Development of PET/MRI with insertable PET for simultaneous PET and MR imaging of human brain.

Abstract:

PURPOSE:The purpose of this study was to develop a dual-modality positron emission tomography (PET)/magnetic resonance imaging (MRI) with insertable PET for simultaneous PET and MR imaging of the human brain. METHODS:The PET detector block was composed of a 4 × 4 matrix of detector modules, each consisting of a 4 × 4 array LYSO coupled to a 4 × 4 Geiger-mode avalanche photodiode (GAPD) array. The PET insert consisted of 18 detector blocks, circularly mounted on a custom-made plastic base to form a ring with an inner diameter of 390 mm and axial length of 60 mm. The PET gantry was shielded with gold-plated conductive fabric tapes with a thickness of 0.1 mm. The charge signals of PET detector transferred via 4 m long flat cables were fed into the position decoder circuit. The flat cables were shielded with a mesh-type aluminum sheet with a thickness of 0.24 mm. The position decoder circuit and field programmable gate array-embedded DAQ modules were enclosed in an aluminum box with a thickness of 10 mm and located at the rear of the MR bore inside the MRI room. A 3-T human MRI system with a Larmor frequency of 123.7 MHz and inner bore diameter of 60 cm was used as the PET/MRI hybrid system. A custom-made radio frequency (RF) coil with an inner diameter of 25 cm was fabricated. The PET was positioned between gradient and the RF coils. PET performance was measured outside and inside the MRI scanner using echo planar imaging, spin echo, turbo spin echo, and gradient echo sequences. MRI performance was also evaluated with and without the PET insert. The stability of the newly developed PET insert was evaluated and simultaneous PET and MR images of a brain phantom were acquired. RESULTS:No significant degradation of the PET performance caused by MR was observed when the PET was operated using various MR imaging sequences. The signal-to-noise ratio of MR images was slightly degraded due to the PET insert installed inside the MR bore while the homogeneity was maintained. The change of gain of the 256 GAPD/scintillator elements of a detector block was <3% for 60 min, and simultaneous PET and MR images of a brain phantom were successfully acquired. CONCLUSIONS:Experimental results indicate that a compact and lightweight PET insert for hybrid PET/MRI can be developed using GAPD arrays and charge signal transmission method proposed in this study without significant interference.

journal_name

Med Phys

journal_title

Medical physics

authors

Jung JH,Choi Y,Jung J,Kim S,Lim HK,Im KC,Oh CH,Park HW,Kim KM,Kim JG

doi

10.1118/1.4918321

subject

Has Abstract

pub_date

2015-05-01 00:00:00

pages

2354-63

issue

5

eissn

0094-2405

issn

2473-4209

journal_volume

42

pub_type

杂志文章
  • Delivery validation of an automated modulated electron radiotherapy plan.

    abstract:PURPOSE:Modulated electron radiation therapy (MERT) represents an active area of interest that offers the potential to improve healthy tissue sparing in treatment of certain cancer cases. Challenges remain however in accurate beamlet dose calculation, plan optimization, collimation method, and delivery accuracy. In thi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4876297

    authors: Connell T,Alexander A,Papaconstadopoulos P,Serban M,Devic S,Seuntjens J

    更新日期:2014-06-01 00:00:00

  • Shimming with permanent magnets for the x-ray detector in a hybrid x-ray/ MR system.

    abstract::In this x-ray/MR hybrid system an x-ray flat panel detector is placed under the patient cradle, close to the MR volume of interest (VOI), where the magnetic field strength is approximately 0.5 T. Immersed in this strong field, several electronic components inside the detector become magnetized and create an additional...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2963994

    authors: Wen Z,Fahrig R,Williams ST,Pelc NJ

    更新日期:2008-09-01 00:00:00

  • Displacement and strain estimation for evaluation of arterial wall stiffness using a familial hypercholesterolemia swine model of atherosclerosis.

    abstract:PURPOSE:To track variations in the deformation of the arterial wall noninvasively by estimating the accumulated displacement and strain over a cardiac cycle may provide useful indicators of vascular health. METHODS:In this paper, we propose an approach to track a region of interest (ROI) locally and estimate arterial ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4722746

    authors: Ge W,Krueger CG,Weichmann A,Shanmuganayagam D,Varghese T

    更新日期:2012-07-01 00:00:00

  • SU-E-T-04: Repair Kinetics of Sublethal Damage in Rat Cervical Spinal Cord - Application of the GLQ Model Incorporating Reciprocal Time Pattern.

