Development and validation of a CT-3D rotational angiography registration method for AVM radiosurgery.

Abstract:

:In this paper a novel technique is proposed and validated for radiosurgery treatment planning of arteriovenous malformations (AVMs). The technique was developed for frameless radiosurgery by means of the CyberKnife, a nonisocentric, linac-based system which allows highly conformed isodose surfaces to be obtained, while also being valid for other treatment strategies. The technique is based on registration between computed tomography (CT) and three-dimensional rotational angiography (3DRA). Tests were initially performed on the effectiveness of the correction method for distortion offered by the angiographic system. These results determined the registration technique that was ultimately chosen. For CT-3DRA registration, a twelve-parameter affine transformation was selected, based on a mutual information maximization algorithm. The robustness of the algorithm was tested by attempting to register data sets increasingly distant from each other, both in translation and rotation. Registration accuracy was estimated by means of the "full circle consistency test." A registration quality index (expressed in millimeters) based on these results was also defined. A hybrid subtraction between CT and 3DRA is proposed in order to improve 3D reconstruction. Preprocessing improved the ability of the algorithm to find an acceptable solution to the registration process. The robustness tests showed that data sets must be manually prealigned within approximately 15 mm and 20 degrees with respect to all three directions simultaneously. Results of the consistency test showed agreement between the quality index and registration accuracy stated by visual inspection in 20 good and 10 artificially worsened registration processes. The quality index showed values smaller than the maximum voxel size (mean 0.8 mm compared to 2 mm) for all successful registrations, while it resulted in much greater values (mean 20 mm) for unsuccessful registrations. Once registered, the two data sets can be used for CyberKnife treatment planning. Target delineation is performed on 3DRA while dose calculation and DRR generation are performed on CT. In conclusion, a method was developed for using 3DRA images for AVM frameless radiosurgery treatment planning. The method proved to be feasible, robust, and accurate for clinical use. 3DRA can be performed at different times or locations compared to standard, frame based stereotactic angiography. Unlike two-dimensional angiography, 3DRA allows examination of the shape of the AVM and of the surrounding target from any arbitrary point of view during treatment planning. The method can be applied to any case of intermodality registration, is operator-independent, and allows estimation of registration quality. Further research is desirable to improve time resolution in order to distinguish between feeding and draining vessels.

journal_name

Med Phys

journal_title

Medical physics

authors

Stancanello J,Cavedon C,Francescon P,Cerveri P,Ferrigno G,Colombo F,Perini S

doi

10.1118/1.1751252

subject

Has Abstract

pub_date

2004-06-01 00:00:00

pages

1363-71

issue

6

eissn

0094-2405

issn

2473-4209

journal_volume

31

pub_type

杂志文章
  • Region-oriented CT image representation for reducing computing time of Monte Carlo simulations.

    abstract:PURPOSE:We propose a new method for efficient particle transportation in voxelized geometry for Monte Carlo simulations. We describe its use for calculating dose distribution in CT images for radiation therapy. MATERIAL AND METHODS:The proposed approach, based on an implicit volume representation named segmented volum...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2884854

    authors: Sarrut D,Guigues L

    更新日期:2008-04-01 00:00:00

  • Imaging of radiation dose by visible color development in ferrous-agarose-xylenol orange gels.

    abstract::Imaging of radiation dose distribution in gel phantoms by magnetic resonance techniques has previously been reported. In this paper a method of producing gels in which the distributions of radiation dose can also be visualized as a color change is reported. The color developed depends qualitatively and quantitatively ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596676

    authors: Appleby A,Leghrouz A

    更新日期:1991-03-01 00:00:00

  • CeBr3 scintillators for 4 He prompt gamma spectroscopy: Results from a Monte Carlo optimization study.

    abstract:PURPOSE:Range uncertainties limit the potential of charged particle therapy. In vivo and online range verification techniques could increase the confidence in the dose delivery distribution and lead to more conformal treatments. Prompt gamma imaging and prompt gamma spectroscopy (PGS) have been demonstrated for such a ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12795

    authors: Dal Bello R,Magalhaes Martins P,Seco J

    更新日期:2018-04-01 00:00:00

  • Low dose fraction behavior of high sensitivity radiochromic film.

    abstract::A high sensitivity (HS) model of radiochromic film is receiving increasing use. The film's linear sensitometric response in the range of 0.5-40 Gy would make this film an ideal candidate for complex dosimetry applications that require tissue equivalence. This study investigates the potential use for clinical dosimetry...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1883565

    authors: Hirata EY,Cunningham C,Micka JA,Keller H,Kissick MW,DeWerd LA

    更新日期:2005-04-01 00:00:00

  • Reconstruction of diagnostic x-ray spectra by numerical analysis of transmission data.

