:The EGS4 Monte Carlo code has been used to investigate the response of a PTW/diamond detector irradiated in both clinical and monoenergetic megavoltage electron beams ranging in energy from 5 to 20 MeV. The sensitive volume of the PTW/diamond detector simulated has a thickness of 0.4 mm and a diameter of 4.4 mm. Irradiation was simulated at various depths in a water phantom. The results show that the PTW/diamond detector has a constant response (within 1.0%) in electron beams if irradiated at depths closed to dmax, and its response is almost independent of irradiation depth or incident electron energy (within 3%). A detailed examination of the average detector dose shows that the sensitive volume of the PTW/diamond detector acts as a Spencer-Attix cavity within 1%. The encapsulation of the bare diamond detector with low-Z epoxy and polystyrene wall material does not affect its response in electron beams. The difference in response between the unencapsulated (TLD) and the encapsulated form of the detector is less than 0.5% for all depths over electron energy range investigated.
journal_name
Med Physjournal_title
Medical physicsauthors
Mobit PN,Sandison GAdoi
10.1118/1.598593subject
Has Abstractpub_date
1999-05-01 00:00:00pages
839-44issue
5eissn
0094-2405issn
2473-4209journal_volume
26pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract:PURPOSE:The purpose of this study is to evaluate the feasibility of kilovoltage cone-beam CT (CBCT) images that are obtained with the Varian On-Board Imager in dose calculation at each radiation therapy. METHODS:CBCT images are commonly degraded by scattered radiations originating in the patient's body, and so the CT ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4734936
更新日期:2012-06-01 00:00:00
abstract::A commercially available open MRI unit is under routine use for radiation therapy simulation. The effects of a gradient distortion correction (GDC) program used to post process the images were assessed by comparison with the known geometry of a phantom. The GDC reduced the magnitude of the distortions at the periphery...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1513991
更新日期:2002-11-01 00:00:00
abstract:PURPOSE:Contrast-enhanced imaging of the breast is frequently used in breast MRI and has recently become more common in mammography. The purpose of this study was to make single-scan contrast-enhanced imaging feasible for photon-counting breast CT (pcBCT) and to assess the spectral performance of a pcBCT scanner by eva...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14133
更新日期:2020-07-01 00:00:00
abstract:PURPOSE:The authors had previously published measurements of the detectability of disk-shaped contrast objects in images obtained from a C-arm CT system. A simple approach based on Rose's criterion was used to scale the date, assuming the threshold for the smallest diameter detected should be inversely proportional to ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3397465
更新日期:2010-05-01 00:00:00
abstract:PURPOSE:The response of human cells to applied electrical signals depends on the cellular health status, because it is influenced by the composition and structure of the main cellular components. Therefore, electrical impedance-based techniques can be considered as sensitive tools to investigate healthy or disease stat...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14425
更新日期:2020-10-01 00:00:00
abstract:PURPOSE:The objective of this study was to evaluate organ dose and the effective dose to patients undergoing tomosynthesis (TS) and C-arm cone-beam computed tomography (CBCT) examinations and to compare the doses to those in multidetector CT (MDCT) scans. METHODS:Patient doses were measured with small sized silicon-ph...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3465045
更新日期:2010-08-01 00:00:00
abstract::Machine outputs, peak scatter factors, and central axis percentage depth dose distributions were measured for various phantom sizes in large radiation fields produced at extended distances by cobalt, 6-MV, and 10-MV photon beams. The results can be applied to practical total body irradiation procedures which usually i...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595686
更新日期:1985-09-01 00:00:00
abstract::An overall practical dosimetric study of a 10-MV photon beam produced by a Varian Clinac-18 linear accelerator is presented. In particular measurements were made to provide data which could be utilized in computerized dosage calculations using the concept of dividing the radiation beam into primary and scatter compone...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594311
更新日期:1977-03-01 00:00:00
abstract:PURPOSE:The quantification of vessel wall morphology and plaque burden requires vessel segmentation, which is generally performed by manual delineations. The purpose of our work is to develop and evaluate a new 3D model-based approach for carotid artery wall segmentation from dual-sequence MRI. METHODS:The proposed me...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12476
更新日期:2017-10-01 00:00:00
abstract::The purpose of this paper is to determine the correlation between dose-volume histogram (DVH) and dose wall-histogram (DWH) in the evaluation of rectal complications for prostate cancer patients treated with three-dimensional conformal radiotherapy (3D-CRT). A retrospective analysis of DVHs and DWHs of a subset of 25 ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1951427
更新日期:2005-08-01 00:00:00
abstract::The physical factors that govern 2D and 3D imaging performance may be understood from quantitative analysis of the spatial-frequency-dependent signal and noise transfer characteristics [e.g., modulation transfer function (MTF), noise-power spectrum (NPS), detective quantum efficiency (DQE), and noise-equivalent quanta...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3002414
更新日期:2008-12-01 00:00:00
abstract::A Monte Carlo method was developed and implemented to simulate x-ray photon transport. Simulations consisted of a pencil beam of monoenergetic photons with energies from 50 to 110 keV incident on water and aluminum slabs. The dependence of scatter fraction and multiple scattering on x-ray energy, scatterer thickness, ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596268
更新日期:1988-11-01 00:00:00
abstract:PURPOSE:Proton radiotherapy for head-and-neck cancer (HNC) aims to improve organ-at-risk (OAR) sparing over photon radiotherapy. However, it may be less robust for setup and range uncertainties. The authors investigated OAR sparing and plan robustness for spot-scanning proton planning techniques and compared these with...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4933245
更新日期:2015-11-01 00:00:00
