 cases were considered (16 patients with 28 lesions), e...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735979
更新日期:2012-06-01 00:00:00
abstract::The effectiveness of film-screen mammography is limited by tradeoffs between latitude and contrast, film granularity, and the need to increase dose when antiscatter methods are used. We are currently developing a scanned-projection digital mammography (SPDM) system to overcome these limitations. The system consists of...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596147
更新日期:1987-09-01 00:00:00
abstract::The BrachySeed model LS-1 is one of the latest in a series of new brachytherapy 125I seeds that have recently become available commercially for interstitial implants. The dosimetric properties of the seed were investigated analytically, experimentally, and by Monte Carlo simulation. Following the AAPM Task Group 43 fo...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1445411
更新日期:2002-02-01 00:00:00
abstract::Projected light fields are used on treatment simulators and teletherapy treatment units to delineate the size and position of the radiation beam. Any discrepancy between these fields will lead to a systematic field placement error, with possibly serious implications with regard to the accuracy of the delivered dose di...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597867
更新日期:1996-07-01 00:00:00
abstract:PURPOSE:The aim of this research was to explore x-ray beam parameters with intent to optimize pediatric x-ray settings in the cardiac catheterization laboratory. This study examined the effects of peak x-ray tube voltage (kVp) and of copper (Cu) x-ray beam filtration independently on the image quality to dose balance f...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3488911
更新日期:2010-10-01 00:00:00
abstract::Segmentation of the lungs within magnetic resonance (MR) scans is a necessary step in the computer-based analysis of thoracic MR images. This process is often confounded by image acquisition artifacts and disease-induced morphological deformation. We have developed an automated method for lung segmentation that is ins...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2214165
更新日期:2006-09-01 00:00:00
abstract:PURPOSE:To evaluate if the recently described problems with the calibration of jaws at Varian linear accelerators can be detected with the DAVID system. METHODS:Recently Varian Clinac field size issues resulted in a widespread medical device correction notice, stating that incorrect jaw positioning due to excessive co...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4736189
更新日期:2012-06-01 00:00:00
abstract::For the case of eye tumor therapy with protons, improvements are introduced compared to the standard dose calculation which implies straight-line optics and the constant-density assumption for the eye and its surrounding. The progress consists of (i) taking account of the lateral scattering of the protons in tissue by...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2168067
更新日期:2006-03-01 00:00:00
abstract:PURPOSE:Monitoring of physiological parameters is a major concern in Intensive Care Units (ICU) given their role in the assessment of vital organ function. Within this context, one issue is the lack of efficient noncontact techniques for respiratory monitoring. In this paper, we present a novel noncontact solution for ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14557
更新日期:2020-10-28 00:00:00
abstract::Nowadays, digital subtraction angiography systems must be able to sustain real-time acquisition (30 frames per second) of 512 x 512 x 8 bit images and store several sequences of such images on low cost and general-purpose mass memories. Concretely, that means a 7.8 Mbytes per second rate and about 780 Mbytes disk spac...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596309
更新日期:1989-11-01 00:00:00
abstract::An optimization analysis of digital fluoroscopy has been carried out using (signal/noise)2/dose as a figure of merit. Three signal detection tasks have been considered: (i) small iodine-containing blood vessels; (ii) regions of fat; and (iii) microcalcifications. The effects of x-ray beam filtration and kilovoltage on...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595130
更新日期:1982-09-01 00:00:00
abstract:PURPOSE:To compare reconstructed volumes calculated via planimetry and frustum algorithms in the context of stepped transrectal ultrasound (US) imaging, and to estimate the reconstruction error for prostate volumes. METHODS:Prostate contours for 40 permanent implant patients were delineated on magnetic resonance (MR) ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4789920
更新日期:2013-03-01 00:00:00
abstract::A 4-W, laser-based system for the positional readout of thermoluminescent (TL) plates was utilized to obtain dose profiles for a 60Co radiotherapy beam. Experimentally obtained glow curves for LiF resulting from the rapid heating rates characteristic of laser heating agreed well with results predicted using a first-or...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596580
更新日期:1990-05-01 00:00:00
abstract::Separation of water from fat tissues in magnetic resonance imaging is important for many applications because signals from fat tissues often interfere with diagnoses that are usually based on water signal characteristics. Water and fat can be separated with images acquired at different echo time shifts. The three-poin...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2952644
更新日期:2008-08-01 00:00:00
abstract:PURPOSE:Melanoma is the most lethal of the three primary skin cancers, including also basal cell carcinoma (BCC) and squamous cell carcinoma (SCC), which are less lethal. The accepted diagnosis process involves manually observing a suspicious lesion through a Dermascope (i.e., a magnifying glass), followed by a biopsy....
