Multiscale entropy of laser Doppler flowmetry signals in healthy human subjects.

Abstract:

PURPOSE:The cardiovascular system (CVS) regulation can be studied from a central viewpoint, through heart rate variability (HRV) data, and from a peripheral viewpoint, through laser Doppler flowmetry (LDF) signals. Both the central and peripheral CVSs are regulated by several interacting mechanisms, each having its own temporal scale. The central CVS has been the subject of many multiscale studies. By contrast, these studies at the level of the peripheral CVS are very recent. Among the multiscale studies performed on the central CVS data, multiscale entropy has been proven to give interesting physiological information for diagnostic purposes. However, no multiscale entropy analysis has been performed on LDF signals. The authors' goal is therefore to propose a first multiscale entropy study of LDF data recorded in healthy subjects. METHODS:The LDF signals recorded in the forearm of seven healthy subjects are processed. Their period sampling is T=50 ms, and coarse-graining scales from T to 23T are studied. Also, for validation, the algorithm is first tested on synthetic signals of known theoretical multiscale entropy. RESULTS:The results reveal nonmonotonic evolution of the multiscale entropy of LDF signals, with a maximum at small scales around 7T and a minimum at longer scales around 18T, singling out in this way two distinctive scales where the LDF signals undergo specific changes from high to low complexity. This also marks a strong contrast with the HRV signals that usually display a monotonic increase in the evolution of the multiscale entropy. CONCLUSIONS:Multiscale entropy of LDF signals in healthy subjects shows variation with scales. Moreover, as the variation pattern observed appears similar for all the tested signals, multiscale entropy could potentially be a useful stationary signature for LDF signals, which otherwise are probe-position and subject dependent. Further work could now be conducted to evaluate possible diagnostic purposes of the multiscale entropy of LDF signals.

journal_name

Med Phys

journal_title

Medical physics

authors

Humeau A,Buard B,Mahé G,Rousseau D,Chapeau-Blondeau F,Abraham P

doi

10.1118/1.3512796

subject

Has Abstract

pub_date

2010-12-01 00:00:00

pages

6142-6

issue

12

eissn

0094-2405

issn

2473-4209

journal_volume

37

pub_type

杂志文章
  • Absorbed dose distributions from ophthalmic 106 Ru/106 Rh plaques measured in water with radiochromic film.

    abstract:PURPOSE:Brachytherapy with 106 Ru/106 Rh plaques offers good outcomes for small-to-medium choroidal melanomas and retinoblastomas. The dose measurement of the plaques is challenging, due to the small range of the emitted beta particles and steep dose gradients involved. The scarce publications on film dosimetry of 106 ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12777

    authors: Hermida-López M,Brualla L

    更新日期:2018-04-01 00:00:00

  • Linear motion correction in three dimensions applied to dynamic gadolinium enhanced breast imaging.

    abstract::Quantitative analysis of dynamic gadolinium-DTPA (diethylenetriamine pentaacetic acid) enhanced magnetic resonance imaging (MRI) is emerging as a highly sensitive tool for detecting malignant breast tissue. Three-dimensional rapid imaging techniques, such as keyhole MRI, yield high temporal sampling rates to accuratel...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598576

    authors: Krishnan S,Chenevert TL,Helvie MA,Londy FL

    更新日期:1999-05-01 00:00:00

  • Prior data assisted compressed sensing: a novel MR imaging strategy for real time tracking of lung tumors.

    abstract:PURPOSE:Hybrid radiotherapy-MRI devices promise real time tracking of moving tumors to focus the radiation portals to the tumor during irradiation. This approach will benefit from the increased temporal resolution of MRI's data acquisition and reconstruction. In this work, the authors propose a novel spatial-temporal c...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4885960

    authors: Yip E,Yun J,Wachowicz K,Heikal AA,Gabos Z,Rathee S,Fallone BG

    更新日期:2014-08-01 00:00:00

  • Gold nanoparticle enhanced proton therapy: A Monte Carlo simulation of the effects of proton energy, nanoparticle size, coating material, and coating thickness on dose and radiolysis yield.

    abstract:PURPOSE:Radiosensitizer enhanced radiotherapy provides the possibility of improved treatment outcomes by preferentially increasing the effectiveness of radiation within the tumor. Proton therapy offers improved sparing of tissue distal of the tumor along the beam path and reduced integral dose compared to conventional ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13923

    authors: Peukert D,Kempson I,Douglass M,Bezak E

    更新日期:2020-02-01 00:00:00

  • Quantitative single-particle digital autoradiography with α-particle emitters for targeted radionuclide therapy using the iQID camera.

