Attenuation, scattering, and absorption of ultrasound in the skull bone.

Abstract:

PURPOSE:Measured values of ultrasound attenuation in bone represent a combination of different loss mechanisms. As a wave is transmitted from a fluid into bone, reflections occur at the interface. In the bone, mode conversion occurs between longitudinal and shear modes and the mechanical wave is scattered by its complex internal microstructure. Finally, part of the wave energy is absorbed by the bone and converted into heat. Due to the complexity of the wave propagation and the difficulty in performing measurements that are capable of separating the various loss mechanisms, there are currently no estimates of the absorption in bone. The aim of this paper is, thus, to quantify the attenuation, scattering, and thermal absorption in bone. METHODS:An attenuating model of wave propagation in bone is established and used to develop a three-dimensional finite difference time domain numerical algorithm. Hydrophone and optical heterodyne interferometer measurements of the acoustic field as well as a x-ray microtomography of the bone sample are used to drive the simulations and to measure the attenuation. The acoustic measurements are performed concurrently with an infrared camera that can measure the temperature elevation during insonication. A link between the temperature and the absorption via a three-dimensional thermal simulation is then used to quantify the absorption coefficients for longitudinal and shear waves in cortical bone. RESULTS:We demonstrate that only a small part of the attenuation is due to absorption in bone and that the majority of the attenuation is due to reflection, scattering, and mode conversion. In the nine samples of a human used for the study, the absorption time constant for cortical bone was determined to be 1.04 μs ± 28%. This corresponds to a longitudinal absorption of 2.7 dB/cm and a shear absorption of 5.4 dB/cm. The experimentally measured attenuation across the approximately 8 mm thick samples was 13.3 ± 0.97 dB/cm. CONCLUSIONS:This first measurement of ultrasound absorption in bone can be used to estimate the amount of heat deposition based on knowledge of the acoustic field.

journal_name

Med Phys

journal_title

Medical physics

authors

Pinton G,Aubry JF,Bossy E,Muller M,Pernot M,Tanter M

doi

10.1118/1.3668316

subject

Has Abstract

pub_date

2012-01-01 00:00:00

pages

299-307

issue

1

eissn

0094-2405

issn

2473-4209

journal_volume

39

pub_type

杂志文章
  • Unexpectedly large dose rate dependent output from a linear accelerator.

    abstract::During our routine calibration of a Varian Clinac-20 linear accelerator, the absorbed dose for a fixed monitor unit (mu) was found to decrease with increasing dose rate. Between dose rates of 100 and 500 mu/min, there was up to 20% difference in absorbed dose for a 20-MeV electron beam. The cause of this problem was a...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596192

    authors: Cheng PC,Kubo H

    更新日期:1988-09-01 00:00:00

  • Plan averaging for multicriteria navigation of sliding window IMRT and VMAT.

    abstract:PURPOSE:To describe a method for combining sliding window plans [intensity modulated radiation therapy (IMRT) or volumetric modulated arc therapy (VMAT)] for use in treatment plan averaging, which is needed for Pareto surface navigation based multicriteria treatment planning. METHODS:The authors show that by taking an...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4859295

    authors: Craft D,Papp D,Unkelbach J

    更新日期:2014-02-01 00:00:00

  • Fourier-based approach to interpolation in single-slice helical computed tomography.

    abstract::It has recently been shown that longitudinal aliasing can be a significant and detrimental presence in reconstructed single-slice helical computed tomography (CT) volumes. This aliasing arises because the directly measured data in helical CT are generally undersampled by a factor of at least 2 in the longitudinal dire...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1350583

    authors: La Rivière PJ,Pan X

    更新日期:2001-03-01 00:00:00

  • Technical Note: Identification of an optimal electromagnetic sensor for in vivo electromagnetic-tracked scintillation dosimeter for HDR brachytherapy.

    abstract:PURPOSE:Brachytherapy is a treatment modality which delivers large doses of radiation in a reduced number of visits. Since a small number of large dose-per-fraction is administered in high dose rate brachytherapy, ensuring the right dose is delivered is highly critical. In this work, a scintillation detector is coupled...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13508

    authors: Tho D,Beaulieu L

    更新日期:2019-05-01 00:00:00

  • SU-E-T-109: An Evaluation of a Newly Available Portal Dosimetry QA Tool for SRS Dynamic Arc and VMAT.

