Performance characteristics of transmission imaging using a uniform sheet source with parallel-hole collimation.

Abstract:

:Transmission imaging is receiving increasing attention in SPECT due to the need to compensate for nonuniform attenuation in cardiac-chest SPECT. The quality of a transmission image has an important effect on the measured attenuation distribution. To improve image quality, knowledge of the performance characteristics of a transmission imaging system is essential. The characteristics, spatial resolution, detection efficiency, photon flux, and exposure to the object, of a transmission imaging system consisting of a gamma camera and a uniform sheet source have been studied. The results demonstrate that spatial resolution of a transmission imaging system can be improved by use of a high-resolution source collimator at the price of a moderate decrease in detection efficiency, in comparison to the uncollimated case. Also, the source collimator significantly reduces the photon flux and exposure to the object. This investigation suggests that a high-resolution collimator be used with an intense sheet source to improve spatial resolution and reduce statistical noise with low exposure to the patient. This research further suggests that the amount of source activity is determined by the requirement of image quality, detection geometry, and allowed absorbed dose to the patient.

journal_name

Med Phys

journal_title

Medical physics

authors

Cao Z,Tsui BM

doi

10.1118/1.596752

subject

Has Abstract

pub_date

1992-09-01 00:00:00

pages

1205-12

issue

5

eissn

0094-2405

issn

2473-4209

journal_volume

19

pub_type

杂志文章
  • A novel respiratory tracking system for smart-gated PET acquisition.

    abstract:PURPOSE:In this study, the authors validated a novel respiratory tracking device, the multidimensional respiratory tracking (MDRT) system, that was designed to assist in correcting for respiratory motion in PET/CT images. The authors also investigated a novel PET acquisition technique, smart gating (SG), that enables t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3523100

    authors: Nehmeh SA,Haj-Ali AA,Qing C,Stearns C,Kalaigian H,Kohlmyer S,Schoder H,Ho AY,Larson SM,Humm JL

    更新日期:2011-01-01 00:00:00

  • A fast 4D IMRT/VMAT planning method based on segment aperture morphing.

    abstract:PURPOSE:Four-dimensional volumetric modulated arc therapy (4D VMAT) and four-dimensional intensity-modulated radiotherapy (4D IMRT) are developing radiation therapy treatment strategies designed to maximize dose conformality, minimize normal tissue dose, and deliver the treatment as efficiently as possible. The patient...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12778

    authors: Klawikowski S,Tai A,Ates O,Ahunbay E,Li XA

    更新日期:2018-04-01 00:00:00

  • Noise, resolution, and sensitivity considerations in the design of a single-slice emission-transmission computed tomographic system.

    abstract::A prototype Emission-Transmission Computed Tomography (ETCT) system is being developed that will acquire single-slice x-ray transmission CT images simultaneously with single photon emission computed tomography (SPECT) images. This system will permit the correlation of anatomical information from x-ray CT with function...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596643

    authors: Liew SC,Hasegawa BH

    更新日期:1991-09-01 00:00:00

  • Use of a constrained hierarchical optimization dataset enhances knowledge-based planning as a quality assurance tool for prostate bed irradiation.

    abstract:PURPOSE:To investigate whether building a knowledge-based planning (KBP) model with prostate bed plans constructed from constrained hierarchical optimization (CHO) would result in more efficient model construction with more consistent output than a model built using plans from a traditional, trial-and-error-based optim...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13163

    authors: Lin YH,Hong LX,Hunt MA,Berry SL

    更新日期:2018-10-01 00:00:00

  • Correcting kernel tilting and hardening in convolution/superposition dose calculations for clinical divergent and polychromatic photon beams.

    abstract::To account for clinical divergent and polychromatic photon beams, we have developed kernel tilting and kernel hardening correction methods for convolution dose calculation algorithms. The new correction methods were validated by Monte Carlo simulation. The accuracy and computation time of the our kernel tilting and ke...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597960

    authors: Liu HH,Mackie TR,McCullough EC

    更新日期:1997-11-01 00:00:00

  • Experimental evaluation of the dosimetric impact of intrafraction prostate rotation using film measurement with a 6DoF robotic arm.

