Technical Note: Impact of region of interest size and location in Gafchromic film dosimetry.

Abstract:

PURPOSE:To evaluate dependence of measured dose on size and location of region of interest (ROI) in Gafchromic EBT3 film dosimetry. METHODS:Gafchromic EBT3 films were irradiated perpendicularly using the 6MV beam from a linear accelerator at 10 cm depth (100 cm SSD) of a 30 × 30 × 20 cm3 solid water phantom for a range of field sizes of 6 × 6 to 100 × 100 mm2 . ImageJ software was used for reading pieces of film. The appropriate location of ROIs in scanned films was found by two methods. First, the ROI was visually placed at the center of image. Second, the profile of pixel value versus distance was plotted and the center of profile was used for drawing ROI. Each scanned film was read using both methods and for three ROI sizes (1, 2, and 4 mm). A plastic scintillator, Exradin W1, was used as the reference dosimeter. RESULTS:Comparing the three ROI sizes using both methods showed that there was less than 2% difference from reference in output factor measurements for field sizes larger or equal to 10 × 10 mm2 . The percentage differences were increased in field sizes smaller than 10 × 10 mm2 and for ROI size of 4 × 4 mm2 for both centered-ROI and profiled-ROI methods. The mean percentage differences from reference measurements, for field sizes of 100 × 100 to 20 × 20 mm2 , were smaller than 1% in both methods of ROI positioning. For field sizes of 15 × 15 and 10 × 10 mm2 , the smaller mean percentage differences were observed in profiled-ROI (4 × 4 mm2 ) and centered-ROI (4 × 4 mm2 ). For the field sizes of 8 × 8 and 6 × 6 mm2 , the profiled-ROI (2 × 2 mm2 ) had smallest mean percentage difference, which was 0.88%. CONCLUSION:The ROI size of 4 × 4 mm2 is appropriate for dose measurements in field sizes of 100 × 100 mm2 to 10 × 10 mm2 , regardless of the method of finding location of ROI. In field sizes smaller than 10 × 10 mm2 , finding location of the ROI by profile of pixel values increases the accuracy of measurement, and ROI size of 2 × 2 mm2 has the smallest difference from the reference dose measurements.

journal_name

Med Phys

journal_title

Medical physics

authors

Gholizadeh Sendani N,Karimian A,Ferreira C,Alaei P

doi

10.1002/mp.12885

subject

Has Abstract

pub_date

2018-05-01 00:00:00

pages

2329-2336

issue

5

eissn

0094-2405

issn

2473-4209

journal_volume

45

pub_type

杂志文章
  • Effect of patient support pads on image quality and dose in fluoroscopy.

    abstract::An investigation was performed of the changes in image quality and patient dose as a result of increasing filtration for fluoroscopy performed under automatic brightness control. Filtration was added either at the x-ray tube housing (i.e., scatter-free geometry) or adjacent to a tissue equivalent phantom simulating th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597906

    authors: Geiser WR,Huda W,Gkanatsios NA

    更新日期:1997-03-01 00:00:00

  • Anniversary paper: Role of medical physicists and the AAPM in improving geometric aspects of treatment accuracy and precision.

    abstract::The last 50 years have seen great advances in the accuracy of external beam radiation therapy. Geometrical uncertainties have been reduced from a centimeter or more in presimulation, skin-mark guided days to 1-2 mm in today's image-guided radiation therapy treatments. Medical physicists, with the support and guidance ...

    journal_title:Medical physics

    pub_type: 杂志文章,评审

    doi:10.1118/1.2836420

    authors: Yorke ED,Keall P,Verhaegen F

    更新日期:2008-03-01 00:00:00

  • Voxel clustering for quantifying PET-based treatment response assessment.

    abstract:PURPOSE:Imaging biomarkers are crucial in managing treatment options for cancer patients. They are extremely powerful tools since they allow personalized treatment assessment early during therapy by using repeated imaging to detect and quantify tumor response. Currently, treatment response assessment from consecutive i...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4764900

    authors: Schreibmann E,Waller AF,Crocker I,Curran W,Fox T

    更新日期:2013-01-01 00:00:00

  • The accuracy of SPECT brain activation images: propagation of registration errors.

    abstract::Functional single photon emission computed tomography (SPECT) images of brain activation are based on a comparison of base line and activation images. The correctness of the functional images depends, among other factors, on the accurate spatial registration (alignment) of the base line and activation image data. The ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597412

    authors: Sychra JJ,Pavel DG,Chen Y,Jani A

    更新日期:1994-10-01 00:00:00

  • Repeatability of SUV measurements in serial PET.

