Comparison of organ-at-risk sparing and plan robustness for spot-scanning proton therapy and volumetric modulated arc photon therapy in head-and-neck cancer.

Abstract:

PURPOSE:Proton radiotherapy for head-and-neck cancer (HNC) aims to improve organ-at-risk (OAR) sparing over photon radiotherapy. However, it may be less robust for setup and range uncertainties. The authors investigated OAR sparing and plan robustness for spot-scanning proton planning techniques and compared these with volumetric modulated arc therapy (VMAT) photon plans. METHODS:Ten HNC patients were replanned using two arc VMAT (RapidArc) and spot-scanning proton techniques. OARs to be spared included the contra- and ipsilateral parotid and submandibular glands and individual swallowing muscles. Proton plans were made using Multifield Optimization (MFO, using three, five, and seven fields) and Single-field Optimization (SFO, using three fields). OAR sparing was evaluated using mean dose to composite salivary glands (CompSal) and composite swallowing muscles (CompSwal). Plan robustness was determined for setup and range uncertainties (±3 mm for setup, ±3% HU) evaluating V95% and V107% for clinical target volumes. RESULTS:Averaged over all patients CompSal/CompSwal mean doses were lower for the three-field MFO plans (14.6/16.4 Gy) compared to the three-field SFO plans (20.0/23.7 Gy) and VMAT plans (23.0/25.3 Gy). Using more than three fields resulted in differences in OAR sparing of less than 1.5 Gy between plans. SFO plans were significantly more robust than MFO plans. VMAT plans were the most robust. CONCLUSIONS:MFO plans had improved OAR sparing but were less robust than SFO and VMAT plans, while SFO plans were more robust than MFO plans but resulted in less OAR sparing. Robustness of the MFO plans did not increase with more fields.

journal_name

Med Phys

journal_title

Medical physics

authors

Barten DL,Tol JP,Dahele M,Slotman BJ,Verbakel WF

doi

10.1118/1.4933245

subject

Has Abstract

pub_date

2015-11-01 00:00:00

pages

6589-98

issue

11

eissn

0094-2405

issn

2473-4209

journal_volume

42

pub_type

杂志文章
  • Carpal tunnel syndrome diagnosis by a self-normalization process and ultrasound compound imaging.

    abstract:PURPOSE:Carpal tunnel syndrome (CTS) is the common entrapment neuropathy that occurs due to compression of the median nerve at the wrist. Ultrasound images have been used to highlight anatomical variants of the median nerve, and CTS is thought to be associated to enlargement of the cross-sectional area (CSA) of the med...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4767754

    authors: Liao YY,Wu CC,Kuo TT,Chen JP,Hsu YW,Yeh CK

    更新日期:2012-12-01 00:00:00

  • Mitigating differential baseline shifts in locally advanced lung cancer patients using an average anatomy model.

    abstract:BACKGROUND AND PURPOSE:Differential baseline shifts between primary tumor and involved lymph nodes in locally advanced lung cancer patients compromise the accuracy of radiotherapy. The purpose of this study was to evaluate the performance of an average anatomy model (AAM) derived from repeat imaging and deformable regi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12271

    authors: Abdoli M,Van Kranen SR,Stankovic U,Rossi MMG,Belderbos JSA,Sonke JJ

    更新日期:2017-07-01 00:00:00

  • A multi-institutional study to assess adherence to lung stereotactic body radiotherapy planning goals.

    abstract:PURPOSE:A multi-institutional planning study was performed to evaluate the frequency that current guidelines established by Radiation Therapy Oncology Group (RTOG) protocols and other literature for lung stereotactic body radiotherapy (SBRT) treatments are followed. METHODS:A total of 300 patients receiving lung SBRT ...

    journal_title:Medical physics

    pub_type: 杂志文章,多中心研究

    doi:10.1118/1.4926551

    authors: Woerner A,Roeske JC,Harkenrider MM,Fan J,Aydogan B,Koshy M,Laureckas R,Vali F,Campana M,Surucu M

    更新日期:2015-08-01 00:00:00

  • The effect of coupling materials on specific absorption rate distributions at 915 MHz.

    abstract::Deionized water is commonly used to couple microwave applicators to the patient surface in the administration of local hyperthermia. Profiles of the specific absorption rate (SAR) at 1-cm depth show that deionized water coupling significantly distorts the SAR distributions of the Clini-Therm 915-MHz 10 X 10 and 15 X 1...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595881

    authors: Waterman FM,Nerlinger RE

    更新日期:1986-05-01 00:00:00

  • Optical image processing with liquid-crystal display for image intensifier/television systems.

