Abstract:
PURPOSE:To analyze the noise performance of the edge illumination phase-based x-ray imaging technique when applying "single-shot" phase retrieval. The latter consists in applying a sample-specific low-pass filter to the raw data, leading to "hybrid" images in which phase and attenuation contrast are merged with each other. The second objective is to compare the hybrid images with attenuation-only images based on their respective signal-to-noise ratio (SNR). METHODS:Noise is propagated from the raw images into the retrieved hybrid images, yielding analytic expressions for the variances and noise power spectra of the latter. An expression for the relative SNR between hybrid and attenuation images is derived. A comparison with simulated data is performed. Experimental data are also shown and discussed in the context of the theory. RESULTS:The noise transfer into the retrieved hybrid images is strongly related to the setup and acquisition parameters, as well as the imaged sample itself. Consequently, the relative merit between hybrid and attenuation images also depends on these criteria. Generally, the hybrid approach tends to perform worse for highly attenuating samples, as the availability of phase contrast is outweighed by the loss of photons that is necessarily encountered in hybrid acquisitions. On the contrary, the hybrid approach can lead to a much better SNR for weakly attenuating samples, as here phase effects lead to much stronger contrast, outweighing the reduction in photon numbers. CONCLUSIONS:The analytic expressions inform the design of edge illumination setups that lead to minimum noise transfer into the retrieved hybrid images. We also anticipate our theory to guide the decision as to which imaging mode (hybrid or attenuation) to use in order to maximize SNR for a specific sample.
journal_name
Med Physjournal_title
Medical physicsauthors
Hagen CK,Roche I Morgó O,Olivo Adoi
10.1002/mp.14366subject
Has Abstractpub_date
2020-09-01 00:00:00pages
4439-4449issue
9eissn
0094-2405issn
2473-4209journal_volume
47pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract::Intrafraction organ motion can limit the advantage of highly conformal dose techniques such as intensity modulated radiation therapy (IMRT) due to target position uncertainty. To ensure high accuracy in beam targeting, real-time knowledge of the target location is highly desired throughout the beam delivery process. T...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2905225
更新日期:2008-05-01 00:00:00
abstract::A new radiographic patient positioning technique developed for radiosurgery has been analyzed to show the effect of computed tomography (CT) slice thickness on the precision of target localization during treatment. The positioning technique establishes the pose of the patient's anatomy during treatment by comparing tr...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598500
更新日期:1999-02-01 00:00:00
abstract:PURPOSE:In the practice code of dosimetry, humidity effect is assumed to be constant as far as the measurements are performed in the relative humidity (RH) range of (20-80)%; thus, the humidity effect can be ignored with a dose uncertainty of 0.15%. This assumption is based on the previous experimental results by Niate...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13665
更新日期:2019-09-01 00:00:00
abstract:PURPOSE:Stereotactic body radiation therapy (SBRT) is a radiotherapy technique which uses high dose fractions with multiple coplanar and noncoplanar beams. Due to the large fractional doses, treatments are typically protracted and there are more fields than in conventional radiation treatment schemes. The effect of tem...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4709605
更新日期:2012-06-01 00:00:00
abstract::Electron energy spectra and angular distributions, including angular spreads, were measured using magnetic spectrometer techniques, at isocenter, for two clinical linear accelerators: one scanning beam machine, which achieves field flatness by scanning a pencil beam over the desired field at the patient plane, and one...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597817
更新日期:1996-05-01 00:00:00
abstract::Traditionally, short scan helical FDK algorithms have been implemented based on horizontal transaxial slices. However, not every point on the horizontal transaxial slice satisfies Tuy's condition for the corresponding (pi+fan angle) segment of helix, which means that some points on the horizontal slices are incomplete...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1916077
更新日期:2005-06-01 00:00:00
abstract::Significant advances have been made in recent years to improve photon dose calculation. However, accurate prediction of dose perturbation effects near the interfaces of different media, where charged particle equilibrium is not established, remain unsolved. Furthermore, changes in atomic number, which affect the multi...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597611
更新日期:1995-07-01 00:00:00
abstract:PURPOSE:Computed tomography (CT) and, in particular, cone beam CT (CBCT) have been increasingly used as a diagnostic tool in recent years. Patient motion during acquisition is common in CBCT due to long scan times. This results in degraded image quality and may potentially increase the number of retakes. Our aim was to...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13731
更新日期:2019-10-01 00:00:00
abstract::Deformable registration is needed for a variety of tasks in establishing the voxel correspondence between respiratory phases. Most registration algorithms assume or imply that the deformation field is smooth and continuous everywhere. However, the lungs are contained within closed invaginated sacs called pleurae and a...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2828378
更新日期:2008-02-01 00:00:00
abstract::In this paper, a unified framework of iterative algebraic reconstruction for emission computed tomography (ECT) and its application to positron emission tomography (PET) is presented. The unified framework is based on an algebraic image restoration model and contains conventional iterative algebraic reconstruction alg...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596954
更新日期:1993-11-01 00:00:00
abstract:PURPOSE:Cone beam computed tomography (CBCT) suffers from a large amount of scatter, resulting in severe scatter artifacts in the reconstructions. Recently, a new scatter correction approach, called improved primary modulator scatter estimation (iPMSE), was introduced. That approach utilizes a primary modulator that is...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12094
更新日期:2017-09-01 00:00:00
abstract::The design and construction of a Styrofoam cutter used in the fabrication of custom shielding blocks is described. ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594206
更新日期:1975-11-01 00:00:00
abstract::A method is presented for calculation of transmission functions for high energy photon beams through patients. These functions are being used in our clinic for prediction of portal dose images (PDIs) which are compared with PDIs measured with an electronic portal imaging device (EPID). The calculations are based on th...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598293
