A restricted angular scattering model for electron penetration in dense media.

Abstract:

:A restricted angular scattering model for electron penetration in dense media is presented. In the model, the Fermi-Eyges transport equation is modified through the addition of an extra term which may be interpreted as representing an apparent force opposing the scattering of electrons into wider angles. The introduction of this extra term allows the modeling of the measured saturation in the mean square angular spread of electrons with depth. The restricted scattering model retains the Gaussian features of the Fermi-Eyges model and, therefore, may be readily incorporated into existing dose computation algorithms. Good agreement is obtained with measured angular electron distribution data for a point monodirectional beam over a wide range of incident electron energies (5-20 MeV) and scattering media (atomic numbers of 6 to 82). Also, a comparison of the restricted scattering model predictions with measurements of the lateral pencil beam spread shows an improvement over the predictions of Fermi-Eyges model close to the end of the electron range. Broad beam profiles were generated using both the Fermi-Eyges and restricted scattering models. A comparison of predicted and measured beam profiles shows that the restricted scattering model is a significant improvement over the Fermi-Eyges model for the prediction of beam penumbra shape in homogeneous media.

journal_name

Med Phys

journal_title

Medical physics

authors

McLellan J,Sandison GA,Papiez L,Huda W

doi

10.1118/1.596747

subject

Has Abstract

pub_date

1991-01-01 00:00:00

pages

1-6

issue

1

eissn

0094-2405

issn

2473-4209

journal_volume

18

pub_type

杂志文章
  • Effect of surrounding vasculature on intravoxel BOLD signal.

    abstract:PURPOSE:The nonlocal influence from distant magnetization will affect the magnetic field at a voxel in question. Existing reports on BOLD simulation only consider vasculature inside a single voxel, thus omitting the contribution from the surrounding regions. In this article, the authors study the effect of the surround...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3366251

    authors: Chen Z,Caprihan A,Calhoun V

    更新日期:2010-04-01 00:00:00

  • SAPHIRE (scintillator avalanche photoconductor with high resolution emitter readout) for low dose x-ray imaging: spatial resolution.

    abstract::An indirect flat panel imager (FPI) with programmable avalanche gain and field emitter array (FEA) readout is being investigated for low-dose and high resolution x-ray imaging. It is made by optically coupling a structured x-ray scintillator, e.g., thallium (Tl) doped cesium iodide (CsI), to an amorphous selenium (a-S...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2937652

    authors: Li D,Zhao W

    更新日期:2008-07-01 00:00:00

  • Updated breast CT dose coefficients (DgNCT ) using patient-derived breast shapes and heterogeneous fibroglandular distributions.

    abstract:PURPOSE:The purpose of this work was to generate uncompressed heterogeneous breast phantom models using size-dependent fibroglandular distributions derived from a large cohort of breast CT (bCT) datasets, and to compare differences in normalized glandular dose coefficients for bCT "DgNCT " when the realistic heterogene...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13391

    authors: Hernandez AM,Becker AE,Boone JM

    更新日期:2019-03-01 00:00:00

  • Biomechanical modeling constrained surface-based image registration for prostate MR guided TRUS biopsy.

    abstract:PURPOSE:Adding magnetic resonance (MR)-derived information to standard transrectal ultrasound (TRUS) images for guiding prostate biopsy is of substantial clinical interest. A tumor visible on MR images can be projected on ultrasound (US) by using MR-US registration. A common approach is to use surface-based registratio...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4917481

    authors: van de Ven WJ,Hu Y,Barentsz JO,Karssemeijer N,Barratt D,Huisman HJ

    更新日期:2015-05-01 00:00:00

  • Device-dependent activity estimation and decay correction of radionuclide mixtures with application to Tc-94m PET studies.

    abstract::Multi-instrument activity estimation and decay correction techniques were developed for radionuclide mixtures, motivated by the desire for accurate quantitation of Tc-94m positron emission tomography (PET) studies. Tc-94m and byproduct Tc isotopes were produced by proton irradiation of enriched Mo-94 and natural Mo ta...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1333411

    authors: Smith MF,Daube-Witherspoon ME,Plascjak PS,Szajek LP,Carson RE,Everett JR,Green SL,Territo PR,Balaban RS,Bacharach SL,Eckelman WC

    更新日期:2001-01-01 00:00:00

  • Attenuation, scattering, and absorption of ultrasound in the skull bone.

