Abstract:
PURPOSE:Most modern radiotherapy machines are built with a 2D kV imaging system. Combining this imaging system with a 2D-3D inference method would allow for a ready-made option for real-time 3D tumor tracking. This work investigates and compares the accuracy of four existing 2D-3D inference methods using both motion traces inferred from external surrogates and measured internally from implanted beacons. METHOD:Tumor motion data from 160 fractions (46 thoracic/abdominal patients) of Synchrony traces (inferred traces), and 28 fractions (7 lung patients) of Calypso traces (internal traces) from the LIGHT SABR trial (NCT02514512) were used in this study. The motion traces were used as the ground truth. The ground truth trajectories were used in silico to generate 2D positions projected on the kV detector. These 2D traces were then passed to the 2D-3D inference methods: interdimensional correlation, Gaussian probability density function (PDF), arbitrary-shape PDF, and the Kalman filter. The inferred 3D positions were compared with the ground truth to determine tracking errors. The relationships between tracking error and motion magnitude, interdimensional correlation, and breathing periodicity index (BPI) were also investigated. RESULTS:Larger tracking errors were observed from the Calypso traces, with RMS and 95th percentile 3D errors of 0.84-1.25 mm and 1.72-2.64 mm, compared to 0.45-0.68 mm and 0.74-1.13 mm from the Synchrony traces. The Gaussian PDF method was found to be the most accurate, followed by the Kalman filter, the interdimensional correlation method, and the arbitrary-shape PDF method. Tracking error was found to strongly and positively correlate with motion magnitude for both the Synchrony and Calypso traces and for all four methods. Interdimensional correlation and BPI were found to negatively correlate with tracking error only for the Synchrony traces. The Synchrony traces exhibited higher interdimensional correlation than the Calypso traces especially in the anterior-posterior direction. CONCLUSION:Inferred traces often exhibit higher interdimensional correlation, which are not true representation of thoracic/abdominal motion and may underestimate kV-based tracking errors. The use of internal traces acquired from systems such as Calypso is advised for future kV-based tracking studies. The Gaussian PDF method is the most accurate 2D-3D inference method for tracking thoracic/abdominal targets. Motion magnitude has significant impact on 2D-3D inference error, and should be considered when estimating kV-based tracking error.
journal_name
Med Physjournal_title
Medical physicsauthors
Montanaro T,Nguyen DT,Keall PJ,Booth J,Caillet V,Eade T,Haddad C,Shieh CCdoi
10.1002/mp.12765subject
Has Abstractpub_date
2018-03-01 00:00:00pages
1222-1232issue
3eissn
0094-2405issn
2473-4209journal_volume
45pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract:PURPOSE:A nanodosimeter is a type of detector which measures single ionizations in a small gaseous volume in order to obtain ionization cluster size probability distributions for characterization of radiation types. Working nanodosimeter detectors are usually bulky machines which require a lot of space. In this work, t...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14738
更新日期:2021-01-28 00:00:00
abstract:PURPOSE:Hybrid radiotherapy-MRI devices promise real time tracking of moving tumors to focus the radiation portals to the tumor during irradiation. This approach will benefit from the increased temporal resolution of MRI's data acquisition and reconstruction. In this work, the authors propose a novel spatial-temporal c...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4885960
更新日期:2014-08-01 00:00:00
abstract::Computed tomography dose index (CTDI) is a conventional indicator of the patient dose in CT studies. It is measured as the integration of the longitudinal single scan dose profile (SSDP) by using a 100-mm-long pencil ionization chamber and a single axial scan. However, the assumption that most of the SSDP is contained...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1835571
更新日期:2005-01-01 00:00:00
abstract:PURPOSE:There are growing expectations that imaging biomarkers for tumor therapeutic drug response assessment will speed up preclinical testing of anticancer drugs in rodent models. The only imaging biomarker presently approved by the U.S. Food and Drug Administration is tumor size measurement based on either World Hea...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3464491
更新日期:2010-09-01 00:00:00
abstract:PURPOSE:The purpose of this work was to assess the inherent image quality characteristics of a new multidetector computed tomography system in terms of noise, resolution, and detectability index as a function of image acquisition and reconstruction for a range of clinically relevant settings. METHODS:A multisized imag...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4923172
更新日期:2015-08-01 00:00:00