    abstract:PURPOSE:Tumor motion during radiotherapy can cause a reduction in target dose coverage and an increase in healthy tissue exposure. Tumor motion is not strictly translational and often exhibits complex six degree-of-freedom (6DoF) translational and rotational motion. Although the dosimetric impact of prostate tumor tran...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14502

    authors: Shi K,Dipuglia A,Booth J,Alnaghy S,Kyme A,Keall P,Nguyen DT

    更新日期:2020-12-01 00:00:00

  • Polarized x-ray excitation for scatter reduction in x-ray fluorescence computed tomography.

    abstract:PURPOSE:X-ray fluorescence computer tomography (XFCT) is a new molecular imaging modality which uses x-ray excitation to stimulate the emission of fluorescent photons in high atomic number contrast agents. Scatter contamination is one of the main challenges in XFCT imaging which limits the molecular sensitivity. When p...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12997

    authors: Vernekohl D,Tzoumas S,Zhao W,Xing L

    更新日期:2018-05-25 00:00:00

  • Beam modeling and verification of a photon beam multisource model.

    abstract::Dose calculations for treatment planning of photon beam radiotherapy require a model of the beam to drive the dose calculation models. The beam shaping process involves scattering and filtering that yield radiation components which vary with collimator settings. The necessity to model these components has motivated th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1898485

    authors: Ahnesjö A,Weber L,Murman A,Saxner M,Thorslund I,Traneus E

    更新日期:2005-06-01 00:00:00

  • The use of a priori information in the detection of mammographic microcalcifications to improve their classification.

    abstract::In this work, we present a calcification-detection scheme that automatically localizes calcifications in a previously detected cluster in order to generate the input for a cluster-classification scheme developed in the past. The calcification-detection scheme makes use of three pieces of a priori information: the loca...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1559884

    authors: Salfity MF,Nishikawa RM,Jiang Y,Papaioannou J

    更新日期:2003-05-01 00:00:00

  • Investigating energy deposition in glandular tissues for mammography using multiscale Monte Carlo simulations.

    abstract:PURPOSE:To investigate energy deposition in glandular tissues of the breast on macro- and microscopic length scales in the context of mammography. METHODS:Multiscale mammography models of breasts are developed, which include segmented, voxelized macroscopic tissue structure as well as nine regions of interest (ROIs) e...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13372

    authors: Oliver PAK,Thomson RM

    更新日期:2019-03-01 00:00:00

  • Computerized detection of masses in digital mammograms: analysis of bilateral subtraction images.

    abstract::A computerized scheme is being developed for the detection of masses in digital mammograms. Based on the deviation from the normal architectural symmetry of the right and left breasts, a bilateral subtraction technique is used to enhance the conspicuity of possible masses. The scheme employs two pairs of conventional ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596610

    authors: Yin FF,Giger ML,Doi K,Metz CE,Vyborny CJ,Schmidt RA

    更新日期:1991-09-01 00:00:00

  • A simple model for examining issues in radiotherapy optimization.

    abstract::Convolution/superposition software has been used to produce a library of photon pencil beam dose matrices. This library of pencil beams is designed to serve as a tool for both education and investigation in the field of radiotherapy optimization. The elegance of this pencil beam model stems from its cylindrical symmet...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598615

    authors: Shepard DM,Olivera G,Angelos L,Sauer O,Reckwerdt P,Mackie TR

    更新日期:1999-07-01 00:00:00

  • Technical Note: Correction for the effect of breathing variations in CT pulmonary ventilation imaging.

    abstract:PURPOSE:The accuracy and precision of computed tomography (CT) pulmonary ventilation imaging with conventional CT scanners are limited by breathing variations. We propose a method to correct for the effect of breathing variations in CT ventilation imaging based on external respiratory signals acquired throughout a scan...

    journal_title:Medical physics

    pub_type: 临床试验,杂志文章

    doi:10.1002/mp.12634

    authors: Yamamoto T,Kabus S

    更新日期:2018-01-01 00:00:00

  • The application of sparse arrays in high frequency transcranial focused ultrasound therapy: a simulation study.

