Poster - Thur Eve - 04: Online review of beam output and profile constancy using statistical process control.

Abstract:

:The objective of this work was to create a comprehensive online tool to evaluate and review the performance of quality assurance measurements that assess beam output and profile constancy as soon as they are acquired using statistical process control. As part of routine quality assurance: output, flatness and symmetry measurements are acquired daily and weekly with DQA3 and the Matrix and symmetry and flatness are acquired on a monthly basis with Profiler2. An individuals control chart and a moving range control chart was plotted for each set of data. Upper and lower control limits were calculated using measurements acquired during a several month period when the linear accelerators were operating optimally. The existing action levels, established according to TG142 and CAPCA guidelines were compared with the calculated statistical control limits. Tighter tolerance limits were recommended for output, symmetry and flatness Matrix measurements and DQA3 flatness measurements.

journal_name

Med Phys

journal_title

Medical physics

authors

Chmielewski R,Abbas A,Yeung I

doi

10.1118/1.4740111

subject

Has Abstract

pub_date

2012-07-01 00:00:00

pages

4624-4625

issue

7Part2

eissn

0094-2405

issn

2473-4209

journal_volume

39

pub_type

杂志文章
  • SU-E-T-162: Rapid Assessment of Cyberknife IRIS Variable Collimator Performance Using a Commercial Diode Array.

    abstract:PURPOSE:To describe an efficient method for verifying the size and centering of the radiation field from the Cyberknife IRIS variable collimator with sub-millimeter accuracy using a general purpose commercially available diode array. METHODS:We present a technique using a conventional diode array (Sun Nuclear Profiler...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735220

    authors: Gibbs G,White G,Bulz G

    更新日期:2012-06-01 00:00:00

  • Estimated spectrum of a 4-MV therapeutic beam.

    abstract::We have made a comparative investigation of the estimated spectra obtained by the Laplace transform analysis of the transmitted exposure data measured in an absorption study of a 4-MV x-ray beam. Four transform pair models currently used with this method have been evaluated. It has been determined that the Archer-Wagn...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595878

    authors: Ahuja SD,Steward PG,Roy TS,Slessinger ED

    更新日期:1986-05-01 00:00:00

  • A new method to combine 3D reconstruction volumes for multiple parallel circular cone beam orbits.

    abstract:PURPOSE:This article presents a new reconstruction method for 3D imaging using a multiple 360 degrees circular orbit cone beam CT system, specifically a way to combine 3D volumes reconstructed with each orbit. The main goal is to improve the noise performance in the combined image while avoiding cone beam artifacts. M...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3484058

    authors: Baek J,Pelc NJ

    更新日期:2010-10-01 00:00:00

  • Combined kV and MV imaging for real-time tracking of implanted fiducial markers.

    abstract::In the presence of intrafraction organ motion, target localization uncertainty can greatly hamper the advantage of highly conformal dose techniques such as intensity modulated radiation therapy (IMRT). To minimize the adverse dosimetric effect caused by tumor motion, a real-time knowledge of the tumor position is requ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2842072

    authors: Wiersma RD,Mao W,Xing L

    更新日期:2008-04-01 00:00:00

  • Technical Note: Experimental determination of the effective point of measurement of two cylindrical ionization chambers in a clinical proton beam.

    abstract:PURPOSE:IAEA TRS-398 notes that cylindrical ionization chambers are preferred for reference proton dosimetry. If a cylindrical ionization chamber is used in a phantom to measure the dose as a function of depth, the effective point of measurement (EPOM) must be taken into account. IAEA TRS-398 recommends a displacement ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4921617

    authors: Sugama Y,Nishio T,Onishi H

    更新日期:2015-07-01 00:00:00

  • Irradiation of gold nanoparticles by x-rays: Monte Carlo simulation of dose enhancements and the spatial properties of the secondary electrons production.

    abstract:PURPOSE:The aim of this study is to understand the characteristics of secondary electrons generated from the interaction of gold nanoparticles (GNPs) with x-rays as a function of nanoparticle size and beam energy and thereby further the understanding of GNP-enhanced radiotherapy. METHODS:The effective range, deflectio...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3539623

    authors: Leung MK,Chow JC,Chithrani BD,Lee MJ,Oms B,Jaffray DA

    更新日期:2011-02-01 00:00:00

  • A mobile isocentric C-arm for intraoperative cone-beam CT: Technical assessment of dose and 3D imaging performance.

