Technical Note: Automatic segmentation of CT images for ventral body composition analysis.

Abstract:

PURPOSE:Body composition is known to be associated with many diseases including diabetes, cancers, and cardiovascular diseases. In this paper, we developed a fully automatic body tissue decomposition procedure to segment three major compartments that are related to body composition analysis - subcutaneous adipose tissue (SAT), visceral adipose tissue (VAT), and muscle. Three additional compartments - the ventral cavity, lung, and bones - were also segmented during the segmentation process to assist segmentation of the major compartments. METHODS:A convolutional neural network (CNN) model with densely connected layers was developed to perform ventral cavity segmentation. An image processing workflow was developed to segment the ventral cavity in any patient's computed tomography (CT) using the CNN model, then further segment the body tissue into multiple compartments using hysteresis thresholding followed by morphological operations. It is important to segment ventral cavity firstly to allow accurate separation of compartments with similar Hounsfield unit (HU) inside and outside the ventral cavity. RESULTS:The ventral cavity segmentation CNN model was trained and tested with manually labeled ventral cavities in 60 CTs. Dice scores (mean ± standard deviation) for ventral cavity segmentation were 0.966 ± 0.012. Tested on CT datasets with intravenous (IV) and oral contrast, the Dice scores were 0.96 ± 0.02, 0.94 ± 0.06, 0.96 ± 0.04, 0.95 ± 0.04, and 0.99 ± 0.01 for bone, VAT, SAT, muscle, and lung, respectively. The respective Dice scores were 0.97 ± 0.02, 0.94 ± 0.07, 0.93 ± 0.06, 0.91 ± 0.04, and 0.99 ± 0.01 for non-contrast CT datasets. CONCLUSION:A body tissue decomposition procedure was developed to automatically segment multiple compartments of the ventral body. The proposed method enables fully automated quantification of three-dimensional (3D) ventral body composition metrics from CT images.

journal_name

Med Phys

journal_title

Medical physics

authors

Fu Y,Ippolito JE,Ludwig DR,Nizamuddin R,Li HH,Yang D

doi

10.1002/mp.14465

subject

Has Abstract

pub_date

2020-11-01 00:00:00

pages

5723-5730

issue

11

eissn

0094-2405

issn

2473-4209

journal_volume

47

pub_type

杂志文章
  • Measurement of neutron ambient dose equivalent in passive carbon-ion and proton radiotherapies.

    abstract::Secondary neutron ambient dose equivalents per the treatment absorbed dose in passive carbon-ion and proton radiotherapies were measured using a rem meter, WENDI-II at two carbon-ion radiotherapy facilities and four proton radiotherapy facilities in Japan. Our measured results showed that (1) neutron ambient dose equi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2989019

    authors: Yonai S,Matsufuji N,Kanai T,Matsui Y,Matsushita K,Yamashita H,Numano M,Sakae T,Terunuma T,Nishio T,Kohno R,Akagi T

    更新日期:2008-11-01 00:00:00

  • Basic imaging properties of a computed radiographic system with photostimulable phosphors.

    abstract::We measured the characteristic curve, modulation transfer function (MTF), and the Wiener spectrum of a commercially available computed radiographic (CR) system with photostimulable phosphor plate (imaging plate, IP). The characteristic curve (system response) obtained by an inverse-square x-ray sensitometry showed a w...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596402

    authors: Fujita H,Ueda K,Morishita J,Fujikawa T,Ohtsuka A,Sai T

    更新日期:1989-01-01 00:00:00

  • The feasibility study and characterization of a two-dimensional diode array in "magic phantom" for high dose rate brachytherapy quality assurance.

    abstract:PURPOSE:High dose rate (HDR) brachytherapy is a radiation treatment technique capable of delivering large dose rates to the tumor. Radiation is delivered using remote afterloaders to drive highly active sources (commonly (192)Ir with an air KERMA strength range between 20,000 and 40,000 U, where 1 U = 1 μGy m(2)/h in a...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4822736

    authors: Espinoza A,Beeksma B,Petasecca M,Fuduli I,Porumb C,Cutajar D,Corde S,Jackson M,Lerch ML,Rosenfeld AB

    更新日期:2013-11-01 00:00:00

  • Unequal weighting of given doses in opposed fields in treatment of cancer of the tonsillar region using 60Co, 4-, 8-, 15-, 24-MVp photons.

    abstract::Weighting of given doses from parallel opposed fields is a widespread practice in radiation therapy of cancer in the tonsillar region. In order to determine when weighting is useful, dose distributions on the central axis were calculated for various energies (60Co, 4-, 8-, 15-, and MVp photons), weighting factors, and...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594276

    authors: Wollin M,Gilbert HA,Kagan AR

    更新日期:1976-03-01 00:00:00

  • Dosimetric aspects of a 3.3-MV linear accelerator.