abstract::It is known that motion of an object imaged by magnetic resonance imaging leads to errors and artifacts in the image. This effect is especially important when a pulse sequence with long echo time (TE) and long TR is used to provide T2-weighted images. We have modified the usual spin warp imaging pulse sequence in a wa...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596026
更新日期:1987-07-01 00:00:00
abstract::The widespread application of positron emission tomography (PET) in clinical oncology has driven this imaging technology into a number of new research and clinical arenas. Increasing numbers of patient scans have led to an urgent need for efficient data handling and the development of new image analysis techniques to ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2432404
更新日期:2007-02-01 00:00:00
abstract::In this study, BrachyDose, a recently developed EGSnrc Monte Carlo code for rapid brachytherapy dose calculations, has been benchmarked by reproducing previously published dosimetry parameters for three brachytherapy seeds with varied internal structure and encapsulation. Calculations are performed for two 125I seeds ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2400843
更新日期:2007-02-01 00:00:00
abstract:PURPOSE:The cardiovascular system (CVS) regulation can be studied from a central viewpoint, through heart rate variability (HRV) data, and from a peripheral viewpoint, through laser Doppler flowmetry (LDF) signals. Both the central and peripheral CVSs are regulated by several interacting mechanisms, each having its own...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3512796
更新日期:2010-12-01 00:00:00
abstract:PURPOSE:To investigate how x-ray tube projection angle affects organ and effective doses to patients undergoing a CT examination on a cone beam scanner. METHODS:The authors investigated two cone beam CT systems that use a flat panel detector to capture the x-ray pattern transmitted through patients. One system had the...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3397458
更新日期:2010-05-01 00:00:00
abstract:PURPOSE:Magnetic particle imaging (MPI) is a relatively new method to image the spatial distribution of magnetic nanoparticle (MNP) tracers administered to the body with high spatial and temporal resolution using an inhomogeneous magnetic field. The spatial information of the MNP's is encoded using a field free point (...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13411
更新日期:2019-04-01 00:00:00
abstract:PURPOSE:The segmentation accuracy of medical images was improved by increasing the number of training samples using a local image warping technique. The performance of the proposed method was evaluated in the segmentation of breast masses, prostate and brain tumors, and lung nodules. METHODS:We propose a simple data a...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14651
更新日期:2020-12-10 00:00:00
abstract:PURPOSE:The authors introduce a novel method for defining standardized uptake values (SUVs) in PET∕CT based on routinely collected CT data. The goal of the study is to reduce, if possible, the variability of SUV in a heterogeneous population. Two well established methods for defining SUV are based on body weight (BW) a...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4816656
更新日期:2013-09-01 00:00:00
abstract:PURPOSE:This work introduces a rigid registration framework for patient positioning in radiotherapy, based on real-time surface acquisition by a time-of-flight (ToF) camera. Dynamic properties of the system are also investigated for future gating/tracking strategies. METHODS:A novel preregistration algorithm, based on...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3664006
更新日期:2012-01-01 00:00:00
abstract:PURPOSE:Cone-beam CT (CBCT) images contain severe shading artifacts mostly due to scatter. Many algorithms have been proposed to alleviate this problem by data correction on projections. Sophisticated methods have also been designed to further improve the image quality when prior patient information is available. In th...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4736218
更新日期:2012-06-01 00:00:00
abstract::Administration of x-ray contrast agents during heart catheterization examination increases the absorbed radiation dose in tissue. To estimate the dose absorbed by the blood of children undergoing diagnostic heart catheterization and angiocardiography, a number of measurements and calculations were conducted. First, en...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594613
更新日期:1979-11-01 00:00:00
abstract:PURPOSE:The implementation of an accurate beam model is an integral part of the commissioning of any planning system. This process is especially challenging in the case of IMRT beam models owing to the complexity of small field sizes and MLC leaf-end and tongue-and-groove effects. The question of how to judge the quali...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735679
更新日期:2012-06-01 00:00:00
abstract::The dose distribution for an ovoid with a new tungsten shielding design was determined using Monte Carlo simulation. Standard Cesium-137 tube sources, tungsten shielding, and aluminum ovoid applicator were each modeled as a collection of solid objects. Dose was calculated in planes above, below, in front of, and on th...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598459
更新日期:1998-12-01 00:00:00
abstract::We are evaluating the usefulness of stereomammography in improving breast cancer diagnosis. One area that we are investigating is whether the improved depth perception associated with stereomammography might be significantly enhanced with the use of a virtual 3D cursor. A study was performed to evaluate the accuracy o...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.599008
更新日期:2000-06-01 00:00:00
abstract::A theoretical analysis of the x-ray phase contrast imaging and its validation via synchrotron radiation imaging is here presented. Two different mathematical models have been followed: the simpler ray-optical approach and the more rigorous Fresnel-Kirchoff diffraction theory. Subsequently, the conditions upon which th...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2126207
更新日期:2005-12-01 00:00:00
abstract::A technique was developed to reduce the size and magnitude of the hot and cold spots in the abutting regions of photon and electron fields. The photon and electron fields were set up such that the photon field extended approximately 2 cm into the electron field in the abutting region. The region of the photon beam tha...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598753
更新日期:1999-11-01 00:00:00
abstract:PURPOSE:To use EGSnrc Monte Carlo simulations for magnetic field dosimetry to determine optimal measurement orientations, calculate beam quality conversion factors for 32 cylindrical and three parallel-plate (PP) ion chambers, evaluate the beam quality and angular dependence of these factors, and examine the magnetic f...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12716
更新日期:2018-02-01 00:00:00