abstract:PURPOSE:There is an increasing interest in calculating linear energy transfer (LET) distributions for proton therapy treatments in order to assess the influence of this quantity in biological terms. Microdosimetric Monte Carlo (MC) simulations are useful tools to calculate dose-averaged LET, as this has been broadly pr...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13643
更新日期:2019-09-01 00:00:00
abstract:PURPOSE:To experimentally commission a dual-energy CT (DECT) joint statistical image reconstruction (JSIR) method, which is built on a linear basis vector model (BVM) of material characterization, for proton stopping power ratio (SPR) estimation. METHODS:The JSIR-BVM method builds on the relationship between the energ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13287
更新日期:2019-01-01 00:00:00
abstract:PURPOSE:External beam radiation therapy (EBRT) usually uses heterogeneous dose distributions in a given volume. Designing detectors for quality control of these treatments is still a developing subject. The size of the detectors should be small to enhance spatial resolution and ensure low perturbation of the beam. A hi...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4837178
更新日期:2014-01-01 00:00:00
abstract::Breast-conserving surgery combined with subsequent radiation therapy is a standard procedure in breast cancer treatment. The disadvantage of whole-breast beam irradiation is that it requires 20-25 treatment days, which is inconvenient for patients with limited mobility or who reside far from the treatment center. Howe...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3243865
更新日期:2009-11-01 00:00:00
abstract:PURPOSE:Magnetic resonance imaging (MRI)-guided percutaneous cryotherapy of abdominal lesions, an established procedure, uses MRI to guide and monitor the cryoablation of lesions. Methods to precisely guide cryotherapy probes with a minimum amount of trial-and-error are yet to be established. To aid physicians in attai...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14116
更新日期:2020-06-01 00:00:00
abstract:PURPOSE:As hypoxic cells are more resistant to photon radiation, it is desirable to obtain information about the oxygen distribution in tumors prior to the radiation treatment. Noninvasive techniques are currently not able to provide reliable oxygenation maps with sufficient spatial resolution; therefore mathematical m...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4812431
更新日期:2013-08-01 00:00:00
abstract:PURPOSE:To study the impact of target geometrical and linac operational parameters, such as target material and thickness, electron beam size, repetition rate, and mean current on the ability of the radiotherapy treatment head to deliver high-dose-rate x-ray irradiation in the context of novel linear accelerators capab...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12615
更新日期:2017-12-01 00:00:00
abstract:PURPOSE:The overall goal of this work is to improve the computed tomography (CT) image quality for patients with metal implants or fillings by completing the missing kilovoltage (kV) projection data with selectively acquired megavoltage (MV) data that do not suffer from photon starvation. When both of these imaging sys...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4901551
更新日期:2014-12-01 00:00:00
abstract:PURPOSE:The authors previously introduced a methodology to generate a realistic three-dimensional (3D), high-resolution, computer-simulated breast phantom based on empirical data. One of the key components of such a phantom is that it provides a means to produce a realistic simulation of clinical breast compression. In...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3637500
更新日期:2011-10-01 00:00:00
abstract:PURPOSE:Modern clinical accelerators are capable of producing ion beams from protons up to neon. This work compares the depth dose distribution and corresponding dose averaged linear energy transfer (LET) distribution, which is related to the biological effectiveness, for different ion beams (¹H, ⁴He, ⁶Li, ⁸Be, ¹⁰B, ¹²...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3662911
更新日期:2011-12-01 00:00:00
abstract::A PTW Riga diamond detector and LiF TLDs have been evaluated for use in proton beam dosimetry by comparing results of proton beam calibration with those obtained using thimble ionization chambers. The thimble ionization chambers were calibrated in terms of exposure while the TLDs and diamond detector were calibrated i...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597608
更新日期:1995-04-01 00:00:00
abstract::The dosimetry for radiocolloid therapy of cystic craniopharyngiomas is investigated. Analytical calculations based on the Loevinger and the Berger formulas for electrons and photons, respectively, are compared with Monte Carlo simulations. The role of the material of which the colloid introduced inside the craniophary...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1599653
更新日期:2003-09-01 00:00:00
abstract::The measurement of output factors for small fields is challenging and can lead to large dose errors in patient treatments if corrections for detector size and scatter from high-Z material are not applied. Due to its high spatial resolution and near tissue equivalence, GAFCHROMIC® film potentially provides a correction...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4740095