    abstract::Numerical reconstruction of x-ray spectra from narrow-beam transmission data was tested with published spectra in the range from 45 to 100 kVp. Transmission curves were calculated from the spectra to simulate measured data. Spectra were reconstructed from these transmission curves with use of an iterative numerical an...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595834

    authors: Huang PH,Chen TS,Kase KR

    更新日期:1986-09-01 00:00:00

  • 4D rotational x-ray imaging of wrist joint dynamic motion.

    abstract::Current methods for imaging joint motion are limited to either two-dimensional (2D) video fluoroscopy, or to animated motions from a series of static three-dimensional (3D) images. 3D movement patterns can be detected from biplane fluoroscopy images matched with computed tomography images. This involves several x-ray ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2000647

    authors: Carelsen B,Bakker NH,Strackee SD,Boon SN,Maas M,Sabczynski J,Grimbergen CA,Streekstra GJ

    更新日期:2005-09-01 00:00:00

  • Discriminating solitary cysts from soft tissue lesions in mammography using a pretrained deep convolutional neural network.

    abstract:PURPOSE:It is estimated that 7% of women in the western world will develop palpable breast cysts in their lifetime. Even though cysts have been correlated with risk of developing breast cancer, many of them are benign and do not require follow-up. We develop a method to discriminate benign solitary cysts from malignant...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12110

    authors: Kooi T,van Ginneken B,Karssemeijer N,den Heeten A

    更新日期:2017-03-01 00:00:00

  • SU-E-T-264: New Concrete Designed and Evaluation for Megavoltage X Radiotherapy Facilities (CONTEK-RFH2).

    abstract:PURPOSE:The most common material for shielding is concrete, which can be made using various materials of different densities as aggregates. New techniques in radiotherapy, as IMRT and VMAT, require more monitor units and it is important to develop specifically designed shielding materials. METHODS:Arraela S.L. has dev...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735331

    authors: Mera M,Pereira L,Mera M,Pereira L,Meilán E,Moral FD,Teijeiro A,Salgado M,Andrade B,Gomez F,Fuentes-Vázquez V,Caruncho J,Medina A

    更新日期:2012-06-01 00:00:00

  • On the effective point of measurement in megavoltage photon beams.

    abstract::This paper presents a numerical investigation of the effective point of measurement of thimble ionization chambers in megavoltage photon beams using Monte Carlo simulations with the EGSNRC system. It is shown that the effective point of measurement for relative photon beam dosimetry depends on every detail of the cham...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2201147

    authors: Kawrakow I

    更新日期:2006-06-01 00:00:00

  • Accurate measurement of characteristic curves of II-TV digital systems by use of aluminum stepwedge technique.

    abstract::In order to determine accurately the relative x-ray intensities transmitted through the different steps of an aluminum stepwedge and incident on an image intensifier (II)-TV digital system, we used a 100-mm camera which was attached to the II output. The characteristic curves of an II-TV digital system, which relate t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595819

    authors: Fujita H,Doi K

    更新日期:1986-11-01 00:00:00

  • Variability of tumor area measurements for response assessment in malignant pleural mesothelioma.

    abstract:PURPOSE:The measurement of malignant pleural mesothelioma is critical to the assessment of tumor response to therapy. Current response assessment standards utilize summed linear measurements acquired on three computed tomography (CT) sections. The purpose of this study was to evaluate manual area measurements as an alt...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4810940

    authors: Labby ZE,Straus C,Caligiuri P,MacMahon H,Li P,Funaki A,Kindler HL,Armato SG 3rd

    更新日期:2013-08-01 00:00:00

  • Direct data link between a CT scanner and a radiation treatment planning system.

    abstract::A direct data link between a CT scanner and a radiation treatment planning system has been developed. The link transmits the data serially over a coaxial cable using the pseudo-paper-tape punch and reader (serial PIO) interfaces. The data transmission rate with error-check is approximately 25,000 8-bit bytes/s. This t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594536

    authors: Abel RN,Buhler LA,Chu WT,Slater JM,Neilsen IR,Zimmerman DC

    更新日期:1979-09-01 00:00:00

  • Ytterbium-169: calculated physical properties of a new radiation source for brachytherapy.