    abstract:PURPOSE:The repair rate conventionally assumed to be constant during the entire radiation course. However, increasing evidences from animal studies show that the repair process may slow down with time and the experimental data does not fit an exponential pattern. To address this enigma, we presented a generalized linea...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735058

    authors: Huang Z,Mayr NA,Lo SS,McLawhorn R,Gao M,Liu T,Yuh W

    更新日期:2012-06-01 00:00:00

  • Compensator models for fluence field modulated computed tomography.

    abstract:PURPOSE:Fluence field modulated computed tomography (FFMCT) presents a novel approach for acquiring CT images, whereby a patient model guides dynamically changing fluence patterns in an attempt to achieve task-based, user-prescribed, regional variations in image quality, while also controlling dose to the patient. This...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4829513

    authors: Bartolac S,Jaffray D

    更新日期:2013-12-01 00:00:00

  • Computer-aided measurement of liver volumes in CT by means of geodesic active contour segmentation coupled with level-set algorithms.

    abstract:PURPOSE:Computerized liver extraction from hepatic CT images is challenging because the liver often abuts other organs of a similar density. The purpose of this study was to develop a computer-aided measurement of liver volumes in hepatic CT. METHODS:The authors developed a computerized liver extraction scheme based o...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3395579

    authors: Suzuki K,Kohlbrenner R,Epstein ML,Obajuluwa AM,Xu J,Hori M

    更新日期:2010-05-01 00:00:00

  • Low dose fraction behavior of high sensitivity radiochromic film.

    abstract::A high sensitivity (HS) model of radiochromic film is receiving increasing use. The film's linear sensitometric response in the range of 0.5-40 Gy would make this film an ideal candidate for complex dosimetry applications that require tissue equivalence. This study investigates the potential use for clinical dosimetry...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1883565

    authors: Hirata EY,Cunningham C,Micka JA,Keller H,Kissick MW,DeWerd LA

    更新日期:2005-04-01 00:00:00

  • A numerical study of the acoustic radiation due to eddy current-cryostat interactions.

    abstract:PURPOSE:To investigate the acoustic radiation due to eddy current-cryostat interactions and perform a qualitative analysis on noise reduction methods. METHODS:In order to evaluate the sound pressure level (SPL) of the eddy current induced warm bore wall vibration, a Finite Element (FE) model was created to simulate th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12261

    authors: Wang Y,Liu F,Zhou X,Li Y,Crozier S

    更新日期:2017-06-01 00:00:00

  • Technical Note: Automatic segmentation of CT images for ventral body composition analysis.

    abstract:PURPOSE:Body composition is known to be associated with many diseases including diabetes, cancers, and cardiovascular diseases. In this paper, we developed a fully automatic body tissue decomposition procedure to segment three major compartments that are related to body composition analysis - subcutaneous adipose tissu...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14465

    authors: Fu Y,Ippolito JE,Ludwig DR,Nizamuddin R,Li HH,Yang D

    更新日期:2020-11-01 00:00:00

  • Development and implementation of EPID-based quality assurance tests for the small animal radiation research platform (SARRP).

    abstract:PURPOSE:Although small animal image-guided radiotherapy (SA-IGRT) systems are used increasingly in preclinical research, tools for performing routine quality assurance (QA) have not been optimized and are not readily available. Robust, efficient, and reliable QA tools are needed to ensure the accuracy and reproducibili...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12939

    authors: Anvari A,Poirier Y,Sawant A

    更新日期:2018-07-01 00:00:00

  • A comparative contrast-detail study of five medical displays.

    abstract::The objective of this study was to compare the contrast-detail performance of five different commercial liquid crystal displays (LCDs) to other LCD and cathode-ray tube (CRT) displays for medical applications. A contrast-detail phantom, supplemented with 5 in. of acrylic, was imaged on a commercial digital radiographi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2868780

    authors: Samei E,Ranger NT,Delong DM

    更新日期:2008-04-01 00:00:00

  • Use of proximal operator graph solver for radiation therapy inverse treatment planning.

    abstract:PURPOSE:Most radiation therapy optimization problems can be formulated as an unconstrained problem and solved efficiently by quasi-Newton methods such as the Limited-memory Broyden-Fletcher-Goldfarb-Shanno (L-BFGS) algorithm. However, several next generation planning techniques such as total variation regularization- b...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12165

    authors: Liu X,Pelizzari C,Belcher AH,Grelewicz Z,Wiersma RD

    更新日期:2017-04-01 00:00:00

  • An optimized ultrasound detector for photoacoustic breast tomography.

