Abstract:
:The purpose of this paper is to examine the thermal dose distribution, to configure the optimal absorbed power deposition, and to design an appropriate heating strategy for ultrasound thermal therapy. This work employs simulation programs, which are based on the transient bio-heat transfer equation and an ideal absorbed power deposition or an ideal temperature elevation within a cube of tissue, to study the optimal absorbed power deposition. Meanwhile, a simplified model of a scanned ultrasound transducer power deposition (a cone with convergent/divergent shape) is used to investigate the heating strategy for a large tumor with a sequence of heating pulses. The distribution of thermal dose equivalence defined by Sapareto and Dewey is used to evaluate the heating result for a set of given parameters. The parameters considered are the absorbed power density, heating duration, temperature elevation, blood perfusion, and the size of heating cube. The results demonstrate that the peak temperature is the key factor determining the thermal dose for this short-duration heating. Heat conduction has a very strong influence on the responses of temperature and thermal dose for a small heating cube and the boundary portion of a large heating cube. Hence, for obtaining the same therapeutic result, a higher power density is required for these two conditions to compensate the great temperature difference between the heating cube and the surrounding tissue. The influence of blood perfusion on the thermal dose is negligible on the boundary portion of the heating cube, while in the central portion it may become a crucial factor as a lower power density is used in this portion to save the delivered energy. When using external ultrasound heating method to treat a large tumor, the size of heating unit, the sequence of heating pulses, and the cooling-time interval between the consecutive heating pulses are the important factors to be determined to have an appropriate treatment within a reasonable overall treatment time.
journal_name
Med Physjournal_title
Medical physicsauthors
Lin WL,Liang TC,Yen JY,Liu HL,Chen YYdoi
10.1118/1.1406516subject
Has Abstractpub_date
2001-10-01 00:00:00pages
2172-81issue
10eissn
0094-2405issn
2473-4209journal_volume
28pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract::A computer dose model for a low energy gamma-emitting stent in a heterogeneous medium is described. The method is based on the Sievert model which is adapted to the dose-point-kernel (DPK) model to compute the dose distribution about filtered gamma sources (Sievert-DPK model). The new gamma stent model can take into a...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1380214
更新日期:2001-07-01 00:00:00
abstract:PURPOSE:Incorporating training into image segmentation is a good approach to achieve additional robustness. This work aims to develop an effective strategy to utilize shape prior knowledge, so that the segmentation label evolution can be driven toward the desired global optimum. METHODS:In the variational image segmen...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4945046
更新日期:2016-05-01 00:00:00
abstract:PURPOSE:It is very important for calculation of clinical indices and diagnosis to detect thyroid nodules from ultrasound images. However, this task is a challenge mainly due to heterogeneous thyroid nodules with distinct components are similar to background in ultrasound images. In this study, we employ cascade deep co...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12134
更新日期:2017-05-01 00:00:00
abstract:PURPOSE:Talbot-Lau x-ray interferometry provides information about the scattering and refractive properties of an object - in addition to the object's attenuation features. Until recently, this method was ineligible for imaging human-sized objects as it is challenging to adapt Talbot-Lau interferometers (TLIs) to the r...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12889
更新日期:2018-06-01 00:00:00
abstract:PURPOSE:Severe artifacts in kilovoltage-CT simulation images caused by large metallic implants can significantly degrade the conspicuity and apparent CT Hounsfield number of targets and anatomic structures, jeopardize the confidence of anatomical segmentation, and introduce inaccuracies into the radiation therapy treat...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4762814
更新日期:2012-12-01 00:00:00
abstract:PURPOSE:To investigate how using different sets of decision criteria impacts the quality of intensity modulated radiation therapy (IMRT) plans obtained by multiobjective optimization. METHODS:A multiobjective optimization evolutionary algorithm (MOEA) was used to produce sets of IMRT plans. The MOEA consisted of two i...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3589128
更新日期:2011-06-01 00:00:00
