Abstract:
:The commonly used Blunck and Leisegang electron energy-loss distribution falls off too rapidly with increasing energy loss. Also, for large thicknesses and/or low-Z media, where their distribution should approach Landau's, it normalizes to 0.92 rather than 1.0, it overestimates the number of very small energy-loss events, and its peak is shifted from lambda = -0.225 to 0.1. Because of these shortcomings, calculations made using this distribution yield a mean straggled energy loss which is lower than the value predicted by the continuous slowing down approximation (CSDA). An improved version of the Blunck-Leisegang distribution, which exhibits better normalization and falloff, has been developed. Further, an algorithm was created which (depending on the CSDA energy loss, Z,A, electron energy, and transport step size) samples the electron's straggled energy loss from the more accurate of the available distribution functions.
journal_name
Med Physjournal_title
Medical physicsauthors
Weinhous MS,Nath Rdoi
10.1118/1.595500subject
Has Abstractpub_date
1984-05-01 00:00:00pages
254-8issue
3eissn
0094-2405issn
2473-4209journal_volume
11pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract:PURPOSE:Most modern radiotherapy machines are built with a 2D kV imaging system. Combining this imaging system with a 2D-3D inference method would allow for a ready-made option for real-time 3D tumor tracking. This work investigates and compares the accuracy of four existing 2D-3D inference methods using both motion tr...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12765
更新日期:2018-03-01 00:00:00
abstract:PURPOSE:The purpose of the paper was to use a virtual phantom to identify a set of radiomic features from T1-weighted and T2-weighted magnetic resonance imaging (MRI) of the brain which is stable to variations in image acquisition parameters and to evaluate the effect of image preprocessing on radiomic features stabili...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13834
更新日期:2019-11-01 00:00:00
abstract::Small photon fields are increasingly used in modern radiotherapy and especially in IMRT and SRS/SRT treatments. The uncertainties related to small field profile measurements can introduce significant systematic errors to the overall treatment process. These measurements are challenging mainly due to the absence of cha...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2977829
更新日期:2008-10-01 00:00:00
abstract::A slat collimator in single photon emission computed tomography consists of a set of parallel slats. As the collimator spins, the detector measures a one-dimensional projection data set. A complete data set can be obtained by rotating the detector/collimator assembly around the object (patient) while the collimator sp...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1485057
更新日期:2002-07-01 00:00:00
abstract:PURPOSE:This report describes upgrades and performance characterization of an experimental benchtop cone-beam x-ray fluorescence computed tomography (XFCT) system capable of determining the spatial distribution and concentration of metal probes such as gold nanoparticles (GNPs). Specifically, a high-power (~3 kW) indus...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13138
更新日期:2018-10-01 00:00:00
abstract:PURPOSE:In this study the Octavius detector 729 ionization chamber (IC) array with the Octavius 4D phantom was characterized for flattening filter (FF) and flattening filter free (FFF) static and rotational beams. The device was assessed for verification with FF and FFF RapidArc treatment plans. METHODS:The response o...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4817482
更新日期:2013-09-01 00:00:00
abstract::Current MRI nonuniformity correction techniques are reviewed and investigated. Many approaches are used to remedy this artifact, but it is not clear which method is the most appropriate in a given situation, as the applications have been with different MRI coils and different clinical applications. In this work four w...
journal_title:Medical physics
pub_type: 杂志文章,评审
doi:10.1118/1.598357
更新日期:1998-09-01 00:00:00
abstract:PURPOSE:The harmonic spectrum of magnetic nanoparticles contains valuable information about the quantity and environment of the particles. Harmonic amplitudes have been used to produce quantitative images and ratios of these amplitudes have been used to monitor changes in the particle environment. Harmonic phase angles...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3426294
更新日期:2010-06-01 00:00:00
abstract:PURPOSE:CT reconstruction algorithms implemented on the GPU are highly sensitive to their implementation details and the hardware they run on. Fine-tuning an implementation for optimal performance can be a time consuming task and require many updates when the hardware changes. There are some techniques that do automati...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4773045
更新日期:2013-03-01 00:00:00
abstract:PURPOSE:To determine the accuracy and test-retest repeatability of fast radiofrequency (RF) transmit measurement approaches used in Dynamic Contrast Enhanced Magnetic Resonance Imaging (DCE-MRI). Spatial variation in the transmitted RF field introduces bias and increased variance in quantitative DCE-MRI metrics includi...
journal_title:Medical physics
pub_type: 杂志文章,多中心研究
doi:10.1002/mp.13518
更新日期:2019-06-01 00:00:00
abstract:PURPOSE:RapidArc is routinely used for stereotactic radiotherapy for lung cancer. While treatment dose is optimized and calculated on a static CT image, the motion of the target in conjunction with the motion of the MLC may Result in a delivered dose deviating from the planed dose. In this study, we investigate the dos...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4734660
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:Adequate evaluation of the results from multi-institutional trials involving light ion beam treatments requires consideration of the planning margins applied to both targets and organs at risk. A major uncertainty that affects the size of these margins is the conversion of x ray computed tomography numbers (XCT...