    abstract:PURPOSE:In our institute, the MatriXX has been used for IMRT, VMAT and dynamic arc QA. However, the small fields (<3cm) shaped by HDMLC for SRS dynamic arc (DA) present QA measurement issues when using the MatriXX due to its limited resolution (7.6 mm). A recently available portal dosimetry (PD) software tool in Eclips...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735167

    authors: Luo G,Crass J,Morales M,Ding G

    更新日期:2012-06-01 00:00:00

  • A segmented 32P source Monte Carlo model to derive AAPM TG-60 dosimetric parameters used for intravascular brachytherapy.

    abstract::A new high dose rate 20 mm 32P intravascular brachytherapy (IVB) beta source used with automated stepping has recently been introduced. The AAPM Task Group 60 recommends that beta IVB sources should have well characterized dosimetric parameters in water. In this study, Monte Carlo simulations (MCNPX v 2.4) were used t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1646651

    authors: Mourtada F,Soares CG,Horton JL

    更新日期:2004-03-01 00:00:00

  • Tolerance limits and methodologies for IMRT measurement-based verification QA: Recommendations of AAPM Task Group No. 218.

    abstract:PURPOSE:Patient-specific IMRT QA measurements are important components of processes designed to identify discrepancies between calculated and delivered radiation doses. Discrepancy tolerance limits are neither well defined nor consistently applied across centers. The AAPM TG-218 report provides a comprehensive review a...

    journal_title:Medical physics

    pub_type: 杂志文章,评审

    doi:10.1002/mp.12810

    authors: Miften M,Olch A,Mihailidis D,Moran J,Pawlicki T,Molineu A,Li H,Wijesooriya K,Shi J,Xia P,Papanikolaou N,Low DA

    更新日期:2018-04-01 00:00:00

  • A general model of microcirculatory blood flow effects in gradient sensitized MRI.

    abstract::A general expression is derived for the NMR signal from a fluid undergoing random directional flow such as encountered within the microcirculation. The dependence of the echo amplitude on flow velocity, sample morphology, and experimental parameters are described in terms of a temporal velocity autocorrelation functio...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597170

    authors: Kennan RP,Gao JH,Zhong J,Gore JC

    更新日期:1994-04-01 00:00:00

  • SU-E-T-16: Statistical Variability and Confidence Intervals for Planar Dose QA Pass Rates.

    abstract:PURPOSE:The most common metric for comparing measured to calculated dose planes is a pass rate generated using percent difference, distance-to-agreement (DTA), or some combination of the two (e.g. gamma evaluation). The grid of analyzed points often corresponds to a dosimeter array with low areal-density of point detec...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735070

    authors: Bailey D,Nelms B,Kumaraswamy L,Attwood K,Podgorsak M

    更新日期:2012-06-01 00:00:00

  • Energy dependent calibration of XR-QA2 radiochromic film with monochromatic and polychromatic x-ray beams.

    abstract:PURPOSE:This work investigates the energy response and dose-response curve determinations for XR-QA2 radiochromic film dosimetry system used for synchrotron radiation work and for quality assurance in diagnostic radiology, in the range of effective energies 18-46.5 keV. METHODS:Pieces of XR-QA2 films were irradiated, ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4939063

    authors: Di Lillo F,Mettivier G,Sarno A,Tromba G,Tomic N,Devic S,Russo P

    更新日期:2016-01-01 00:00:00

  • A simple model for transit dosimetry based on a water equivalent EPID.

    abstract:PURPOSE:The aim of this study was to demonstrate a new model for implementing a transit dosimetry system as a means of in vivo dose verification with a water equivalent electronic portal imaging device (WE-EPID) and a conventional treatment planning system (TPS). METHOD AND MATERIALS:A standard amorphous silicon (a-Si...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12742

    authors: Deshpande S,Blake SJ,Xing A,Metcalfe PE,Holloway LC,Vial P

    更新日期:2018-03-01 00:00:00

  • Assessment of image registration accuracy in three-dimensional transrectal ultrasound guided prostate biopsy.

    abstract:PURPOSE:Prostate biopsy, performed using two-dimensional (2D) transrectal ultrasound (TRUS) guidance, is the clinical standard for a definitive diagnosis of prostate cancer. Histological analysis of the biopsies can reveal cancerous, noncancerous, or suspicious, possibly precancerous, tissue. During subsequent biopsy s...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3298010

    authors: Karnik VV,Fenster A,Bax J,Cool DW,Gardi L,Gyacskov I,Romagnoli C,Ward AD

    更新日期:2010-02-01 00:00:00

  • MLC quality assurance techniques for IMRT applications.

    abstract::Intensity modulated radiotherapy (IMRT) requires extensive knowledge of multileaf collimator (MLC) leaf positioning accuracy, precision, and long-term reproducibility. We have developed a technique to efficiently measure the absolute position of each MLC leaf, over the range of leaf positions utilized in IMRT, based o...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1564091

    authors: Bayouth JE,Wendt D,Morrill SM

    更新日期:2003-05-01 00:00:00

  • Monte Carlo dosimetry for I125 and Pd103 eye plaque brachytherapy.