    abstract::We have studied the effect of real-time optical image processing (OIP) in an image intensifier/television (II-TV) radiographic imaging system by using a liquid-crystal display (LCD) placed between the II and the TV camera. The LCD compresses the dynamic range of the transmitted image by modulating the spatial distribu...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596199

    authors: Lam KL,Chan HP,Doi K

    更新日期:1988-11-01 00:00:00

  • The role of water desorption on optical clearing of biotissue: studied with near infrared reflectance spectroscopy.

    abstract::In order to understand the role of water desorption, i.e., the opposite of water adsorption, in optical clearing of biological tissue created by the application of hyperosmotic agents, dynamics of water loss in fresh porcine muscle tissue administrated with glycerol or ethylene glycol was investigated with the near-in...

    journal_title:Medical physics

    pub_type:

    doi:10.1118/1.1576228

    authors: Xu X,Wang RK

    更新日期:2003-06-01 00:00:00

  • Computed tomography scanning with simultaneous patient translation.

    abstract::This paper deals with methods of reducing the total time required to acquire the projection data for a set of contiguous computed tomography (CT) images. Normally during the acquisition of a set of slices, the patient is held stationary during data collection and translated to the next axial location during an intersc...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596464

    authors: Crawford CR,King KF

    更新日期:1990-11-01 00:00:00

  • On the capabilities of conventional x-ray tubes to deliver ultra-high (FLASH) dose rates.

    abstract:PURPOSE:By means of Monte Carlo (MC) simulations and indirect measurements, we have evaluated the maximum dose rates achievable with conventional x-ray tubes and related them to FLASH therapy dose rates of >40 Gy/s. METHODS:Monte Carlo models of two 160 kV x-ray tubes, the 3-kW MXR-160/22 and the 6-kW MXR-165, were bu...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13858

    authors: Bazalova-Carter M,Esplen N

    更新日期:2019-12-01 00:00:00

  • Impact of transverse magnetic fields on dose response of a radiophotoluminescent glass dosimeter in megavoltage photon beams.

    abstract:PURPOSE:The purpose of this study was to investigate the impact of transverse magnetic fields on the dose response of a radiophotoluminescent glass dosimeter (RGD) in megavoltage photon beams. METHODS:The RGD relative response (i.e., RGD dose per absorbed dose to water at the midpoint of the detector in the absence of...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14054

    authors: Ito S,Araki F,Ohno T

    更新日期:2020-04-01 00:00:00

  • Onboard functional and molecular imaging: a design investigation for robotic multipinhole SPECT.

    abstract:PURPOSE:Onboard imaging-currently performed primarily by x-ray transmission modalities-is essential in modern radiation therapy. As radiation therapy moves toward personalized medicine, molecular imaging, which views individual gene expression, may also be important onboard. Nuclear medicine methods, such as single pho...

    journal_title:Medical physics

    pub_type: 信件

    doi:10.1118/1.4845195

    authors: Bowsher J,Yan S,Roper J,Giles W,Yin FF

    更新日期:2014-01-01 00:00:00

  • Effect of T1-mapping technique and diminished image resolution on quantification of infarct mass and its ability in predicting appropriate ICD therapy.

    abstract:PURPOSE:Myocardial infarct (MI) may consist of an infarct core (IC) and a heterogeneous, semi-viable border zone (BZ). Patients with chronic MI in the left ventricular (LV) myocardium are at increased risk of developing ventricular arrhythmias, and may therefore qualify for implantable cardioverter defibrillator (ICD) ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12840

    authors: Farrag NA,Ramanan V,Wright GA,Ukwatta E

    更新日期:2018-04-01 00:00:00

  • Dose enhancement in radiotherapy of small lung tumors using inline magnetic fields: A Monte Carlo based planning study.

    abstract:PURPOSE:To report on significant dose enhancement effects caused by magnetic fields aligned parallel to 6 MV photon beam radiotherapy of small lung tumors. Findings are applicable to future inline MRI-guided radiotherapy systems. METHODS:A total of eight clinical lung tumor cases were recalculated using Monte Carlo me...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4938580

    authors: Oborn BM,Ge Y,Hardcastle N,Metcalfe PE,Keall PJ

    更新日期:2016-01-01 00:00:00

  • Systematic feasibility analysis of performing elastography using reduced dose CT lung image pairs.

