Abstract:
PURPOSE:The response of human cells to applied electrical signals depends on the cellular health status, because it is influenced by the composition and structure of the main cellular components. Therefore, electrical impedance-based techniques can be considered as sensitive tools to investigate healthy or disease state at cellular level. The goal of this study is to show that different types of in vitro cellular lines, related to different health status, can be differentiated using impedance spectra analysis. METHODS:Three different types of human breast cell line, corresponding to healthy, cancerous, and metastatic adenocarcinoma cells, were measured by means of electrical impedance spectroscopy. By modeling the investigated cells with proper resistive and capacitive circuital elements, the magnitude of the cell electrical components and spectra of real and imaginary part of dielectric permittivity were obtained. The latter were subsequently examined with a commonly adopted mathematical model, in order to estimate the values of specific dielectric parameters for the three different cellular lines. RESULTS:The relative variation of cellular capacitance with respect to that of the culture medium, estimated at 100 Hz, has a larger value for the two types of cancerous cells with respect to the noncancerous type. Furthermore, the ratio between the real and imaginary part of the dielectric permittivity function has larger values for metastatic cells with respect to the normal and nonmetastatic ones. Therefore, the mentioned relative capacitance allows to discriminate between normal and cancerous cells, whereas the results obtained for the dielectric function can discriminate between metastatic and nonmetastatic cells. CONCLUSIONS:This study can be considered as an exploratory investigation of evaluating in vitro the health status of humans cells using selected electrical impedance parameters as potential markers. The obtained results highlight that a standard cultureware system, provided with interdigitated electrodes and appropriate impedance parameters, that is, cellular capacitance and the ratio between the imaginary and real part of cellular dielectric function, can be used to discriminate between healthy and cancerous breast cell lines, as well as different malignancy degrees.
journal_name
Med Physjournal_title
Medical physicsauthors
Ambrico M,Lasalvia M,Ligonzo T,Ambrico PF,Perna G,Capozzi Vdoi
10.1002/mp.14425subject
Has Abstractpub_date
2020-10-01 00:00:00pages
5373-5382issue
10eissn
0094-2405issn
2473-4209journal_volume
47pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract:PURPOSE:We propose a new metric called Distance Discordance (DD), which is defined as the distance between two anatomic points from two moving images, which are co-located on some reference image, when deformed onto another reference image. METHODS:To demonstrate the concept of DD, we created a reference software phan...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4736139
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:A compact, three-tesla magnetic resonance imaging (MRI) system has been developed. It features a 37 cm patient aperture, allowing the use of commercial receiver coils. Its design allows simultaneously for gradient amplitudes of 85 millitesla per meter (mT/m) sustained and 700 tesla per meter per second (T/m/s) ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4941362
更新日期:2016-03-01 00:00:00
abstract::The use of characteristic-line radiation from rare-earth targets bombarded by high-energy (up to 1 MeV) electron beams has been evaluated as an x-ray source for dual energy K-edge subtraction imaging of the human coronary arteries. Two characteristic-line x-ray sources, one using the split K alpha 1 and K alpha 2 line...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596648
更新日期:1991-09-01 00:00:00
abstract:PURPOSE:Using a new linear accelerator with high dose rate (800 MU/min), fast MLC motions (5.0 cm/s), fast gantry rotation (15 s/rotation), and 1 cm wide MLCs, we aimed to quantify the effects of complexity, arc number, and fractionation on interplay for breast and lung treatments under target motion. METHODS:To study...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12899
更新日期:2018-06-01 00:00:00
abstract::In this paper, we present a unified framework to reconstruct images for both fan beam and cone beam projections. The important feature of our theoretical framework is that it does not depend on the classical concept of the Radon transform at all. This property allows us to directly generalize the ideas and techniques ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1577252
更新日期:2003-06-01 00:00:00
abstract::Electron energy spectra and angular distributions, including angular spreads, were measured using magnetic spectrometer techniques, at isocenter, for two clinical linear accelerators: one scanning beam machine, which achieves field flatness by scanning a pencil beam over the desired field at the patient plane, and one...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597817