    abstract:PURPOSE:The standardized uptake value (SUV) is a quantitative measure of FDG tumor uptake frequently used as a tool to monitor therapeutic response. This study aims to (i) assess the reproducibility and uncertainty of SUV max and SUV mean, due to purely statistical, i.e., nonbiological, effects and (ii) to establish th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3578604

    authors: Schwartz J,Humm JL,Gonen M,Kalaigian H,Schoder H,Larson SM,Nehmeh SA

    更新日期:2011-05-01 00:00:00

  • Technical Note: Performance comparison of ultra-high-resolution scan modes of two clinical computed tomography systems.

    abstract:PURPOSE:Two ultra-high-resolution (UHR) computed tomography (CT) scanners are clinically available. One is achieved by a CT system with a 0.25 mm × 160 row detector (Detector-UHR), whereas the other is with a 0.6 mm × 32 row detector with in-plane comb filtering in a dual source CT (Comb-UHR). We compared radiation dos...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13949

    authors: Kawashima H,Ichikawa K,Takata T,Nagata H,Hoshika M,Akagi N

    更新日期:2020-02-01 00:00:00

  • Leakage and scatter radiation from a double scattering based proton beamline.

    abstract::Proton beams offer several advantages over conventional radiation techniques for treating cancer and other diseases. These advantages might be negated if the leakage and scatter radiation from the beamline and patient are too large. Although the leakage and scatter radiation for the double scattering proton beamlines ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2805086

    authors: Moyers MF,Benton ER,Ghebremedhin A,Coutrakon G

    更新日期:2008-01-01 00:00:00

  • Use of a constrained hierarchical optimization dataset enhances knowledge-based planning as a quality assurance tool for prostate bed irradiation.

    abstract:PURPOSE:To investigate whether building a knowledge-based planning (KBP) model with prostate bed plans constructed from constrained hierarchical optimization (CHO) would result in more efficient model construction with more consistent output than a model built using plans from a traditional, trial-and-error-based optim...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13163

    authors: Lin YH,Hong LX,Hunt MA,Berry SL

    更新日期:2018-10-01 00:00:00

  • Automated lung segmentation of diseased and artifact-corrupted magnetic resonance sections.

    abstract::Segmentation of the lungs within magnetic resonance (MR) scans is a necessary step in the computer-based analysis of thoracic MR images. This process is often confounded by image acquisition artifacts and disease-induced morphological deformation. We have developed an automated method for lung segmentation that is ins...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2214165

    authors: Sensakovic WF,Armato SG 3rd,Starkey A,Caligiuri P

    更新日期:2006-09-01 00:00:00

  • Dose buildup for obliquely incident photon beams.

    abstract::For obliquely incident photon beams, the buildup of dose with depth is markedly different from normally incident beams. However, relatively little data on this topic exists for high-energy photon beams of energy greater than 6 MV. Measurements of dose in the buildup region were made using a plane-parallel ionization c...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596055

    authors: Gerbi BJ,Meigooni AS,Khan FM

    更新日期:1987-05-01 00:00:00

  • A respiratory-gated treatment system for proton therapy.

    abstract::Proton therapy offers the potential for excellent dose conformity and reduction in integral dose. The superior dose distribution is, however, much more sensitive to changes in radiological depths along the beam path than for photon fields. Respiratory motion can cause such changes for treatments sites like lung, liver...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2756602

    authors: Lu HM,Brett R,Sharp G,Safai S,Jiang S,Flanz J,Kooy H

    更新日期:2007-08-01 00:00:00

  • Multiscale entropy of laser Doppler flowmetry signals in healthy human subjects.

    abstract:PURPOSE:The cardiovascular system (CVS) regulation can be studied from a central viewpoint, through heart rate variability (HRV) data, and from a peripheral viewpoint, through laser Doppler flowmetry (LDF) signals. Both the central and peripheral CVSs are regulated by several interacting mechanisms, each having its own...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3512796

    authors: Humeau A,Buard B,Mahé G,Rousseau D,Chapeau-Blondeau F,Abraham P

    更新日期:2010-12-01 00:00:00

  • Cascaded systems analysis of noise and detectability in dual-energy cone-beam CT.

    abstract:PURPOSE:Dual-energy computed tomography and dual-energy cone-beam computed tomography (DE-CBCT) are promising modalities for applications ranging from vascular to breast, renal, hepatic, and musculoskeletal imaging. Accordingly, the optimization of imaging techniques for such applications would benefit significantly fr...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4736420

    authors: Gang GJ,Zbijewski W,Webster Stayman J,Siewerdsen JH

    更新日期:2012-08-01 00:00:00

  • SU-E-T-217: Automated Data Mining of Lung SBRT Cases for Predicting Dosimetric Indices in Prospective Plans.