    abstract:PURPOSE:Photoacoustic imaging has proven to be able to detect vascularization-driven optical absorption contrast associated with tumors. In order to detect breast tumors located a few centimeter deep in tissue, a sensitive ultrasound detector is of crucial importance for photoacoustic mammography. Further, because the ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4792462

    authors: Xia W,Piras D,van Hespen JC,van Veldhoven S,Prins C,van Leeuwen TG,Steenbergen W,Manohar S

    更新日期:2013-03-01 00:00:00

  • Optimized knot placement for B-splines in deformable image registration.

    abstract:PURPOSE:To develop an automatic knot placement algorithm to enable the use of NonUniform Rational B-Splines (NURBS) in deformable image registration. METHODS:The authors developed a two-step approach to fit a known displacement vector field (DVF). An initial fit was made with uniform knot spacing. The error generated ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3609416

    authors: Jacobson TJ,Murphy MJ

    更新日期:2011-08-01 00:00:00

  • An experimental palladium-103 seed (OptiSeedexp) in a biocompatible polymer without a gold marker: characterization of dosimetric parameters including the interseed effect.

    abstract::Permanent implantation of 125I (iodine) or 103Pd (palladium) sources is a popular treatment option in the management of early stage prostate cancer. New sources are being developed, some of which are being marketed for different clinical applications. A new technique of adjuvant stereotactic permanent seed breast impl...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3006151

    authors: Abboud F,Scalliet P,Vynckier S

    更新日期:2008-12-01 00:00:00

  • Quantitative impact of changes in marrow cellularity, skeletal size, and bone mineral density on active marrow dosimetry based upon a reference model.

    abstract:PURPOSE:The hematopoietically active tissues of skeletal bone marrow are a prime target for computational dosimetry given potential risks of leukemia and, at higher dose levels, acute marrow toxicity. The complex three-dimensional geometry of trabecular spongiosa, however, complicates schema for dose assessment in such...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12002

    authors: Geyer AM,Schwarz BC,Hobbs RF,Sgouros G,Bolch WE

    更新日期:2017-01-01 00:00:00

  • Dual-film cassette technique for studying the effect of radiographic image quality on diagnostic accuracy.

    abstract::In order to investigate the relationship between diagnostic accuracy and radiographic image quality, we have developed a dual-film cassette which produces two radiographs simultaneously with a single exposure. One of these radiographs is of standard quality; the second is of lower quality because of degraded spatial r...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595546

    authors: Higashida Y,Doi K,Lehr JL,MacMahon H

    更新日期:1984-09-01 00:00:00

  • Comparison of ROC and AFC methods in a visual detection task.

    abstract::The visual observer performance for detecting low-contrast patterns by employing both the receiver operating characteristic (ROC) and the 9-alternative forced choice (9-AFC) method is investigated. For each observer and each experimental technique, the results were reproducible with respect to a repeated observation. ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596986

    authors: Herrmann C,Buhr E,Hoeschen D,Fan SY

    更新日期:1993-05-01 00:00:00

  • Multileaf collimator performance monitoring and improvement using semiautomated quality control testing and statistical process control.

    abstract:PURPOSE:High-quality radiation therapy using highly conformal dose distributions and image-guided techniques requires optimum machine delivery performance. In this work, a monitoring system for multileaf collimator (MLC) performance, integrating semiautomated MLC quality control (QC) tests and statistical process contr...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4901520

    authors: Létourneau D,Wang A,Amin MN,Pearce J,McNiven A,Keller H,Norrlinger B,Jaffray DA

    更新日期:2014-12-01 00:00:00

  • Angular measurement of the cobalt-60 emitted radiation spectrum from a radiosurgery irradiator.

    abstract::The photon energy spectrum emanating from a Leksell Gamma Knife, Model 23004B, was measured between 0.250 and 3.5 MeV with the sources exposed. Measurements were made using a 2x2 inch NaI detector enclosed in a lead-shielded apparatus having a 1/4 inch diameter measurement aperture, which reduced the amount of radiati...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1355305

    authors: Drzymala RE,Sohn JW,Guo C,Sobotka LG,Purdy JA

    更新日期:2001-04-01 00:00:00

  • The accuracy of SPECT brain activation images: propagation of registration errors.

    abstract::Functional single photon emission computed tomography (SPECT) images of brain activation are based on a comparison of base line and activation images. The correctness of the functional images depends, among other factors, on the accurate spatial registration (alignment) of the base line and activation image data. The ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597412

    authors: Sychra JJ,Pavel DG,Chen Y,Jani A

    更新日期:1994-10-01 00:00:00

  • SU-E-I-103: Detecting Anomalous Pixels and Correlated Artifacts in Digital Detectors from Flat-Field Images.

