Abstract:
PURPOSE:The purpose of this study was to assess, using an anthropomorphic digital phantom, the accuracy of algorithms in registering precontrast and contrast-enhanced computed tomography (CT) chest images for generation of iodine maps of the pulmonary parenchyma via temporal subtraction. MATERIALS AND METHODS:The XCAT phantom, with enhanced airway and pulmonary vessel structures, was used to simulate precontrast and contrast-enhanced chest images at various inspiration levels and added CT simulation for realistic system noise. Differences in diaphragm position were varied between 0 and 20 mm, with the maximum chosen to exceed the 95th percentile found in a dataset of 100 clinical subtraction CTs. In addition, the influence of whole body movement, degree of iodine enhancement, beam hardening artifacts, presence of nodules and perfusion defects in the pulmonary parenchyma, and variation in noise on the registration were also investigated. Registration was performed using three lung registration algorithms - a commercial (algorithm A) and a prototype (algorithm B) version from Canon Medical Systems and an algorithm from the MEVIS Fraunhofer institute (algorithm C). For each algorithm, we calculated the voxel-by-voxel difference between the true deformation and the algorithm-estimated deformation in the lungs. RESULTS:The median absolute residual error for all three algorithms was smaller than the voxel size (1.0 × 1.0 × 1.0 mm3 ) for up to an 8 mm diaphragm difference, which is the average difference in diaphragm levels found clinically, and increased with increasing difference in diaphragm position. At 20 mm diaphragm displacement, the median absolute residual error after registration was 0.85 mm (interquartile range, 0.51-1.47 mm) for algorithm A, 0.82 mm (0.50-1.40 mm) for algorithm B, and 0.91 mm (0.54-1.52 mm) for algorithm C. The largest errors were seen in the paracardiac regions and close to the diaphragm. The impact of all other evaluated conditions on the residual error varied, resulting in an increase in the median residual error lower than 0.1 mm for all algorithms, except in the case of whole body displacements for algorithm B, and with increased noise for algorithm C. CONCLUSION:Motion correction software can compensate for respiratory and cardiac motion with a median residual error below 1 mm, which was smaller than the voxel size, with small differences among the tested registration algorithms for different conditions. Perfusion defects above 50 mm will be visible with the commercially available subtraction CT software, even in poorly registered areas, where the median residual error in that area was 7.7 mm.
journal_name
Med Physjournal_title
Medical physicsauthors
Grob D,Oostveen L,Rühaak J,Heldmann S,Mohr B,Michielsen K,Dorn S,Prokop M,Kachelrieβ M,Brink M,Sechopoulos Idoi
10.1002/mp.13496subject
Has Abstractpub_date
2019-05-01 00:00:00pages
2264-2274issue
5eissn
0094-2405issn
2473-4209journal_volume
46pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract:PURPOSE:Image guidance is crucial for percutaneous tumor ablations, enabling accurate needle-like applicator placement into target tumors while avoiding tissues that are sensitive to injury and/or correcting needle deflection. Although ultrasound (US) is widely used for image guidance, magnetic resonance (MR) is prefer...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13958
更新日期:2020-03-01 00:00:00
abstract:PURPOSE:The purpose of this study is to investigate the feasibility of increasing the system spatial resolution and scanning speed of Hologic Selenia Dimensions digital breast tomosynthesis (DBT) scanner by replacing the rotating mammography x-ray tube with a specially designed carbon nanotube (CNT) x-ray source array,...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3694667
更新日期:2012-04-01 00:00:00
abstract::A PTW Riga diamond detector and LiF TLDs have been evaluated for use in proton beam dosimetry by comparing results of proton beam calibration with those obtained using thimble ionization chambers. The thimble ionization chambers were calibrated in terms of exposure while the TLDs and diamond detector were calibrated i...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597608
更新日期:1995-04-01 00:00:00
abstract::Monte Carlo dose calculations will potentially reduce systematic errors that may be present in currently used dose calculation algorithms. However, Monte Carlo calculations inherently contain random errors, or statistical uncertainty, the level of which decreases inversely with the square root of computation time. Our...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598916