    abstract:PURPOSE:To develop an automated technique for evaluating lung stereotactic body radiotherapy (SBRT) plan quality and predicting achievable lung dose constraints. METHODS:We examined the workflow scripting capabilities of a radiation oncology software package (MIM Software Inc) for automatically generating mean dose gr...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735279

    authors: Atwood T,Xing L,Hristov D

    更新日期:2012-06-01 00:00:00

  • Technical Note: Cortical thickness and density estimation from clinical CT using a prior thickness-density relationship.

    abstract:PURPOSE:Cortical thickness and density are critical components in determining the strength of bony structures. Computed tomography (CT) is one possible modality for analyzing the cortex in 3D. In this paper, a model-based approach for measuring the cortical bone thickness and density from clinical CT images is proposed...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4944501

    authors: Humbert L,Hazrati Marangalou J,Del Río Barquero LM,van Lenthe GH,van Rietbergen B

    更新日期:2016-04-01 00:00:00

  • Combined kV and MV imaging for real-time tracking of implanted fiducial markers.

    abstract::In the presence of intrafraction organ motion, target localization uncertainty can greatly hamper the advantage of highly conformal dose techniques such as intensity modulated radiation therapy (IMRT). To minimize the adverse dosimetric effect caused by tumor motion, a real-time knowledge of the tumor position is requ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2842072

    authors: Wiersma RD,Mao W,Xing L

    更新日期:2008-04-01 00:00:00

  • Effect of respiratory gating on reducing lung motion artifacts in PET imaging of lung cancer.

    abstract::Positron emission tomography (PET) has shown an increase in both sensitivity and specificity over computed tomography (CT) in lung cancer. However, motion artifacts in the 18F fluorodioxydoglucose (FDG) PET images caused by respiration persists to be an important factor in degrading PET image quality and quantificatio...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1448824

    authors: Nehmeh SA,Erdi YE,Ling CC,Rosenzweig KE,Squire OD,Braban LE,Ford E,Sidhu K,Mageras GS,Larson SM,Humm JL

    更新日期:2002-03-01 00:00:00

  • Transrectal ultrasound based prostate volume determination: is the frustum algorithm more accurate than planimetry?

    abstract:PURPOSE:To compare reconstructed volumes calculated via planimetry and frustum algorithms in the context of stepped transrectal ultrasound (US) imaging, and to estimate the reconstruction error for prostate volumes. METHODS:Prostate contours for 40 permanent implant patients were delineated on magnetic resonance (MR) ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4789920

    authors: Liu D,Usmani N,Sloboda RS

    更新日期:2013-03-01 00:00:00

  • Balancing dose and image registration accuracy for cone beam tomosynthesis (CBTS) for breast patient setup.

    abstract:PURPOSE:To balance dose reduction and image registration accuracy in breast setup imaging. In particular, the authors demonstrate the relationship between scan angle and dose delivery for cone beam tomosynthesis (CBTS) when employed for setup verification of breast cancer patients with surgical clips. METHODS:The dose...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3464716

    authors: Winey BA,Zygmanski P,Cormack RA,Lyatskaya Y

    更新日期:2010-08-01 00:00:00

  • A localization algorithm and error analysis for stereo x-ray image guidance.

    abstract::Stereo x-ray radiography attracts increasing attention in major clinical applications. The purpose of this paper is to analyze the 3D localization error for breast biopsy procedures and provide guidelines for improving its accuracy. Our prototype is a CCD based digital stereo x-ray imaging system. The mathematical mod...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598953

    authors: Jiang H,Liu H,Wang G,Chen W,Fajardo LL

    更新日期:2000-05-01 00:00:00

  • Upgrade and benchmarking of a 4D treatment planning system for scanned ion beam therapy.

    abstract:PURPOSE:Upgrade and benchmarking of a research 4D treatment planning system (4DTPS) suitable for realistic patient treatment planning and treatment simulations taking into account specific requirements for scanned ion beam therapy, i.e., modeling of dose heterogeneities due to interplay effects and range changes caused...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4800802

    authors: Richter D,Schwarzkopf A,Trautmann J,Krämer M,Durante M,Jäkel O,Bert C

    更新日期:2013-05-01 00:00:00

  • X-ray scatter correction in breast tomosynthesis with a precomputed scatter map library.

    abstract:PURPOSE:To develop and evaluate the impact on lesion conspicuity of a software-based x-ray scatter correction algorithm for digital breast tomosynthesis (DBT) imaging into which a precomputed library of x-ray scatter maps is incorporated. METHODS:A previously developed model of compressed breast shapes undergoing mamm...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4866229

    authors: Feng SS,D'Orsi CJ,Newell MS,Seidel RL,Patel B,Sechopoulos I

    更新日期:2014-03-01 00:00:00

  • Detection and diagnosis of colitis on computed tomography using deep convolutional neural networks.