    abstract:PURPOSE:Elastography using computer tomography (CT) is a promising methodology that can provide patient-specific regional distributions of lung biomechanical properties. The purpose of this paper is to investigate the feasibility of performing elastography using simulated lower dose CT scans. METHODS:A cohort of eight...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14112

    authors: Hasse K,Hsieh SS,O'Connell D,Stiehl B,Min Y,Neylon J,Low DA,Santhanam AP

    更新日期:2020-08-01 00:00:00

  • Automated registration of diagnostic to prediagnostic x-ray mammograms: evaluation and comparison to radiologists' accuracy.

    abstract:PURPOSE:To compare and evaluate intensity-based registration methods for computation of serial x-ray mammogram correspondence. METHODS:X-ray mammograms were simulated from MRIs of 20 women using finite element methods for modeling breast compressions and employing a MRI/x-ray appearance change model. The parameter con...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3457470

    authors: Pinto Pereira SM,Hipwell JH,McCormack VA,Tanner C,Moss SM,Wilkinson LS,Khoo LA,Pagliari C,Skippage PL,Kliger CJ,Hawkes DJ,Silva IM

    更新日期:2010-09-01 00:00:00

  • Dosimetric effects of contrast media for catheter-based intravascular brachytherapy.

    abstract::The purpose of this work is to calculate the dose perturbations due to the presence of iodine contrast media in catheter-based intravascular brachytherapy (IVBT). The EGSnrc Monte Carlo system was used to perform the calculation for the two most commonly used beta and gamma sources (90Sr and 192Ir as well as for a var...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1367279

    authors: Li XA

    更新日期:2001-05-01 00:00:00

  • Energy spectra due to the intrinsic radiation of LYSO/LSO scintillators for a wide range of crystal sizes.

    abstract::Most detectors in current positron emission tomography (PET) scanners and prototypes use lutetium oxyorthosilicate (LSO) or lutetium yttrium oxyorthosilicate (LYSO) scintillators. The aim of this work is to provide a complete set of background energy spectra, due to the scintillator intrinsic radioactivity, for a wide...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14729

    authors: Domínguez-Jiménez DY,Alva-Sánchez H

    更新日期:2021-01-21 00:00:00

  • Development and clinical implementation of semi-automated treatment planning including 3D printable applicator holders in complex skin brachytherapy.

    abstract:PURPOSE:High-dose-rate brachytherapy (HDR-BT) is a treatment option for malignant skin diseases compared to external beam radiation therapy, HDR-BT provides improved target coverage, better organ sparing, and has comparable treatment times. This is especially true for large clinical targets with complex topologies. To ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13975

    authors: Guthier CV,Devlin PM,Harris TC,O'Farrell DA,Cormack RA,Buzurovic I

    更新日期:2020-03-01 00:00:00

  • Computerized characterization of masses on mammograms: the rubber band straightening transform and texture analysis.

    abstract::A new rubber band straightening transform (RBST) is introduced for characterization of mammographic masses as malignant or benign. The RBST transforms a band of pixels surrounding a segmented mass onto the Cartesian plane (the RBST image). The border of a mammographic mass appears approximately as a horizontal line, a...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598228

    authors: Sahiner B,Chan HP,Petrick N,Helvie MA,Goodsitt MM

    更新日期:1998-04-01 00:00:00

  • Compressed sensing for longitudinal MRI: An adaptive-weighted approach.

    abstract:PURPOSE:Repeated brain MRI scans are performed in many clinical scenarios, such as follow up of patients with tumors and therapy response assessment. In this paper, the authors show an approach to utilize former scans of the patient for the acceleration of repeated MRI scans. METHODS:The proposed approach utilizes the...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4928148

    authors: Weizman L,Eldar YC,Ben Bashat D

    更新日期:2015-09-01 00:00:00

  • Computerized detection of masses in digital mammograms: analysis of bilateral subtraction images.

    abstract::A computerized scheme is being developed for the detection of masses in digital mammograms. Based on the deviation from the normal architectural symmetry of the right and left breasts, a bilateral subtraction technique is used to enhance the conspicuity of possible masses. The scheme employs two pairs of conventional ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596610

    authors: Yin FF,Giger ML,Doi K,Metz CE,Vyborny CJ,Schmidt RA

    更新日期:1991-09-01 00:00:00

  • Effect of the first day correction on systematic setup error reduction.

    abstract::Treatment simulation is usually performed with a conventional simulator using kV X-rays or with a computed tomography (CT) simulator before the treatment course begins. The purpose is to verify patient setup under the same conditions as for treatment planning. Systematic (preparation) setup errors can be introduced by...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2727299

    authors: Wu Q,Lockman D,Wong J,Yan D

    更新日期:2007-05-01 00:00:00

  • Brain SPECT with short focal-length cone-beam collimation.

