Dynamic field-of-view imaging to increase temporal resolution in the early phase of contrast media uptake in breast DCE-MRI: A feasibility study.

Abstract:

PURPOSE:To increase diagnostic accuracy of breast MRI by increasing temporal resolution and more accurately sampling the early kinetics of contrast media uptake. We tested the feasibility of accelerating bilateral breast DCE-MRI by reducing the FOV, allowing aliasing, and unfolding the resulting images. METHODS:Previous experience with an "ultrafast" protocol for bilateral breast DCE-MRI (6-10 s temporal resolution) showed that the number of significantly enhancing voxels is very low in the first 30-45 s after contrast media injection. This suggests that overlap of enhancing voxels in aliased images will be very infrequent. Therefore, aliased images can be acquired during the first 30-45 s after contrast media injection and unfolded to produce full-FOV images with few errors. In a proof-of-principle test, aliased images were simulated from the first 30 s of full-FOV acquisitions. Cases with relatively dense early enhancement were selected to test this method in a worst-case scenario. In an initial test, an FOV of 60% the size of the full FOV was simulated. To reduce the probability of errors due to overlapping voxels in aliased images, we then tested a dynamic FOV approach. The FOV was progressively increased so that enhancing voxels could not overlap at multiple time-points, and areas where enhancing voxels overlapped at a given time-point could be unfolded by interpolating between the preceding and subsequent time-points (acquired with different FOVs). The simulated FOV sizes for each of the time-points were 31%, 44%, and 77% of the full FOV. Subtraction images (post- minus precontrast) were generated for aliased images and filtered to select significantly enhancing voxels. Comparison of early, highly aliased images, with later, less aliased images then helped to identify the true locations of enhancing voxels. RESULTS:In the initial aliasing simulations, an average of 2.9% of the enhancing voxels above the chest wall overlapped in the aliased images (range 0.1%-6.7%). The similarity between simulated unfolded images and the correct full-FOV images, evaluated using CW-SSIM (complex wavelet similarity index), was 0.50 ± 0.26, 0.76 ± 0.09, and 0.80 ± 0.10 for the first, second, and third time-point, respectively (numbers closer to 1 indicate more similar images). For the dynamic FOV tests, an average of 11% of the enhancing voxels above the chest wall overlapped (range 0%-40%) due to greater aliasing at early time-points. Despite more voxels overlapping, the CW-SSIM values for the data acquired with dynamic FOVs were 0.64 ± 0.25, 0.93 ± 0.04, and 0.97 ± 0.02 for the first, second, and third time-points, respectively. CONCLUSIONS:Dynamic FOV imaging allows accelerated bilateral breast DCE-MRI during the early contrast media uptake phase. This method relies on the sparsity of enhancement at the early phases of DCE-MRI of the breast. The results of simulations suggest that dynamic FOV imaging and unfolding produces images that are very close to fully sampled images, and allows temporal resolution as high as 2 s per image.

journal_name

Med Phys

journal_title

Medical physics

authors

Pineda FD,Easley TO,Karczmar GS

doi

10.1002/mp.12747

subject

Has Abstract

pub_date

2018-03-01 00:00:00

pages

1050-1058

issue

3

eissn

0094-2405

issn

2473-4209

journal_volume

45

pub_type

杂志文章
  • Characterization of the nanoDot OSLD dosimeter in CT.

    abstract:PURPOSE:The extensive use of computed tomography (CT) in diagnostic procedures is accompanied by a growing need for more accurate and patient-specific dosimetry techniques. Optically stimulated luminescent dosimeters (OSLDs) offer a potential solution for patient-specific CT point-based surface dosimetry by measuring a...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4914398

    authors: Scarboro SB,Cody D,Alvarez P,Followill D,Court L,Stingo FC,Zhang D,McNitt-Gray M,Kry SF

    更新日期:2015-04-01 00:00:00

  • Region-oriented CT image representation for reducing computing time of Monte Carlo simulations.

    abstract:PURPOSE:We propose a new method for efficient particle transportation in voxelized geometry for Monte Carlo simulations. We describe its use for calculating dose distribution in CT images for radiation therapy. MATERIAL AND METHODS:The proposed approach, based on an implicit volume representation named segmented volum...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2884854

    authors: Sarrut D,Guigues L

    更新日期:2008-04-01 00:00:00

  • Introduction of heat map to fidelity assessment of compressed CT images.