    abstract:PURPOSE:Measured values of ultrasound attenuation in bone represent a combination of different loss mechanisms. As a wave is transmitted from a fluid into bone, reflections occur at the interface. In the bone, mode conversion occurs between longitudinal and shear modes and the mechanical wave is scattered by its comple...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3668316

    authors: Pinton G,Aubry JF,Bossy E,Muller M,Pernot M,Tanter M

    更新日期:2012-01-01 00:00:00

  • Dose enhancement in radiotherapy of small lung tumors using inline magnetic fields: A Monte Carlo based planning study.

    abstract:PURPOSE:To report on significant dose enhancement effects caused by magnetic fields aligned parallel to 6 MV photon beam radiotherapy of small lung tumors. Findings are applicable to future inline MRI-guided radiotherapy systems. METHODS:A total of eight clinical lung tumor cases were recalculated using Monte Carlo me...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4938580

    authors: Oborn BM,Ge Y,Hardcastle N,Metcalfe PE,Keall PJ

    更新日期:2016-01-01 00:00:00

  • Clinical reference dosimetry: comparison between AAPM TG-21 and TG-51 protocols.

    abstract::We compare the results of absorbed dose determined at reference conditions according to the AAPM TG-21 dose calibration protocol and the new AAPM TG-51 protocol. The AAPM TG-21 protocol for absorbed dose calibration is based on ionization chambers having exposure calibration factors for 60Co gamma rays, N(x). The new ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598999

    authors: Ding GX,Cygler JE,Kwok CB

    更新日期:2000-06-01 00:00:00

  • Poster - Thur Eve - 31: RapidArc total body photon irradiation: A feasibility study.

    abstract::Total body photon irradiation (TBI) may be delivered with a number of standard techniques, typically using extended SSD geometries to obtain large field sizes. Since 1982 we have treated over 620 patients (adult and pediatric) mostly in the floor-located prone/supine treatment position with AP/PA beams using a column ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4740139

    authors: Evans M,Ruo R,Seuntjens J,Freeman CR,Parker W

    更新日期:2012-07-01 00:00:00

  • Reproducibility of the lung anatomy under active breathing coordinator control: Dosimetric consequences for scanned proton treatments.

    abstract:PURPOSE:The treatment of moving targets with scanned proton beams is challenging. For motion mitigation, an Active Breathing Coordinator (ABC) can be used to assist breath-holding. The delivery of pencil beam scanning fields often exceeds feasible breath-hold durations, requiring high breath-hold reproducibility. We ev...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13195

    authors: den Otter LA,Kaza E,Kierkels RGJ,Meijers A,Ubbels FJF,Leach MO,Collins DJ,Langendijk JA,Knopf AC

    更新日期:2018-12-01 00:00:00

  • Comparison of x ray computed tomography number to proton relative linear stopping power conversion functions using a standard phantom.

    abstract:PURPOSE:Adequate evaluation of the results from multi-institutional trials involving light ion beam treatments requires consideration of the planning margins applied to both targets and organs at risk. A major uncertainty that affects the size of these margins is the conversion of x ray computed tomography numbers (XCT...

    journal_title:Medical physics

    pub_type: 杂志文章,多中心研究

    doi:10.1118/1.4870956

    authors: Moyers MF

    更新日期:2014-06-01 00:00:00

  • SU-D-218-05: Material Quantification in Spectral X-Ray Imaging: Optimization and Validation.

    abstract:PURPOSE:To develop and validate a multivariate statistical method to optimize scanning parameters for material quantification in spectral x-rayimaging. METHODS:An optimization metric was constructed by extensively sampling the thickness space for the expected number of counts for m (two or three) materials. This resul...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734708

    authors: Nik SJ,Thing RS,Watts R,Meyer J

    更新日期:2012-06-01 00:00:00

  • Nonlocal atlas-guided multi-channel forest learning for human brain labeling.

    abstract:PURPOSE:It is important for many quantitative brain studies to label meaningful anatomical regions in MR brain images. However, due to high complexity of brain structures and ambiguous boundaries between different anatomical regions, the anatomical labeling of MR brain images is still quite a challenging task. In many ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4940399

    authors: Ma G,Gao Y,Wu G,Wu L,Shen D

    更新日期:2016-02-01 00:00:00

  • SU-E-T-610: Impact of Variable Beam Spot Size on Treatment Time in Particle Therapy.

