Automatic tumor segmentation in breast ultrasound images using a dilated fully convolutional network combined with an active contour model.

Abstract:

PURPOSE:Due to the low contrast, blurry boundaries, and large amount of shadows in breast ultrasound (BUS) images, automatic tumor segmentation remains a challenging task. Deep learning provides a solution to this problem, since it can effectively extract representative features from lesions and the background in BUS images. METHODS:A novel automatic tumor segmentation method is proposed by combining a dilated fully convolutional network (DFCN) with a phase-based active contour (PBAC) model. The DFCN is an improved fully convolutional neural network with dilated convolution in deeper layers, fewer parameters, and batch normalization techniques; and has a large receptive field that can separate tumors from background. The predictions made by the DFCN are relatively rough due to blurry boundaries and variations in tumor sizes; thus, the PBAC model, which adds both region-based and phase-based energy functions, is applied to further improve segmentation results. The DFCN model is trained and tested in dataset 1 which contains 570 BUS images from 89 patients. In dataset 2, a 10-fold support vector machine (SVM) classifier is employed to verify the diagnostic ability using 460 features extracted from the segmentation results of the proposed method. RESULTS:Advantages of the present method were compared with three state-of-the-art networks; the FCN-8s, U-net, and dilated residual network (DRN). Experimental results from 170 BUS images show that the proposed method had a Dice Similarity coefficient of 88.97 ± 10.01%, a Hausdorff distance (HD) of 35.54 ± 29.70 pixels, and a mean absolute deviation (MAD) of 7.67 ± 6.67 pixels, which showed the best segmentation performance. In dataset 2, the area under curve (AUC) of the 10-fold SVM classifier was 0.795 which is similar to the classification using the manual segmentation results. CONCLUSIONS:The proposed automatic method may be sufficiently accurate, robust, and efficient for medical ultrasound applications.

journal_name

Med Phys

journal_title

Medical physics

authors

Hu Y,Guo Y,Wang Y,Yu J,Li J,Zhou S,Chang C

doi

10.1002/mp.13268

subject

Has Abstract

pub_date

2019-01-01 00:00:00

pages

215-228

issue

1

eissn

0094-2405

issn

2473-4209

journal_volume

46

pub_type

杂志文章
  • Technical Note: 4D cone-beam CT reconstruction from sparse-view CBCT data for daily motion assessment in pencil beam scanned proton therapy (PBS-PT).

    abstract:PURPOSE:The number of pencil beam scanned proton therapy (PBS-PT) facilities equipped with cone-beam computed tomography (CBCT) imaging treating thoracic indications is constantly rising. To enable daily internal motion monitoring during PBS-PT treatments of thoracic tumors, we assess the performance of Motion-Aware Re...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14521

    authors: den Otter LA,Chen K,Janssens G,Meijers A,Both S,Langendijk JA,Rosen LR,Wu HT,Knopf AC

    更新日期:2020-12-01 00:00:00

  • Effect of T1-mapping technique and diminished image resolution on quantification of infarct mass and its ability in predicting appropriate ICD therapy.

    abstract:PURPOSE:Myocardial infarct (MI) may consist of an infarct core (IC) and a heterogeneous, semi-viable border zone (BZ). Patients with chronic MI in the left ventricular (LV) myocardium are at increased risk of developing ventricular arrhythmias, and may therefore qualify for implantable cardioverter defibrillator (ICD) ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12840

    authors: Farrag NA,Ramanan V,Wright GA,Ukwatta E

    更新日期:2018-04-01 00:00:00

  • An improved electron energy-loss straggling algorithm for Monte Carlo transport codes.

    abstract::The commonly used Blunck and Leisegang electron energy-loss distribution falls off too rapidly with increasing energy loss. Also, for large thicknesses and/or low-Z media, where their distribution should approach Landau's, it normalizes to 0.92 rather than 1.0, it overestimates the number of very small energy-loss eve...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595500

    authors: Weinhous MS,Nath R

    更新日期:1984-05-01 00:00:00

  • Specific recommendations for accurate and direct use of PET-CT in PET guided radiotherapy for head and neck sites.

    abstract:PURPOSE:To provide specific experience-based guidance and recommendations for centers wishing to develop, validate, and implement an accurate and efficient process for directly using positron emission tomography-computed tomography (PET-CT) for the radiotherapy planning of head and neck cancer patients. METHODS:A PET-...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4867856

    authors: Thomas CM,Pike LC,Hartill CE,Baker S,Woods E,Convery DJ,Greener AG

    更新日期:2014-04-01 00:00:00

  • Comparison of planned dose on different CT image sets to four-dimensional Monte Carlo dose recalculation using the patient's actual breathing trace for lung stereotactic body radiation therapy.