    abstract:PURPOSE:To characterize the radiation dose and three-dimensional (3D) imaging performance of a recently developed mobile, isocentric C-arm equipped with a flat-panel detector (FPD) for intraoperative cone-beam computed tomography (CBCT) (Cios Spin 3D, Siemens Healthineers) and to identify potential improvements in 3D i...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13983

    authors: Sheth NM,De Silva T,Uneri A,Ketcha M,Han R,Vijayan R,Osgood GM,Siewerdsen JH

    更新日期:2020-03-01 00:00:00

  • Verification of treatment parameter transfer by means of electronic portal dosimetry.

    abstract::Electronic portal imaging devices (EPIDs) are mainly used for patient setup verification during treatment but other geometric properties like block shape and leaf positions are also determined. Electronic portal dosimetry allows dosimetric treatment verification. By combining geometric and dosimetric information, the ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1640972

    authors: Nijsten SM,Minken AW,Lambin P,Bruinvis IA

    更新日期:2004-02-01 00:00:00

  • Technical Note: Correction for intra-chamber dose gradients in reference dosimetry of flattening-filter-free MV photon beams.

    abstract:PURPOSE:To estimate and correct for the volume averaging effect which results from the intra-chamber dose gradients when a Farmer ionization chamber (IC) is used for reference dosimetry in flattening-filter-free (FFF) MV photon beams. METHODS:An intra-chamber dose gradients correction factor (kicdg) to the charge read...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4958960

    authors: Ruggieri R,Naccarato S,Stavrev P,Stavreva N,Pasetto S,Salamone I,Alongi F

    更新日期:2016-08-01 00:00:00

  • Accuracy of Dose-Volume Metric Calculation for Small Volume Radiosurgery Targets.

    abstract:PURPOSE:For stereotactic radiosurgery (SRS), accurate evaluation of dose-volume metrics for small structures is necessary. The purpose of this study was to compare the DVH metric capabilities of five commercially available SRS DVH analysis tools (Eclipse, Elements, Raystation, MIM, and Velocity). METHODS:DICOM RTdose ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14645

    authors: Stanley DN,Covington E,Liu H,Alexandrian A,Cardan R,Bridges D,Thomas EM,Fiveash JB,Popple R

    更新日期:2020-12-09 00:00:00

  • A simple model for examining issues in radiotherapy optimization.

    abstract::Convolution/superposition software has been used to produce a library of photon pencil beam dose matrices. This library of pencil beams is designed to serve as a tool for both education and investigation in the field of radiotherapy optimization. The elegance of this pencil beam model stems from its cylindrical symmet...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598615

    authors: Shepard DM,Olivera G,Angelos L,Sauer O,Reckwerdt P,Mackie TR

    更新日期:1999-07-01 00:00:00

  • Target motion measurement without implanted markers and its validation by comparison with manually obtained data.

    abstract::For an effective radiotherapy the exact tumor location must be determined. The localization has to take into account patient's setup position as well as internal organ motion. Among the different localization methods, the use of a computer tomography (CT) scanner in the therapy room has been proposed recently. Achievi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2103447

    authors: Vences L,Wulf J,Vordermark D,Sauer O,Berlinger K,Roth M

    更新日期:2005-11-01 00:00:00

  • Registration of clinical volumes to beams-eye-view images for real-time tracking.

    abstract:PURPOSE:The authors combine the registration of 2D beam's eye view (BEV) images and 3D planning computed tomography (CT) images, with relative, markerless tumor tracking to provide automatic absolute tracking of physician defined volumes such as the gross tumor volume (GTV). METHODS:During treatment of lung SBRT cases...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4900603

    authors: Bryant JH,Rottmann J,Lewis JH,Mishra P,Keall PJ,Berbeco RI

    更新日期:2014-12-01 00:00:00

  • Determination of the half-life of I-125 encapsulated clinical seeds using a Si(Li) detector.

    abstract::The half-life of two I-125 encapsulated clinical seeds was measured with a Si(Li) semiconductor detector. Two measurements of each seed yielded an average half-life of 59.56 +/- 0.17 days. The results are discussed in terms of the influence of possible I-126 contamination and leakage of I-125 activity through encapsul...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595423

    authors: Kubo H

    更新日期:1983-11-01 00:00:00

  • Tree structured wavelet transform segmentation of microcalcifications in digital mammography.