    abstract::Single-photon emission-computed tomography (SPECT) imaging of deep brain structures is compromised by loss of photons due to attenuation. We have previously shown that a centrally peaked collimator sensitivity function can compensate for this phenomenon, increasing sensitivity over most of the brain. For dual-head ins...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1929208

    authors: Park MA,Moore SC,Kijewski MF

    更新日期:2005-07-01 00:00:00

  • MO-F-BRCD-01: Stereotactic Body Radiation Therapy: Updates on Clinical, Biological, and Physics/QA:SBRT (Part 1): Biological and Clinical Updates.

    abstract::Stereotactic Body Radiation Therapy (SBRT) is an important form of cancer therapy with increasingly broad application across a spectrum of tumor types in primary and metastatic settings. In this presentation the radiation biology, clinical experience from various trials, and cautionary updates on normal tissue toleran...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735812

    authors: Read P

    更新日期:2012-06-01 00:00:00

  • Water-equivalent dosimeter array for small-field external beam radiotherapy.

    abstract::With the increasing complexity of dose patterns external beam radiotherapy, there is a great need for new types of dosimeters. We studied the first prototype of a new dosimeter array consisting of water-equivalent plastic scintillating fibers for dose measurement in external beam radiotherapy. We found that this array...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2719363

    authors: Archambault L,Beddar AS,Gingras L,Lacroix F,Roy R,Beaulieu L

    更新日期:2007-05-01 00:00:00

  • An outlook on x-ray CT research and development.

    abstract::Over the past decade, computed tomography (CT) theory, techniques and applications have undergone a rapid development. Since CT is so practical and useful, undoubtedly CT technology will continue advancing biomedical and non-biomedical applications. In this outlook article, we share our opinions on the research and de...

    journal_title:Medical physics

    pub_type: 杂志文章,评审

    doi:10.1118/1.2836950

    authors: Wang G,Yu H,De Man B

    更新日期:2008-03-01 00:00:00

  • The use of PET images for radiotherapy treatment planning: an error analysis using radiobiological endpoints.

    abstract:PURPOSE:There is significant current interest in the use of biological image guidance in radiotherapy planning. In lung-cancer treatment, tumor motion due to respiration is known to be a limitation. This is particularly true in PET, where image data are collected over a number of minutes. An in-house-developed 4D PET a...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3276776

    authors: Perrin R,Evans PM,Webb S,Partridge M

    更新日期:2010-02-01 00:00:00

  • Static multileaf collimator for fast-neutron therapy.

    abstract::This paper describes a multileaf collimator, designed to obtain irregularly shaped neutron fields, that fits into an existing fixed field-size collimator system. The shape of the desired portal field is obtained by appropriately setting the position of each leaf of the collimator. The collimator consists of 40 polyeth...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596084

    authors: Chu JC,Bloch P

    更新日期:1987-03-01 00:00:00

  • Beam modeling and verification of a photon beam multisource model.

    abstract::Dose calculations for treatment planning of photon beam radiotherapy require a model of the beam to drive the dose calculation models. The beam shaping process involves scattering and filtering that yield radiation components which vary with collimator settings. The necessity to model these components has motivated th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1898485

    authors: Ahnesjö A,Weber L,Murman A,Saxner M,Thorslund I,Traneus E

    更新日期:2005-06-01 00:00:00

  • Effect of beam number on organ-at-risk sparing in dynamic multileaf collimator delivery of intensity modulated radiation therapy.

    abstract::Due to practical limitations such as inter- and intraleaf transmission, nondivergent leaf end design, and leaf scatter, multileaf collimators (MLCs) are unable to accurately produce the ideal fluence patterns generated by inverse planning systems. Consequently, low dose regions receive substantially more radiation tha...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2779862

    authors: Popple RA,Fiveash JB,Brezovich IA

    更新日期:2007-10-01 00:00:00

  • Correspondence optimization in 2D standardized carotid wall thickness map by description length minimization: A tool for increasing reproducibility of 3D ultrasound-based measurements.

    abstract:PURPOSE:The previously described 2D standardized vessel-wall-plus-plaque thickness (VWT) maps constructed from 3D ultrasound vessel wall measurements using an arc-length (AL) scaling approach adjusted the geometric variability of carotid arteries and has allowed for the comparisons of VWT distributions in longitudinal ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4966702

    authors: Chen Y,Chiu B

    更新日期:2016-12-01 00:00:00