    abstract:PURPOSE:Transcranial focused ultrasound is an emerging therapeutic modality that can be used to perform noninvasive neurosurgical procedures. The current clinical transcranial phased array operates at 650 kHz, however the development of a higher frequency array would enable more precision, while reducing the risk of st...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4829510

    authors: Pajek D,Hynynen K

    更新日期:2013-12-01 00:00:00

  • Designing an optical distance indicator for a radiation therapy accelerator.

    abstract::The computational aspects of the design of an optical distance indicator (ODI) for use with a radiation therapy accelerator are discussed. The specifics of the optical and mechanical design of an ODI for use with a superconducting cyclotron used for fast neutron therapy are presented. ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598510

    authors: Maughan RL

    更新日期:1999-02-01 00:00:00

  • A Monte Carlo comparison of the response of the PTW-diamond and the TL-diamond detectors in megavoltage photon beams.

    abstract::A detailed Monte Carlo study of the PTW-diamond solid state detector response in megavoltage photon beams (60Co gamma rays to 25 MV x rays) has been performed with the EGS4 Monte Carlo Code. The sensitive volume of the diamond detector is a disk of diameter 4.4 mm and thickness 0.40 mm. The phantom material was water ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598771

    authors: Mobit PN,Sandison GA

    更新日期:1999-11-01 00:00:00

  • A compensative model for the angle-dependence of motion estimates in noninvasive vascular elastography.

    abstract:PURPOSE:Atherosclerosis of peripheral cerebral arteries can lead to stroke either by stenosis formation or plaque rupture. This pathology is initiated by the alteration of arterial wall mechanical properties shown to be assessable by ultrasound elastography. Recently, noninvasive vascular elastography (NIVE) was introd...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3539701

    authors: Mercure E,Deprez JF,Fromageau J,Basset O,Soulez G,Cloutier G,Maurice RL

    更新日期:2011-02-01 00:00:00

  • Multileaf collimator performance monitoring and improvement using semiautomated quality control testing and statistical process control.

    abstract:PURPOSE:High-quality radiation therapy using highly conformal dose distributions and image-guided techniques requires optimum machine delivery performance. In this work, a monitoring system for multileaf collimator (MLC) performance, integrating semiautomated MLC quality control (QC) tests and statistical process contr...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4901520

    authors: Létourneau D,Wang A,Amin MN,Pearce J,McNiven A,Keller H,Norrlinger B,Jaffray DA

    更新日期:2014-12-01 00:00:00

  • Calculation of x-ray spectra emerging from an x-ray tube. Part II. X-ray production and filtration in x-ray targets.

    abstract::A new approach to the calculation of the x-ray spectrum emerging from an x-ray tube is proposed. Theoretical results for the bremsstrahlung cross section appearing in the literature are summarized. Four different treatments of electron penetration, based on the work presented in Part I, are then used to generate brems...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2734726

    authors: Poludniowski GG

    更新日期:2007-06-01 00:00:00

  • An investigation of a new amorphous silicon electronic portal imaging device for transit dosimetry.

    abstract::The relationship between the pixel value and exit dose was investigated for a new commercially available amorphous silicon electronic portal imaging device. The pixel to dose mapping function was established to be linear for detector distances between 116.5 cm to 150 cm from the source, radiation field sizes from 5 x ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1508108

    authors: Grein EE,Lee R,Luchka K

    更新日期:2002-10-01 00:00:00

  • Evaluation of volumetric modulated arc therapy for cranial radiosurgery using multiple noncoplanar arcs.

    abstract:PURPOSE:To evaluate a commercial volumetric modulated arc therapy (VMAT), using multiple noncoplanar arcs, for linac-based cranial radiosurgery, as well as evaluate the combined accuracy of the VMAT dose calculations and delivery. METHODS:Twelve patients with cranial lesions of variable size (0.1-29 cc) and two multip...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3641874

    authors: Audet C,Poffenbarger BA,Chang P,Jackson PS,Lundahl RE,Ryu SI,Ray GR

    更新日期:2011-11-01 00:00:00

  • Large field of view distortion assessment in a low-field MR-linac.

    abstract:PURPOSE:MR-guided radiation therapy (RT) offers unparalleled soft tissue contrast for localization and target tracking. However, MRI distortions may be detrimental to high precision RT. This work characterizes the gradient nonlinearity (GNL) and total distortions over the first year of clinical operation of a 0.35T MR-...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13467

    authors: Nejad-Davarani SP,Kim JP,Du D,Glide-Hurst C

    更新日期:2019-05-01 00:00:00

  • Accuracy of registration algorithms in subtraction CT of the lungs: A digital phantom study.