    abstract::A Monte Carlo study of dosimetry for eye plaque brachytherapy is performed. BrachyDose, an EGSnrc user code which makes use of Yegin's multi-geometry package, is used to fully model I125 (model 6711) and Pd103 (model 200) brachytherapy seeds and the standardized plaques of the Collaborative Ocular Melanoma Study (COMS...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3002412

    authors: Thomson RM,Taylor REP,Rogers DWO

    更新日期:2008-12-01 00:00:00

  • Characterization of difference of Gaussian filters in the detection of mammographic regions.

    abstract::In this article, we present a characterization of the effect of difference of Gaussians (DoG) filters in the detection of mammographic regions. DoG filters have been used previously in mammographic mass computer-aided detection (CAD) systems. As DoG filters are constructed from the subtraction of two bivariate Gaussia...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2358326

    authors: Catarious DM Jr,Baydush AH,Floyd CE Jr

    更新日期:2006-11-01 00:00:00

  • Noise texture and signal detectability in propagation-based x-ray phase-contrast tomography.

    abstract:PURPOSE:X-ray phase-contrast tomography (PCT) is a rapidly emerging imaging modality for reconstructing estimates of an object's three-dimensional x-ray refractive index distribution. Unlike conventional x-ray computed tomography methods, the statistical properties of the reconstructed images in PCT remain unexplored. ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3267548

    authors: Chou CY,Anastasio MA

    更新日期:2010-01-01 00:00:00

  • Characterization of tissue-specific pre-log Bayesian CT reconstruction by texture-dose relationship.

    abstract:PURPOSE:Tissue textures have been recognized as biomarkers for various clinical tasks. In computed tomography (CT) image reconstruction, it is important but challenging to preserve the texture when lowering x-ray exposure from full- toward low-/ultra-low dose level. Therefore, this paper aims to explore the texture-dos...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14449

    authors: Gao Y,Liang Z,Xing Y,Zhang H,Pomeroy M,Lu S,Ma J,Lu H,Moore W

    更新日期:2020-10-01 00:00:00

  • Automated segmentation of anatomic regions in chest radiographs using an adaptive-sized hybrid neural network.

    abstract::The purposes of this research are to investigate the effectiveness of our novel image features for segmentation of anatomic regions such as the lungs and the mediastinum in chest radiographs and to develop an automatic computerized method for image processing. A total of 85 screening chest radiographs from Johns Hopki...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598277

    authors: Tsujii O,Freedman MT,Mun SK

    更新日期:1998-06-01 00:00:00

  • ARPM-net: A novel CNN-based adversarial method with Markov random field enhancement for prostate and organs at risk segmentation in pelvic CT images.

    abstract:PURPOSE:The research is to develop a novel CNN-based adversarial deep learning method to improve and expedite the multi-organ semantic segmentation of CT images and to generate accurate contours on pelvic CT images. METHODS:Planning CT and structure datasets for 120 patients with intact prostate cancer were retrospect...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14580

    authors: Zhang Z,Zhao T,Gay H,Zhang W,Sun B

    更新日期:2020-11-05 00:00:00

  • Kymogram detection and kymogram-correlated image reconstruction from subsecond spiral computed tomography scans of the heart.

    abstract::Subsecond single-slice, multi-slice or cone-beam spiral computed tomography (SSCT, MSCT, CBCT) offer great potential for improving heart imaging. Together with the newly developed phase-correlated cardiac reconstruction algorithms 180 degrees MCD and 180 degrees MCI [Med. Phys. 27, 1881-1902 (2000)] or related algorit...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1487861

    authors: Kachelriess M,Sennst DA,Maxlmoser W,Kalender WA

    更新日期:2002-07-01 00:00:00

  • Effect of Contrast Agent Administration on Water Equivalent Diameter in CT.

    abstract:PURPOSE:Water equivalent diameter (WED) is the preferred surrogate for patient size in CT. It is better than geometric size surrogates and patient weight/height/BMI/age because it correlates the best with x-ray attenuation. The administration of oral/IV contrast agents increases a patient's attenuation and should there...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14721

    authors: Viggiano B,Rose S,Szczykutowicz TP

    更新日期:2021-01-13 00:00:00

  • A multi-institutional study to assess adherence to lung stereotactic body radiotherapy planning goals.