abstract:PURPOSE:Automated segmentation could improve the efficiency of modeling-based pelvic organ prolapse (POP) evaluations. However, segmentation performance is limited by the blurry soft tissue boundaries. In this study, we aimed to present a hybrid solution for uterus, rectum, bladder, and levator ani muscle segmentation ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14377
更新日期:2020-09-01 00:00:00
abstract::Mammography is the most effective method for breast cancer screening available today. However, the low positive predictive value of breast biopsy resulting from mammogram interpretation leads to approximately 70% unnecessary biopsies with benign outcomes. To reduce the high number of unnecessary breast biopsies, sever...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2786864
更新日期:2007-11-01 00:00:00
abstract:PURPOSE:To quantify the needle tip detection errors in ultrasound images due to bevel-tip orientation in relation to the location on template grid. METHODS:Transrectal ultrasound (TRUS) system (BK Medical) with physical template grid and 18-gauge bevel-tip (20-deg beveled angle) brachytherapy needle (Bard Medical, Cov...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4734916
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:The treatment of thoracic cancer using external beam radiation requires an optimal selection of the radiation beam directions to ensure effective coverage of the target volume and to avoid unnecessary treatment of normal healthy tissues. Intensity modulated radiation therapy (IMRT) planning is a lengthy process...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4908000
更新日期:2015-04-01 00:00:00
abstract::A commercial optical system developed by Solid Photography, Inc., has been used to generate precise paraffin--polyethylene tissue compensators. A program with the objective of constructing a medical facility has been undertaken to access patient topology for treatment planning, tissue-compensator fabrication, and pati...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594447
更新日期:1978-11-01 00:00:00
abstract:PURPOSE:Previous studies have shown atlas-based segmentation using a single best matched (SBM) atlas subject can significantly reduce contouring time. A new multi-atlas approach has been shown to provide greater accuracy than SBM for cancer of the head and neck. The goal of this study was to evaluate the multi-atlas te...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4734942
更新日期:2012-06-01 00:00:00
abstract::It is well established that the diffusion approximation (DA) is valid for light propagation in highly scattering media, but it breaks down in nonscattering void regions. The methods that handle the void with refractive index matched boundary were previously developed. For the void with refractive index mismatched boun...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1766418
更新日期:2004-08-01 00:00:00
abstract:PURPOSE:Mega-voltage cone-beam CT (MVCBCT) imaging can be used to monitor changes in neck flexion and calculate the true spinal cord dose during radiotherapy. To sum the dose over multiple fractions and compare with the planned dose requires deformable image registration. This study investigates the accuracy of deforma...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4734919
更新日期:2012-06-01 00:00:00
abstract::Monte Carlo calculations have been performed for the purpose of characterizing the dosimetric properties of three brachytherapy sources. The three sources are manufactured by Syncor Pharmaceuticals Inc. and consist of two 125I seeds (BT-125-1 and BT-125-2) and one 103Pd seed (BT-103-3). The BT-125-1 and BT-125-2 seed ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1469627
更新日期:2002-05-01 00:00:00
abstract:PURPOSE:Alpha-emitting radionuclides exhibit a potential advantage for cancer treatments because they release large amounts of ionizing energy over a few cell diameters (50-80 μm), causing localized, irreparable double-strand DNA breaks that lead to cell death. Radioimmunotherapy (RIT) approaches using monoclonal antib...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4921997
更新日期:2015-07-01 00:00:00
abstract::A detailed derivation is presented of the formulas required to determine Ngas and Dmed in the AAPM TG-21 dosimetry protocol. This protocol specifies how to determine the absorbed dose in an electron or photon beam when using exposure or absorbed dose calibrated ion chambers. It is shown that the expression given in TG...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596292
更新日期:1988-01-01 00:00:00
abstract::For Monte Carlo linac simulations and patient dose calculations, it is important to accurately determine the phase space parameters of the initial electron beam incident on the target. These parameters, such as mean energy and radial intensity distribution, have traditionally been determined by matching the calculated...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2168433
更新日期:2006-04-01 00:00:00