    abstract:PURPOSE:Alpha-emitting radionuclides exhibit a potential advantage for cancer treatments because they release large amounts of ionizing energy over a few cell diameters (50-80 μm), causing localized, irreparable double-strand DNA breaks that lead to cell death. Radioimmunotherapy (RIT) approaches using monoclonal antib...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4921997

    authors: Miller BW,Frost SH,Frayo SL,Kenoyer AL,Santos E,Jones JC,Green DJ,Hamlin DK,Wilbur DS,Fisher DR,Orozco JJ,Press OW,Pagel JM,Sandmaier BM

    更新日期:2015-07-01 00:00:00

  • A simple magnetic spectrometer for radiotherapy electron beams.

    abstract::A small, lightweight, single-focusing magnetic spectrometer was designed, assembled, and tested for analysis of electron beams from radiotherapy electron linacs. The objective was to develop a low cost, simple device that could be easily replicated in other medical centers, and to demonstrate the practicality of indiv...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597271

    authors: Deasy JO,Almond PR,McEllistrem MT,Ross CK

    更新日期:1994-11-01 00:00:00

  • Automatic measurements of image geometry for online calibration of C-arm fluoroscopy.

    abstract::Calibrated C-arm fluoroscopy is used for a variety of surgical procedures where surgical tools and anatomical structures need to be located in space. Calibration can be performed online by combining measurements of the geometry of the image (center and radius) with measurements of a grid of fiducial markers. This arti...

    journal_title:Medical physics

    pub_type: 杂志文章,多中心研究

    doi:10.1118/1.1781331

    authors: Archip N,Rohling R

    更新日期:2004-09-01 00:00:00

  • Classifier performance prediction for computer-aided diagnosis using a limited dataset.

    abstract::In a practical classifier design problem, the true population is generally unknown and the available sample is finite-sized. A common approach is to use a resampling technique to estimate the performance of the classifier that will be trained with the available sample. We conducted a Monte Carlo simulation study to co...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2868757

    authors: Sahiner B,Chan HP,Hadjiiski L

    更新日期:2008-04-01 00:00:00

  • Parametrization of head-scatter factors for rectangular photon fields using an equivalent square formalism.

    abstract::Head-scatter factors of symmetric square and rectangular fields (field center on the central beam axis) defined by the upper (Y) and lower (X) jaws for 6 and 15 MV photon beams from 2300CD and 600C accelerators (Varian Associates, Inc., Palo Alto, CA) were measured, as well as those for fields shaped by the Y jaws and...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597617

    authors: Yu MK,Murray B,Sloboda R

    更新日期:1995-08-01 00:00:00

  • Technical Note: Correction for intra-chamber dose gradients in reference dosimetry of flattening-filter-free MV photon beams.

    abstract:PURPOSE:To estimate and correct for the volume averaging effect which results from the intra-chamber dose gradients when a Farmer ionization chamber (IC) is used for reference dosimetry in flattening-filter-free (FFF) MV photon beams. METHODS:An intra-chamber dose gradients correction factor (kicdg) to the charge read...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4958960

    authors: Ruggieri R,Naccarato S,Stavrev P,Stavreva N,Pasetto S,Salamone I,Alongi F

    更新日期:2016-08-01 00:00:00

  • CeBr3 scintillators for 4 He prompt gamma spectroscopy: Results from a Monte Carlo optimization study.

    abstract:PURPOSE:Range uncertainties limit the potential of charged particle therapy. In vivo and online range verification techniques could increase the confidence in the dose delivery distribution and lead to more conformal treatments. Prompt gamma imaging and prompt gamma spectroscopy (PGS) have been demonstrated for such a ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12795

    authors: Dal Bello R,Magalhaes Martins P,Seco J

    更新日期:2018-04-01 00:00:00

  • Vision 20/20: Positron emission tomography in radiation therapy planning, delivery, and monitoring.

    abstract::Positron emission tomography (PET) is increasingly considered as an effective imaging method to support several stages of radiation therapy. The combined usage of functional and morphological imaging in state-of-the-art PET/CT scanners is rapidly emerging to support the treatment planning process in terms of improved ...

    journal_title:Medical physics

    pub_type: 杂志文章,评审

    doi:10.1118/1.4935869

    authors: Parodi K

    更新日期:2015-12-01 00:00:00

  • Low dose positron emission tomography emulation from decimated high statistics: A clinical validation study.