    abstract::Both the design considerations and the dosimetric properties of the Siemens Model 5800 linear accelerator are discussed. This unit is of such an energy (3.3 MV) as to imitate Cobalt-60 teletherapy depth doses. A linear relation of dmax to depth dose at low energies was found for various wave guides and targets. The en...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596487

    authors: Steidley KD,Rosen CW

    更新日期:1990-05-01 00:00:00

  • The generalized geometry of eye plaque therapy.

    abstract::A calculation is described that enables the rapid assessment of dose rate at various points of interest within the eye (lens, optic nerve, etc.) for the treatment of choroidal melanoma by plaque therapy. 125I seeds are used as the radiation source. The location of the plaque and its associated seeds relative to the ey...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596234

    authors: Kepka AG,Johnson PM,Kline RW

    更新日期:1988-05-01 00:00:00

  • Accurate assessment and prediction of noise in clinical CT images.

    abstract:PURPOSE:The objectives of this study were (a) to devise a technique for measuring quantum noise in clinical body computed tomography (CT) images and (b) to develop a model for predicting that noise with high accuracy. METHODS:The study included 83 clinical image sets at two dose levels (clinical and 50% reduced dose l...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4938588

    authors: Tian X,Samei E

    更新日期:2016-01-01 00:00:00

  • Reference standard and statistical model for intersite and temporal comparisons of CT attenuation in a multicenter quantitative lung study.

    abstract:PURPOSE:The purpose of this study was to detect and analyze anomalies between a large number of computed tomography (CT) scanners, tracked over time, utilized to collect human pulmonary CT data for a national multicenter study: chronic obstructive pulmonary disease genetic epidemiology study (COPDGene). METHODS:A cust...

    journal_title:Medical physics

    pub_type: 杂志文章,多中心研究

    doi:10.1118/1.4747342

    authors: Sieren JP,Newell JD,Judy PF,Lynch DA,Chan KS,Guo J,Hoffman EA

    更新日期:2012-09-01 00:00:00

  • SU-E-T-476: GPU-Based Monte Carlo Radiotherapy Dose Calculation Using Phase- Space Sources.

    abstract:PURPOSE:To design an efficient method for utilizing phase-space source models in the GPU-based Monte Carlo (MC) dose calculation engine gDPM. METHODS:In GPU-based MC algorithms, particles are transported in parallel on different threads. Particles of different types and energies can require significantly different exe...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735565

    authors: Townson R,Jia X,Zavgorodni S,Jiang S

    更新日期:2012-06-01 00:00:00

  • Selective enhancement filters for nodules, vessels, and airway walls in two- and three-dimensional CT scans.

    abstract::Computer-aided diagnostic (CAD) schemes have been developed to assist radiologists in the early detection of lung cancer in radiographs and computed tomography (CT) images. In order to improve sensitivity for nodule detection, many researchers have employed a filter as a preprocessing step for enhancement of nodules. ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1581411

    authors: Li Q,Sone S,Doi K

    更新日期:2003-08-01 00:00:00

  • Automated segmentation of anatomic regions in chest radiographs using an adaptive-sized hybrid neural network.

    abstract::The purposes of this research are to investigate the effectiveness of our novel image features for segmentation of anatomic regions such as the lungs and the mediastinum in chest radiographs and to develop an automatic computerized method for image processing. A total of 85 screening chest radiographs from Johns Hopki...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598277

    authors: Tsujii O,Freedman MT,Mun SK

    更新日期:1998-06-01 00:00:00

  • B-spline active rays segmentation of microcalcifications in mammography.

    abstract::Accurate segmentation of microcalcifications in mammography is crucial for the quantification of morphologic properties by features incorporated in computer-aided diagnosis schemes. A novel segmentation method is proposed implementing active rays (polar-transformed active contours) on B-spline wavelet representation t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2991286

    authors: Arikidis NS,Skiadopoulos S,Karahaliou A,Likaki E,Panayiotakis G,Costaridou L

    更新日期:2008-11-01 00:00:00

  • Dual-energy x-ray projection imaging: two sampling schemes for the correction of scattered radiation.

    abstract::In addition to the familiar problems of reduced contrast and signal-to-noise ratio (SNR) in the single energy case, dual-energy subtractions in the presence of scattered radiation suffer further degradations from: (1) artifacts due to nonuniform subtraction of scatter, and (2) a serious deterioration of the signal of ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596188

    authors: Wagner FC,Macovski A,Nishimura DG

    更新日期:1988-09-01 00:00:00

  • SU-E-T-213: Development of a Web Wrapper to Facilitate Radiotherapy Research.