    abstract::Seeds containing radioactive Ytterbium-169 (169Yb) have recently been manufactured for possible application to brachytherapy. Ytterbium-169 emits photons with an average energy of 93 keV (excluding energies less than 10 keV), and decays with a half-life of 32 days. Analytic and Monte Carlo computations have been used ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596813

    authors: Mason DL,Battista JJ,Barnett RB,Porter AT

    更新日期:1992-05-01 00:00:00

  • Tomotherapy dose distribution verification using MAGIC-f polymer gel dosimetry.

    abstract:PURPOSE:This paper presents the application of MAGIC-f gel in a three-dimensional dose distribution measurement and its ability to accurately measure the dose distribution from a tomotherapy unit. METHODS:A prostate intensity-modulated radiation therapy (IMRT) irradiation was simulated in the gel phantom and the treat...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4704496

    authors: Pavoni JF,Pike TL,Snow J,DeWerd L,Baffa O

    更新日期:2012-05-01 00:00:00

  • A new data augmentation method based on local image warping for medical image segmentation.

    abstract:PURPOSE:The segmentation accuracy of medical images was improved by increasing the number of training samples using a local image warping technique. The performance of the proposed method was evaluated in the segmentation of breast masses, prostate and brain tumors, and lung nodules. METHODS:We propose a simple data a...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14651

    authors: Liu H,Cao H,Song E,Ma G,Xu X,Jin R,Liu T,Liu L,Liu D,Hung CC

    更新日期:2020-12-10 00:00:00

  • Eye tracking and gating system for proton therapy of orbital tumors.

    abstract:PURPOSE:A new motion-based gated proton therapy for the treatment of orbital tumors using real-time eye-tracking system was designed and evaluated. METHODS:We developed our system by image-pattern matching, using a normalized cross-correlation technique with LabVIEW 8.6 and Vision Assistant 8.6 (National Instruments, ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4729708

    authors: Shin D,Yoo SH,Moon SH,Yoon M,Lee SB,Park SY

    更新日期:2012-07-01 00:00:00

  • Volumetric breast density evaluation from ultrasound tomography images.

    abstract::Previous ultrasound tomography work conducted by our group showed a direct correlation between measured sound speed and physical density in vitro, and increased in vivo sound speed with increasing mammographic density, a known risk factor for breast cancer. Building on these empirical results, the purpose of this work...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2964092

    authors: Glide-Hurst CK,Duric N,Littrup P

    更新日期:2008-09-01 00:00:00

  • Image reconstruction for positron emission tomography based on patch-based regularization and dictionary learning.

    abstract:PURPOSE:Positron emission tomography (PET) is an important tool for nuclear medical imaging. It has been widely used in clinical diagnosis, scientific research, and drug testing. PET is a kind of emission computed tomography. Its basic imaging principle is to use the positron annihilation radiation generated by radionu...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13804

    authors: Zhang W,Gao J,Yang Y,Liang D,Liu X,Zheng H,Hu Z

    更新日期:2019-11-01 00:00:00

  • Tree structured wavelet transform segmentation of microcalcifications in digital mammography.

    abstract::A novel multistage algorithm is proposed for the automatic segmentation of microcalcification clusters (MCCs) in digital mammography. First, a previously reported tree structured nonlinear filter is proposed for suppressing image noise, while preserving image details, to potentially reduce the false positive (FP) dete...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597562

    authors: Qian W,Kallergi M,Clarke LP,Li HD,Venugopal P,Song D,Clark RA

    更新日期:1995-08-01 00:00:00

  • Application of radiomics for the prediction of HPV status for patients with head and neck cancers.

    abstract:PURPOSE:To perform radiomic analysis of primary tumors extracted from pretreatment contrast-enhanced computed tomography (CE-CT) images for patients with oropharyngeal cancers to identify discriminant features and construct an optimal classifier for the characterization and prediction of human papilloma virus (HPV) sta...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13977

    authors: Bagher-Ebadian H,Lu M,Siddiqui F,Ghanem AI,Wen N,Wu Q,Liu C,Movsas B,Chetty IJ

    更新日期:2020-02-01 00:00:00

  • Ethics and professionalism in medical physics: a survey of AAPM members.

    abstract:PURPOSE:To assess current education, practices, attitudes, and perceptions pertaining to ethics and professionalism in medical physics. METHODS:A link to a web-based survey was distributed to the American Association of Physicists in Medicine (AAPM) e-mail membership list, with a follow-up e-mail sent two weeks later....