    abstract:PURPOSE:The fundamental nature of positron emission tomography (PET), as an event detection system, provides some flexibility for data handling, including retrospective data manipulation. The reorganization of acquisition data allows the emulation of new scans arising from identical radiotracer spatial distributions, b...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13517

    authors: Schaefferkoetter J,Nai YH,Reilhac A,Townsend DW,Eriksson L,Conti M

    更新日期:2019-06-01 00:00:00

  • Radiation dose reduction using a CdZnTe-based computed tomography system: comparison to flat-panel detectors.

    abstract:PURPOSE:Although x-ray projection mammography has been very effective in early detection of breast cancer, its utility is reduced in the detection of small lesions that are occult or in dense breasts. One drawback is that the inherent superposition of parenchymal structures makes visualization of small lesions difficul...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3312435

    authors: Le Huy Q,Ducote JL,Molloi S

    更新日期:2010-03-01 00:00:00

  • Quantitative modeling of the accuracy in registering preoperative patient-specific anatomic models into left atrial cardiac ablation procedures.

    abstract:PURPOSE:In cardiac ablation therapy, accurate anatomic guidance is necessary to create effective tissue lesions for elimination of left atrial fibrillation. While fluoroscopy, ultrasound, and electroanatomic maps are important guidance tools, they lack information regarding detailed patient anatomy which can be obtaine...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4861712

    authors: Rettmann ME,Holmes DR 3rd,Kwartowitz DM,Gunawan M,Johnson SB,Camp JJ,Cameron BM,Dalegrave C,Kolasa MW,Packer DL,Robb RA

    更新日期:2014-02-01 00:00:00

  • Voxel clustering for quantifying PET-based treatment response assessment.

    abstract:PURPOSE:Imaging biomarkers are crucial in managing treatment options for cancer patients. They are extremely powerful tools since they allow personalized treatment assessment early during therapy by using repeated imaging to detect and quantify tumor response. Currently, treatment response assessment from consecutive i...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4764900

    authors: Schreibmann E,Waller AF,Crocker I,Curran W,Fox T

    更新日期:2013-01-01 00:00:00

  • Joint model of motion and anatomy for PET image reconstruction.

    abstract::Anatomy-based positron emission tomography (PET) image enhancement techniques have been shown to have the potential for improving PET image quality. However, these techniques assume an accurate alignment between the anatomical and the functional images, which is not always valid when imaging the chest due to respirato...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2804721

    authors: Qiao F,Pan T,Clark JW Jr,Mawlawi O

    更新日期:2007-12-01 00:00:00

  • Real-time distortionless high-factor compression scheme.

    abstract::Nowadays, digital subtraction angiography systems must be able to sustain real-time acquisition (30 frames per second) of 512 x 512 x 8 bit images and store several sequences of such images on low cost and general-purpose mass memories. Concretely, that means a 7.8 Mbytes per second rate and about 780 Mbytes disk spac...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596309

    authors: Liénard J

    更新日期:1989-11-01 00:00:00

  • SU-E-T-622: A Rapid Hybrid VMAT-IMRT Planning Method Using an Abbreviated Beam Angle Optimization Search.

    abstract:PURPOSE:To generate hybrid VMAT-IMRT treatment plans by utilizing an IMRT beam-angle-optimality (BAO) search under a commercially available TPS without the aid of custom optimization software or high performance computing. METHODS:The high dose modulation provided by IMRT beams can be exploited to improve the quality ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735712

    authors: Schulze D,Ionascu D,Tyagi N

    更新日期:2012-06-01 00:00:00

  • Evaluation of the Gafchromic(®) EBT2 film for the dosimetry of radiosurgical beams.

    abstract:PURPOSE:Radiosurgery uses small fields and high-radiation doses to treat intra- and extracranial lesions in a single session. The lack of a lateral electronic equilibrium and the presence of high-dose gradients in these fields are challenges for adequate measurements. The availability of radiation detectors with the hi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4752211

    authors: Larraga-Gutierrez JM,Garcia-Hernandez D,Garcia-Garduno OA,Galvan de la Cruz OO,Ballesteros-Zebadua P,Esparza-Moreno KP

    更新日期:2012-10-01 00:00:00

  • A method for physically based radiotherapy optimization with intelligent tissue weight determination.

    abstract::An important aspect of the intensity modulated radiotherapy (IMRT) process is that of optimizing the beam intensity profiles. Most such methods use a comparison between the defined dose distribution (including prescription dose and dose limits for critical structures) and the current distribution. The comparison may i...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1428756

    authors: Jones L,Hoban P

    更新日期:2002-01-01 00:00:00

  • Tissue-mimicking gelatin-agar gels for use in magnetic resonance imaging phantoms.

