Abstract:
:A realistic photon beam model based on Monte Carlo simulation of clinical linear accelerators was implemented in a convolution/superposition dose calculation algorithm. A primary and an extra-focal sources were used in this beam model to represent the direct photons from the target and the scattered photons from other head structures, respectively. The effect of the finite size of the extra-focal source was modeled by a convolution of the source fluence distribution with the collimator aperture function. Relative photon output in air (Sc) and in phantom (Scp) were computed using the convolution method with this new photon beam model. Our results showed that in a 10 MV photon beam, the Sc, Sp (phantom scatter factor), and Scp factors increased by 11%, 10%, and 22%, respectively, as the field size changed from 3 x 3 cm2 to 40 x 40 cm2. The variation of the Sc factor was contributed mostly by an increase of the extra-focal radiation with field size. The radiation backscattered into the monitor chamber inside the accelerator head affected the Sc by about 2% in the same field range. The output factors in elongated fields, asymmetric fields, and blocked fields were also investigated in this study. Our results showed that if the effect of the backscattered radiation was taken into account, output factors in these treatment fields can be predicted accurately by our convolution algorithm using the dual source photon beam model.
journal_name
Med Physjournal_title
Medical physicsauthors
Liu HH,Mackie TR,McCullough ECdoi
10.1118/1.598111subject
Has Abstractpub_date
1997-12-01 00:00:00pages
1975-85issue
12eissn
0094-2405issn
2473-4209journal_volume
24pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract:PURPOSE:Computational models are widely used during the design and characterization of microwave ablation (MWA) devices, and have been proposed for pretreatment planning. Our objective was to assess three-dimensional (3D) transient temperature and ablation profiles predicted by MWA computational models with temperature...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14318
更新日期:2020-09-01 00:00:00
abstract::The radiation dose to the lungs from 133Xe in lung air is directly proportional to the time integral of 133Xe concentration; i.e., the cumulated concentration in the lungs. Using kinetic models developed to fit clinical observations, we have studied the effect of retention on cumulated concentration in lung air. The m...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594341
更新日期:1977-11-01 00:00:00
abstract:PURPOSE:Compton camera imaging (CCI) systems are currently under investigation for radiotherapy dose reconstruction and verification. The ability of such a system to provide real-time images during dose delivery will be limited by the computational speed of the image reconstruction algorithm. In this work, the authors ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3519873
更新日期:2011-01-01 00:00:00
abstract::The half-life of two I-125 encapsulated clinical seeds was measured with a Si(Li) semiconductor detector. Two measurements of each seed yielded an average half-life of 59.56 +/- 0.17 days. The results are discussed in terms of the influence of possible I-126 contamination and leakage of I-125 activity through encapsul...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595423
更新日期:1983-11-01 00:00:00
abstract:PURPOSE:To evaluate the patient positioning accuracy and reproducibility of two commercially available immobilization systems for Stereotactic Body Radiotherapy (SBRT) treatment. METHODS:Forty one patients with lung (n=21) or liver (n=20) malignancies were assigned to one of the two immobilization devices: Elekta ster...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735009
更新日期:2012-06-01 00:00:00
abstract::The main purpose of this work is to demonstrate a practical means of determining the leaf transmission and scatter characteristics of a multileaf collimator (MLC) pertinent to the commissioning of dynamic intensity modulated radiotherapy, especially for the sweeping window technique. The data are necessary for the con...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1312190
更新日期:2000-10-01 00:00:00
abstract::Model-based deformable organ registration techniques using the finite element method (FEM) have recently been investigated intensively and applied to image-guided adaptive radiotherapy (IGART). These techniques assume that human organs are linearly elastic material, and their mechanical properties are predetermined. U...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2163838
更新日期:2006-02-01 00:00:00
abstract::Calibration of an imported strontium-90 ophthalmic applicator at the U.S. National Bureau of Standards (now the National Institute of Standards and Technology) has disclose a significant discrepancy in dose rate calibration (32%-35%) with that quoted by the manufacturer. The University of Wisconsin has investigated th...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596702
更新日期:1991-03-01 00:00:00
abstract::The implementation of an improved model for multiple scattering into the-Voxel Monte Carlo (VMC) algorithm for fast electron dose calculation in radiation therapy is presented. The model takes into account path-length corrections (PLC) and lateral displacement in the individual electron steps. The extraction of the sc...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597933
更新日期:1997-04-01 00:00:00
abstract:PURPOSE:The goal of this work is to propose a new multichannel method correcting for systematic thickness disturbances and to evaluate its precision in relevant radiation dosimetry applications. METHODS:The eigencolor ratio technique is introduced and theoretically developed to provide a method correcting for thicknes...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14742
更新日期:2021-02-01 00:00:00
abstract:PURPOSE:Real-time tumor position/shape measurement and dynamic beam tracking techniques allow accurate and continuous irradiation to moving tumor, but there can be a delay of several hundred milliseconds between observation and irradiation. A time-variant seasonal autoregressive (TVSAR) model has been proposed for comp...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4734680
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:To provide an overview of the types of adverse events reported to the US Food and Drug Administration (US FDA) for magnetic resonance (MR) systems over a 10-yr period. METHODS:Two reviewers independently reviewed adverse events reported to FDA for MR systems from 1 January 2008 to 31 December 2017 and manually...