    abstract::A novel multistage algorithm is proposed for the automatic segmentation of microcalcification clusters (MCCs) in digital mammography. First, a previously reported tree structured nonlinear filter is proposed for suppressing image noise, while preserving image details, to potentially reduce the false positive (FP) dete...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597562

    authors: Qian W,Kallergi M,Clarke LP,Li HD,Venugopal P,Song D,Clark RA

    更新日期:1995-08-01 00:00:00

  • Calculating output factors for photon beam radiotherapy using a convolution/superposition method based on a dual source photon beam model.

    abstract::A realistic photon beam model based on Monte Carlo simulation of clinical linear accelerators was implemented in a convolution/superposition dose calculation algorithm. A primary and an extra-focal sources were used in this beam model to represent the direct photons from the target and the scattered photons from other...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598111

    authors: Liu HH,Mackie TR,McCullough EC

    更新日期:1997-12-01 00:00:00

  • Validation and application of a fast Monte Carlo algorithm for assessing the clinical impact of approximations in analytical dose calculations for pencil beam scanning proton therapy.

    abstract:PURPOSE:Monte Carlo (MC) dose calculation is generally superior to analytical dose calculation (ADC) used in commercial TPS to model the dose distribution especially for heterogeneous sites, such as lung and head/neck patients. The purpose of this study was to provide a validated, fast, and open-source MC code, MCsquar...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13231

    authors: Huang S,Souris K,Li S,Kang M,Barragan Montero AM,Janssens G,Lin A,Garver E,Ainsley C,Taylor P,Xiao Y,Lin L

    更新日期:2018-12-01 00:00:00

  • Reduction of ring artifacts in CBCT: detection and correction of pixel gain variations in flat panel detectors.

    abstract:PURPOSE:In using flat panel detectors (FPD) for cone beam computed tomography (CBCT), pixel gain variations may lead to structured nonuniformities in projections and ring artifacts in CBCT images. Such gain variations can be caused by change in detector entrance exposure levels or beam hardening, and they are not accou...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4893278

    authors: Altunbas C,Lai CJ,Zhong Y,Shaw CC

    更新日期:2014-09-01 00:00:00

  • Iodine kinetics and dosimetry in the salivary glands during repeated courses of radioiodine therapy for thyroid cancer.

    abstract:PURPOSE:The present study was conducted to investigate salivary iodine kinetics and dosimetry during repeated courses of radioiodine ((131)I) therapy for differentiated thyroid cancer (DTC). Such data could provide a better understanding of the mechanisms of (131)I induced salivary toxicity and help to develop appropri...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3602459

    authors: Liu B,Huang R,Kuang A,Zhao Z,Zeng Y,Wang J,Tian R

    更新日期:2011-10-01 00:00:00

  • A method for reducing motion induced errors in T2-weighted magnetic resonance imaging.

    abstract::It is known that motion of an object imaged by magnetic resonance imaging leads to errors and artifacts in the image. This effect is especially important when a pulse sequence with long echo time (TE) and long TR is used to provide T2-weighted images. We have modified the usual spin warp imaging pulse sequence in a wa...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596026

    authors: Joseph PM,Shetty A,Bonaroti EA

    更新日期:1987-07-01 00:00:00

  • Ultrasonic Nakagami-parameter characterization of parotid-gland injury following head-and-neck radiotherapy: a feasibility study of late toxicity.

    abstract:PURPOSE:The study aims to investigate whether Nakagami parameters--estimated from the statistical distribution of the backscattered ultrasound radio-frequency (RF) signals--could provide a means for quantitative characterization of parotid-gland injury resulting from head-and-neck radiotherapy. METHODS:A preliminary c...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4862507

    authors: Yang X,Tridandapani S,Beitler JJ,Yu DS,Wu N,Wang Y,Bruner DW,Curran WJ,Liu T

    更新日期:2014-02-01 00:00:00

  • Convolutional neural network-based dosimetry evaluation of esophageal radiation treatment planning.

    abstract:PURPOSE:A dosimetry evaluation model for treatment planning of esophageal radiation therapy is developed using a deep learning model. The model predicts dose volume histogram (DVH) from distance to target histogram (DTH) based on stacked de-noise auto-encoder (SDAE) and one-dimensional convolutional network (1D-CN). M...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14434

    authors: Jiang D,Yan H,Chang N,Li T,Mao R,Du C,Guo B,Liu J

    更新日期:2020-10-01 00:00:00

  • Technical Note: Impact of region of interest size and location in Gafchromic film dosimetry.