    abstract:PURPOSE:The dosimetric advantage of particle therapy comes with a much higher infrastructure investment and operation costs. Increasing patient throughput is a key factor to manage operation costs. We investigate the impact of variable beam spot sizes on treatment time and discuss the tradeoffs involved. METHODS:The f...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735699

    authors: Riofrio D,Sellner S,Cabal G,Keyes R,Holzscheiter M,Jaekel O,Luan S

    更新日期:2012-06-01 00:00:00

  • SU-E-T-576: Investigation of Combining Modulated Electron Beams with Intensity Modulated Photons for Radiation Therapy of Breast Cases.

    abstract:PURPOSE:Modulated electron radiation therapy (MERT) can offer significant advantages for breast treatments over conventional radiotherapy in terms of sparing distal critical structures. While intensity modulated radiation therapy (IMRT) has the advantage of achieving better dose homogeneity inside the target combining ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735665

    authors: Eldib A,Li J,Jin L,Ma C

    更新日期:2012-06-01 00:00:00

  • Technical Note: Experimental determination of the effective point of measurement of two cylindrical ionization chambers in a clinical proton beam.

    abstract:PURPOSE:IAEA TRS-398 notes that cylindrical ionization chambers are preferred for reference proton dosimetry. If a cylindrical ionization chamber is used in a phantom to measure the dose as a function of depth, the effective point of measurement (EPOM) must be taken into account. IAEA TRS-398 recommends a displacement ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4921617

    authors: Sugama Y,Nishio T,Onishi H

    更新日期:2015-07-01 00:00:00

  • Motion estimation for cardiac functional analysis using two x-ray computed tomography scans.

    abstract:PURPOSE:This work concerns computed tomography (CT)-based cardiac functional analysis (CFA) with a reduced radiation dose. As CT-CFA requires images over the entire heartbeat, the scans are often performed at 10-20% of the tube current settings that are typically used for coronary CT angiography. A large image noise th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12425

    authors: Fung GSK,Ciuffo L,Ashikaga H,Taguchi K

    更新日期:2017-09-01 00:00:00

  • Validation for 2D/3D registration. I: A new gold standard data set.

    abstract:PURPOSE:In this article, the authors propose a new gold standard data set for the validation of two-dimensional/three-dimensional (2D/3D) and 3D/3D image registration algorithms. METHODS:A gold standard data set was produced using a fresh cadaver pig head with attached fiducial markers. The authors used several imagin...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3553402

    authors: Pawiro SA,Markelj P,Pernus F,Gendrin C,Figl M,Weber C,Kainberger F,Nöbauer-Huhmann I,Bergmeister H,Stock M,Georg D,Bergmann H,Birkfellner W

    更新日期:2011-03-01 00:00:00

  • Repeatability of SUV measurements in serial PET.

    abstract:PURPOSE:The standardized uptake value (SUV) is a quantitative measure of FDG tumor uptake frequently used as a tool to monitor therapeutic response. This study aims to (i) assess the reproducibility and uncertainty of SUV max and SUV mean, due to purely statistical, i.e., nonbiological, effects and (ii) to establish th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3578604

    authors: Schwartz J,Humm JL,Gonen M,Kalaigian H,Schoder H,Larson SM,Nehmeh SA

    更新日期:2011-05-01 00:00:00

  • A phantom for visualization of three-dimensional drug release by ultrasound-induced mild hyperthermia.

    abstract:PURPOSE:Ultrasound-induced mild hyperthermia has advantages for noninvasive, localized and controlled drug delivery. In this study, a tissue-mimicking agarose-based phantom with a thermally sensitive indicator was developed for studying the spatial drug delivery profile using ultrasound-induced mild hyperthermia. METH...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4813299

    authors: Lai CY,Kruse D,Seo JW,Kheirolomoom A,Ferrara KW

    更新日期:2013-08-01 00:00:00

  • Improved gradient-echo 3D magnetic resonance imaging using compressed sensing and Toeplitz encoding with phase-scrambled RF excitation.

    abstract:PURPOSE:To develop a novel three-dimensional (3D) hybrid-encoding framework using compressed sensing (CS) and Toeplitz encoding with variable phase-scrambled radio-frequency (RF) excitation, which has the following advantages: low power deposition of RF pulses, reduction of the signal dynamic range, no additional hardw...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13987

    authors: Wang H,Liang D,Su S,King KF,Chang Y,Liu X,Zheng H,Ying L

    更新日期:2020-04-01 00:00:00

  • Determination of electron energy, spectral width, and beam divergence at the exit window for clinical megavoltage x-ray beams.