    abstract:PURPOSE:Researchers write many computer programs with unique implementations, usually requiring a great amount of effort for other researchers to learn how to install, configure, and use. Some programs require specialized hardware platforms such as GPU workstation or CPU cluster, which may not readily available for man...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735274

    authors: Folkerts M,Graves Y,Gautier Q,Kim G,Jia X,Jiang S

    更新日期:2012-06-01 00:00:00

  • Dosimetric problems at low monitor unit settings for scanned and scattering foil electron beams.

    abstract::Electron beam dosimetry at low monitor unit (MU) settings is important for dosimetric applications. Dose linearity, beam flatness, and beam energies were studied at low MU settings with various dose rates for different types of linear accelerators. It is observed that for the scattering foil units, the dose/MU is a sm...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597328

    authors: Das IJ,Harrington JC,Akber SF,Tomer AF,Murray JC,Cheng CW

    更新日期:1994-06-01 00:00:00

  • A dosimetry review system for cooperative group research.

    abstract::The validity of conclusions drawn from multi-institutional radiotherapy studies is dependent upon the degree to which participating hospitals adhere to study requirements. A major effort undertaken by the Quality Assurance Review Center (QARC) assesses whether or not patient data which are deemed evaluable actually co...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595221

    authors: Reinstein LE,McShan D,Glicksman AS

    更新日期:1982-03-01 00:00:00

  • Multileaf collimator performance monitoring and improvement using semiautomated quality control testing and statistical process control.

    abstract:PURPOSE:High-quality radiation therapy using highly conformal dose distributions and image-guided techniques requires optimum machine delivery performance. In this work, a monitoring system for multileaf collimator (MLC) performance, integrating semiautomated MLC quality control (QC) tests and statistical process contr...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4901520

    authors: Létourneau D,Wang A,Amin MN,Pearce J,McNiven A,Keller H,Norrlinger B,Jaffray DA

    更新日期:2014-12-01 00:00:00

  • Principles in positioning cross-projecting lasers.

    abstract::With the increased sophistication of lasers used for patient positioning in radiotherapy comes increased possibilities for mistakes in installing the lasers, which can result in serious patient positioning errors. Two principles must be followed when mounting cross-projecting lasers: (1) the horizontal line must be on...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594960

    authors: Thomadsen BR

    更新日期:1981-05-01 00:00:00

  • On using an adaptive neural network to predict lung tumor motion during respiration for radiotherapy applications.

    abstract::In this study we address the problem of predicting the position of a moving lung tumor during respiration on the basis of external breathing signals--a technique used for beam gating, tracking, and other dynamic motion management techniques in radiation therapy. We demonstrate the use of neural network filters to corr...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2134958

    authors: Isaksson M,Jalden J,Murphy MJ

    更新日期:2005-12-01 00:00:00

  • Performance of a high-sensitivity dedicated cardiac SPECT scanner for striatal uptake quantification in the brain based on analysis of projection data.

    abstract:PURPOSE:The authors have previously reported the advantages of high-sensitivity single-photon emission computed tomography (SPECT) systems for imaging structures located deep inside the brain. DaTscan (Isoflupane I-123) is a dopamine transporter (DaT) imaging agent that has shown potential for early detection of Parkin...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4794488

    authors: Park MA,Moore SC,Müller SP,McQuaid SJ,Kijewski MF

    更新日期:2013-04-01 00:00:00

  • Combining tissue-phantom ratios to provide a beam-quality specifier for flattening filter free photon beams.

    abstract:PURPOSE:There are currently several commercially available radiotherapy treatment units without a flattening filter in the beam line. Unflattened photon beams have an energy and lateral fluence distribution that is different from conventional beams and, thus, their attenuation properties differ. As a consequence, for f...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4898325

    authors: Dalaryd M,Knöös T,Ceberg C

    更新日期:2014-11-01 00:00:00

  • 3D MTF estimation using sphere phantoms for cone-beam computed tomography systems.

    abstract:PURPOSE:For cone-beam computed tomography (CBCT) systems, we propose a sphere phantom based method to estimate the full three-dimensional (3D) modulation transfer function (MTF). METHODS:The FDK reconstruction of CBCT system in a local region was modeled by a triple convolution operator. Afterward, we calculated the d...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14147

    authors: Lee C,Song HD,Baek J

    更新日期:2020-07-01 00:00:00

  • Quantification with a dedicated breast PET/CT scanner.