    abstract:PURPOSE:This study aimed to introduce heat map, a graphical data presentation method widely used in gene expression experiments, to the presentation and interpretation of image fidelity assessment data of compressed computed tomography (CT) images. METHODS:The authors used actual assessment data that consisted of five...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3611046

    authors: Lee H,Kim B,Kim KJ,Seo J,Park S,Shin YG,Lee KH

    更新日期:2011-08-01 00:00:00

  • SU-E-T-610: Impact of Variable Beam Spot Size on Treatment Time in Particle Therapy.

    abstract:PURPOSE:The dosimetric advantage of particle therapy comes with a much higher infrastructure investment and operation costs. Increasing patient throughput is a key factor to manage operation costs. We investigate the impact of variable beam spot sizes on treatment time and discuss the tradeoffs involved. METHODS:The f...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735699

    authors: Riofrio D,Sellner S,Cabal G,Keyes R,Holzscheiter M,Jaekel O,Luan S

    更新日期:2012-06-01 00:00:00

  • Quantitative impact of changes in marrow cellularity, skeletal size, and bone mineral density on active marrow dosimetry based upon a reference model.

    abstract:PURPOSE:The hematopoietically active tissues of skeletal bone marrow are a prime target for computational dosimetry given potential risks of leukemia and, at higher dose levels, acute marrow toxicity. The complex three-dimensional geometry of trabecular spongiosa, however, complicates schema for dose assessment in such...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12002

    authors: Geyer AM,Schwarz BC,Hobbs RF,Sgouros G,Bolch WE

    更新日期:2017-01-01 00:00:00

  • A dosimetry review system for cooperative group research.

    abstract::The validity of conclusions drawn from multi-institutional radiotherapy studies is dependent upon the degree to which participating hospitals adhere to study requirements. A major effort undertaken by the Quality Assurance Review Center (QARC) assesses whether or not patient data which are deemed evaluable actually co...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595221

    authors: Reinstein LE,McShan D,Glicksman AS

    更新日期:1982-03-01 00:00:00

  • Image reconstruction for positron emission tomography based on patch-based regularization and dictionary learning.

    abstract:PURPOSE:Positron emission tomography (PET) is an important tool for nuclear medical imaging. It has been widely used in clinical diagnosis, scientific research, and drug testing. PET is a kind of emission computed tomography. Its basic imaging principle is to use the positron annihilation radiation generated by radionu...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13804

    authors: Zhang W,Gao J,Yang Y,Liang D,Liu X,Zheng H,Hu Z

    更新日期:2019-11-01 00:00:00

  • Three-dimensional dose reconstruction of breast cancer treatment using portal imaging.

    abstract::In this study, we present an algorithm for three-dimensional (3-D) dose reconstruction using portal images obtained with an electronic portal imaging device (EPID). For this purpose an algorithm for 2-D dose reconstruction, which was previously developed in our institution, was adapted. The external contour of the pat...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1589496

    authors: Louwe RJ,Damen EM,van Herk M,Minken AW,Törzsök O,Mijnheer BJ

    更新日期:2003-09-01 00:00:00

  • Displacement corrections used in absorbed dose determination.

    abstract::When an (exposure) calibrated ionization chamber is used for the determination of absorbed dose from a photon beam, the reading of the instrument must be multiplied by a number of factors, one of which is an attenuation correction for phantom material displaced by the chamber. the magnitude of this correction must dep...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594817

    authors: Cunningham JR,Sontag MR

    更新日期:1980-11-01 00:00:00

  • Diffuse-diffuse photon coupling via nonscattering void in the presence of refractive index mismatch on the void boundary.

    abstract::It is well established that the diffusion approximation (DA) is valid for light propagation in highly scattering media, but it breaks down in nonscattering void regions. The methods that handle the void with refractive index matched boundary were previously developed. For the void with refractive index mismatched boun...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1766418

    authors: Lee JH,Kim S,Kim YT

    更新日期:2004-08-01 00:00:00

  • SU-E-T-424: Inter-Fraction Variation of High Dose Regions of OARS in MR Image Based Cervix Brachytherapy Using Rigid Registration.

    abstract:PURPOSE:To quantify the inter fraction variation of spatial location of high dose regions of OARs in MR-image based cervix brachytherapy using rigid registration algorithm. METHODS:Retrospective analysis of 27 previously treated patients under EMBRACE multi-centric trial was evaluated. Each patient had two application...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735513

    authors: Swamidas J,Mahantshetty U,Deshpande D,Shrivastava S

    更新日期:2012-06-01 00:00:00

  • Spacing nomograph for interstitial implants of 125I seeds.

    abstract::Permanent implants of 125I seeds at Memorial Sloan-Kettering Cancer Center are performed by the method of "dimension averaging" to determine the total activity to be implanted; that is, the activity (in mCi) is taken to be five times the average dimension (in cm) of the target region. A nomograph has recently been dev...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594269

    authors: Anderson LL

    更新日期:1976-01-01 00:00:00

  • Poster - Thurs Eve-04: Mathematical modeling of liver metastases tumour growth and control with radiotherapy.

