Abstract:
PURPOSE:To develop an accurate and efficient single-marker-based optical tracking system to enhance patient safety and quality of care in radiotherapy. METHODS:The optical tracking system consists of a Polaris camera as well as in-house software. The camera is mounted inside the treatment room and detects the location of a single infra-red (IR) reflective marker affixed on patient skin in real-time. The tracking system safeguards patient from treating wrong sites by comparing real-time marker position to the position predicted by virtual simulation, which is independent of couch or any indexing system. The deviation of marker position is shown in color (red or green) to indicate accuracy of patient positioning. The system works in concert with record-and-verify (R&V) system to further enhance patient safety and smooth clinic work flow. Marker information matching the patient under treatment is automatically loaded by the tracking system when a setup or treatment field is loaded in R&V. In non-coplanar treatment, the system automatically adjusts expected marker coordinators by accounting for each beam's couch angle extracted from R&V. RESULTS:Accuracy of the developed tracking system on a pelvis phantom has been verified against a CBCT system to be within 1.0 mm for coplanar treatment. In non-coplanar treatment, uncertainty of the system increases as the distance of the marker relative to treatment isocenter. The system precisely and automatically loads in patient and marker information for each beam, in concert with our R&V system. CONCLUSIONS:We have developed an accurate and efficient single IR marker-based optical tracking system for patient treatment position verification. It significantly enhances patient safety with streamlined clinic work flow. The system can be readily upgraded for high-precision radiotherapy with the use of multiple markers (>4).
journal_name
Med Physjournal_title
Medical physicsauthors
Yan G,Lu B,Mittauer K,Liu C,Li Jdoi
10.1118/1.4735240subject
Has Abstractpub_date
2012-06-01 00:00:00pages
3744-3745issue
6Part12eissn
0094-2405issn
2473-4209journal_volume
39pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract::The dose received in the buildup region outside the primary beam has been measured for 60Co gamma rays and 6- and 18-MV X rays. The variation of this dose with field size and depth was evaluated. The effect of blocking trays and the importance of their design was determined. ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595508
更新日期:1984-05-01 00:00:00
abstract:PURPOSE:Current on-board imaging systems commonly used by modern linear accelerators (LINACs) have a limited field of view (FOV) for a cone-beam CT (CBCT) scan, which is typically less than 50 cm. Consequently, truncation artifacts often occur for large patients. The goal of this work is to investigate a novel method t...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3514130
更新日期:2010-12-01 00:00:00
abstract:PURPOSE:Accurate segmentation of lung and infection in COVID-19 computed tomography (CT) scans plays an important role in the quantitative management of patients. Most of the existing studies are based on large and private annotated datasets that are impractical to obtain from a single institution, especially when radi...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14676
更新日期:2020-12-23 00:00:00
abstract:PURPOSE:Real-time tumor position/shape measurement and dynamic beam tracking techniques allow accurate and continuous irradiation to moving tumor, but there can be a delay of several hundred milliseconds between observation and irradiation. A time-variant seasonal autoregressive (TVSAR) model has been proposed for comp...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4734680
更新日期:2012-06-01 00:00:00
abstract:OBJECTIVE:Carbon ion particle therapy delivers sharp Bragg's peaks, and hence can produce dose delivery of very high precision and conformality. To complement this characteristic, particle therapy centers implement a number of technologies unique to these centers, and are not commonly known to the medical physics commu...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735351
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:The aim of this study was to develop a dose calculation method which is applicable to the interseed attenuation and the geometry lacking the equilibrium radiation scatter conditions in brachytherapy. METHODS:The dose obtained from measurement with a radiophotoluminescent glass rod dosimeter (GRD) was compared ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3590370
更新日期:2011-06-01 00:00:00
abstract::Effectiveness of an oral presentation depends on the ability of the speaker to communicate with the audience. An important part of this communication is focusing on two to five key points and emphasizing those points during the presentation. Every aspect of the presentation should be purposeful and directed at facilit...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735944
更新日期:2012-06-01 00:00:00
abstract::Assessment of clinic and site specific margins are essential for the effective use of three-dimensional and intensity modulated radiation therapy. An electronic portal imaging device (EPID) based methodology is introduced which allows individual and population based CTV-to-PTV margins to be determined and compared wit...