journal_title:Medical physics
pub_type: 杂志文章,评审
doi:10.1002/mp.13768
更新日期:2019-12-01 00:00:00
abstract::The feasibility of using film dosimetry data as the input data for patient treatment planning was evaluated. The central-axis depth dose and the off-axis ratios obtained from film measurements in a solid phantom were compared with those of ion-chamber measurements in water. Two techniques were used to generate isodose...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596409
更新日期:1989-11-01 00:00:00
abstract:PURPOSE:To generate hybrid VMAT-IMRT treatment plans by utilizing an IMRT beam-angle-optimality (BAO) search under a commercially available TPS without the aid of custom optimization software or high performance computing. METHODS:The high dose modulation provided by IMRT beams can be exploited to improve the quality ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735712
更新日期:2012-06-01 00:00:00
abstract::In computer simulations of x-ray CT systems one can either use continuous geometrical descriptions for phantoms or a voxelized representation. The voxelized approach allows arbitrary phantoms to be defined without being confined to geometrical shapes. The disadvantage of the voxelized approach is that inherent errors ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1461841
更新日期:2002-04-01 00:00:00
abstract::In a practical classifier design problem, the true population is generally unknown and the available sample is finite-sized. A common approach is to use a resampling technique to estimate the performance of the classifier that will be trained with the available sample. We conducted a Monte Carlo simulation study to co...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2868757
更新日期:2008-04-01 00:00:00
abstract::The dose-rate dependence of commercially available diode detectors was measured under both high instantaneous dose-rate (pulsed) and low dose rate (continuous, Co-60) radiation. The dose-rate dependence was measured in an acrylic miniphantom at a 5-cm depth in a 10 x 10 cm2 collimator setting, by varying source-to-det...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1650563
更新日期:2004-04-01 00:00:00
abstract::The photon energy spectrum emanating from a Leksell Gamma Knife, Model 23004B, was measured between 0.250 and 3.5 MeV with the sources exposed. Measurements were made using a 2x2 inch NaI detector enclosed in a lead-shielded apparatus having a 1/4 inch diameter measurement aperture, which reduced the amount of radiati...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1355305
更新日期:2001-04-01 00:00:00
abstract:PURPOSE:Current on-board imaging systems commonly used by modern linear accelerators (LINACs) have a limited field of view (FOV) for a cone-beam CT (CBCT) scan, which is typically less than 50 cm. Consequently, truncation artifacts often occur for large patients. The goal of this work is to investigate a novel method t...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3514130
更新日期:2010-12-01 00:00:00
abstract:PURPOSE:To introduce a novel laser-based optical-CT scanner for the readout of three-dimensional (3D) radiation dosimeters. METHODS:The scanner employs a diode laser, a cylindrical lens, a motorized linear rail, a rotation stage, and a charge-coupled device camera. The scanner operates in a translate-rotate fashion an...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3538924
更新日期:2011-02-01 00:00:00
abstract::In this report we describe an improvement upon the design by Stanton and Lightfoot for a simple photographic null method to determine the kVp of a diagnostic region x-ray source. The new version has two primary advantages over the Ardran and Crooks design in that it is both simpler and less expensive to produce. ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595716
更新日期:1985-03-01 00:00:00
abstract:PURPOSE:High-spatial-resolution x-ray imaging in the few-ten-keV range is becoming increasingly important in several applications, such as small-animal imaging and phase-contrast imaging. The detector properties critically influence the quality of such imaging. Here the authors present a quantitative comparison of scin...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4948687
更新日期:2016-06-01 00:00:00
abstract:PURPOSE:Real-time sub-millimeter head motion compensation during frameless SRS delivery has the potential to achieve the accuracy of frame-based SRS while being significantly less invasive. Previously, we demonstrated real-time 6D head motion monitoring using an optical camera, however, at the time we were limited to o...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4734995
更新日期:2012-06-01 00:00:00
abstract::In prostate seed implants, radioactive seeds are implanted into the prostate through a guiding needle with the help of a template and real-time imaging. The ideal locations of the guiding needles and the relative positions of the seeds in each needle are determined before the implantation under the assumption that the...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598971
更新日期:2000-05-01 00:00:00
abstract:PURPOSE:Intracavitary accelerated partial breast irradiation (APBI) has become a popular treatment for early stage breast cancer in recent years due to its shortened course of treatment and simplified treatment planning compared to traditional external beam breast conservation therapy. However, the exit dose to the ski...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3429089
更新日期:2010-06-01 00:00:00
abstract::Lag in fluoroscopic systems introduces a frame-averaging effect that reduces measurements of image noise and incorrectly inflates measurements of the detective quantum efficiency (DQE). A correction can be implemented based on measurements of the temporal modulation transfer function (MTF). We introduce a method of me...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2919724
更新日期:2008-06-01 00:00:00
abstract::The resolution has been evaluated for an experimental x-ray image intensifier employing three microchannel plates (MCPs) as the photon absorber and electron multipliers. The line spread function (LSF) was measured and used for determination of the modulation transfer function (MTF). The MTF was found to be independent...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594463
更新日期:1978-01-01 00:00:00
abstract::Myocardial beta adrenergic receptor (beta-AR) concentration can substantially decrease in congestive heart failure and significantly increase in chronic volume overload, such as in severe aortic valve regurgitation. Positron emission tomography (PET) with an appropriate ligand-receptor model can be used for noninvasiv...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2402585
更新日期:2007-01-01 00:00:00
abstract::A photon transport algorithm for fully three-dimensional radiotherapy treatment planning has been developed based on the discrete ordinates (SN) solution of the Boltzmann equation. The algorithm is characterized by orthogonal adaptive meshes, which place additional points where large gradients occur and a procedure to...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2960247
更新日期:2008-09-01 00:00:00
abstract:PURPOSE:Body composition is known to be associated with many diseases including diabetes, cancers, and cardiovascular diseases. In this paper, we developed a fully automatic body tissue decomposition procedure to segment three major compartments that are related to body composition analysis - subcutaneous adipose tissu...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14465
更新日期:2020-11-01 00:00:00