abstract:PURPOSE:Radiochromic film provides dose measurement at high spatial resolution, but often is not preferred for routine evaluation of patient-specific intensity modulated radiation therapy (IMRT) plans owing to ease-of-use factors. The authors have established an efficient protocol that combines calibration and measurem...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4754797
更新日期:2012-10-01 00:00:00
abstract:PURPOSE:To increase diagnostic accuracy of breast MRI by increasing temporal resolution and more accurately sampling the early kinetics of contrast media uptake. We tested the feasibility of accelerating bilateral breast DCE-MRI by reducing the FOV, allowing aliasing, and unfolding the resulting images. METHODS:Previo...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12747
更新日期:2018-03-01 00:00:00
abstract:PURPOSE:Couch and MLC tracking are two promising methods for real-time motion compensation during radiation therapy. So far, couch and MLC tracking experiments have mainly been performed by different research groups, and no direct comparison of couch and MLC tracking of volumetric modulated arc therapy (VMAT) plans has...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4946815
更新日期:2016-05-01 00:00:00
abstract:PURPOSE:By means of Monte Carlo (MC) simulations and indirect measurements, we have evaluated the maximum dose rates achievable with conventional x-ray tubes and related them to FLASH therapy dose rates of >40 Gy/s. METHODS:Monte Carlo models of two 160 kV x-ray tubes, the 3-kW MXR-160/22 and the 6-kW MXR-165, were bu...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13858
更新日期:2019-12-01 00:00:00
abstract:PURPOSE:The use of 4D computed tomography (4D-CT) of the lung is important in lung cancer radiotherapy for tumor localization and treatment planning. Sometimes, dense sampling is not acquired along the superior-inferior direction. This disadvantage results in an interslice thickness that is much greater than in-plane v...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4899185
更新日期:2014-11-01 00:00:00
abstract:PURPOSE:New technology has been developed to treat age-related macular degeneration (AMD) using 100 kVp pencil-beams that enter the patient through the radio-resistant sclera with a depth of interest between 1.6 and 2.6 cm. Measurement of reference and relative dose in a kilovoltage x-ray beam with a 0.42 cm diameter f...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4863482
更新日期:2014-02-01 00:00:00
abstract::A series of experiments has been carried out in order to characterize a miniannular phased array applicator prior to possible clinical implementation. The energy deposition patterns over the frequency range of 100 to 200 MHz were determined in several human limb models of different complexities by measuring the electr...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596037
更新日期:1987-07-01 00:00:00
abstract:PURPOSE:To evaluate dependence of measured dose on size and location of region of interest (ROI) in Gafchromic EBT3 film dosimetry. METHODS:Gafchromic EBT3 films were irradiated perpendicularly using the 6MV beam from a linear accelerator at 10 cm depth (100 cm SSD) of a 30 × 30 × 20 cm3 solid water phantom for a rang...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12885
更新日期:2018-05-01 00:00:00
abstract:PURPOSE:Elastography using computer tomography (CT) is a promising methodology that can provide patient-specific regional distributions of lung biomechanical properties. The purpose of this paper is to investigate the feasibility of performing elastography using simulated lower dose CT scans. METHODS:A cohort of eight...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14112
更新日期:2020-08-01 00:00:00
abstract::The objective of this work was to create a comprehensive online tool to evaluate and review the performance of quality assurance measurements that assess beam output and profile constancy as soon as they are acquired using statistical process control. As part of routine quality assurance: output, flatness and symmetry...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4740111
更新日期:2012-07-01 00:00:00
abstract::Transmission data for 4-MV bremsstrahlung beams have been measured with a combination of lead and aluminum attenuators. From these data, the original energy spectra have been reconstructed using an iterative least-squares technique, previously evaluated by simulation studies. The spectra on the central axis for three ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595356
更新日期:1983-11-01 00:00:00
abstract::Breast density is a strong predictor of the failure of mammography screening to detect breast cancer and is a strong predictor of the risk of developing breast cancer. The many imaging options that are now available for imaging dense breasts show great promise, but there is still the question of determining which wome...
journal_title:Medical physics
pub_type: 杂志文章,评审
doi:10.1118/1.4935141
更新日期:2015-12-01 00:00:00