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14471
更新日期:2020-11-01 00:00:00
abstract::In order to determine accurately the relative x-ray intensities transmitted through the different steps of an aluminum stepwedge and incident on an image intensifier (II)-TV digital system, we used a 100-mm camera which was attached to the II output. The characteristic curves of an II-TV digital system, which relate t...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595819
更新日期:1986-11-01 00:00:00
abstract:PURPOSE:In this study, a dedicated device for ion chamber measurements of absorbed dose-to-water for a Nucletron microSelectron-v2 HDR (192)Ir brachytherapy source is presented. The device uses two ionization chambers in a so-called sandwich assembly. Using this setup and by taking the average reading of the two chambe...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4816673
更新日期:2013-09-01 00:00:00
abstract:PURPOSE:We studied the sensitivity of a novel transmission fiber scintillator array designed and built for in line treatment verification. The purpose of this project is to assess the capability of the fiber detector array technology to detect treatment errors in real time without false positives to enhance patient saf...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735217
更新日期:2012-06-01 00:00:00
abstract::A new calibration algorithm (GLAaS) to derive absolute dose maps from images acquired with the Varian PV-aS500 electronic portal imager (based on amorphous silicon detectors) has been developed incorporating the dependence of detector response on primary and transmitted radiation and on field size. Detector calibratio...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2218314
更新日期:2006-08-01 00:00:00
abstract::Computed tomography dose index (CTDI) is a conventional indicator of the patient dose in CT studies. It is measured as the integration of the longitudinal single scan dose profile (SSDP) by using a 100-mm-long pencil ionization chamber and a single axial scan. However, the assumption that most of the SSDP is contained...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1835571
更新日期:2005-01-01 00:00:00
abstract:PURPOSE:High-spatial-resolution x-ray imaging in the few-ten-keV range is becoming increasingly important in several applications, such as small-animal imaging and phase-contrast imaging. The detector properties critically influence the quality of such imaging. Here the authors present a quantitative comparison of scin...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4948687
更新日期:2016-06-01 00:00:00
abstract::MR acoustic radiation force (ARF) imaging was developed for measuring tiSsue elastic properties using focused ultrasound to deliver a localized tissue motion. In this study, an imaging ultrasound transducer was mounted on the focused ultrasound transducer and ultrasound motion tracking was performed simultaneously to ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3120289
更新日期:2009-06-01 00:00:00
abstract::Some limitations of conventional two-dimensional computer programs used to plan radiation therapy are presented. These include: a lack of involvement in defining the clinical problem; deficiencies in the algorithms for computing dose; failure to compute dose throughout the volume of interest; an inability to handle tr...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595226
更新日期:1982-07-01 00:00:00
abstract:PURPOSE:This study (1) examines a variety of real-world cases where systematic errors were not detected by widely accepted methods for IMRT/VMAT dosimetric accuracy evaluation, and (2) drills-down to identify failure modes and their corresponding means for detection, diagnosis, and mitigation. The primary goal of detai...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4826166
更新日期:2013-11-01 00:00:00
abstract:PURPOSE:To evaluate two deformable image registration (DIR) algorithms for the purpose of contour mapping to support image guided adaptive radiotherapy (IGART) with 4D cone beam CT (4DCBCT). METHODS:Eleven locally advanced non-small cell lung cancer (NSCLC) patients underwent one planning 4D fan- beam CT (4DFBCT) and ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735821
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:Volumetric x-ray microcomputed tomography (CT) can be employed in a variety of quantitative research applications such as image-guided interventions or characterization of medical devices. To ensure the highest geometric fidelity of images for these applications, a phantom and image processing algorithm have be...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4752083
更新日期:2012-10-01 00:00:00
abstract:PURPOSE:To evaluate the image quality of virtual monochromatic images synthesized from dual-source dual-energy computed tomography (CT) in comparison with conventional polychromatic single-energy CT for the same radiation dose. METHODS:In dual-energy CT, besides the material-specific information, one may also synthesi...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3658568
更新日期:2011-12-01 00:00:00