Abstract:
:It is well established that the diffusion approximation (DA) is valid for light propagation in highly scattering media, but it breaks down in nonscattering void regions. The methods that handle the void with refractive index matched boundary were previously developed. For the void with refractive index mismatched boundary, no theory is yet available. We derived the finite element method that can handle the void problem with refractive index mismatch on its boundary. The method uses the ray tracing to account for the multiple reflections of rays within the void due to refractive index mismatch on the void boundary. We applied the method to the four-layer adult head model and the good agreements with Monte Carlo simulation results were found in the mean time of flight data.
journal_name
Med Physjournal_title
Medical physicsauthors
Lee JH,Kim S,Kim YTdoi
10.1118/1.1766418subject
Has Abstractpub_date
2004-08-01 00:00:00pages
2237-48issue
8eissn
0094-2405issn
2473-4209journal_volume
31pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract::Computed tomography colonography (CTC) is a minimally invasive method that allows the evaluation of the colon wall from CT sections of the abdomen/pelvis. The primary goal of CTC is to detect colonic polyps, precursors to colorectal cancer. Because imperfect cleansing and distension can cause portions of the colon wal...
journal_title:Medical physics
pub_type: 临床试验,杂志文章
doi:10.1118/1.1796171
更新日期:2004-10-01 00:00:00
abstract:PURPOSE:New preclinical image-guided irradiators and treatment planning systems represent a huge progress in radiobiology. Nevertheless, quality control of preclinical treatments is not as advanced as in clinical radiotherapy and in vivo dosimetry is less developed. In this study, we evaluate the use of a scintillating...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13903
更新日期:2020-01-01 00:00:00
abstract::We have reexamined the problem of estimating the luminal area of an elliptically shaped coronary artery cross section from two or more radiographic diameter measurements. The expected error is found to be much smaller than the maximum potential error. In the cases of two orthogonal views, closed form expressions have ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596296
更新日期:1988-07-01 00:00:00
abstract:PURPOSE:For the purpose of size-specific dose estimation, information regarding patient attenuation is required. The purpose of this work is to describe a method for measuring patient attenuation and expressing the results in terms of a water cylinder, with cross sectional area A(w), which would absorb the same average...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4754303
更新日期:2012-11-01 00:00:00
abstract:PURPOSE:The authors use reduced-order constrained optimization (ROCO) to create clinically acceptable IMRT plans quickly and automatically for advanced lung cancer patients. Their new ROCO implementation works with the treatment planning system and full dose calculation used at Memorial Sloan-Kettering Cancer Center (M...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3575416
更新日期:2011-05-01 00:00:00
abstract::One of the important features of the Siemens Virtual Wedge (VW) is that the VW factor (VWF) is approximately equal to unity for all beams with a total deviation for a given wedge no greater than 0.05, as specified by Siemens. In this note we report the observed dependence of VWF on dose calibration (cGy/MU), monitor u...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1344204
更新日期:2001-02-01 00:00:00
abstract:PURPOSE:The authors have previously reported the advantages of high-sensitivity single-photon emission computed tomography (SPECT) systems for imaging structures located deep inside the brain. DaTscan (Isoflupane I-123) is a dopamine transporter (DaT) imaging agent that has shown potential for early detection of Parkin...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4794488
更新日期:2013-04-01 00:00:00
abstract:PURPOSE:A critical step in adaptive radiotherapy (ART) workflow is deformably registering the simulation CT with the daily or weekly volumetric imaging. Quantifying the deformable image registration accuracy under these circumstances is a complex task due to the lack of known ground-truth landmark correspondences betwe...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12321
更新日期:2017-08-01 00:00:00
abstract::Magnetic beam scanning allows one to spread proton beam over the desired radiation field area, improving beam utilization and conformity to the target area. This article discusses generic scan forms for generating uniform circular and rectangular fields and establishes criteria that can be applied to optimize selected...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3158731
更新日期:2009-08-01 00:00:00
abstract::Like Medical Physics, Imaging Informatics encompasses concepts touching every aspect of the imaging chain from image creation, acquisition, management and archival, to image processing, analysis, display and interpretation. The two disciplines are in fact quite complementary, with similar goals to improve the quality ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735777
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:This paper presents the application of MAGIC-f gel in a three-dimensional dose distribution measurement and its ability to accurately measure the dose distribution from a tomotherapy unit. METHODS:A prostate intensity-modulated radiation therapy (IMRT) irradiation was simulated in the gel phantom and the treat...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4704496
更新日期:2012-05-01 00:00:00
abstract::Neutron cross sections for nonelastic and elastic reactions on a range of elements have been evaluated for incident energies up to 150 MeV. These cross sections agree well with experimental cross section data for charged-particle production as well as neutron and photon production. Therefore they can be used to determ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598601
更新日期:1999-06-01 00:00:00
abstract:PURPOSE:Intensity-Modulated Radiation Therapy (IMRT), including its variations (including IMRT, Volumetric Arc Therapy (VMAT), and Tomotherapy), is a widely used and critically important technology for cancer treatment. It is a knowledge-intensive technology due not only to its own technical complexity, but also to the...