更新日期:2000-03-01 00:00:00
abstract::A new factor for shifting isodoes curves for oblique Co-60 photon beams has been deduced. Like the two other known factors, this shift factor depends on the source-to-surface distance (SSD), the depth dose (D) and the derivative of D with depth. A comparison of corrected dose distributions has been made by using the t...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594688
更新日期:1980-05-01 00:00:00
abstract:PURPOSE:To characterize a new air vented ionization chamber technology, suitable to build detector arrays with small pixel pitch and independence of sensitivity on dose per pulse. METHODS:The prototype under test is a linear array of air vented ionization chambers, consisting of 80 pixels with 3.5 mm pixel pitch dista...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4945414
更新日期:2016-05-01 00:00:00
abstract:PURPOSE/OBJECTIVE:Couch and MLC tracking are two novel techniques to mitigate intrafractional tumor motion on a conventional linear accelerator, but both techniques still have residual dosimetric errors. Here, we first propose and experimentally validate a software tool to simulate couch and MLC tracking, and then use ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12104
更新日期:2017-03-01 00:00:00
abstract:PURPOSE:Tumor grading is an important part of breast cancer diagnosis and currently requires biopsy as its standard. Here, the authors investigate quantitative ultrasound parameters in locally advanced breast cancers that can potentially separate tumors from normal breast tissue and differentiate tumor grades. METHODS...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4852875
更新日期:2014-01-01 00:00:00
abstract:PURPOSE:The ability to monitor intrafractional tumor motion is essential for radiation therapy of thoracic and abdominal tumors. This study aims to develop a method to track lung tumor motion using intrafractional continuous ultrasound (US) and periodic cone-beam projection images (CBPI). METHODS:Time-sequenced b-mode...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13104
更新日期:2018-10-01 00:00:00
abstract::This study concerns the accuracy and precision of the IAEA/WHO LiF TLD system used in intercomparison by mail of absorbed doses from 60Co gamma-radiation and 4-25 MV x rays. The system employs 160 mg LiF powder in polystyrene capsules, which are placed at 5 or 7 cm depth in water and irradiated to doses close to 200 r...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594746
更新日期:1980-09-01 00:00:00
abstract::The hybrid algorithms developed recently for the reconstruction of fan-beam images possess computational and noise properties superior to those of the fan-beam filtered backprojection (FFBP) algorithm. However, the hybrid algorithms cannot be applied directly to a halfscan fan-beam sinogram because they require knowle...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1288239
更新日期:2000-09-01 00:00:00
abstract::Different methods exist to determine the air kerma calibration factor of an ionization chamber for the spectrum of a 192Ir high-dose-rate (HDR) or pulsed-dose-rate (PDR) source. An analysis of two methods to obtain such a calibration factor was performed: (i) the method recommended by [Goetsch et al., Med. Phys. 18, 4...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1791352
更新日期:2004-10-01 00:00:00
abstract:PURPOSE:The automated correct segmentation of left and right lungs is a nontrivial problem, because the tissue layer between both lungs can be quite thin. In the case of lung segmentation with left and right lung models, overlapping segmentations can occur. In this paper, the authors address this issue and propose a so...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4894817
更新日期:2014-10-01 00:00:00
abstract::Dose uniformity throughout the treatment volume is essential to precision radiation therapy. Tissue compensators are often used as a means to eliminate dose nonuniformity resulting from surface contour irregularities. This paper evaluates the accuracy of using an effective attenuation coefficient for calculating the t...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596561
更新日期:1990-01-01 00:00:00
abstract::The nuclear magnetic resonance phenomenon has given rise to both magnetic resonance imaging, which yields morphologic data, and magnetic resonance spectroscopy (MRS), which yields chemical data. In humans these data are derived principally from the resonances of the hydrogen nucleus in the low molecular weight compoun...