    abstract:PURPOSE:Dedicated breast PET/CT is expected to have utility in local staging, surgical planning, monitoring of therapy response, and detection of residual disease for breast cancer. Quantitative metrics will be integral to several such applications. The authors present a validation of fully 3D data correction schemes f...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3703593

    authors: Bowen SL,Ferrero A,Badawi RD

    更新日期:2012-05-01 00:00:00

  • Projection-domain scatter correction for cone beam computed tomography using a residual convolutional neural network.

    abstract:PURPOSE:Scatter is a major factor degrading the image quality of cone beam computed tomography (CBCT). Conventional scatter correction strategies require handcrafted analytical models with ad hoc assumptions, which often leads to less accurate scatter removal. This study aims to develop an effective scatter correction ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13583

    authors: Nomura Y,Xu Q,Shirato H,Shimizu S,Xing L

    更新日期:2019-07-01 00:00:00

  • Patient motion effects on the quantification of regional myocardial blood flow with dynamic PET imaging.

    abstract:PURPOSE:Patient motion is a common problem during dynamic positron emission tomography (PET) scans for quantification of myocardial blood flow (MBF). The purpose of this study was to quantify the prevalence of body motion in a clinical setting and evaluate with realistic phantoms the effects of motion on blood flow qua...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4943565

    authors: Hunter CR,Klein R,Beanlands RS,deKemp RA

    更新日期:2016-04-01 00:00:00

  • SU-E-T-264: New Concrete Designed and Evaluation for Megavoltage X Radiotherapy Facilities (CONTEK-RFH2).

    abstract:PURPOSE:The most common material for shielding is concrete, which can be made using various materials of different densities as aggregates. New techniques in radiotherapy, as IMRT and VMAT, require more monitor units and it is important to develop specifically designed shielding materials. METHODS:Arraela S.L. has dev...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735331

    authors: Mera M,Pereira L,Mera M,Pereira L,Meilán E,Moral FD,Teijeiro A,Salgado M,Andrade B,Gomez F,Fuentes-Vázquez V,Caruncho J,Medina A

    更新日期:2012-06-01 00:00:00

  • TU-E-213AB-01: JMPSLC Has Morphed into Medical Physics Licensure and Regulatory Recognition Subcommittee.

    abstract::Based on direction from AAM Board of Directors, JMPLSC has redefined its scope and name. On November 4, 2011 the subcommittee renamed itself the Medical Physics Licensure and Regulatory Recognition Subcommittee. Its newly defined charge is to promote the protection of the public through the recognition of the professi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735947

    authors: Pizzutiello R

    更新日期:2012-06-01 00:00:00

  • High resolution stationary digital breast tomosynthesis using distributed carbon nanotube x-ray source array.

    abstract:PURPOSE:The purpose of this study is to investigate the feasibility of increasing the system spatial resolution and scanning speed of Hologic Selenia Dimensions digital breast tomosynthesis (DBT) scanner by replacing the rotating mammography x-ray tube with a specially designed carbon nanotube (CNT) x-ray source array,...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3694667

    authors: Qian X,Tucker A,Gidcumb E,Shan J,Yang G,Calderon-Colon X,Sultana S,Lu J,Zhou O,Spronk D,Sprenger F,Zhang Y,Kennedy D,Farbizio T,Jing Z

    更新日期:2012-04-01 00:00:00

  • A novel PET tumor delineation method based on adaptive region-growing and dual-front active contours.

    abstract::To more accurately and precisely delineate a tumor in a 3D PET image, we proposed a novel, semi-automatic, two-stage method by utilizing an adaptive region-growing algorithm and a dual-front active contour model. First, a rough region of interest (ROI) is manually drawn by a radiation oncologist that encloses a tumor....

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2956713

    authors: Li H,Thorstad WL,Biehl KJ,Laforest R,Su Y,Shoghi KI,Donnelly ED,Low DA,Lu W

    更新日期:2008-08-01 00:00:00

  • Feature selection using factor analysis for Alzheimer's diagnosis using 18F-FDG PET images.

    abstract:PURPOSE:This article presents a computer-aided diagnosis technique for improving the accuracy of the early diagnosis of Alzheimer's disease (AD). Two hundred and ten 18F-FDG PET images from the ADNI initiative [52 normal controls (NC), 114 mild cognitive impairment (MCI), and 53 AD subjects] are studied. METHODS:The p...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3488894

    authors: Salas-Gonzalez D,Górriz JM,Ramírez J,Illán IA,López M,Segovia F,Chaves R,Padilla P,Puntonet CG