    abstract::Monte Carlo simulations of x-ray beams typically take parameters of the electron beam in the accelerating waveguide to be free parameters. In this paper, a methodology is proposed and implemented to determine the energy, spectral width, and beam divergence of the electron source. All treatment head components were rem...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3070547

    authors: Sawkey DL,Faddegon BA

    更新日期:2009-03-01 00:00:00

  • Fast time-of-flight camera based surface registration for radiotherapy patient positioning.

    abstract:PURPOSE:This work introduces a rigid registration framework for patient positioning in radiotherapy, based on real-time surface acquisition by a time-of-flight (ToF) camera. Dynamic properties of the system are also investigated for future gating/tracking strategies. METHODS:A novel preregistration algorithm, based on...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3664006

    authors: Placht S,Stancanello J,Schaller C,Balda M,Angelopoulou E

    更新日期:2012-01-01 00:00:00

  • Evaluating IMRT and VMAT dose accuracy: practical examples of failure to detect systematic errors when applying a commonly used metric and action levels.

    abstract:PURPOSE:This study (1) examines a variety of real-world cases where systematic errors were not detected by widely accepted methods for IMRT/VMAT dosimetric accuracy evaluation, and (2) drills-down to identify failure modes and their corresponding means for detection, diagnosis, and mitigation. The primary goal of detai...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4826166

    authors: Nelms BE,Chan MF,Jarry G,Lemire M,Lowden J,Hampton C,Feygelman V

    更新日期:2013-11-01 00:00:00

  • Computerized analysis of radiographic bone patterns: effect of imaging conditions on performance.

    abstract::We are developing computerized methods for characterizing the bone texture pattern from digitized skeletal radiographs. For this method to be useful clinically, it must be able to distinguish between weak and strong bone under the range of exposure conditions potentially encountered in the clinical setting. In this st...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598858

    authors: Chinander MR,Giger ML,Martell JM,Favus MJ

    更新日期:2000-01-01 00:00:00

  • Performance characteristics of transmission imaging using a uniform sheet source with parallel-hole collimation.

    abstract::Transmission imaging is receiving increasing attention in SPECT due to the need to compensate for nonuniform attenuation in cardiac-chest SPECT. The quality of a transmission image has an important effect on the measured attenuation distribution. To improve image quality, knowledge of the performance characteristics o...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596752

    authors: Cao Z,Tsui BM

    更新日期:1992-09-01 00:00:00

  • Transverse axial film tomography with a therapy simulator.

    abstract::A tomographic attachment was designed and developed that attaches to our existing simulator. The film tomograms obtained with the aid of this device exhibit very low geometrical distortion and good contrast and resolution for the objects used in this investigation. In addition, our results to date show that adjacent a...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594662

    authors: Kessaris ND,Harisiadis L

    更新日期:1980-03-01 00:00:00

  • Nitroxide conjugate of a thermally responsive elastin-like polypeptide for noninvasive thermometry.

    abstract::Hyperthermia, as an adjuvant with radiation and chemotherapy, has shown promise in the treatment of cancer. The relevant biological effects of a hyperthermia treatment are both time and temperature-dependent, creating a need for accurate thermometry. We present a novel noninvasive thermometry modality that combines a ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1782677

    authors: Dreher MR,Elas M,Ichikawa K,Barth ED,Chilkoti A,Rosen GM,Halpern HJ,Dewhirst M

    更新日期:2004-10-01 00:00:00

  • SU-E-T-573: Quality and Deliverability of Intensity Modulated Neutron Radiotherapy (IMNRT) Plans.

    abstract:PURPOSE:Intensity Modulated Neutron Radiotherapy (IMNRT) has been commissioned for clinical use. The number of allowable segments in IMNRT plans is limited by MLC speed. Quality and deliverability of static IMNRT treatment plans using the TG-119 test suite were evaluated to establish guidelines for the number of segmen...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735662

    authors: Spink R,Burmeister J,Bossenberger T,Snyder M

    更新日期:2012-06-01 00:00:00

  • Accuracy of cranial coplanar beam therapy using an oblique, stereoscopic x-ray image guidance system.

    abstract::A system for measuring two-dimensional (2D) dose distributions in orthogonal anatomical planes in the cranium was developed and used to evaluate the accuracy of coplanar conformal therapy using ExacTrac image guidance. Dose distributions were measured in the axial, sagittal, and coronal planes using a CIRS (Computeriz...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2955751

    authors: Vinci JP,Hogstrom KR,Neck DW

    更新日期:2008-08-01 00:00:00