更新日期:1996-05-01 00:00:00
abstract:PURPOSE:To study the impact of target geometrical and linac operational parameters, such as target material and thickness, electron beam size, repetition rate, and mean current on the ability of the radiotherapy treatment head to deliver high-dose-rate x-ray irradiation in the context of novel linear accelerators capab...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12615
更新日期:2017-12-01 00:00:00
abstract:PURPOSE:To study and compare the dose response curves of the new GafChromic EBT3 film for megavoltage and kilovoltage x-ray beams, with different spatial resolution. METHODS:Two sets of EBT3 films (lot#A101711-02) were exposed to each x-ray beam (6MV, 15MV and 50kV) at 8 dose values (50-3200cGy). The megavoltage beams...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735153
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:This report describes upgrades and performance characterization of an experimental benchtop cone-beam x-ray fluorescence computed tomography (XFCT) system capable of determining the spatial distribution and concentration of metal probes such as gold nanoparticles (GNPs). Specifically, a high-power (~3 kW) indus...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13138
更新日期:2018-10-01 00:00:00
abstract:PURPOSE:The x-ray performance evaluation of digital x-ray detectors is based on the calculation of the modulation transfer function (MTF), the noise power spectrum (NPS), and the resultant detective quantum efficiency (DQE). The flat images used for the extraction of the NPS should not contain any fixed pattern noise (...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3664003
更新日期:2011-12-01 00:00:00
abstract::A fast method of seed matching and reconstruction in prostate brachytherapy is proposed. Previous approaches have required all seeds to be matched with all other seeds in other projections. The fast cross-projection algorithm for the reconstruction of seeds (Fast-CARS) allows for matching of a given seed with a subset...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1489044
更新日期:2002-07-01 00:00:00
abstract::Respiration can cause tumors in the thorax or abdomen to move by as much as 3 cm; this movement can adversely affect the planning and delivery of radiation treatment. Several techniques have been used to compensate for respiratory motion, but all have shortcomings. Manufacturers of computed tomography (CT) equipment h...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2044427
更新日期:2006-01-01 00:00:00
abstract:PURPOSE:To provide a fast computational method, based on the proximal graph solver (POGS) - A convex optimization solver using the alternating direction method of multipliers (ADMM), for calculating an optimal treatment plan in rotating shield brachytherapy (RSBT). RSBT treatment planning has more degrees of freedom th...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12486
更新日期:2017-10-01 00:00:00
abstract:PURPOSE:The authors combine the registration of 2D beam's eye view (BEV) images and 3D planning computed tomography (CT) images, with relative, markerless tumor tracking to provide automatic absolute tracking of physician defined volumes such as the gross tumor volume (GTV). METHODS:During treatment of lung SBRT cases...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4900603
更新日期:2014-12-01 00:00:00
abstract:PURPOSE:There is significant current interest in the use of biological image guidance in radiotherapy planning. In lung-cancer treatment, tumor motion due to respiration is known to be a limitation. This is particularly true in PET, where image data are collected over a number of minutes. An in-house-developed 4D PET a...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3276776
更新日期:2010-02-01 00:00:00
abstract::Results of an 18-alternative forced-choice experiment have shown that observers were capable of detecting a signal with a contrast of 1 in terms of 10-bit data which were displayed on a CRT monitor with an 8-bit video generator and a window width setting of 1024. We investigated the conditions under which 10-bit signa...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595919
更新日期:1986-05-01 00:00:00
abstract::In external beam radiotherapy, electronic portal imaging becomes more and more an indispensable tool for the verification of the patient setup. For the safe clinical introduction of high dose conformal radiotherapy like intensity modulated radiation therapy, on-line patient setup verification is a prerequisite to ensu...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1668391
更新日期:2004-04-01 00:00:00
abstract:PURPOSE:Efficient and accurate segmentations of 3D end-firing transrectal ultrasound (TRUS) images play an important role in planning of 3D TRUS guided prostate biopsy. However, poor image quality of the input 3D TRUS images, such as strong imaging artifacts and speckles, often makes it a challenging task to extract th...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4906129