    abstract::Generating an optimized radiation treatment plan requires understanding the factors affecting tumour control. Mathematical models of tumour dynamics may help in future studies of factors predicting tumor sensitivity to radiotherapy. In this study, a time-dependent differential model, incorporating biological cancer ma...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2965923

    authors: Campbell A,Davidson M,Lock M,Wong E

    更新日期:2008-07-01 00:00:00

  • Novel methods of measuring single scan dose profiles and cumulative dose in CT.

    abstract::Computed tomography dose index (CTDI) is a conventional indicator of the patient dose in CT studies. It is measured as the integration of the longitudinal single scan dose profile (SSDP) by using a 100-mm-long pencil ionization chamber and a single axial scan. However, the assumption that most of the SSDP is contained...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1835571

    authors: Nakonechny KD,Fallone BG,Rathee S

    更新日期:2005-01-01 00:00:00

  • Dynamic multiatlas selection-based consensus segmentation of head and neck structures from CT images.

    abstract:PURPOSE:Manual delineation of head and neck (H&N) organ-at-risk (OAR) structures for radiation therapy planning is time consuming and highly variable. Therefore, we developed a dynamic multiatlas selection-based approach for fast and reproducible segmentation. METHODS:Our approach dynamically selects and weights the a...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13854

    authors: Haq R,Berry SL,Deasy JO,Hunt M,Veeraraghavan H

    更新日期:2019-12-01 00:00:00

  • Daily check instrument for photon and electron beam quality assurance of medical linacs.

    abstract::An instrument for daily beam checks of medical accelerators is described. Using three silicon diodes, the instrument provides information about calibration, beam symmetry, flatness, and energy variation for both photon and electron beams. Operating characteristics of the instrument and the electronic circuit design pe...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595756

    authors: Lutz WR,Maddox BJ,Kase KR

    更新日期:1985-07-01 00:00:00

  • The generalized geometry of eye plaque therapy.

    abstract::A calculation is described that enables the rapid assessment of dose rate at various points of interest within the eye (lens, optic nerve, etc.) for the treatment of choroidal melanoma by plaque therapy. 125I seeds are used as the radiation source. The location of the plaque and its associated seeds relative to the ey...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596234

    authors: Kepka AG,Johnson PM,Kline RW

    更新日期:1988-05-01 00:00:00

  • WE-G-217BCD-10: Shading Correction in Image Domain for Cone-Beam CT Without Prior Information.

    abstract:PURPOSE:Cone-beam CT (CBCT) images contain severe shading artifacts mostly due to scatter. Many algorithms have been proposed to alleviate this problem by data correction on projections. Sophisticated methods have also been designed to further improve the image quality when prior patient information is available. In th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4736218

    authors: Fan Q,Niu T,Zhu L

    更新日期:2012-06-01 00:00:00

  • Explicit optimization of plan quality measures in intensity-modulated radiation therapy treatment planning.

    abstract:PURPOSE:To formulate convex planning objectives of treatment plan multicriteria optimization with explicit relationships to the dose-volume histogram (DVH) statistics used in plan quality evaluation. METHODS:Conventional planning objectives are designed to minimize the violation of DVH statistics thresholds using pena...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12146

    authors: Engberg L,Forsgren A,Eriksson K,Hårdemark B

    更新日期:2017-06-01 00:00:00

  • A two-step algorithm for predicting portal dose images in arbitrary detectors.

    abstract::Recently, portal imaging systems have been successfully demonstrated in dosimetric treatment verification applications, where measured and predicted images are quantitatively compared. To advance this approach to dosimetric verification, a two-step model which predicts dose deposition in arbitrary portal image detecto...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1289375

    authors: McCurdy BM,Pistorius S

    更新日期:2000-09-01 00:00:00

  • Theoretical study of temperature elevation at muscle/bone interface during ultrasound hyperthermia.

    abstract::This paper examines the distributions of the SAR (specific absorption rate) ratio and temperature elevation when an ultrasound beam propagates through the interface of muscle and bone. This interface is regarded as a flat boundary to partition the energy of the ultrasound beam, and the analytical solution of temperatu...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598979

    authors: Lin WL,Liauh CT,Chen YY,Liu HC,Shieh MJ

    更新日期:2000-05-01 00:00:00

  • Scatter-glare correction using a convolution algorithm with variable weighting.