journal_title:Medical physics
pub_type: 临床试验,杂志文章
doi:10.1118/1.1800712
更新日期:2004-11-01 00:00:00
abstract:PURPOSE:To overcome the problem of organ motion in intensity-modulated radiation therapy (IMRT), gated IMRT is often used for the treatment of lung cancer. In this study, the authors investigated the accuracy of the delivered monitor units (MUs) from each segment during gated IMRT using a two-dimensional detector array...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3310806
更新日期:2010-03-01 00:00:00
abstract::A comprehensive performance testing program is an essential ingredient of high-quality single-photon emission computed tomography (SPECT). Many of the procedures previously published are complicated, time consuming, or require a special testing environment. This Task Group developed a protocol for evaluating SPECT ima...
journal_title:Medical physics
pub_type: 指南,杂志文章
doi:10.1118/1.597605
更新日期:1995-04-01 00:00:00
abstract:PURPOSE:Diffusion magnetic resonance imaging (MRI) in combination with functional MRI promises a whole new vista for scientists to investigate noninvasively the structural and functional connectivity of the human brain-the human connectome, which had heretofore been out of reach. As with other imaging modalities, diffu...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3700166
更新日期:2012-05-01 00:00:00
abstract::We have made a comparative investigation of the estimated spectra obtained by the Laplace transform analysis of the transmitted exposure data measured in an absorption study of a 4-MV x-ray beam. Four transform pair models currently used with this method have been evaluated. It has been determined that the Archer-Wagn...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595878
更新日期:1986-05-01 00:00:00
abstract:PURPOSE:To evaluate both the Calypso Systems' (Calypso Medical Technologies, Inc., Seattle, WA) localization accuracy in the presence of wireless metal-oxide-semiconductor field-effect transistor (MOSFET) dosimeters of dose verification system (DVS, Sicel Technologies, Inc., Morrisville, NC) and the dosimeters' reading...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3578602
更新日期:2011-05-01 00:00:00
abstract:INTRODUCTION:Ultrasound (US) guidance of the prostate has long been conducted using a transabdominal (TA) approach. More recently, a transperineal (TP) approach has been made available for image guidance. Our aim was to determine if both methods produced similar alignments within the same patients. MATERIALS AND METHO...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14522
更新日期:2020-12-01 00:00:00
abstract::A theoretical analysis of the x-ray phase contrast imaging and its validation via synchrotron radiation imaging is here presented. Two different mathematical models have been followed: the simpler ray-optical approach and the more rigorous Fresnel-Kirchoff diffraction theory. Subsequently, the conditions upon which th...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2126207
更新日期:2005-12-01 00:00:00
abstract:PURPOSE:Theoretical reasoning suggests that direct conversion digital x-ray detectors based upon photoconductive amorphous-selenium (a-Se) could attain very high values of the MTF (modulation transfer function) at spatial frequencies well beyond 20 cycles mm(-1). One of the fundamental factors affecting resolution loss...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3673957
更新日期:2012-02-01 00:00:00
abstract:PURPOSE:To analyze the noise performance of the edge illumination phase-based x-ray imaging technique when applying "single-shot" phase retrieval. The latter consists in applying a sample-specific low-pass filter to the raw data, leading to "hybrid" images in which phase and attenuation contrast are merged with each ot...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14366
更新日期:2020-09-01 00:00:00
abstract::Absorbed doses from main charged-particle beams and charged-particle fragments have been measured with high accuracy for particle therapy, but there are few reports for doses from neutron components produced as fragments. This study describes the measurements on neutron doses produced by carbon beams; microdosimetric ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2767933
更新日期:2007-09-01 00:00:00
abstract:PURPOSE:Air-communicating well ionization chambers are commonly used to assess air kerma strength of sources used in brachytherapy. The signal produced is supposed to be proportional to the air density within the chamber and, therefore, a density-independent air kerma strength is obtained when the measurement is correc...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4831757