    abstract:PURPOSE:The need for four-dimensional (4D) treatment planning becomes indispensable when it comes to radiation therapy for moving tumors in the thoracic and abdominal regions. The primary purpose of this study is to combine the actual breathing trace during each individual treatment fraction with the Linac's log file i...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13579

    authors: Freislederer P,von Münchow A,Kamp F,Heinz C,Gerum S,Corradini S,Söhn M,Reiner M,Roeder F,Floca R,Alber M,Belka C,Parodi K

    更新日期:2019-07-01 00:00:00

  • Automatic three-dimensional correlation of CT-CT, CT-MRI, and CT-SPECT using chamfer matching.

    abstract::Image correlation is often required to utilize the complementary information in CT, MRI, and SPECT. A practical method for automatic image correlation in three-dimensions (3D) based on chamfer matching is described. The method starts with automatic extraction of contour points in one modality and automatic segmentatio...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597344

    authors: van Herk M,Kooy HM

    更新日期:1994-07-01 00:00:00

  • Noninvasive cardiac arrhythmia ablation with particle beams.

    abstract::Cardiac arrhythmias are a major health burden, associated with reduced quality of life and substantial morbidity and mortality. Current therapy includes moderately effective medication and catheter-based ablation of arrhythmogenic substrates in the heart. Catheter interventions frequently have to be repeated due to re...

    journal_title:Medical physics

    pub_type: 杂志文章,评审

    doi:10.1002/mp.12595

    authors: Graeff C,Bert C

    更新日期:2018-11-01 00:00:00

  • SU-E-T-635: Effect of Planning Parameters on Tomotherapy Dosimetric Quality and Treatment Efficiency.

    abstract:PURPOSE:To investigate how the setting of optimization parameters, fractional dose and tuning structure in tomotherapy treatment planning affects plan dosimetric quality and treatment efficiency. METHODS:A digital phantom to simulate head and neck radiotherapy was constructed for this study. Tumor was 10cm long C-shap...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735724

    authors: Lian J,Burkhardt K,Chera B,Chang S

    更新日期:2012-06-01 00:00:00

  • In vivo cancer diagnosis with optical spectroscopy and acoustically induced blood stasis using a murine MCa35 model.

    abstract::Ultrasound-induced blood stasis has been observed for more than 30 years. Most of the literature has been focused on the health risks associated with this phenomenon and methods employed to prevent stasis from occurring during ultrasound imaging. To date, experimental observations have been either in vitro or invasive...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2198196

    authors: Winey BA,Misic V,Liao L,Parker K,Fenton BM,Yu Y

    更新日期:2006-06-01 00:00:00

  • Robotic intrafractional US guidance for liver SABR: System design, beam avoidance, and clinical imaging.

    abstract:PURPOSE:To present a system for robotic 4D ultrasound (US) imaging concurrent with radiotherapy beam delivery and estimate the proportion of liver stereotactic ablative body radiotherapy (SABR) cases in which robotic US image guidance can be deployed without interfering with clinically used VMAT beam configurations. M...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4964454

    authors: Schlosser J,Gong RH,Bruder R,Schweikard A,Jang S,Henrie J,Kamaya A,Koong A,Chang DT,Hristov D

    更新日期:2016-11-01 00:00:00

  • Dosimetry evaluation of the GammaPod stereotactic radiosurgery device based on established AAPM and IAEA protocols.

    abstract:PURPOSE:The GammaPod is a novel dedicated prone breast stereotactic radiosurgery (SRS) device recently developed at the University of Maryland Medical Center. This device utilizes multiple rotating Co-60 sources to create highly conformal dose distributions for breast treatments, including boosts, partial breast irradi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14197

    authors: Becker SJ,Culberson WS,Poirier Y,Mutaf Y,Niu Y,Nichols EM,Yi B

    更新日期:2020-08-01 00:00:00

  • State-of-the-art in two-dimensional ultrasonic transducer array technology.

    abstract::Attention is given to means of sensing ultrasonic energy distributions over an area. Under the restraints appropiate to real-time imaging of deep body organs, piezoelectric arrays offer the most promising method. Adaptation of integrated circuit techniques to array assembly permits very large arrays of small elements ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594247

    authors: Maginness MG,Plummer JD,Beaver WL,Meindl JD

    更新日期:1976-09-01 00:00:00

  • The water-equivalence of phantom materials for 90Sr-90Y beta particles.