    abstract:PURPOSE:A multi-institutional planning study was performed to evaluate the frequency that current guidelines established by Radiation Therapy Oncology Group (RTOG) protocols and other literature for lung stereotactic body radiotherapy (SBRT) treatments are followed. METHODS:A total of 300 patients receiving lung SBRT ...

    journal_title:Medical physics

    pub_type: 杂志文章,多中心研究

    doi:10.1118/1.4926551

    authors: Woerner A,Roeske JC,Harkenrider MM,Fan J,Aydogan B,Koshy M,Laureckas R,Vali F,Campana M,Surucu M

    更新日期:2015-08-01 00:00:00

  • Automatic measurements of image geometry for online calibration of C-arm fluoroscopy.

    abstract::Calibrated C-arm fluoroscopy is used for a variety of surgical procedures where surgical tools and anatomical structures need to be located in space. Calibration can be performed online by combining measurements of the geometry of the image (center and radius) with measurements of a grid of fiducial markers. This arti...

    journal_title:Medical physics

    pub_type: 杂志文章,多中心研究

    doi:10.1118/1.1781331

    authors: Archip N,Rohling R

    更新日期:2004-09-01 00:00:00

  • Displacement-based binning of time-dependent computed tomography image data sets.

    abstract::Respiration can cause tumors in the thorax or abdomen to move by as much as 3 cm; this movement can adversely affect the planning and delivery of radiation treatment. Several techniques have been used to compensate for respiratory motion, but all have shortcomings. Manufacturers of computed tomography (CT) equipment h...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2044427

    authors: Fitzpatrick MJ,Starkschall G,Antolak JA,Fu J,Shukla H,Keall PJ,Klahr P,Mohan R

    更新日期:2006-01-01 00:00:00

  • High resolution digital autoradiographic and dosimetric analysis of heterogeneous radioactivity distribution in xenografted prostate tumors.

    abstract:PURPOSE:The first main aim of this study was to illustrate the absorbed dose rate distribution from 177Lu in sections of xenografted prostate cancer (PCa) tumors using high resolution digital autoradiography (DAR) and compare it with hypothetical identical radioactivity distributions of 90Y or 7 MeV alpha-particles. Th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4967877

    authors: Timmermand OV,Nilsson J,Strand SE,Elgqvist J

    更新日期:2016-12-01 00:00:00

  • Monitoring radiation use in cardiac fluoroscopy imaging procedures.

    abstract:PURPOSE:Timely identification of systematic changes in radiation delivery of an imaging system can lead to a reduction in risk for the patients involved. However, existing quality assurance programs involving the routine testing of equipment performance using phantoms are limited in their ability to effectively carry o...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3524224

    authors: Stevens NT,Steiner SH,Smith IR,MacKay RJ

    更新日期:2011-01-01 00:00:00

  • DMLC tracking and gating can improve dose coverage for prostate VMAT.

    abstract:PURPOSE:To assess and compare the dosimetric impact of dynamic multileaf collimator (DMLC) tracking and gating as motion correction strategies to account for intrafraction motion during conventionally fractionated prostate radiotherapy. METHODS:A dose reconstruction method was used to retrospectively assess the dose d...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4892605

    authors: Colvill E,Poulsen PR,Booth JT,O'Brien RT,Ng JA,Keall PJ

    更新日期:2014-09-01 00:00:00

  • General strategy for the protection of organs at risk in IMRT therapy of a moving body.

    abstract::We investigated protection strategies of organs at risk (OARs) in intensity modulated radiation therapy (IMRT). These strategies apply to delivery of IMRT to moving body anatomies that show relative displacement of OAR in close proximity to a tumor target. We formulated an efficient genetic algorithm which makes it po...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3132305

    authors: Abolfath RM,Papiez L

    更新日期:2009-07-01 00:00:00

  • Evaluation of the accuracy of fetal dose estimates using TG-36 data.

    abstract::The American Association of Physicists in Medicine Radiation Therapy Committee Task Group 36 report (TG-36) provides guidelines for managing radiation therapy of pregnant patients. Included in the report are data that can be used to estimate the dose to the fetus. The purpose of this study is to evaluate the accuracy ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2710332

    authors: Kry SF,Starkschall G,Antolak JA,Salehpour M

    更新日期:2007-04-01 00:00:00

  • Optimization of power deposition and a heating strategy for external ultrasound thermal therapy.

    abstract::The purpose of this paper is to examine the thermal dose distribution, to configure the optimal absorbed power deposition, and to design an appropriate heating strategy for ultrasound thermal therapy. This work employs simulation programs, which are based on the transient bio-heat transfer equation and an ideal absorb...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1406516

    authors: Lin WL,Liang TC,Yen JY,Liu HL,Chen YY

    更新日期:2001-10-01 00:00:00