journal_title:Medical physics
pub_type: 杂志文章,多中心研究
doi:10.1118/1.4870956
更新日期:2014-06-01 00:00:00
abstract::Intensity Modulated Arc Therapy (IMAT) is a rotational variant of Intensity Modulated Radiation Therapy (IMRT) that can be implemented with or without angular dose rate optimization. The purpose of this study is to determine the inter-relationship among arc range, Multi-Leaf Collimator (MLC) leaf positions and angular...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2965975
更新日期:2008-07-01 00:00:00
abstract::Many problems in physics involve imaging objects with high spatial frequency content in a limited amount of time. The limitation of available experimental data leads to the infamous problem of diffraction limited data which manifests itself by causing ringing in the image. This ringing is due to the interference pheno...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596427
更新日期:1989-05-01 00:00:00
abstract::While simple, intravascular brachytherapy (IVB) presents a considerable potential for harm to the patient. The medical physicist maintains the responsibility to minimize the likelihood of operational problems or dosimetric errors. The principals for safe operation remain the same as with any radiotherapy treatment: to...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1524167
更新日期:2002-12-01 00:00:00
abstract:PURPOSE:To develop an accurate and efficient single-marker-based optical tracking system to enhance patient safety and quality of care in radiotherapy. METHODS:The optical tracking system consists of a Polaris camera as well as in-house software. The camera is mounted inside the treatment room and detects the location...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735240
更新日期:2012-06-01 00:00:00
abstract::Dose calculations for treatment planning of photon beam radiotherapy require a model of the beam to drive the dose calculation models. The beam shaping process involves scattering and filtering that yield radiation components which vary with collimator settings. The necessity to model these components has motivated th...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1898485
更新日期:2005-06-01 00:00:00
abstract::A spread-out Bragg peak (SOBP) is used in proton beam therapy to create a longitudinal conformality of the required dose to the target. In order to create this effect in a passive beam scattering system, a variety of components must operate in conjunction to produce the desired beam parameters. We will describe how th...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2776255
更新日期:2007-10-01 00:00:00
abstract::The MCNP Monte Carlo radiation transport code was modified for diagnostic medical physics applications. In particular, the modified code was thoroughly benchmarked for the production of polychromatic tungsten x-ray spectra in the 30-150 kV range. Validating the modified code for coupled electron-photon transport with ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1288397
更新日期:2000-12-01 00:00:00
abstract::We have recently installed a linear accelerator, modified to allow computer control of several machine parameters during irradiation of the patient. As an initial feasibility study of computer-controlled radiation therapy, its application to produce wedge-shaped dose distributions by moving the collimator jaws has bee...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594440
更新日期:1978-09-01 00:00:00
abstract:PURPOSE:Dynamic 18 F-FDG PET allows quantitative estimation of cerebral glucose metabolism both at the regional and local (voxel) level. Although sensitive to noise and highly computationally expensive, nonlinear least-squares (NLS) optimization stands as the reference approach for the estimation of the kinetic model p...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13366
更新日期:2019-03-01 00:00:00
abstract:PURPOSE:Bilateral filters have been substantially exploited in numerous magnetic resonance (MR) image restoration applications for decades. Due to the deficiency of theoretical basis on the filter parameter setting, empirical manipulation with fixed values and noise variance-related adjustments has generally been emplo...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12157
更新日期:2017-04-01 00:00:00
abstract::During the past decade the use of undersampled acquisition and constrained reconstruction have led to significant increases in data acquisition speed, SNR, spatial resolution and temporal resolution in MR imaging. When a separately acquired constraining image is combined with an angiographic time series the traditiona...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735797
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:Partial scan reconstruction (PSR) artifacts are present in myocardial perfusion imaging using dynamic multidetector computed tomography (MDCT). PSR artifacts appear as temporal CT number variations due to inconsistencies in the angular data range used to reconstruct images and compromise the quantitative value ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3665767
更新日期:2012-01-01 00:00:00
abstract:PURPOSE:To develop a novel three-dimensional (3D) hybrid-encoding framework using compressed sensing (CS) and Toeplitz encoding with variable phase-scrambled radio-frequency (RF) excitation, which has the following advantages: low power deposition of RF pulses, reduction of the signal dynamic range, no additional hardw...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13987
更新日期:2020-04-01 00:00:00
abstract::Nuclear Magnetic Resonance (NMR) permits the noninvasive measurement of blood flow signals unimpaired by clothes, bandages, casts, etc. The cylindrical crossed-coil NMR blood flowmeter was used to measure blood flow through a cross-section of the human forearm. Two calibration procedures are described: one for pulsati...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594989
更新日期:1981-07-01 00:00:00
abstract::Most detectors in current positron emission tomography (PET) scanners and prototypes use lutetium oxyorthosilicate (LSO) or lutetium yttrium oxyorthosilicate (LYSO) scintillators. The aim of this work is to provide a complete set of background energy spectra, due to the scintillator intrinsic radioactivity, for a wide...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14729
更新日期:2021-01-21 00:00:00
abstract:PURPOSE:Recent guidance by The Joint Commission and CRCPD recommendations require establishing CT reference dose levels (RDLs) for clinical protocols and recording CT dose metrics in the patient's medical record. This presentation addresses which dose values in the CT report should be recorded for the purposes of monit...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4734773
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:The previously described 2D standardized vessel-wall-plus-plaque thickness (VWT) maps constructed from 3D ultrasound vessel wall measurements using an arc-length (AL) scaling approach adjusted the geometric variability of carotid arteries and has allowed for the comparisons of VWT distributions in longitudinal ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4966702
更新日期:2016-12-01 00:00:00
abstract::The objective of this work is to assess the suitability and performance of a new dosimeter system with a novel geometry for the quality assurance (QA) of volumetric modulated arc therapy (VMAT). The new dosimeter system consists of a hollow cylinder (15 and 25 cm inner and outer diameters) with 124 diodes embedded in ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3117563
更新日期:2009-05-01 00:00:00