    abstract::Intravascular brachytherapy requires that the dose be specified within millimeters of the source. High dose gradients near brachytherapy sources require that the source-detector distance be accurately known for dosimetry purposes. Solid phantoms can be designed to accommodate these stringent requirements. This study r...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1376176

    authors: Buckley LA,Thomadsen BR,DeWerd LA

    更新日期:2001-06-01 00:00:00

  • Estimation of organ and effective dose due to Compton backscatter security scans.

    abstract:PURPOSE:To estimate organ and effective radiation doses due to backscatter security scanners using Monte Carlo simulations and a voxelized phantom set. METHODS:Voxelized phantoms of male and female adults and children were used with the GEANT4 toolkit to simulate a backscatter security scan. The backscatter system was...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4718680

    authors: Hoppe ME,Schmidt TG

    更新日期:2012-06-01 00:00:00

  • Implementation of a quality assurance program for computerized treatment planning systems.

    abstract::In the present investigation, the necessary tests for implementing a quality assurance program for a commercial treatment planning system (TPS), recently installed at Sao Paulo University School of Medicine Clinicas Hospital-Brazil, was established and performed in accordance with the new IAEA publication TRS 430, and...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2742779

    authors: Camargo PR,Rodrigues LN,Furnari L,Rubo RA

    更新日期:2007-07-01 00:00:00

  • Flattening filter removal for improved image quality of megavoltage fluoroscopy.

    abstract:PURPOSE:Removal of the linear accelerator (linac) flattening filter enables a high rate of dose deposition with reduced treatment time. When used for megavoltage imaging, an unflat beam has reduced primary beam scatter resulting in sharper images. In fluoroscopic imaging mode, the unflat beam has higher photon count pe...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4812678

    authors: Christensen JD,Kirichenko A,Gayou O

    更新日期:2013-08-01 00:00:00

  • Dosimetric characteristics of the Leipzig surface applicators used in the high dose rate brachy radiotherapy.

    abstract::The nucletron Leipzig applicator is designed for (HDR) 192Ir brachy radiotherapy of surface lesions. The dosimetric characteristics of this applicator were investigated using simulation method based on Monte Carlo N-particle (MCNP) code and phantom measurements. The simulation method was validated by comparing calcula...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1812609

    authors: Niu H,Hsi WC,Chu JC,Kirk MC,Kouwenhoven E

    更新日期:2004-12-01 00:00:00

  • Multigroup discrete ordinates modeling of 125I 6702 seed dose distributions using a broad energy-group cross section representation.

    abstract::Our purpose in this work is to demonstrate that the efficiency of dose-rate computations in 125I brachytherapy, using multigroup discrete ordinates radiation transport simulations, can be significantly enhanced using broad energy group cross sections without a loss of accuracy. To this end, the DANTSYS multigroup disc...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1429238

    authors: Daskalov GM,Baker RS,Rogers DW,Williamson JF

    更新日期:2002-02-01 00:00:00

  • Proton magnetic resonance spectroscopy in the brain: report of AAPM MR Task Group #9.

    abstract::AAPM Magnetic Resonance Task Group #9 on proton magnetic resonance spectroscopy (MRS) in the brain was formed to provide a reference document for acquiring and processing proton (1H) MRS acquired from brain tissue. MRS is becoming a common adjunct to magnetic resonance imaging (MRI), especially for the differential di...

    journal_title:Medical physics

    pub_type: 指南,杂志文章,实务指引,评审

    doi:10.1118/1.1501822

    authors: Drost DJ,Riddle WR,Clarke GD,AAPM MR Task Group #9.

    更新日期:2002-09-01 00:00:00

  • Quantitative simultaneous 99mTc/123I cardiac SPECT using MC-JOSEM.

    abstract::Simultaneous rest 99mTc-Sestamibi/ 123I-BMIPP cardiac SPECT imaging has the potential to replace current clinical 99mTc-Sestamibi rest/stress imaging and therefore has great potential in the case of patients with chest pain presenting to the emergency department. Separation of images of these two radionuclides is diff...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3063544

    authors: Ouyang J,Zhu X,Trott CM,El Fakhri G

    更新日期:2009-02-01 00:00:00

  • GLAaS: an absolute dose calibration algorithm for an amorphous silicon portal imager. Applications to IMRT verifications.

    abstract::A new calibration algorithm (GLAaS) to derive absolute dose maps from images acquired with the Varian PV-aS500 electronic portal imager (based on amorphous silicon detectors) has been developed incorporating the dependence of detector response on primary and transmitted radiation and on field size. Detector calibratio...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2218314

    authors: Nicolini G,Fogliata A,Vanetti E,Clivio A,Cozzi L

    更新日期:2006-08-01 00:00:00

  • Incorporating multi-leaf collimator leaf sequencing into iterative IMRT optimization.