    abstract::Several investigators have approximated the scatter component of digital radiographic images by applying a constant weighting factor to a convolved version of the detected image. The scatter approximation is then subtracted from the detected image. When a constant weighting factor is used, the scatter in areas of low ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596088

    authors: Naimuddin S,Hasegawa B,Mistretta CA

    更新日期:1987-05-01 00:00:00

  • Robotic intrafractional US guidance for liver SABR: System design, beam avoidance, and clinical imaging.

    abstract:PURPOSE:To present a system for robotic 4D ultrasound (US) imaging concurrent with radiotherapy beam delivery and estimate the proportion of liver stereotactic ablative body radiotherapy (SABR) cases in which robotic US image guidance can be deployed without interfering with clinically used VMAT beam configurations. M...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4964454

    authors: Schlosser J,Gong RH,Bruder R,Schweikard A,Jang S,Henrie J,Kamaya A,Koong A,Chang DT,Hristov D

    更新日期:2016-11-01 00:00:00

  • A novel PET tumor delineation method based on adaptive region-growing and dual-front active contours.

    abstract::To more accurately and precisely delineate a tumor in a 3D PET image, we proposed a novel, semi-automatic, two-stage method by utilizing an adaptive region-growing algorithm and a dual-front active contour model. First, a rough region of interest (ROI) is manually drawn by a radiation oncologist that encloses a tumor....

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2956713

    authors: Li H,Thorstad WL,Biehl KJ,Laforest R,Su Y,Shoghi KI,Donnelly ED,Low DA,Lu W

    更新日期:2008-08-01 00:00:00

  • A simple test phantom for stereotactic computed tomography.

    abstract::An easy-to-use phantom has been constructed for checking the accuracy of a stereotactic computed tomography localization system. This phantom has been used on a commercially available stereotactic radiosurgery system. With this system, the phantom reference point, whose location is established by means of a precision ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597034

    authors: Ekstrand KE,Olds WW,Branch CL

    更新日期:1993-03-01 00:00:00

  • A moving slanted-edge method to measure the temporal modulation transfer function of fluoroscopic systems.

    abstract::Lag in fluoroscopic systems introduces a frame-averaging effect that reduces measurements of image noise and incorrectly inflates measurements of the detective quantum efficiency (DQE). A correction can be implemented based on measurements of the temporal modulation transfer function (MTF). We introduce a method of me...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2919724

    authors: Friedman SN,Cunningham IA

    更新日期:2008-06-01 00:00:00

  • Fast iterative algorithms for three-dimensional inverse treatment planning.

    abstract::Three types of iterative algorithms, algebraic inverse treatment planning (AITP), simultaneous iterative inverse treatment planning (SIITP), and iterative least-square inverse treatment planning (ILSITP), differentiated according to their updating sequences, were generalized to three dimension with true beam geometry ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598374

    authors: Xing L,Hamilton RJ,Spelbring D,Pelizzari CA,Chen GT,Boyer AL

    更新日期:1998-10-01 00:00:00

  • Validation of deformable registration in head and neck cancer using analysis of variance.

    abstract:PURPOSE:Deformable image registration (DIR) is often validated based on a distance-to-agreement (DTA) criterion of automatically propagated anatomical landmarks that were manually identified. Due to human observer variability, however, the performance of the registration method is diluted. The purpose of this study was...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4760990

    authors: Mencarelli A,van Beek S,van Kranen S,Rasch C,van Herk M,Sonke JJ

    更新日期:2012-11-01 00:00:00

  • Evaluation of a deep learning-based computer-aided diagnosis system for distinguishing benign from malignant thyroid nodules in ultrasound images.

    abstract:PURPOSE:Computer-aided diagnosis (CAD) systems assist in solving subjective diagnosis problems that typically rely on personal experience. A CAD system has been developed to differentiate malignant thyroid nodules from benign thyroid nodules in ultrasound images based on deep learning methods. The diagnostic performanc...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14301

    authors: Sun C,Zhang Y,Chang Q,Liu T,Zhang S,Wang X,Guo Q,Yao J,Sun W,Niu L

    更新日期:2020-09-01 00:00:00

  • Technical note: the calibration of 90Y-labeled SIR-Spheres using a nondestructive spectroscopic assay.

    abstract::90Y-labeled SIR-Spheres are currently used to treat patients with hepatic metastases secondary to colorectal adenocarcinoma. In general, the prescribed activity is based on empirical data collected during clinical trials. The activity of the source vial is labeled by the manufacturer as 3.0 GBq +/- 10% and is not inde...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2889621

    authors: Selwyn R,Micka J,DeWerd L,Nickles R,Thomadsen B

    更新日期:2008-04-01 00:00:00