更新日期:2015-02-01 00:00:00
abstract::The synchronization of dynamic multileaf collimator (DMLC) response with respiratory motion is critical to ensure the accuracy of DMLC-based four dimensional (4D) radiation delivery. In practice, however, a finite time delay (response time) between the acquisition of tumor position and multileaf collimator response ne...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1915017
更新日期:2005-06-01 00:00:00
abstract::One of the key components in modern LINAC room shielding design is the amount of 90 degrees head leakage radiation levels. With the general clinical acceptance of intensity-modulated radiation therapy (IMRT) technique, accurate knowledge of this quantity has become even more important. Measurement of 90 degrees head l...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2335489
更新日期:2006-09-01 00:00:00
abstract:PURPOSE:To characterize the radiation dose and three-dimensional (3D) imaging performance of a recently developed mobile, isocentric C-arm equipped with a flat-panel detector (FPD) for intraoperative cone-beam computed tomography (CBCT) (Cios Spin 3D, Siemens Healthineers) and to identify potential improvements in 3D i...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13983
更新日期:2020-03-01 00:00:00
abstract::Complementary metal-oxide-semiconductors (CMOS) active pixel sensors can be optically coupled to CsI:Tl phosphors forming a indirect active pixel flat panel imager (APFPI) for high performance medical imaging. The aim of this work is to determine the x-ray imaging capabilities of CMOS-based APFPI and study the signal ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3036117
更新日期:2009-01-01 00:00:00
abstract::Current methods for imaging joint motion are limited to either two-dimensional (2D) video fluoroscopy, or to animated motions from a series of static three-dimensional (3D) images. 3D movement patterns can be detected from biplane fluoroscopy images matched with computed tomography images. This involves several x-ray ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2000647
更新日期:2005-09-01 00:00:00
abstract:PURPOSE:A long-standing conundrum is why photoacoustic tomography (PAT) possesses the unique ability to produce images devoid of speckle artifacts while all other coherent imaging technologies do not. METHODS:In this paper, we explain the inherent mechanism that suppresses speckle in PAT, and the analysis was validate...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3187231
更新日期:2009-09-01 00:00:00
abstract::The nucletron Leipzig applicator is designed for (HDR) 192Ir brachy radiotherapy of surface lesions. The dosimetric characteristics of this applicator were investigated using simulation method based on Monte Carlo N-particle (MCNP) code and phantom measurements. The simulation method was validated by comparing calcula...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1812609
更新日期:2004-12-01 00:00:00
abstract:PURPOSE:Intensity Modulated Neutron Radiotherapy (IMNRT) has been commissioned for clinical use. The number of allowable segments in IMNRT plans is limited by MLC speed. Quality and deliverability of static IMNRT treatment plans using the TG-119 test suite were evaluated to establish guidelines for the number of segmen...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735662
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:Magnetic particle imaging (MPI) is a relatively new method to image the spatial distribution of magnetic nanoparticle (MNP) tracers administered to the body with high spatial and temporal resolution using an inhomogeneous magnetic field. The spatial information of the MNP's is encoded using a field free point (...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13411
更新日期:2019-04-01 00:00:00
abstract:PURPOSE:This paper presents the application of MAGIC-f gel in a three-dimensional dose distribution measurement and its ability to accurately measure the dose distribution from a tomotherapy unit. METHODS:A prostate intensity-modulated radiation therapy (IMRT) irradiation was simulated in the gel phantom and the treat...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4704496
更新日期:2012-05-01 00:00:00
abstract:PURPOSE:The aim of this study was to assess the suitability of Gafchromic EBT3 films for reference dose measurements in the beam of a prototype high dose-per-pulse linear accelerator (linac), capable of delivering electron beams with a mean dose-rate (Ḋm ) ranging from 0.07 to 3000 Gy/s and a dose-rate in pulse (Ḋp ) o...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12066
更新日期:2017-02-01 00:00:00
abstract:PURPOSE:To compare organ specific cancer incidence risks for standard and complex external beam radiotherapy (including cone beam CT verification) following breast conservation surgery for early breast cancer. METHOD:Doses from breast radiotherapy and kilovoltage cone beam CT (CBCT) exposures were obtained from thermo...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4748332
更新日期:2012-10-01 00:00:00