    abstract::Intensity modulated radiation therapy (IMRT) treatment planning typically considers beam optimization and beam delivery as separate tasks. Following optimization, a multi-leaf collimator (MLC) or other beam delivery device is used to generate fluence patterns for patient treatment delivery. Due to limitations and char...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1477230

    authors: Siebers JV,Lauterbach M,Keall PJ,Mohan R

    更新日期:2002-06-01 00:00:00

  • Comparative dosimetry of diode and diamond detectors in electron beams for intraoperative radiation therapy.

    abstract::The aim of the present study is to examine the validity of using silicon semiconductor detectors in degraded electron beams with a broad energy spectrum and a wide angular distribution. A comparison is made with diamond detector measurements, which is the dosimeter considered to give the best results provided that dos...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1315317

    authors: Björk P,Knöös T,Nilsson P

    更新日期:2000-11-01 00:00:00

  • Comparison of proton and x-ray conformal dose distributions for radiosurgery applications.

    abstract::Highly focused dose distributions for radiosurgery applications are successfully achieved using either multiple static high-energy particle beams or multiple-arc circular x-ray beams from a linac. It has been suggested that conformal x-ray techniques using dynamically shaped beams with a moving radiation source would ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597654

    authors: Serago CF,Thornton AF,Urie MM,Chapman P,Verhey L,Rosenthal SJ,Gall KP,Niemierko A

    更新日期:1995-12-01 00:00:00

  • Theoretical investigation of the count rate capabilities of in-pixel amplifiers for photon counting arrays based on polycrystalline silicon TFTs.

    abstract:PURPOSE:Photon counting arrays (PCAs), capable of measuring the spectral information of individual x-ray photons and recording that information digitally, provide a number of advantages compared to conventional, energy-integrating active matrix flat-panel imagers - such as reducing the undesirable effects of electronic...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13128

    authors: Liang AK,Koniczek M,Antonuk LE,El-Mohri Y,Zhao Q

    更新日期:2018-10-01 00:00:00

  • Patient doses and projection angle in cone beam CT.

    abstract:PURPOSE:To investigate how x-ray tube projection angle affects organ and effective doses to patients undergoing a CT examination on a cone beam scanner. METHODS:The authors investigated two cone beam CT systems that use a flat panel detector to capture the x-ray pattern transmitted through patients. One system had the...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3397458

    authors: He W,Huda W,Magill D,Tavrides E,Yao H

    更新日期:2010-05-01 00:00:00

  • Design, development, and implementation of the radiological physics center's pelvis and thorax anthropomorphic quality assurance phantoms.

    abstract::The Radiological Physics Center (RPC) developed two heterogeneous anthropomorphic quality assurance phantoms for use in verifying the accuracy of radiation delivery: one for intensity-modulated radiation therapy (IMRT) to the pelvis and the other for stereotactic body radiation therapy (SBRT) to the thorax. The purpos...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2737158

    authors: Followill DS,Evans DR,Cherry C,Molineu A,Fisher G,Hanson WF,Ibbott GS

    更新日期:2007-06-01 00:00:00

  • Monte Carlo dosimetry for 103Pd, 125I, and 131Cs ocular brachytherapy with various plaque models using an eye phantom.

    abstract:PURPOSE:To investigate dosimetry for ocular brachytherapy for a range of eye plaque models containing(103)Pd, (125)I, or (131)Cs seeds with model-based dose calculations. METHODS:Five representative plaque models are developed based on a literature review and are compared to the standardized COMS plaque, including pla...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4864474

    authors: Lesperance M,Martinov M,Thomson RM

    更新日期:2014-03-01 00:00:00

  • A treatment planning study comparing HDR and AGIMRT for cervical cancer.

    abstract::The customization of brachytherapy dose distributions for gynecologic malignancies is limited by the spatial positioning of the applicators. We tested the hypothesis that applicator-guided intensity modulated radiation therapy (AGIMRT) has the potential to deliver highly conformal dose distributions to cervical tumors...

    journal_title:Medical physics

    pub_type: 临床试验,杂志文章

    doi:10.1118/1.1645678

    authors: Wahab SH,Malyapa RS,Mutic S,Grigsby PW,Deasy JO,Miller TR,Zoberi I,Low DA

    更新日期:2004-04-01 00:00:00

  • A convolution method for constructing primary beam profiles in the presence of beam modifiers.

    abstract::Empirical functions that describe primary beam profiles for radiotherapy treatment planning systems generally account for finite source size only on beams unmodified by blocks, wedges, or compensating filters. To incorporate the effects of extended sources on such modified beams and to treat the effect of an extended ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596222

    authors: Starkschall G

    更新日期:1988-09-01 00:00:00