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4797463

    authors: Ozturk N,Armato SG 3rd,Giger ML,Serago CF,Ross LF

    更新日期:2013-04-01 00:00:00

  • X-ray spectral reconstruction from attenuation data using neural networks.

    abstract::An artificial neural network using input data derived from attenuation measurements was trained to generate spectral profiles (relative number of photons versus energy). Once the relative spectral distribution is reconstructed, absolute spectra (number of photons per unit exposure spectral distribution is reconstructe...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596495

    authors: Boone JM

    更新日期:1990-07-01 00:00:00

  • Voxel clustering for quantifying PET-based treatment response assessment.

    abstract:PURPOSE:Imaging biomarkers are crucial in managing treatment options for cancer patients. They are extremely powerful tools since they allow personalized treatment assessment early during therapy by using repeated imaging to detect and quantify tumor response. Currently, treatment response assessment from consecutive i...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4764900

    authors: Schreibmann E,Waller AF,Crocker I,Curran W,Fox T

    更新日期:2013-01-01 00:00:00

  • Influence of cold walls on PET image quantification and volume segmentation: a phantom study.

    abstract:PURPOSE:Commercially available fillable plastic inserts used in positron emission tomography phantoms usually have thick plastic walls, separating their content from the background activity. These "cold" walls can modify the intensity values of neighboring active regions due to the partial volume effect, resulting in e...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4813302

    authors: Berthon B,Marshall C,Edwards A,Evans M,Spezi E

    更新日期:2013-08-01 00:00:00

  • Characterization of tissue-specific pre-log Bayesian CT reconstruction by texture-dose relationship.

    abstract:PURPOSE:Tissue textures have been recognized as biomarkers for various clinical tasks. In computed tomography (CT) image reconstruction, it is important but challenging to preserve the texture when lowering x-ray exposure from full- toward low-/ultra-low dose level. Therefore, this paper aims to explore the texture-dos...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14449

    authors: Gao Y,Liang Z,Xing Y,Zhang H,Pomeroy M,Lu S,Ma J,Lu H,Moore W

    更新日期:2020-10-01 00:00:00

  • Effect of respiratory motion on the delivery of breast radiotherapy using SMLC intensity modulation.

    abstract::This study evaluates the effects of respiratory motion on breast radiotherapy delivered using segmented multileaf collimator (SMLC) intensity modulation. An anthropomorphic breast phantom was constructed of polystyrene plates between which radiographic films were inserted. The phantom was mounted on a moving platform ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2405323

    authors: Liu Q,McDermott P,Burmeister J

    更新日期:2007-01-01 00:00:00

  • Liquid ionization chambers for absorbed dose measurements in water at low dose rates and intermediate photon energies.

    abstract::Two new liquid ionization chamber (LIC) designs, consisting of cylindrical and plane-parallel configurations, are presented. They are designed to be suitable for high-precision measurements of absorbed dose-to-water at dose rates and photon energies typical for LDR intermediate photon energy brachytherapy sources. The...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598268

    authors: Wickman G,Johansson B,Bahar-Gogani J,Holmström T,Grindborg JE

    更新日期:1998-06-01 00:00:00

  • MO-F-213AB-01: Improving Dose Uniformity in Patch-Field Proton Therapy Using Beam Current Modulation.

    abstract:PURPOSE:To improve the dose homogeneity in patch-field proton therapy using beam current modulation. METHODS:MCNPX simulations were performed for various configurations of the Mevion S250 beamline. Spread-out Bragg peak (SOBP) dose distributions were calculated, and lateral and distal dose profiles were extracted for ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735806

    authors: Hill P,Klein E,Bloch C

    更新日期:2012-06-01 00:00:00

  • Reliability of water proton chemical shift temperature calibration for focused ultrasound ablation therapy.

    abstract::Our purpose in this work was to assess the reliability of the calibration coefficient for magnetic resonance water proton chemical shift temperature mapping. Over a six month period, the calibration coefficient was measured 15 times in several different phantoms. A highly linear relationship between water proton chemi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598864

    authors: Wu T,Kendell KR,Felmlee JP,Lewis BD,Ehman RL

    更新日期:2000-01-01 00:00:00

  • Simultaneous super-resolution and contrast synthesis of routine clinical magnetic resonance images of the knee for improving automatic segmentation of joint cartilage: data from the Osteoarthritis Initiative.

    abstract:PURPOSE:High resolution three-dimensional (3D) magnetic resonance (MR) images are well suited for automated cartilage segmentation in the human knee joint. However, volumetric scans such as 3D Double-Echo Steady-State (DESS) images are not routinely acquired in clinical practice which limits opportunities for reliable ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14421

    authors: Neubert A,Bourgeat P,Wood J,Engstrom C,Chandra SS,Crozier S,Fripp J

    更新日期:2020-10-01 00:00:00