更新日期:1998-06-01 00:00:00
abstract:PURPOSE:To evaluate a commercial volumetric modulated arc therapy (VMAT), using multiple noncoplanar arcs, for linac-based cranial radiosurgery, as well as evaluate the combined accuracy of the VMAT dose calculations and delivery. METHODS:Twelve patients with cranial lesions of variable size (0.1-29 cc) and two multip...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3641874
更新日期:2011-11-01 00:00:00
abstract::Recent absorbed-dose-based protocols allow for two methods of calibrating electron beams using plane-parallel chambers, one using the N(Co)D,w for a plane-parallel chamber, and the other relying on cross-calibration of the plane-parallel chamber in a high-energy electron beam against a cylindrical chamber which has an...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1449876
更新日期:2002-03-01 00:00:00
abstract:PURPOSE:The simultaneous measurement of PET and magnetic resonance imaging (MRI) is an emerging field for molecular imaging research. Although optical fiber based PET∕MRI systems have advantages on less interference between PET and MRI, there is a drawback in reducing the scintillation light due to the fiber. To reduce...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4757911
更新日期:2012-11-01 00:00:00
abstract:PURPOSE:Due to the low contrast, blurry boundaries, and large amount of shadows in breast ultrasound (BUS) images, automatic tumor segmentation remains a challenging task. Deep learning provides a solution to this problem, since it can effectively extract representative features from lesions and the background in BUS i...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13268
更新日期:2019-01-01 00:00:00
abstract:PURPOSE:Over the last ten years, there has been an extensive growth in the development of microSPECT imagers. Most of the systems are based on the combination of conventional, relatively large gamma cameras with poor intrinsic spatial resolution and multipinhole collimators working in large magnification mode. Spatial ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4822621
更新日期:2013-11-01 00:00:00
abstract::An artificial neural network using input data derived from attenuation measurements was trained to generate spectral profiles (relative number of photons versus energy). Once the relative spectral distribution is reconstructed, absolute spectra (number of photons per unit exposure spectral distribution is reconstructe...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596495
更新日期:1990-07-01 00:00:00
abstract::A technique was developed to reduce the size and magnitude of the hot and cold spots in the abutting regions of photon and electron fields. The photon and electron fields were set up such that the photon field extended approximately 2 cm into the electron field in the abutting region. The region of the photon beam tha...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598753
更新日期:1999-11-01 00:00:00
abstract:PURPOSE:In this article, the authors studied the feasibility of estimating regional mechanical properties in cerebral aneurysms, integrating information extracted from imaging and physiological data with generic computational models of the arterial wall behavior. METHODS:A data assimilation framework was developed to ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3355933
更新日期:2010-04-01 00:00:00
abstract::A new approach to the calculation of the x-ray spectrum emerging from an x-ray tube is proposed. Theoretical results for the bremsstrahlung cross section appearing in the literature are summarized. Four different treatments of electron penetration, based on the work presented in Part I, are then used to generate brems...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2734726
更新日期:2007-06-01 00:00:00
abstract:PURPOSE:The Nakagami statistical model and Nakagami shape parameter m have been widely used in linear tissue characterization and preliminarily characterized the envelope distributions of nonlinear encapsulated microbubbles (EMBs). However, the Nakagami distribution of nonlinear scattering EMBs lacked a systematical in...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13833
更新日期:2019-12-01 00:00:00
abstract:PURPOSE:Hypoxia is one of the most important factors influencing clinical outcome after radiotherapy. Improved knowledge of factors affecting the levels and distribution of oxygen within a tumor is needed. The authors constructed a theoretical 3D model based on histological images to analyze the influence of vessel den...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4773886
更新日期:2013-02-01 00:00:00
abstract::For Monte Carlo linac simulations and patient dose calculations, it is important to accurately determine the phase space parameters of the initial electron beam incident on the target. These parameters, such as mean energy and radial intensity distribution, have traditionally been determined by matching the calculated...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2168433
更新日期:2006-04-01 00:00:00
abstract:PURPOSE:Using a new linear accelerator with high dose rate (800 MU/min), fast MLC motions (5.0 cm/s), fast gantry rotation (15 s/rotation), and 1 cm wide MLCs, we aimed to quantify the effects of complexity, arc number, and fractionation on interplay for breast and lung treatments under target motion. METHODS:To study...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12899
更新日期:2018-06-01 00:00:00
abstract::A new system of radiation dose mapping based on laser heating of thermoluminescent dosimetric plates (TLDP) has been developed. Application of this technique to intraoperative radiotherapy (IORT) has been investigated. Preliminary results show that TLDP are a possible alternative to radiological films and ionization c...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597725
更新日期:1996-08-01 00:00:00
abstract::Intravascular brachytherapy requires that the dose be specified within millimeters of the source. High dose gradients near brachytherapy sources require that the source-detector distance be accurately known for dosimetry purposes. Solid phantoms can be designed to accommodate these stringent requirements. This study r...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1376176
更新日期:2001-06-01 00:00:00
abstract:PURPOSE:Automated segmentation could improve the efficiency of modeling-based pelvic organ prolapse (POP) evaluations. However, segmentation performance is limited by the blurry soft tissue boundaries. In this study, we aimed to present a hybrid solution for uterus, rectum, bladder, and levator ani muscle segmentation ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14377
更新日期:2020-09-01 00:00:00
abstract::A quality assurance protocol has been developed to assess the relative accuracy of computerized monitor unit calculations. Results from this testing reveal that errors (defined as the difference between the computer results and those obtained using a standard formula with manual calculation) in monitor unit calculator...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596539
更新日期:1990-01-01 00:00:00