    abstract:PURPOSE:Anomalous pixels may be defined as those pixels whose exposure response relationship is deviant from the typical, expected or calibrated response. A group of anomalous pixels may Result in visible correlated artifacts. Here we demonstrate an approach to identify anomalous pixels and correlated artifacts using f...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734820

    authors: Dave J,Gingold E,Yorkston J,Bercha I,Goldman L,Walz-Flannigan A,Willis C

    更新日期:2012-06-01 00:00:00

  • Analysis and correction of imperfections in the image intensifier-TV-digitizer imaging chain.

    abstract::Image intensifier-television-video digitizer (IITVD) systems are commonly used for digital planar image acquisition in radiology. However, the well-known distortions inherent in these systems limit their utility in research and in some clinical applications where quantitatively correct images are required. Software co...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596718

    authors: Boone JM,Seibert JA,Barrett WA,Blood EA

    更新日期:1991-03-01 00:00:00

  • Effects of x-ray beam equalization on mammographic imaging.

    abstract::We employed an elastic reservoir filled with tissue-equivalent fluid as an x-ray beam filter for exposure equalization. The filter is designed to be placed between the upper compression plate and the breast. During compression, it will conform to the shape of the peripheral region of the breast and fill the space betw...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596502

    authors: Lam KL,Chan HP

    更新日期:1990-03-01 00:00:00

  • Rotationally resliced 3D prostate TRUS segmentation using convex optimization with shape priors.

    abstract:PURPOSE:Efficient and accurate segmentations of 3D end-firing transrectal ultrasound (TRUS) images play an important role in planning of 3D TRUS guided prostate biopsy. However, poor image quality of the input 3D TRUS images, such as strong imaging artifacts and speckles, often makes it a challenging task to extract th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4906129

    authors: Qiu W,Yuan J,Ukwatta E,Fenster A

    更新日期:2015-02-01 00:00:00

  • A mouse radiation-induced liver disease model for stereotactic body radiation therapy validated in patients with hepatocellular carcinoma.

    abstract:PURPOSE:Lower radiation tolerance of the whole liver hinders dose escalations of stereotactic body radiation therapy (SBRT) in hepatocellular carcinoma (HCC) treatment. This study was conducted to define the exact doses that result in radiation-induced liver disease (RILD) as well as to determine dose constraints for t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4953831

    authors: Wu ZF,Zhang JY,Shen XY,Zhou LY,Gao YB,Hu Y,Zeng ZC

    更新日期:2016-07-01 00:00:00

  • SU-E-T-269: The Evaluation of Copper as an Alternative for Cerrobend Electron Shielding.

    abstract:PURPOSE:To evaluate the replacement of Cerrobend by copper for electron beam cutouts. METHODS:The dosimetric comparisons for circular copper-and Cerrobend-cutouts with diameters (1.0, 2.0, 3.0, 5.0, 7.5, 10.0, and 12.5 cm) were made using electron beams with energies (6, 9, 12, 16, and 20 MeV) from 3 Varian accelerato...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735336

    authors: Chu A,Feng W,Ahmad M,Chen Z,Nath R

    更新日期:2012-06-01 00:00:00

  • Low-complexity atlas-based prostate segmentation by combining global, regional, and local metrics.

    abstract:PURPOSE:To improve the efficiency of atlas-based segmentation without compromising accuracy, and to demonstrate the validity of the proposed method on MRI-based prostate segmentation application. METHODS:Accurate and efficient automatic structure segmentation is an important task in medical image processing. Atlas-bas...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4867855

    authors: Xie Q,Ruan D

    更新日期:2014-04-01 00:00:00

  • Interleaf leakage for 5 and 10 mm dynamic multileaf collimation systems incorporating patient motion.

    abstract::Use of dynamic multileaf collimation (DMLC) for intensity modulated radiation therapy (IMRT) is accelerating. Delivery systems have the ailment of interleaf leakage (IL). This is compounded by the inefficiency of IMRT delivery, estimated to be a factor of 5 for DMLC. With IL on the order of 4%, it is possible to deliv...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1388216

    authors: Klein EE,Low DA

    更新日期:2001-08-01 00:00:00

  • Dosimetric accuracy of Kodak EDR2 film for IMRT verifications.

    abstract::Patient-specific intensity-modulated radiotherapy (IMRT) verifications require an accurate two-dimensional dosimeter that is not labor-intensive. We assessed the precision and reproducibility of film calibrations over time, measured the elemental composition of the film, measured the intermittency effect, and measured...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1852791

    authors: Childress NL,Salehpour M,Dong L,Bloch C,White RA,Rosen II

    更新日期:2005-02-01 00:00:00