更新日期:2013-12-01 00:00:00
abstract::This study proposes an algorithm for selecting beam weight, wedge angle, and wedge orientation for three-dimensional radiation therapy treatment planning. According to dose gradient analysis, the necessary and sufficient condition for achieving a homogeneous dose over the target volume is that the total vector sum of ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1286591
更新日期:2000-08-01 00:00:00
abstract::A commercially available open MRI unit is under routine use for radiation therapy simulation. The effects of a gradient distortion correction (GDC) program used to post process the images were assessed by comparison with the known geometry of a phantom. The GDC reduced the magnitude of the distortions at the periphery...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1513991
更新日期:2002-11-01 00:00:00
abstract:PURPOSE:Efficacy of tuberculosis (TB) treatment is often monitored using chest radiography. Monitoring size of cavities in pulmonary tuberculosis is important as the size predicts severity of the disease and its persistence under therapy predicts relapse. The authors present a method for automatic cavity segmentation i...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4881096
更新日期:2014-07-01 00:00:00
abstract::CEA TVS film is a therapy verification film that has been recently introduced in the North American market. This film features linear characteristic curves for photon energies from 137Cs to 18 MV as reported by Cheng and Das [Med. Phys. 23, 1225 (1996)]. In Saskatoon, TVS film was investigated for its application in t...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598316
更新日期:1998-08-01 00:00:00
abstract:PURPOSE:Experimental dosimetry of high-dose-rate (HDR) 192 Ir brachytherapy (BT) sources is complicated due to high dose and dose-rate gradients, and softening of photon energy spectrum with depth. A single crystal synthetic diamond detector microDiamond (PTW 60019, Freiburg, Germany) has a small active volume, high se...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12694
更新日期:2018-01-01 00:00:00
abstract::The effectiveness of film-screen mammography is limited by tradeoffs between latitude and contrast, film granularity, and the need to increase dose when antiscatter methods are used. We are currently developing a scanned-projection digital mammography (SPDM) system to overcome these limitations. The system consists of...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596147
更新日期:1987-09-01 00:00:00
abstract::The purposes of this research are to investigate the effectiveness of our novel image features for segmentation of anatomic regions such as the lungs and the mediastinum in chest radiographs and to develop an automatic computerized method for image processing. A total of 85 screening chest radiographs from Johns Hopki...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598277
更新日期:1998-06-01 00:00:00
abstract:PURPOSE:Radiochromic film provides dose measurement at high spatial resolution, but often is not preferred for routine evaluation of patient-specific intensity modulated radiation therapy (IMRT) plans owing to ease-of-use factors. The authors have established an efficient protocol that combines calibration and measurem...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4754797
更新日期:2012-10-01 00:00:00
abstract::The dose distribution for an ovoid with a new tungsten shielding design was determined using Monte Carlo simulation. Standard Cesium-137 tube sources, tungsten shielding, and aluminum ovoid applicator were each modeled as a collection of solid objects. Dose was calculated in planes above, below, in front of, and on th...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598459
更新日期:1998-12-01 00:00:00
abstract:PURPOSE:Prostate cancer ranks as one of the most common malignancies and currently represents the second leading cancer-specific cause of death in men. The current use of single modality transrectal ultrasound (TRUS) for biopsy guidance has a limited sensitivity and specificity for accurately identifying cancerous lesi...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4803498
更新日期:2013-06-01 00:00:00
abstract:PURPOSE:The efficiency of radioembolization procedures could be greatly enhanced if results of the 99m Tc-MAA pretreatment procedure were immediately available in the interventional suite, enabling 1-day procedures as a result of direct estimation of the hepatic radiation dose and lung shunt fraction. This would, howev...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13253
更新日期:2019-01-01 00:00:00