    abstract:PURPOSE:Colitis refers to inflammation of the inner lining of the colon that is frequently associated with infection and allergic reactions. In this paper, we propose deep convolutional neural networks methods for lesion-level colitis detection and a support vector machine (SVM) classifier for patient-level colitis dia...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12399

    authors: Liu J,Wang D,Lu L,Wei Z,Kim L,Turkbey EB,Sahiner B,Petrick NA,Summers RM

    更新日期:2017-09-01 00:00:00

  • In vitro in-stent restenoses evaluated by 3D ultrasound.

    abstract::The purpose of this study was to quantify in-stent restenoses with 3D B mode and power Doppler ultrasound (U.S.) imaging. In-stent restenoses were mimicked with vascular phantoms in which a nonferromagnetic prototype stent (Boston Scientific) and a ferromagnetic clinical stainless steel stent (Palmaz P295) were embedd...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3062944

    authors: Lécart M,Cardinal MH,Qin Z,Soulez G,Cloutier G

    更新日期:2009-02-01 00:00:00

  • Dosimetric characteristics of the Leipzig surface applicators used in the high dose rate brachy radiotherapy.

    abstract::The nucletron Leipzig applicator is designed for (HDR) 192Ir brachy radiotherapy of surface lesions. The dosimetric characteristics of this applicator were investigated using simulation method based on Monte Carlo N-particle (MCNP) code and phantom measurements. The simulation method was validated by comparing calcula...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1812609

    authors: Niu H,Hsi WC,Chu JC,Kirk MC,Kouwenhoven E

    更新日期:2004-12-01 00:00:00

  • Acuros CTS: A fast, linear Boltzmann transport equation solver for computed tomography scatter - Part I: Core algorithms and validation.

    abstract:PURPOSE:To describe Acuros® CTS, a new software tool for rapidly and accurately estimating scatter in x-ray projection images by deterministically solving the linear Boltzmann transport equation (LBTE). METHODS:The LBTE describes the behavior of particles as they interact with an object across spatial, energy, and dir...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12850

    authors: Maslowski A,Wang A,Sun M,Wareing T,Davis I,Star-Lack J

    更新日期:2018-05-01 00:00:00

  • Unwanted radiation produced by leakage neutrons from medical electron accelerators.

    abstract::Monte Carlo calculations have been made to determine the energy delivered to a phantom by neutrons escaping from the head of a Varian Clinac 35 medical accelerator at an SSD of 1 m. The energy was sorted into two regions: inside and outside a volume defined by a circular beam of area 100 and 600 cm2. For the two beam ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595067

    authors: Ing H,Shore RA

    更新日期:1982-01-01 00:00:00

  • Evaluating the impact of extended field-of-view CT reconstructions on CT values and dosimetric accuracy for radiation therapy.

    abstract:PURPOSE:Wide bore CT scanners use extended field-of-view (eFOV) reconstruction algorithms to attempt to recreate tissue truncated due to large patient habitus. Radiation therapy planning systems rely on accurate CT numbers in order to correctly plan and calculate radiation dose. This study looks at the impact of eFOV r...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13299

    authors: Cheung JP,Shugard E,Mistry N,Pouliot J,Chen J

    更新日期:2019-02-01 00:00:00

  • WE-E-213CD-03: Inverse-Consistent Symmetric Registration of Inner Colon Surfaces Derived from Prone and Supine CT Colonography.

    abstract:PURPOSE:Robust registration of prone and supine colonie surfaces acquired during CT colonography may lead to faster and more accurate detection of colorectal cancer and polyps. Any directional bias when registering one surface to the other could precipitate incorrect anatomical correspondence and engender reader error....

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4736159

    authors: Roth H,McClelland J,Modat M,Hampshire T,Boone D,Hu M,Ourselin S,Halligan S,Hawkes D

    更新日期:2012-06-01 00:00:00

  • Measurement of x-ray attenuation coefficients of aqueous solutions of indocyanine green and glycated chitosan.

    abstract::We report our experimental results of measurements of x-ray attenuation coefficients of aqueous solutions of a light absorbing dye, indocyanine green, and an immunoadjuvant, glycated chitosan. In the treatment of metastatic tumors in rats using a novel laser immunotherapy these solutions were administered in situ. The...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598633

    authors: Xu F,Liu H,Wu X,Jiang H,Nordquist RE,Chen WR

    更新日期:1999-07-01 00:00:00