    abstract:PURPOSE:The purpose of this study was to assess, using an anthropomorphic digital phantom, the accuracy of algorithms in registering precontrast and contrast-enhanced computed tomography (CT) chest images for generation of iodine maps of the pulmonary parenchyma via temporal subtraction. MATERIALS AND METHODS:The XCAT...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13496

    authors: Grob D,Oostveen L,Rühaak J,Heldmann S,Mohr B,Michielsen K,Dorn S,Prokop M,Kachelrieβ M,Brink M,Sechopoulos I

    更新日期:2019-05-01 00:00:00

  • Broad line quantitative chemical shift spectroscopy.

    abstract::Proton NMR spectroscopy was applied to quantitate the measurement of total body water/fat distributions in vivo. A special MR protocol was developed to excite a thick slab of tissue and display the magnitude NMR spectrum of the collected response signal. Very short echo time TE (8 ms) and long repetition time TR (4000...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596935

    authors: Sobol WT,Elster AD,Hinson WH,Chwals WJ

    更新日期:1992-01-01 00:00:00

  • Penetration quality measurement for standardization of radiographic image quality.

    abstract::Interchange or transfer of radiographic techniques through measurement of penetration quality is discussed. The usefulness of this achievement is verified using an aluminum step wedge. Also, the procedure described provides a method for performance evaluation of kVp compensation on diagnostic x-ray installations. ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594156

    authors: Lin PJ

    更新日期:1975-01-01 00:00:00

  • 115In as a probe for the characterization of therapy bremsstrahlung beams and the detection of photoneutrons.

    abstract::Variation of the photoactivation rate across radiation fields of three different bremsstrahlung beams of two medical accelerators has been measured, making use of the photonuclear reactions in natural indium probes: 115In(y,y')115mIn and 115In(y,n)114mIn. The third nuclear reaction, 115In(n,y)116mIn, was used to detec...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598558

    authors: Krmar M,Slivka J,Bikit I,Conkić L,Rudić A

    更新日期:1999-04-01 00:00:00

  • Fluid-filled dynamic bowtie filter: Description and comparison with other modulators.

    abstract:PURPOSE:A dynamic bowtie filter can modulate flux along both fan and view angles for reduced patient dose, scatter, and required photon flux, which is especially important for photon counting detectors (PCDs). Among the proposed dynamic bowtie designs, the piecewise-linear attenuator (Hsieh and Pelc, Med Phys. 2013;40:...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13272

    authors: Shunhavanich P,Hsieh SS,Pelc NJ

    更新日期:2019-01-01 00:00:00

  • Robust initialization of 2D-3D image registration using the projection-slice theorem and phase correlation.

    abstract:PURPOSE:The image registration literature comprises many methods for 2D-3D registration for which accuracy has been established in a variety of applications. However, clinical application is limited by a small capture range. Initial offsets outside the capture range of a registration method will not converge to a succe...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3366252

    authors: van der Bom MJ,Bartels LW,Gounis MJ,Homan R,Timmer J,Viergever MA,Pluim JP

    更新日期:2010-04-01 00:00:00

  • Neutron and gamma spectroscopy for clinical dosimetry.

    abstract::Neutron and photon energy spectra were measured in different depths and lateral positions in tissue-equivalent phantoms exposed to a therapeutical 14.1 MeV neutron beam. Intensity weighted mass energy absorption coefficients were derived for application in ionization chamber dosimetry in mixed neutron-gamma fields. Th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594744

    authors: Schmidt R,Magiera E,Scobel W

    更新日期:1980-09-01 00:00:00

  • General strategy for the protection of organs at risk in IMRT therapy of a moving body.

    abstract::We investigated protection strategies of organs at risk (OARs) in intensity modulated radiation therapy (IMRT). These strategies apply to delivery of IMRT to moving body anatomies that show relative displacement of OAR in close proximity to a tumor target. We formulated an efficient genetic algorithm which makes it po...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3132305

    authors: Abolfath RM,Papiez L

    更新日期:2009-07-01 00:00:00