更新日期:2012-07-01 00:00:00
abstract:PURPOSE:Intensity modulated proton therapy (IMPT) is sensitive to errors, mainly due to high stopping power dependency and steep beam dose gradients. Conventional margins are often insufficient to ensure robustness of treatment plans. In this article, a method is developed that takes the uncertainties into account duri...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3556559
更新日期:2011-03-01 00:00:00
abstract::In nuclear magnetic resonance (NMR) imaging by the zeugmatographic methods, there is a common and unified theoretical description. All forms of two-dimensional and three-dimensional imaging involve NMR data which trace various geometric representations, in reciprocal transform space, of the subject's spatially blurred...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595470
更新日期:1984-01-01 00:00:00
abstract:PURPOSE:Currently, no 3D or 4D volumetric x-ray imaging techniques are available for intrafraction verification of target position during actual treatment delivery or in-between treatment beams, which is critical for stereotactic radiosurgery (SRS) and stereotactic body radiation therapy (SBRT) treatments. This study a...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4861820
更新日期:2014-02-01 00:00:00
abstract:PURPOSE:Researchers write many computer programs with unique implementations, usually requiring a great amount of effort for other researchers to learn how to install, configure, and use. Some programs require specialized hardware platforms such as GPU workstation or CPU cluster, which may not readily available for man...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735274
更新日期:2012-06-01 00:00:00
abstract::Stereo x-ray radiography attracts increasing attention in major clinical applications. The purpose of this paper is to analyze the 3D localization error for breast biopsy procedures and provide guidelines for improving its accuracy. Our prototype is a CCD based digital stereo x-ray imaging system. The mathematical mod...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598953
更新日期:2000-05-01 00:00:00
abstract:PURPOSE:Scatter is a major factor degrading the image quality of cone beam computed tomography (CBCT). Conventional scatter correction strategies require handcrafted analytical models with ad hoc assumptions, which often leads to less accurate scatter removal. This study aims to develop an effective scatter correction ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13583
更新日期:2019-07-01 00:00:00
abstract::The EGS4 Monte Carlo code has been used to investigate the response of a PTW/diamond detector irradiated in both clinical and monoenergetic megavoltage electron beams ranging in energy from 5 to 20 MeV. The sensitive volume of the PTW/diamond detector simulated has a thickness of 0.4 mm and a diameter of 4.4 mm. Irrad...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598593
更新日期:1999-05-01 00:00:00
abstract:PURPOSE:The objectives of this study were (a) to devise a technique for measuring quantum noise in clinical body computed tomography (CT) images and (b) to develop a model for predicting that noise with high accuracy. METHODS:The study included 83 clinical image sets at two dose levels (clinical and 50% reduced dose l...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4938588
更新日期:2016-01-01 00:00:00
abstract::This paper is concerned with the proposed Birmingham accelerator-based epithermal neutron beam for boron neutron capture therapy (BNCT). In particular, the option of producing a therapy beam at an orthogonal direction to the incoming protons is considered. Monte Carlo radiation transport simulations, both with and wit...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598479
更新日期:1999-01-01 00:00:00
abstract::Two new liquid ionization chamber (LIC) designs, consisting of cylindrical and plane-parallel configurations, are presented. They are designed to be suitable for high-precision measurements of absorbed dose-to-water at dose rates and photon energies typical for LDR intermediate photon energy brachytherapy sources. The...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598268
更新日期:1998-06-01 00:00:00
abstract::An algorithm, which combines the scanning beam with dynamic collimation to generate any arbitrary intensity profile, is presented. The desired intensity profile is assumed to be piecewise linear. The dynamic collimation method used is the "sliding window." The algorithm can be used either for a given scanning beam pro...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597672
更新日期:1996-01-01 00:00:00
abstract::Accurate and reliable thermometry is essential in the development of microwave-induced hyperthermal cancer therapy. While temperature measurements in strong electromagnetic fields usually require special sensors, this does not hold true for interstitial radiator/sensor systems. Miniature thermistors (with metallic lea...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595261
更新日期:1983-05-01 00:00:00