journal_title:Medical physics
pub_type: 杂志文章,评审
doi:10.1118/1.2975225
更新日期:2008-10-01 00:00:00
abstract:PURPOSE:Tumor motion during radiotherapy can cause a reduction in target dose coverage and an increase in healthy tissue exposure. Tumor motion is not strictly translational and often exhibits complex six degree-of-freedom (6DoF) translational and rotational motion. Although the dosimetric impact of prostate tumor tran...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14502
更新日期:2020-12-01 00:00:00
abstract:PURPOSE:A series of examples are presented in which potential errors in the delivery of radiation therapy were prevented through use of incident learning. These examples underscore the value of reporting near miss incidents. METHODS:Using a departmental incident learning system, eight incidents were noted over a two-y...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4760774
更新日期:2012-11-01 00:00:00
abstract:PURPOSE:The aim of this paper is to investigate the accuracy of a laser∕camera surface imaging system (Sentinel) when used on patients treated in the thorax or pelvic regions and to evaluate system employment conditions and patient setup procedures that provide more accurate results. METHODS:The system was tested on t...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4769428
更新日期:2013-01-01 00:00:00
abstract:PURPOSE:Plastic scintillation detectors are used for dosimetry in small radiation fields with high dose gradients, e.g., provided by β-emitting sources like 106 Ru/106 Rh eye plaques. A drawback is a background signal caused by Cerenkov radiation generated by electrons passing the optical fibers (light guides) of this ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12374
更新日期:2017-09-01 00:00:00
abstract::Using high-energy photon and electron beams, the response of two solid water parallel-plate chambers is evaluated against a PTW (Physicallsch-Technische Werkstatten) Farmer-type chamber. These two chambers are (1) a Memorial "Holt" chamber which was further modified by this author to take advantage of electrically con...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597074
更新日期:1993-03-01 00:00:00
abstract:OBJECTIVE:To develop an anthropomorphic, deformable and multimodal pelvis phantom with positron emission tomography extension for radiotherapy (ADAM PETer). METHODS:The design of ADAM PETer was based on our previous pelvis phantom (ADAM) and extended for compatibility with PET and use in 3T magnetic resonance imaging ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14597
更新日期:2020-11-18 00:00:00
abstract::A statistical analysis has been made of ionometrically measured parameters related to the central-axis output, the beam symmetry, the beam flatness, and the depth dose for the 6-MV x-ray beam from the Therac-6 linear accelerator. The means and coefficients of variation of the measurements are determined on a monthly b...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595642
更新日期:1984-09-01 00:00:00
abstract::Currently, two classes of the computational phantoms have been developed for dosimetry calculation: (1) stylized (or mathematical) and (2) voxel (or tomographic) phantoms describing human anatomy through mathematical surface equations and three-dimensional labeled voxel matrices, respectively. Mathematical surface equ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2912178
更新日期:2008-06-01 00:00:00
abstract:PURPOSE:To achieve more translatable preclinical research results, small animal irradiation needs to more closely simulate human radiotherapy. Although the clinical gold standard is intensity-modulated radiation therapy (IMRT), the direct translation of this method for small animals is impractical. In this study we des...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13872
更新日期:2019-12-01 00:00:00
abstract::Administration of x-ray contrast agents during heart catheterization examination increases the absorbed radiation dose in tissue. To estimate the dose absorbed by the blood of children undergoing diagnostic heart catheterization and angiocardiography, a number of measurements and calculations were conducted. First, en...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594613
更新日期:1979-11-01 00:00:00
abstract::The last 50 years have seen great advances in the accuracy of external beam radiation therapy. Geometrical uncertainties have been reduced from a centimeter or more in presimulation, skin-mark guided days to 1-2 mm in today's image-guided radiation therapy treatments. Medical physicists, with the support and guidance ...
journal_title:Medical physics
pub_type: 杂志文章,评审
doi:10.1118/1.2836420
更新日期:2008-03-01 00:00:00
abstract:PURPOSE:In computed tomography (CT), organ dose, effective dose, and risk index can be estimated from volume-weighted CT dose index (CTDI(vol)) or dose-length product (DLP) using conversion coefficients. Studies have investigated how these coefficients vary across scanner models, scan parameters, and patient size. Howe...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4754584
更新日期:2012-11-01 00:00:00
abstract::A detailed Monte Carlo study of the PTW-diamond solid state detector response in megavoltage photon beams (60Co gamma rays to 25 MV x rays) has been performed with the EGS4 Monte Carlo Code. The sensitive volume of the diamond detector is a disk of diameter 4.4 mm and thickness 0.40 mm. The phantom material was water ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598771
更新日期:1999-11-01 00:00:00
abstract::A method is described for calibration of 192Ir high-dose-rate (HDR) brachytherapy afterloading systems. Since NIST does not offer calibration of ionization chambers with the gamma-ray spectrum of iridium-192, an interpolation procedure is employed, using calibrations above (137Cs, 662 keV) and below (250 kVcp, 146-keV...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596649
更新日期:1991-05-01 00:00:00
abstract::Intensity modulated radiation therapy (IMRT) treatment planning typically considers beam optimization and beam delivery as separate tasks. Following optimization, a multi-leaf collimator (MLC) or other beam delivery device is used to generate fluence patterns for patient treatment delivery. Due to limitations and char...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1477230
更新日期:2002-06-01 00:00:00