journal_title:Medical physics
pub_type: 杂志文章,评审
doi:10.1002/mp.13526
更新日期:2019-06-01 00:00:00
abstract::Head-scatter factors of symmetric square and rectangular fields (field center on the central beam axis) defined by the upper (Y) and lower (X) jaws for 6 and 15 MV photon beams from 2300CD and 600C accelerators (Varian Associates, Inc., Palo Alto, CA) were measured, as well as those for fields shaped by the Y jaws and...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597617
更新日期:1995-08-01 00:00:00
abstract::A simple modification is presented for two commercially available hyperthermia applicators which dramatically improves the regulation and dynamic control of the temperature at the bolus/tissue interface. This alteration requires the addition of a variable speed pump, bubble trap, simple heat exchanger, and a few minor...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597196
更新日期:1994-09-01 00:00:00
abstract:PURPOSE:To characterize the modulation transfer function (MTF) of proton/carbon radiography using Monte Carlo simulations. To assess the spatial resolution of proton/carbon radiographic imaging. METHODS:A phantom was specifically modeled with inserts composed of two materials with three different densities of bone and...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4819816
更新日期:2013-09-01 00:00:00
abstract:PURPOSE:In this study the Octavius detector 729 ionization chamber (IC) array with the Octavius 4D phantom was characterized for flattening filter (FF) and flattening filter free (FFF) static and rotational beams. The device was assessed for verification with FF and FFF RapidArc treatment plans. METHODS:The response o...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4817482
更新日期:2013-09-01 00:00:00
abstract:PURPOSE:To evaluate a simple, semi-automated lung mass estimation method on CT scans from a variety of acquisition techniques for mass correction of MIRD dose estimates. METHODS:CT scans from ten patients undergoing stereotactic body radiation therapy treatment planning on a GE DST PET/CT scanner were analyzed retrosp...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4734654
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:In this article, the authors studied the feasibility of estimating regional mechanical properties in cerebral aneurysms, integrating information extracted from imaging and physiological data with generic computational models of the arterial wall behavior. METHODS:A data assimilation framework was developed to ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3355933
更新日期:2010-04-01 00:00:00
abstract:PURPOSE:To identify which physical properties of nanoparticles are correlated with the survival fraction of cells exposed in vitro to low-energy protons in combination with nanoparticles. METHODS:The Geant4 simulation toolkit (version 10.3) was used to model nanoparticles of different sizes (5-50 nm) and materials (Ti...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12362
更新日期:2017-08-01 00:00:00
abstract::A single-field rotational total skin electron irradiation technique has recently been developed at the McGill University for treatment of skin malignancies. The dose received by a given surface point during rotation in a uniform large electron field depends on the radius of rotation of the surface point, on the local ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595524
更新日期:1984-07-01 00:00:00
abstract:PURPOSE:4d cone-beam computed tomography (CBCT) scans are usually reconstructed by extracting the motion information from the 2d projections or an external surrogate signal, and binning the individual projections into multiple respiratory phases. In this "after-the-fact" binning approach, however, projections are uneve...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4817479
更新日期:2013-09-01 00:00:00
abstract::In this study, BrachyDose, a recently developed EGSnrc Monte Carlo code for rapid brachytherapy dose calculations, has been benchmarked by reproducing previously published dosimetry parameters for three brachytherapy seeds with varied internal structure and encapsulation. Calculations are performed for two 125I seeds ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2400843
更新日期:2007-02-01 00:00:00
abstract:PURPOSE:The treatment of moving targets with scanned proton beams is challenging. For motion mitigation, an Active Breathing Coordinator (ABC) can be used to assist breath-holding. The delivery of pencil beam scanning fields often exceeds feasible breath-hold durations, requiring high breath-hold reproducibility. We ev...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13195
更新日期:2018-12-01 00:00:00
abstract::Radiation sensitive gels have been used as dosimeters for clinical dose verification of different radiation therapy modalities. However, the use of gels is not widespread, because careful techniques are required to achieve the dose precision and accuracy aimed for in clinical dose verification. Here, the introduction ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2712042
更新日期:2007-04-01 00:00:00
abstract:PURPOSE:We describe the acceptance testing, commissioning, periodic quality assurance, and workflow procedures developed for the first clinically implemented magnetic resonance imaging-guided radiation therapy (MR-IGRT) system for real-time tracking and beam control. METHODS:The system utilizes real-time cine imaging ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13002
更新日期:2018-05-28 00:00:00
abstract:PURPOSE:A practical detector structure is proposed to achieve stable avalanche multiplication gain in direct-conversion amorphous selenium radiation detectors. METHODS:The detector structure is referred to as a field-shaping multi-well avalanche detector. Stable avalanche multiplication gain is achieved by eliminating...
journal_title:Medical physics
pub_type: 信件
doi:10.1118/1.4769110
更新日期:2013-01-01 00:00:00
abstract:PURPOSE:To evaluate the replacement of Cerrobend by copper for electron beam cutouts. METHODS:The dosimetric comparisons for circular copper-and Cerrobend-cutouts with diameters (1.0, 2.0, 3.0, 5.0, 7.5, 10.0, and 12.5 cm) were made using electron beams with energies (6, 9, 12, 16, and 20 MeV) from 3 Varian accelerato...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735336
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:This paper provides a comparison between a fast, commercial, in-patient Monte Carlo dose calculation algorithm (GPUMCD) and geant4. It also evaluates the dosimetric impact of the application of an external 1.5 T magnetic field. METHODS:A stand-alone version of the Elekta™ GPUMCD algorithm, to be used within th...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4939808
更新日期:2016-02-01 00:00:00
abstract:PURPOSE:Calculations of deoxyribonucleic acid (DNA) damages involve many parameters in the computation process. As these parameters are often subject to uncertainties, it is of central importance to comprehensively quantify their impacts on DNA single-strand break (SSB) and double-strand break (DSB) yields. This has be...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14036
更新日期:2020-04-01 00:00:00