    abstract:PURPOSE:To evaluate dependence of measured dose on size and location of region of interest (ROI) in Gafchromic EBT3 film dosimetry. METHODS:Gafchromic EBT3 films were irradiated perpendicularly using the 6MV beam from a linear accelerator at 10 cm depth (100 cm SSD) of a 30 × 30 × 20 cm3 solid water phantom for a rang...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12885

    authors: Gholizadeh Sendani N,Karimian A,Ferreira C,Alaei P

    更新日期:2018-05-01 00:00:00

  • Evaluation of a deep learning-based computer-aided diagnosis system for distinguishing benign from malignant thyroid nodules in ultrasound images.

    abstract:PURPOSE:Computer-aided diagnosis (CAD) systems assist in solving subjective diagnosis problems that typically rely on personal experience. A CAD system has been developed to differentiate malignant thyroid nodules from benign thyroid nodules in ultrasound images based on deep learning methods. The diagnostic performanc...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14301

    authors: Sun C,Zhang Y,Chang Q,Liu T,Zhang S,Wang X,Guo Q,Yao J,Sun W,Niu L

    更新日期:2020-09-01 00:00:00

  • Noise power spectra of images from digital mammography detectors.

    abstract::Noise characterization through estimation of the noise power spectrum (NPS) is a central component of the evaluation of digital x-ray systems. We begin with a brief review of the fundamentals of NPS theory and measurement, derive explicit expressions for calculation of the one- and two-dimensional (1D and 2D) NPS, and...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598623

    authors: Williams MB,Mangiafico PA,Simoni PU

    更新日期:1999-07-01 00:00:00

  • Determination of the initial beam parameters in Monte Carlo linac simulation.

    abstract::For Monte Carlo linac simulations and patient dose calculations, it is important to accurately determine the phase space parameters of the initial electron beam incident on the target. These parameters, such as mean energy and radial intensity distribution, have traditionally been determined by matching the calculated...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2168433

    authors: Aljarrah K,Sharp GC,Neicu T,Jiang SB

    更新日期:2006-04-01 00:00:00

  • Determination of the quality index (Q) for photon beams at arbitrary field sizes.

    abstract:PURPOSE:A commonly used beam quality index (Q) for high-energy photon beams is the tissue phantom ratio (TPR20,10) for a square field of 10 x 10 cm2 and SDD of 100 cm. On some specialized radiotherapy treatment equipment such a reference collimator setting is not achievable. Likewise a flat beam profile, not explicitly...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3197062

    authors: Sauer OA

    更新日期:2009-09-01 00:00:00

  • Dosimetry study of Re-188 liquid balloon for intravascular brachytherapy using polymer gel dosimeters and laser-beam optical CT scanner.

    abstract::Angioplasty balloons inflated with a solution of the beta-emitter Re-188 have been used for intravascular brachytherapy to prevent restenosis. Coronary stents are in extensive clinical use for the treatment of de novo atherosclerotic stenoses. In this study, the effect of an interposed stent on the dose distribution h...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1533749

    authors: Wuu CS,Schiff P,Maryanski MJ,Liu T,Borzillary S,Weinberger J

    更新日期:2003-02-01 00:00:00

  • Performance characterization of an integrated cone-beam CT system for dedicated gamma radiosurgery.

    abstract:PURPOSE:This work describes the performance characterization of a cone-beam CT-guided radiosurgery device, the Gamma Knife® Icon™. METHODS:The performance tests have been categorized into: (a) image quality and mechanical integrity; (b) image coregistration fidelity; (c) adaptive treatment delivery quality; (d) high d...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13073

    authors: Sarfehnia A,Ruschin M,Chugh B,Yeboah C,Becker N,Cho YB,Lee Y

    更新日期:2018-06-29 00:00:00

  • Unwanted radiation produced by leakage neutrons from medical electron accelerators.

    abstract::Monte Carlo calculations have been made to determine the energy delivered to a phantom by neutrons escaping from the head of a Varian Clinac 35 medical accelerator at an SSD of 1 m. The energy was sorted into two regions: inside and outside a volume defined by a circular beam of area 100 and 600 cm2. For the two beam ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595067

    authors: Ing H,Shore RA

    更新日期:1982-01-01 00:00:00