    abstract::A new variety of tissue-mimicking materials for use in 1H nuclear magnetic resonance (NMR) phantoms has been developed and extensively tested, principally at 10 MHz and at room temperature. The materials can be formed with a broad range of T1's and T2's representative of soft tissues. They are mixtures of various perc...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596219

    authors: Blechinger JC,Madsen EL,Frank GR

    更新日期:1988-07-01 00:00:00

  • A sparse representation-based radiomics for outcome prediction of higher grade gliomas.

    abstract:PURPOSE:Accurately predicting outcome (i.e., overall survival (OS) time) for higher grade glioma (HGG) has great clinical value and would provide optimized guidelines for treatment planning. Radiomics focuses on revealing underlying pathophysiological information in biomedical images for disease analysis and demonstrat...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13288

    authors: Wu G,Shi Z,Chen Y,Wang Y,Yu J,Lv X,Chen L,Ju X,Chen Z

    更新日期:2019-01-01 00:00:00

  • Solid-tumor radionuclide therapy dosimetry: new paradigms in view of tumor microenvironment and angiogenesis.

    abstract:PURPOSE:The objective of this study is to evaluate requirements for radionuclide-based solid tumor therapy by assessing the radial dose distribution of beta-particle-emitting and alpha-particle-emitting molecules localized either solely within endothelial cells of tumor vasculature or diffusing from the vasculature thr...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3431999

    authors: Zhu X,Palmer MR,Makrigiorgos GM,Kassis AI

    更新日期:2010-06-01 00:00:00

  • Tomotherapy dose distribution verification using MAGIC-f polymer gel dosimetry.

    abstract:PURPOSE:This paper presents the application of MAGIC-f gel in a three-dimensional dose distribution measurement and its ability to accurately measure the dose distribution from a tomotherapy unit. METHODS:A prostate intensity-modulated radiation therapy (IMRT) irradiation was simulated in the gel phantom and the treat...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4704496

    authors: Pavoni JF,Pike TL,Snow J,DeWerd L,Baffa O

    更新日期:2012-05-01 00:00:00

  • Fast technetium-99m liver SPECT for evaluation of the pretreatment procedure for radioembolization dosimetry.

    abstract:PURPOSE:The efficiency of radioembolization procedures could be greatly enhanced if results of the 99m Tc-MAA pretreatment procedure were immediately available in the interventional suite, enabling 1-day procedures as a result of direct estimation of the hepatic radiation dose and lung shunt fraction. This would, howev...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13253

    authors: van der Velden S,Dietze MMA,Viergever MA,de Jong HWAM

    更新日期:2019-01-01 00:00:00

  • A method for determining multileaf collimator transmission and scatter for dynamic intensity modulated radiotherapy.

    abstract::The main purpose of this work is to demonstrate a practical means of determining the leaf transmission and scatter characteristics of a multileaf collimator (MLC) pertinent to the commissioning of dynamic intensity modulated radiotherapy, especially for the sweeping window technique. The data are necessary for the con...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1312190

    authors: Arnfield MR,Siebers JV,Kim JO,Wu Q,Keall PJ,Mohan R

    更新日期:2000-10-01 00:00:00

  • Cavity contour segmentation in chest radiographs using supervised learning and dynamic programming.

    abstract:PURPOSE:Efficacy of tuberculosis (TB) treatment is often monitored using chest radiography. Monitoring size of cavities in pulmonary tuberculosis is important as the size predicts severity of the disease and its persistence under therapy predicts relapse. The authors present a method for automatic cavity segmentation i...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4881096

    authors: Maduskar P,Hogeweg L,de Jong PA,Peters-Bax L,Dawson R,Ayles H,Sánchez CI,van Ginneken B

    更新日期:2014-07-01 00:00:00

  • Nonlinear magnetic stereotaxis: three-dimensional, in vivo remote magnetic manipulation of a small object in canine brain.

    abstract::In a series of in vivo experiments on five adult canines, a small cylindrical permanent magnet (approximately 5-mm diameter x 5 mm long) was magnetically moved under fluoroscopic guidance from an occipital-lobe burr hole to a predetermined destination within the brain and then removed. On three of the animals, dorsal ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596520

    authors: Grady MS,Howard MA 3rd,Molloy JA,Ritter RC,Quate EG,Gillies GT

    更新日期:1990-05-01 00:00:00

  • Choice of material for HVL measurements in megavoltage x-ray beams.

    abstract::The relative sensitivity of the half-value layer (HVL) method as a quality index for megavoltage x-ray beams is examined by theoretical calculation and experimental measurements for 4-, 6-, 10-, and 25-MV x-ray beams. It is shown that lower atomic number materials are more sensitive to beam quality changes than higher...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595794

    authors: Meli JA,Nath R

    更新日期:1985-01-01 00:00:00